FULL DRAWING BINDER 8-11-2025.pdf

PDF 4 MB Posted

Attached to
Bossier City Municipal Council Chamber Finish Upgrades
Solicitation number
P25-08
Issued by
Bossier Parish, Louisiana

About this file

These architectural drawings detail the Bossier City Municipal Complex Council Chambers Finish Upgrades project located at 620 Benton Road, Bossier City, Louisiana 71111. The project, identified as Bossier City Project #P25-08, is scheduled for completion in August 2025 and involves comprehensive renovations to the existing council chambers. The design documents show a complete interior and exterior upgrade, including demolition of existing finishes, new seating installation, and architectural modifications to the council chambers. The project includes upgrades to both the first and second floors, with specific focus on the council chambers' layout, lighting, wall treatments, and ceiling configurations.

The project documents indicate a total occupancy of 150 people, with new seating and finish improvements throughout the space. The architectural plans, prepared by Kevin Bryan Architect, L.L.C. from Shreveport, Louisiana, show detailed demolition plans, wall sections, elevations, and reflected ceiling plans. The renovation includes removing existing carpet, installing new carpet and base, upgrading wall surfaces, and modifying the interior layout. The city leadership includes Mayor Thomas H. Chandler and a five-member city council, with Andy Bajnauth serving as City Engineer. The plans suggest a phased approach to construction, with careful consideration of existing structures and systems to minimize disruption to municipal operations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A1.0

DRAWING INDEX

ARCHITECTURAL

VICINITY SITE MAP

SYMBOLS LEGEND

A1.0 A3.1

ABBREVIATIONS

BOSSIER CITY MUNICIPAL COMPLEX

COUNCIL CHAMBERS FINISH UPGRADES

At Large - Craton Cochran At Large - Chris Smith District 1 - Brian Hammons District 2 - Debra W. Ross District 3 - Cliff Smith District 4 - Joel Girouard District 5 - Vince Maggio

620 BENTON ROAD, BOSSIER CITY, LOUISIANA 71111

AUGUST 2025

BOSSIER CITY PROJECT # P25-08

Thomas H. Chandler

Andy Bajnauth

A8.1

CITY ADMINISTRATION

CITY COUNCIL

CITY ENGINEER

MAYOR

DEDUCTIVE ALTERNATE

C O

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

GENERAL NOTES

Rodney Taylor

DIRECTOR OF PERMITS AND INSPECTIONS

EAST TEXAS ST.

21 107

21 108 21 109

'-1

(X

, 8

C on c)

9-21

21 108 21 109

21 110 21 111

'-7

(X

, 8

C on c)

11-21

21 109 21 110

21 111 21 112

'-4

(X

, 8

C on c)

12-21

21 110 21 111

21 112 21 113

'-1

(X

, 8

C on c)

13-21

21 111 21 112

21 113 21 114

'-1

0" (X

, 8

C on c)

14-21

21 111 21 112

21 113 21 114

21 115

'-7

(X

, 8

C on c)

15-21

21 112

21 113 21 114

21 115 21 116

'-4

(X

, 8

C on c)

16-21

12'-7" (X, 813 Conc)

7-21

10'-10" (X, 813 Conc)

6-21

9'-0" (X, 813 Conc)

4-21,1-20

7'-3" (X, 813 Conc)

3-21,1-20

'-7

(X , 8

C on c)

7-

'-1

0" (X

, 8

C on

c) 6-

9' -0

(X

, 8

C on

c) 1-

,4

-2

7' -3

(X

, 8

C on

c) 1-

,3

-2

21 108 21 109

21 110

'-1

0" (X

, 8

C on c)

10-21

R4 3'

-6

/1 6"

R2 0'

-9

/1 6"

SP

AC

ES

(8 R

O W

S) A

T 3'

-3

2'

-9

4'-3"

4'- 3"

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

B B

C

C

D

D

E

E

B B

C

C

D

D

E

E

'-1

5/ 8"

FRONT W

ALL

TO SIZE LI

NE

5'-7" (L, 813 Conc)

BENTON RD.

PARTIAL EXISTING BUILDING PLAN

150 TOTAL

OCCUPANTS

150 TOTAL

OCCUPANTS

A3.2 A3.3 A3.4

A8.2

A6.1 A6.2

A6.4

AREA OF NEW WORK - 4,684 S.F.

INCLUDING FINISH UPGRADES AND NEW SEATING

A7.1 A7.2

A6.3

A8.3

PROJECT

LOCATION

CONTRACTOR NOTE: PRICE TO

REMOVE EXISTING CARPET AND BASE

AND REPLACE WITH NEW CARPET AND

RUBBER BASE. THE SAME CARPET WE

ARE USING IN THE COUNCIL CHAMBER.

AutoCAD SHX Text

TITLE SHEET

AutoCAD SHX Text

DEMOLITION FIRST FLOOR PLAN

AutoCAD SHX Text

FIRST REFLECTED CEILING PLANS

AutoCAD SHX Text N

AutoCAD SHX Text JUST PROPERLY SAND AND PREP EXISTING AND NEW COUNCIL SEATING COUNTER TOPS FOR A NEW STAINED AND SEALED FINISH. COLOR SHALL BE CHOSEN BY ARCHITECT. THIS SHALL BE A SUBSTITUTION FOR OUR BASE BID OF STONE.

