Furnace_711_Third.docx
DOCX document 33 KB Posted
- Attached to
- 711 Third St - New Furnace
- Solicitation number
- 2025-COMMUNITY DEVELOPMENT-044
- Issued by
- Kalamazoo County, Huntington Woods City, Michigan
About this file
This is a Work Write-Up document from the City of Jackson Community Development Department in Jackson, Michigan, involving a furnace replacement project for a residential property located at 711 Third St. The document specifies the requirements for replacing an existing furnace with a new 95% efficient, gas-fired forced air furnace that meets Michigan Mechanical Code standards. The project involves installing a new furnace with appropriate output capacity, relocating registers to floor or low wall positions, providing return air mechanisms, installing a new thermostat, and potentially repairing or replacing associated electrical and plumbing infrastructure as needed.
The project is part of a competitive sealed bid process for repairs to program-qualified homeowners, with bidders required to have Sam.gov registration, proper licensing, and necessary permits. While specific pricing details are not explicitly outlined, the document indicates that projects will be awarded to the qualified lowest bidder. The work write-up serves as a detailed specification for contractors, outlining precise installation requirements, including duct insulation, flexible duct usage, and compliance with local heating and ventilation standards for habitable rooms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 711_Third_St_-_New_Furnace.pdf | ||
| All_Services_Sample_Contract_.docx | DOCX document | |
| CDBG_Additional_Forms.pdf | ||
| Labor_and_Material_Payment_Bond.pdf | ||
| Maintenance_and_Guarantee_Bond.pdf | ||
| Performance_Bond.pdf | ||
| Sven's_email_information.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Work Write-Up Furnace
* EXHIBIT 1 *
Dated: 1/24/2025
CUSTOMER INFORMATION
Kitrina Sims 711 Third St, Jackson, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
| General Requirements |
| Quantity |
| Units |
| Total |
1 - F19 - FURNACE - REPLACE
(Specification ID:1.19000 Estimated Qty:0)
* PERMIT REQUIRED *
Replace existing furnace with new 95% efficient forced air, gas fired furnace bearing AGA label. Furnace output capacity shall be sufficient to heat the structure according to NWAHA standards. Installations shall comply with the current Michigan Mechanical Code. All habitable rooms, as designated by the Building Inspector, shall be supplied with warm air sufficient to maintain temperatures according to NWAHA standards. All new register installations shall be located in floor or low wall with the exception of bathrooms, which shall be wall mounted. Provide an adequate means of return air for these new supply runs. The use of ceiling diffuser outlets will be allowed only with prior approval. When new supply or returns are required and duct is run through any habitable room, it shall be enclosed in new or existing walls. Any new enclosure shall match existing surfaces. Installation shall include a register in the warm air plenum or trunkline to provide heat to the cellar and a new thermostat. A filter rack with cover shall be installed in the return air duct outside of the furnace cabinet. Whenever possible, insulate new supply and return ducts in unheated attic spaces, ventilated crawl spaces, and other exposed locations to prevent excessive heat loss. Flexible duct shall be used only in attics or crawl spaces. If not bid As a separate part of this contract, the installation shall include repair or replacement of wiring and/or plumbing necessary to comply with local code. If the existing ductwork is not to be replaced, it must be approved by the Mechanical Inspector and:
Total
Prepared By: sharrison@cityofjackson.org on 1/24/2025
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
| x_________________________ | __________ | |
| Owner: | Date |
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
| x_________________________ | __________ | |
| Contractor | Date |
| x____________________________ | __________ | |
| Construction Specialist | Date |
| Prepared By: sharrison@cityofjackson.org on 1/24/2025 |
| 3 of 3 |