OCB Service Information Type OA 3 Operating Mechanism.pdf
PDF 8 MB Posted
- Attached to
- Refurbish 138 KV OCB Breaker
- Solicitation number
- FY265281014
About this file
This document is an Installation, Operating, and Maintenance Instructions manual for the Type OA-3 hydraulic operating mechanism, a hydraulically-closed mechanical device that operates oil circuit breakers at high speeds using compressed nitrogen gas in an accumulator system.
The Type OA-3 mechanism is designed to open and hydraulically reclose breakers in 20 cycles, with energy for five closures stored by compressing nitrogen gas in an accumulator and additional opening energy stored in breaker springs during closure. The mechanism operates through a system of valves, pistons, and mechanical linkage, with manual or electrical operation capabilities. Key technical specifications include: accumulator precharge pressure of 1625±25 psi at 60°F; nitrogen gas purity requirements of 99.9% minimum with maximum oxygen of 0.1%, maximum hydrogen of 0.0%, and maximum moisture of 0.0012%; acceptable hydraulic fluids including Shell Aeroshell Fluid No. 4, Standard Oil RPM Aviation, Texaco Aircraft AA, and Humble Oil Esso Univis J-43; and motor-driven pump operation controlled by pressure switches for system pressurization. The document provides detailed installation requirements including electrical connections, miscellaneous parts handling, hydraulic fluid specifications and filling procedures, precharge pressure verification and adjustment, and final preparation steps. Section VI addresses operation and safety blocking with procedures for normal-speed operation, slow-speed positioning using maintenance-positioning valve 19, blocking in open and closed positions for service, and safety precautions for personnel. Section VII covers reference data and adjustments including accumulator precharge specifications, pressure switches settings, over-pressure relief valve adjustments, and pilot valve rod specifications. Section VIII details routine maintenance including fluid leak checks, general cleanup, lubrication of linkage parts with specified oils, pressure storage system checks, fluid level monitoring, pump operations, mechanism adjustments, pressure switch verification, and auxiliary switch inspection. The spare parts list includes opening and closing coils for 48, 125, and 250 volt DC applications, X and Y relay coils, pressure switch assemblies, and pressure line valve block components, with quantities specified per installation requirement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| OCB Breaker Oil Test Report by STEC.pdf | ||
| OCB Image Binder Pump-Pressure Switch- KerKey plate.pdf | ||
| OCB Image Binder.pdf | ||
| OCB Breaker Control Panel Wiring Components.pdf | ||
| Updated1-PWS- Amistad 138KV Breaker Refurbish rev1.pdf | ||
| OCB Breaker Manufacture Manauls.pdf | ||
| Price Sheet.docx | DOCX document | |
| Wage Determination.txt | TXT text file | |
| Updated - PWS- Amistad 138KV Breaker Refurbish_2.pdf | ||
| Applicable Terms and Conditions.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| Page 2 |
| Page 3 |
| Page 4 |
| Page 5 |
| Page 6 |
| Page 7 |
| Page 8 |
| Page 9 |
| Page 10 |
| Page 11 |
| Page 12 |
| Page 13 |
| Page 14 |
File details come from the government source that posted it. Updated .