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text

PAPER HOLDER

AutoCAD SHX Text

VINYL WALL COVERING

AutoCAD SHX Text

TO BE REMOVED

AutoCAD SHX Text

TRANSITION STRIP

AutoCAD SHX Text

VINYL COMPOSITION TILE

AutoCAD SHX Text

STAINLESS STEEL

AutoCAD SHX Text

SCHEDULE

AutoCAD SHX Text

PREPARATION

AutoCAD SHX Text

THRESHOLD

AutoCAD SHX Text

TEMPERED

AutoCAD SHX Text

REQUIRED

AutoCAD SHX Text

REFRIGERATOR

AutoCAD SHX Text

SOAP DISPENSER

AutoCAD SHX Text

SOLID CORE

AutoCAD SHX Text

THICK

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

WITH

AutoCAD SHX Text

PLASTIC

AutoCAD SHX Text

ELECTRIC HAND DRYER

AutoCAD SHX Text

MARBLE THRESHOLD

AutoCAD SHX Text

PAPER TOWEL DISPENSER

AutoCAD SHX Text

FIRE EXTINGUISHER CABINET

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

HANDICAP ELECTRIC DRINKING FOUNTAIN

AutoCAD SHX Text

GYPSUM BOARD

AutoCAD SHX Text

PATTERN

AutoCAD SHX Text

GALVANIZED

AutoCAD SHX Text

MEDICAL

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

LAMINATED

AutoCAD SHX Text

ELEVATION

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

HARDWARE

AutoCAD SHX Text

HOUR

AutoCAD SHX Text

MILLWORK ITEM

AutoCAD SHX Text

LAVATORY

AutoCAD SHX Text

GAUGE

AutoCAD SHX Text

HOLLOW METAL

AutoCAD SHX Text

ON CENTER

AutoCAD SHX Text

MARK

AutoCAD SHX Text

COLUMN

AutoCAD SHX Text

CENTERLINE

AutoCAD SHX Text

CORNER GUARD

AutoCAD SHX Text

ABOVE FINISH FLOOR

AutoCAD SHX Text

CONTINUOUS

AutoCAD SHX Text

CEILING HEIGHT

AutoCAD SHX Text

BOARD

AutoCAD SHX Text

APPROXIMATE

AutoCAD SHX Text L

AutoCAD SHX Text

APPROX.

AutoCAD SHX Text

BD.

AutoCAD SHX Text C.H.

AutoCAD SHX Text

CONT.

AutoCAD SHX Text A.F.F.

AutoCAD SHX Text C.G.

AutoCAD SHX Text C

AutoCAD SHX Text

COL.

AutoCAD SHX Text

MK.

AutoCAD SHX Text O.C.

AutoCAD SHX Text H.M.

AutoCAD SHX Text

GA.

AutoCAD SHX Text

LAV.

AutoCAD SHX Text

MWI.

AutoCAD SHX Text

HR.

AutoCAD SHX Text

HDWR.

AutoCAD SHX Text

MAT'L.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

LAM.

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

MED.

AutoCAD SHX Text

GALV.

AutoCAD SHX Text

PATT.

AutoCAD SHX Text

GYP. BD.

AutoCAD SHX Text H.E.D.F.

AutoCAD SHX Text

EXP. JT.

AutoCAD SHX Text F.E.C.

AutoCAD SHX Text P.T.D.

AutoCAD SHX Text M.T.

AutoCAD SHX Text E.H.D.

AutoCAD SHX Text

PLAS.

AutoCAD SHX Text W/

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

TK.

AutoCAD SHX Text S.C.

AutoCAD SHX Text S.D.

AutoCAD SHX Text

REF.

AutoCAD SHX Text

REQ'D.

AutoCAD SHX Text

TEMP.

AutoCAD SHX Text

THRES.

AutoCAD SHX Text

PREP.

AutoCAD SHX Text

SCHED.

AutoCAD SHX Text S.S.

AutoCAD SHX Text V.C.T.

AutoCAD SHX Text T.S.

AutoCAD SHX Text T.B.R.

AutoCAD SHX Text V.W.C.

AutoCAD SHX Text P.H.

AutoCAD SHX Text

EM. R.D.

AutoCAD SHX Text

EMERGENCY ROOF DRAIN

AutoCAD SHX Text

HOLLOW METAL FRAME MARK

AutoCAD SHX Text

CONSTRUCTION NOTE

AutoCAD SHX Text

DEMOLITION NOTE

AutoCAD SHX Text

INTERIOR ELEVATION MARK

AutoCAD SHX Text

DOOR REFERENCE MARK

AutoCAD SHX Text

DETAIL REFERENCE MARK

AutoCAD SHX Text A-

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

PARTITION TYPE MARK

AutoCAD SHX Text

WINDOW TYPE MARK

AutoCAD SHX Text

INDICATES ITEM OVERHEAD

AutoCAD SHX Text

ITEM TO BE REMOVED

AutoCAD SHX Text

FIRE EXTINGUISHER CABINET IN WALL

AutoCAD SHX Text

BREAK LINE

AutoCAD SHX Text

DIMENSION LINE

AutoCAD SHX Text C1

AutoCAD SHX Text D1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A-

AutoCAD SHX Text

HM-1

AutoCAD SHX Text W1

AutoCAD SHX Text

ALUMINUM FRAME MARK

AutoCAD SHX Text

AF-1

AutoCAD SHX Text

ALUMINUM THRESHOLD

AutoCAD SHX Text A.T.

AutoCAD SHX Text

RE:

AutoCAD SHX Text

REFERENCE

AutoCAD SHX Text

SIM.

AutoCAD SHX Text

SIMILAR

AutoCAD SHX Text

ELECTRIC DRINKING FOUNTAIN

AutoCAD SHX Text E.D.F.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text 3.

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text 6.

AutoCAD SHX Text 7.

AutoCAD SHX Text 8.

AutoCAD SHX Text 9.

AutoCAD SHX Text 10.

AutoCAD SHX Text 11.

AutoCAD SHX Text 12.

AutoCAD SHX Text 13.

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL DEMOLITION AND CONSTRUCTION DEBRIS. ALL TRASH AND DEBRIS SHOULD BE DISPOSED OF PROPERLY AND APPROPRIATELY. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED W/ DISPOSAL.

AutoCAD SHX Text ALL ELECTRICAL WORK IS TO BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR OR THOSE DIRECTLY UNDER HIS SUPERVISION. ALL WORK PERFORMED IS TO BE PER ALL CITY, STATE, AND NATIONAL CURRENT ELECTRICAL CODES.

AutoCAD SHX Text CONTRACTOR TO VERIFY THE SALVAGE OF ANY MATERIAL THAT COULD POSSIBLY BE REUSED UNDER THIS CONTRACT.

AutoCAD SHX Text CONTRACTOR TO KEEP THE FACILITY REASONABLY CLEAN DURING CONSTRUCTION HOURS AND TO COMPLETELY CLEAN UP SITE AT THE END OF EACH DAY. OTHER BUSINESSES DIRECTLY CONNECTED TO THIS FACILITY ARE NOT TO BE ADVERSELY AFFECTED BY CONSTRUCTION.

AutoCAD SHX Text

CONTRACTOR TO BE FULLY LICENSED, FOR THIS JOB, AND INSURED.

AutoCAD SHX Text ANY DAMAGE TO THE EXISTING OR NEW FACILITY CAUSED BY THE CONTRACTOR OR ANY ONE UNDER HIS CONTRACT, IS TO BE FULLY REPAIRED OR REPLACED. DAMAGE TO EXISTING SITE TO BE REPAIRED. RUTS IN YARD TO BE FILLED IN AND RE-SODDED IF DAMAGED.

AutoCAD SHX Text CONTRACTOR TO NOTIFY OWNER AND/OR ARCHITECT IMMEDIATELY IF DISCREPANCIES BETWEEN DRAWINGS AND EXISTING CONSTRUCTION EXISTS.

AutoCAD SHX Text CONTRACTOR AND ALL THOSE UNDER HIS CONTRACT ARE TO PERFORM ALL WORK IN A WELL-MANNERED FASHION. TENANTS AT ADJACENT BUSINESSES ARE NOT TO BE BOTHERED OR HARASSED IN ANY FORM OR FASHION. SUCH SHALL BE CAUSE FOR IMMEDIATE AND PERMANENT REMOVAL FROM SITE.

AutoCAD SHX Text CONTRACTOR TO PROVIDE TEMPORARY TOILET FACILITIES. TOILETS AT ADJACENT BUSINESSES ARE NOT TO BE USED BY ANYONE UNDER CONTRACTOR'S CONTRACT.

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR HIS OWN COMMUNICATIONS ON SITE. EXIST. TENANTS ARE NOT TO BE ASKED FOR USE OF PHONE, FAX, COPIER, ETC.

AutoCAD SHX Text CONTRACTOR TO BE RESPONSIBLE FOR ACQUIRING ALL CITY PERMITS REQUIRED FOR CONSTRUCTION INCLUDING CITY DESIGN REVIEW FEE IF APPLICABLE.

AutoCAD SHX Text CONTRACTOR RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGHOUT CONSTRUCTION DURATION, AS WELL AS FINAL INSPECTION BY FIRE MARSHAL. CONTRACTOR TO NOTIFY ARCHITECT AT LEAST ONE WEEK IN ADVANCE OF FINAL INSPECTION.

AutoCAD SHX Text ALL PLUMBING WORK IS TO BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR OR THOSE DIRECTLY UNDER HIS SUPERVISION. ALL WORK PERFORMED IS TO BE PER ALL CITY, STATE, AND NATIONAL CURRENT PLUMBING CODES.

AutoCAD SHX Text

%%UEXISTING

AutoCAD SHX Text

%%USTAIR

AutoCAD SHX Text

%%UELEV.

AutoCAD SHX Text

%%UEQ.

AutoCAD SHX Text

%%UMECH. CHASE

AutoCAD SHX Text

%%UEXISTING

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text E

AutoCAD SHX Text

CB

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text H

AutoCAD SHX Text F

AutoCAD SHX Text

EB

AutoCAD SHX Text

CA

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

IX

AutoCAD SHX Text

VIII

AutoCAD SHX Text

VII

AutoCAD SHX Text

VI

AutoCAD SHX Text V

AutoCAD SHX Text

IV

AutoCAD SHX Text

III

AutoCAD SHX Text

SCALE: 3/32" = 1'-0"

AutoCAD SHX Text

CITY COUNCIL

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

COUNCIL CHAMBER LOBBY

AutoCAD SHX Text

COUNCIL CONF.

AutoCAD SHX Text

CLERK

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text

COUNCIL OFFICE

AutoCAD SHX Text

CORR.

AutoCAD SHX Text W.

AutoCAD SHX Text M.

AutoCAD SHX Text

HALL

AutoCAD SHX Text

75 OCC.

AutoCAD SHX Text

75 OCC.

AutoCAD SHX Text

EXIT

AutoCAD SHX Text

75 OCC.

AutoCAD SHX Text

75 OCC.

AutoCAD SHX Text

219 OCC.

AutoCAD SHX Text

ACCOMMODATES

AutoCAD SHX Text

219 OCC.

AutoCAD SHX Text

FIRST FLOOR PLAN

AutoCAD SHX Text

DEMOLITION SECOND FLOOR PLAN

AutoCAD SHX Text

FIRST FLOOR LOBBY/SECOND FLOOR PLAN AND SCHEDULES

AutoCAD SHX Text

DEMOLITION SECOND FLOOR REFLECTED CEILING PLAN

AutoCAD SHX Text

INTERIOR ELEVATIONS DEMO AND NEW

AutoCAD SHX Text

INTERIOR ELEVATIONS DEMO AND NEW

AutoCAD SHX Text

CASEWORK SECTIONS AND DETAILS

AutoCAD SHX Text

WALL SECTIONS AND DETAILS

AutoCAD SHX Text

WALL SECTIONS AND DETAILS

AutoCAD SHX Text

INTERIOR ELEVATIONS DEMO AND NEW

AutoCAD SHX Text

SECOND FLOOR REFLECTED CEILING PLAN

AutoCAD SHX Text I.T.

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

EXIST. ELEC. PANEL C1A INDICATES ROOM FOR MORE POWER

C O

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

A3.1

GENERAL NOTES

DEMOLITION FIRST FLOOR PLAN WALL TYPE LEGEND

FOR PHASING

DEMOLITION NOTES

SECURITY CAMERAS

AND SALVAGE

REMOVE ALL

FOR OWNER.

NOTE:

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text G

AutoCAD SHX Text

EB

AutoCAD SHX Text

CA

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

VIII

AutoCAD SHX Text

VII

AutoCAD SHX Text

VI

AutoCAD SHX Text T

AutoCAD SHX Text D1

AutoCAD SHX Text D2

AutoCAD SHX Text

EXISTING FIXED SEATING TO BE REMOVED.

AutoCAD SHX Text D3

AutoCAD SHX Text D4

AutoCAD SHX Text

REMOVE ALL EXISTING CARPET INSIDE THIS AREA.

AutoCAD SHX Text REMOVE ALL EXISTING ACOUSTICAL PANELS AND ANY RELATED SUB STRUCTURE COMPLETELY. ALSO REMOVE GYPSUM WALL BOARD BENEATH THE PANELS.

AutoCAD SHX Text D5

AutoCAD SHX Text

REMOVE ALL EXISTING DRAPES AND OR WINDOW SHADES.

AutoCAD SHX Text REMOVE EXISTING EXIT SIGNAGE BUT POWER SHALL REMAIN. CAP OFF LOOSE POWER UNTIL NEW LIGHTING IS INSTALLED. USE THIS POWER FOR THE NEW WALL SCONCES.

AutoCAD SHX Text A. REMOVE ALL EXISTING SIGNAGE WITHIN PROJECT AREA. REMOVE ALL EXISTING SIGNAGE WITHIN PROJECT AREA. REMOVE ANY AND ALL EXISTING LIGHTING WITHIN PROJECT AREA AND PROPERLY CAP OFF EXIST. ELECTRICAL. B. REMOVE ALL EXISTING WOOD BASE/RUBBER BASE WITHIN REMOVE ALL EXISTING WOOD BASE/RUBBER BASE WITHIN PROJECT LIMITS. C. REMOVE ALL EXISTING CARPET. REMOVE ALL EXISTING CARPET. D. REPLACE ALL EXISTING FURNITURE. -O.F.O.I. REPLACE ALL EXISTING FURNITURE. -O.F.O.I. E. REMOVE ALL EXISTING BLINDS AND OR DRAPES. REMOVE ALL EXISTING BLINDS AND OR DRAPES. F. REMOVE ALL EXISTING CEILING. GRID AND WIRE TIES REMOVE ALL EXISTING CEILING. GRID AND WIRE TIES SHALL REMAIN.

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

COUNCIL CHAMBER FOYER

AutoCAD SHX Text

I.T. ROOM

AutoCAD SHX Text

CITY COUNCIL

AutoCAD SHX Text

COUNCIL OFFICE

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text

CLERK

AutoCAD SHX Text M.

AutoCAD SHX Text W.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

HALL

AutoCAD SHX Text

COUNCIL CONF.

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text D6

AutoCAD SHX Text REMOVE EXISTING CASEWORK AT THIS LOCATION. ALL POWER, DATA, AND ALL ITEMS REQUIRED TO CONTINUE JOB AT THIS LOCATION SHALL REMAIN AND BE PROTECTED DURING CONSTRUCTION.

AutoCAD SHX Text

EXIST. WALL TO REMAIN

AutoCAD SHX Text

ITEMS REMOVED

AutoCAD SHX Text N

AutoCAD SHX Text

EXISTING BALCONY ABOVE

AutoCAD SHX Text D1

AutoCAD SHX Text D1

AutoCAD SHX Text D1

AutoCAD SHX Text

EXISTING PODIUM

AutoCAD SHX Text

EXISTING COUNCIL SEATING

AutoCAD SHX Text D2

AutoCAD SHX Text D2

AutoCAD SHX Text D7

AutoCAD SHX Text REMOVE EXISTING LIGHTING. CAP OFF LOOSE POWER FOR NEW LIGHTING TO BE INSTALLED BACK.

AutoCAD SHX Text D7

AutoCAD SHX Text D7

AutoCAD SHX Text D8

AutoCAD SHX Text REMOVE EXISTING TIME OF DAY CLOCK. TIE EXISTING POWER OFF AND PREPARE TO ADD A NEW TIME OF DAY CLOCK.

AutoCAD SHX Text D4

AutoCAD SHX Text D4

AutoCAD SHX Text D8

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D9

AutoCAD SHX Text

COMPLETELY REMOVE DECORATIVE WALL AND CROWN MOLDING ELEMENT.

AutoCAD SHX Text D9

AutoCAD SHX Text D7

AutoCAD SHX Text D7

AutoCAD SHX Text D6

AutoCAD SHX Text D6

AutoCAD SHX Text D10

AutoCAD SHX Text

REMOVE EXISTING DOOR.

AutoCAD SHX Text D10

AutoCAD SHX Text CONTRACTOR SHALL HAVE A COORDINATION MEETING PRIOR TO BEGINNING CONSTRUCTION FOR PHASING OF PROJECT. ALL FLOORING AND SEATING SHALL BE REMOVED AND REPLACED. CONTRACTOR MAY NEED TO HAVE ACCESS TO TEMPORARY FOLDABLE SEATING FOR SPECIAL EVENTS WHICH STILL PLAN TO MEET HERE ONCE A MONTH. CONTRACTOR CAN CREATE A SMALLER MEETING AREA WITHIN THIS SPACE FOR THOSE TIMES. NOTE: OWNER SHALL REMOVE ALL FURNITURE PRIOR TO CONSTRUCTION.

AutoCAD SHX Text D11

AutoCAD SHX Text EXISTING LIGHTING CONTROLS AND OR THERMOSTAT. REMOVE AND THEN COORDINATE W/ELECTRICIAN FOR GETTING NEW SIMILAR TYPE CONTROLS.

AutoCAD SHX Text D11

AutoCAD SHX Text D11

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text

REFER TO DRAWING SHEET A3.3 FOR MORE DETAILED INFORMATION ON THIS FOYER AREA.

AutoCAD SHX Text

AutoCAD SHX Text A6.4

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text

SIM./

AutoCAD SHX Text

OPP.

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text D5

AutoCAD SHX Text D5

AutoCAD SHX Text D12

AutoCAD SHX Text REMOVE EXISTING MOLDING, GLASS, AND EXISTING WALL DIRECTLY BENEATH THE GLASS. PREPARE TO FILL IN THIS HOLE WITH LIKE CONSTRUCTION.

AutoCAD SHX Text D12

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

FIND EXISTING POWER PANEL IN THIS ROOM

AutoCAD SHX Text D13

AutoCAD SHX Text

REMOVE EXISTING THRESHOLD.

AutoCAD SHX Text D14

AutoCAD SHX Text

REMOVE PORTION OF EXISTING WALL FOR ADDED POWER AND DATA.

AutoCAD SHX Text D14

AutoCAD SHX Text NOTE: PREP WORK NEEDS TO BE DONE HERE FOR (2)"CLOCK BOX" TYPE OUTLETS AND (1) "DATA CONDUIT IN 34"DATA CONDUIT IN MIDDLE. VERIFY W/OWNER SIZE OF T.V. AND PROPER LOCATIONS AND HEIGHT. ONCE LOCATIONS ARE VERIFIED WE WANT EXISTING CMU BLOCK CUT OUT FOR NEW INSTALLATION UP TO CEILING SPACE ABOVE FURR DOWN AND BACK TO EXISTING ELECTRICAL PANEL. NEW GYPSUM BOARD WILL EVENTUALLY COVER THIS.

AutoCAD SHX Text

SECURITY CAMERAS

AutoCAD SHX Text D15

AutoCAD SHX Text SAWCUT AND REMOVE PORTION OF EXISTING CONCRETE FLOOR AS INDICATED - CONTINUOUS 1'-0"WIDE TRENCH.

AutoCAD SHX Text D15

AutoCAD SHX Text D15

D15

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

A3.2

16'-1" (X, 813 Conc) 9-21

19'-7" (X, 813 Conc) 11-21

21'-4" (X, 813 Conc) 12-21

23'-1" (X, 813 Conc) 13-21

24'-10"

(X, 813 Conc) 14-21

26'-7" (X, 813 Conc) 15-21

28'-4" (X, 813 Conc) 16-21

12'-7"(X, 813 Conc)

7-21

10'-10"(X, 813 Conc)

6-21

9'-0"(X, 813 Conc)

4-21,1-20

7'-3"(X, 813 Conc)

3-21,1-20

21 4

21 2

'-7

(X

, 8

C on c)

7-21

21 2

'-1

0" (X

, 8

C on c)

6-21

9'- 0"

(X , 8

C on c)

1-20,4-21

7'- 3"

(X , 8

C on c)

1-20,3-21

17'-10"

(X, 813 Conc) 10-21

R4 3'

-6

/1 6"

R2 0'-

9/

SP

AC

ES

(8 R

O W

S) A

T 3'

-3

2'

-9

4'-3"4'-3"

AA

BB

CC

DD

EE

FF

GG

HH

B

B

C

C

D

D

E

E

B

B

C

C

D

D

E

E

'-1

/8

FR

O N

T W

AL

L

TO

S

IZ

E

LI

N

E

5'-7"(L, 813 Conc)

CONSTRUCTION NOTES

FIRST FLOOR PLAN

WALL TYPE LEGEND

GENERAL NOTES

FOR PHASING

NOTE:

CONTRACTOR REFER TO

COVER SHEET FOR SOME

ADDITIONAL FINISH

REPLACEMENT IN BACK OF

HOUSE OFFICES.

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text

EB

AutoCAD SHX Text

CA

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text

VII

AutoCAD SHX Text

VI

AutoCAD SHX Text C1

AutoCAD SHX Text C2

AutoCAD SHX Text

NEW AUDITORIUM STYLE SEATING BY IRWIN SEATING.

AutoCAD SHX Text C3

AutoCAD SHX Text C4

AutoCAD SHX Text

NEW REPLACEMENT LIGHTS (SAME SIZE)

AutoCAD SHX Text NEW O.F.O.I. WALL MOUNTED T.V.-ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING (2)CLOCK BOX TYPE OUTLETS AT EACH NEW T.V. LOCATION ALONG WITH (1) "DATA 34"DATA LINE. VERIFY PROPER MOUNTING LOCATIONS WITH OWNER PRIOR TO INSTALLATION.

AutoCAD SHX Text C5

AutoCAD SHX Text C6

AutoCAD SHX Text

NEW " THICK STONE COUNTER TOP.34" THICK STONE COUNTER TOP.

AutoCAD SHX Text C7

AutoCAD SHX Text C8

AutoCAD SHX Text C9

AutoCAD SHX Text PRIOR TO INSTALLING NEW ACOUSTICAL WALLS AND WALL PANELING CONTRACTOR SHALL REPAIR AS REQUIRED ALL EXISTING GYPSUM BOARD FINISHED WALLS. PRICE TO REPLACE ALL EXISTING GYPSUM BOARD WHICH IS CURRENTLY BENEATH THE EXISTING ACOUSTICAL WALL PANELS. THESE WALLS SHALL BE PAINTED IN WHAT WILL APPEAR TO BE JOINTS BETWEEN ACOUSTICAL WALL PANELS.

AutoCAD SHX Text PROVIDE NEW CASEWORK HERE. VFY. W/ OWNER FOR NEW DATA AND POWER WHICH WAS REMOVED FROM ORIGINAL CASEWORK IN THIS AREA.

AutoCAD SHX Text

EXISTING ALUMINUM DOOR TO REMAIN. PROTECT DURING CONSTRUCTION.

AutoCAD SHX Text

ALL NON FIXED SEATING SHALL BE NEW. -O.F.O.I.

AutoCAD SHX Text FURR OUT THE EXISTING WALL TO ALIGN FLUSH WITH THE EXISTING COLUMN FACE. THIS HAPPENS ON EACH SIDE OF THE ROOM.

AutoCAD SHX Text C10

AutoCAD SHX Text

PROVIDE A REALLY DARK WINDOW FILM. NO BLINDS REQUIRED.

AutoCAD SHX Text C11

AutoCAD SHX Text FILL IN EXISTING OPENING WITH LIKE CONSTRUCTION - COVER EACH SIDE OF WALL WITH PAINTED GYPSUM BOARD SO THAT EXIST. WALL APPEARS AS THOUGH IT NEVER HAD AN OPENING.

AutoCAD SHX Text C12

AutoCAD SHX Text WHERE A TRENCH WAS CUT INTO THE EXISTING CONCRETE FLOOR. PROVIDE (3)2"DIA. CONDUITS FROM THE PODIUM LOCATION OVER TO THE COUNCIL SEATING LOCATION. PROVIDE (5)2"DIA. CONDUITS FROM THE COUNCIL SEATING LOCATION TO THE I.T. ROOM. ONCE INSTALLED FILL THE HOLE BACK IN WITH CONCRETE WHERE CONCRETE FLOOR WAS REMOVED. CONTRACTOR DBL. CHECK AND COORDINATE W/ ARCHITECT AND OWNER PRIOR TO INSTALLING CONDUIT.

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

COUNCIL CHAMBER FOYER

AutoCAD SHX Text

I.T. ROOM

AutoCAD SHX Text

COUNCIL OFFICE

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text

CLERK

AutoCAD SHX Text M.

AutoCAD SHX Text W.

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

HALL

AutoCAD SHX Text

COUNCIL CONF.

AutoCAD SHX Text N

AutoCAD SHX Text

EXIST. WALL TO REMAIN

AutoCAD SHX Text

NEW MTL. STUD WALL

AutoCAD SHX Text

ITEMS REMOVED

AutoCAD SHX Text

CITY COUNCIL

AutoCAD SHX Text

EXISTING BALCONY ABOVE

AutoCAD SHX Text

EXISTING PODIUM

AutoCAD SHX Text

EXISTING COUNCIL SEATING

AutoCAD SHX Text

AutoCAD SHX Text C11

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text C13

AutoCAD SHX Text PROVIDE A NEW ROUND SHAPED CITY OF BOSSIER CITY SEAL (6'-0"DIA.). PROVIDE BLOCKING IN WALL AS REQUIRED.

AutoCAD SHX Text C13

AutoCAD SHX Text C10

AutoCAD SHX Text C10

AutoCAD SHX Text C14

AutoCAD SHX Text

PAINT EXISTING LOW WALL AND MOLDING TO MATCH ALL OTHER PAINTED WOOD SURFACES.

AutoCAD SHX Text C14

AutoCAD SHX Text C14

AutoCAD SHX Text

INSTALL STONE ON TOP OF EXISTING CASEWORK FOR MAIN COUNCIL SEATING AREA

AutoCAD SHX Text

INSTALL STONE ON TOP OF NEW CASEWORK FOR NEW 2 SEAT AREA

AutoCAD SHX Text

INSTALL STONE ON TOP OF NEW CASEWORK FOR NEW 2 SEAT AREA

AutoCAD SHX Text C15

AutoCAD SHX Text C8

AutoCAD SHX Text C8

AutoCAD SHX Text C8

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C15

AutoCAD SHX Text C2

AutoCAD SHX Text C2

AutoCAD SHX Text C15

AutoCAD SHX Text A. REMOVE AND OR DO A ONE TO ONE REPLACEMENT FOR REMOVE AND OR DO A ONE TO ONE REPLACEMENT FOR EXISTING LIGHTING. B. PROVIDE NEW 6" STAINED OR PAINTED WOOD BASE. PROVIDE NEW 6" STAINED OR PAINTED WOOD BASE. C. PROVIDE NEW CARPET TILE. PROVIDE NEW CARPET TILE. D. REPLACE ALL NON FIXED FURNITURE. -O.F.O.I. REPLACE ALL NON FIXED FURNITURE. -O.F.O.I. E. PROVIDE NEW CEILING TILES INTO EXISTING GRID. PROVIDE NEW CEILING TILES INTO EXISTING GRID. F. OWNER SHALL PROVIDE NEW SECURITY CAMERAS AS OWNER SHALL PROVIDE NEW SECURITY CAMERAS AS REQUIRED. G. OWNER SHALL REMOVE AND RE-PULL EXISTING DATA AS OWNER SHALL REMOVE AND RE-PULL EXISTING DATA AS REQUIRED.

AutoCAD SHX Text C3

AutoCAD SHX Text C3

AutoCAD SHX Text C4

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text C9

AutoCAD SHX Text C9

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text C1

AutoCAD SHX Text C1

AutoCAD SHX Text C8

AutoCAD SHX Text C4

AutoCAD SHX Text

STEP

AutoCAD SHX Text

STEP

AutoCAD SHX Text CONTRACTOR SHALL HAVE A COORDINATION MEETING PRIOR TO BEGINNING CONSTRUCTION FOR PHASING OF PROJECT. ALL FLOORING AND SEATING SHALL BE REMOVED AND REPLACED. CONTRACTOR MAY NEED TO HAVE ACCESS TO TEMPORARY FOLDABLE SEATING FOR SPECIAL EVENTS WHICH STILL PLAN TO MEET HERE ONCE A MONTH. CONTRACTOR CAN CREATE A SMALLER MEETING AREA WITHIN THIS SPACE FOR THOSE TIMES.

AutoCAD SHX Text

AutoCAD SHX Text A6.4

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A6.4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text

SIM

AutoCAD SHX Text A6.4

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text

EA. SIDE SIM.

AutoCAD SHX Text PROVIDE NEW ACOUSTIC SLAT WOOD WALL PANELS HERE. SHALL BE EQUAL TO SLATPANEL LUXE FIRE-RATED ACOUSTIC WOOD WALL PANEL (WALNUT)BY THE WOOD VENEER HUB sales@thewoodveneerhub.com thewoodveneerhub.com 302-216-6177

AutoCAD SHX Text C12

AutoCAD SHX Text C12

C12

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

A3.3

DEMOLITION SECOND FLOOR PLAN

DEMOLITION FIRST FLOOR LOBBY PLAN

FOR PHASING

GENERAL NOTES

WALL TYPE LEGEND

DEMOLITION NOTES

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

LAW LIBRARY

AutoCAD SHX Text

CITY COUNCIL

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

BALCONY

AutoCAD SHX Text

OFFICE-4

AutoCAD SHX Text

COFFEE

AutoCAD SHX Text

CL.

AutoCAD SHX Text N

AutoCAD SHX Text

OFFICE-6

AutoCAD SHX Text

OFFICE-8

AutoCAD SHX Text D10

AutoCAD SHX Text D10

AutoCAD SHX Text

EXISTING BALCONY RAILING

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text CONTRACTOR SHALL SAND, AND PREPARE TO RESTAIN OR PAINT EXISTING WOOD RAILING TO MATCH ALL OTHER STAINED OR PAINTED WOOD ON THIS PROJECT

AutoCAD SHX Text D2

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

COUNCIL CHAMBER FOYER

AutoCAD SHX Text

CLERK

AutoCAD SHX Text

COUNCIL CONF.

AutoCAD SHX Text

TO EXISTING BRIDGE

AutoCAD SHX Text D2

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text D4

AutoCAD SHX Text D4

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text D13

AutoCAD SHX Text D13

AutoCAD SHX Text

FOR THIS AREA -REMOVE CARPET -REMOVE BASE -REMOVE CEILING AND GRID

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text CONTRACTOR SHALL HAVE A COORDINATION MEETING PRIOR TO BEGINNING CONSTRUCTION FOR PHASING OF PROJECT. ALL FLOORING AND SEATING SHALL BE REMOVED AND REPLACED. CONTRACTOR MAY NEED TO HAVE ACCESS TO TEMPORARY FOLDABLE SEATING FOR SPECIAL EVENTS WHICH STILL PLAN TO MEET HERE ONCE A MONTH. CONTRACTOR CAN CREATE A SMALLER MEETING AREA WITHIN THIS SPACE FOR THOSE TIMES.

AutoCAD SHX Text D1

AutoCAD SHX Text D2

AutoCAD SHX Text

EXISTING FIXED SEATING TO BE REMOVED.

AutoCAD SHX Text D3

AutoCAD SHX Text D4

AutoCAD SHX Text

REMOVE ALL EXISTING CARPET INSIDE THIS AREA.

AutoCAD SHX Text REMOVE ALL EXISTING ACOUSTICAL PANELS AND ANY RELATED SUB STRUCTURE COMPLETELY. ALSO REMOVE GYPSUM WALL BOARD BENEATH THE PANELS.

AutoCAD SHX Text D5

AutoCAD SHX Text

REMOVE ALL EXISTING DRAPES AND OR WINDOW SHADES.

AutoCAD SHX Text REMOVE EXISTING EXIT SIGNAGE BUT POWER SHALL REMAIN. CAP OFF LOOSE POWER UNTIL NEW LIGHTING IS INSTALLED. USE THIS POWER FOR THE NEW WALL SCONCES.

AutoCAD SHX Text A. REMOVE ALL EXISTING SIGNAGE WITHIN PROJECT AREA. REMOVE ALL EXISTING SIGNAGE WITHIN PROJECT AREA. REMOVE ANY AND ALL EXISTING LIGHTING WITHIN PROJECT AREA AND PROPERLY CAP OFF EXIST. ELECTRICAL. B. REMOVE ALL EXISTING WOOD BASE/RUBBER BASE WITHIN REMOVE ALL EXISTING WOOD BASE/RUBBER BASE WITHIN PROJECT LIMITS. C. REMOVE ALL EXISTING CARPET. REMOVE ALL EXISTING CARPET. D. REPLACE ALL EXISTING FURNITURE. -O.F.O.I. REPLACE ALL EXISTING FURNITURE. -O.F.O.I. E. REMOVE ALL EXISTING BLINDS AND OR DRAPES. REMOVE ALL EXISTING BLINDS AND OR DRAPES. F. REMOVE ALL EXISTING CEILING. GRID AND WIRE TIES REMOVE ALL EXISTING CEILING. GRID AND WIRE TIES SHALL REMAIN.

AutoCAD SHX Text D6

AutoCAD SHX Text REMOVE EXISTING CASEWORK AT THIS LOCATION. ALL POWER, DATA, AND ALL ITEMS REQUIRED TO CONTINUE JOB AT THIS LOCATION SHALL REMAIN AND BE PROTECTED DURING CONSTRUCTION.

AutoCAD SHX Text

EXIST. WALL TO REMAIN

AutoCAD SHX Text

NEW MTL. STUD WALL

AutoCAD SHX Text

ITEMS REMOVED

AutoCAD SHX Text D7

AutoCAD SHX Text REMOVE EXISTING LIGHTING. CAP OFF LOOSE POWER FOR NEW LIGHTING TO BE INSTALLED BACK.

AutoCAD SHX Text D8

AutoCAD SHX Text REMOVE EXISTING TIME OF DAY CLOCK. TIE EXISTING POWER OFF AND PREPARE TO ADD A NEW TIME OF DAY CLOCK.

AutoCAD SHX Text D9

AutoCAD SHX Text

COMPLETELY REMOVE DECORATIVE WALL AND CROWN MOLDING ELEMENT.

AutoCAD SHX Text D10

AutoCAD SHX Text

REMOVE EXISTING DOOR.

AutoCAD SHX Text D11

AutoCAD SHX Text EXISTING LIGHTING CONTROLS AND OR THERMOSTAT. REMOVE AND THEN COORDINATE W/ELECTRICIAN FOR GETTING NEW SIMILAR TYPE CONTROLS.

AutoCAD SHX Text D12

AutoCAD SHX Text REMOVE EXISTING MOLDING AND GLASS. PREPARE TO FILL IN THIS HOLE WITH LIKE CONSTRUCTION.

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text

SIM./

AutoCAD SHX Text

OPP.

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text D13

REMOVE EXISTING THRESHOLD.

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

A3.4

SECOND FLOOR PLAN

FIRST FLOOR LOBBY PLAN

WALL TYPE LEGEND

CONSTRUCTION NOTES

GENERAL NOTES

FOR PHASING

ROOM FINISH SCHEDULE

DOOR REFERENCE SCHEDULE

NOTE:

CONTRACTOR REFER TO

COVER SHEET FOR SOME

ADDITIONAL FINISH

REPLACEMENT IN BACK OF

HOUSE OFFICES.

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

LAW LIBRARY

AutoCAD SHX Text

CITY COUNCIL

AutoCAD SHX Text

CONFERENCE

AutoCAD SHX Text

CORR.

AutoCAD SHX Text

BALCONY

AutoCAD SHX Text

OFFICE-4

AutoCAD SHX Text

COFFEE

AutoCAD SHX Text

CL.

AutoCAD SHX Text N

AutoCAD SHX Text

OFFICE-6

AutoCAD SHX Text

OFFICE-8

AutoCAD SHX Text

EXISTING BALCONY RAILING

AutoCAD SHX Text C16

AutoCAD SHX Text CONTRACTOR SHALL SAND, AND PREPARE TO RESTAIN EXISTING WOOD RAILING TO MATCH ALL OTHER STAINED WOOD ON THIS PROJECT

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text N

AutoCAD SHX Text

COUNCIL CHAMBER FOYER

AutoCAD SHX Text

CLERK

AutoCAD SHX Text

COUNCIL CONF.

AutoCAD SHX Text

TO EXISTING BRIDGE

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN - PROTECT DURING CONSTRUCTION

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text

EXIST. WALL TO REMAIN

AutoCAD SHX Text

NEW MTL. STUD WALL

AutoCAD SHX Text

ITEMS REMOVED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text FOR THIS AREA -PROVIDE NEW CARPET TILE -PROVIDE NEW 6"WOOD BASE PAINTED -PROVIDE NEW CEILING (2'X2') AND GRID

AutoCAD SHX Text C16

AutoCAD SHX Text STOP ACOUSTICAL WALL PANELS HERE. EVERYTHING FROM HERE AND INTO AND ABOVE THE LAW LIBRARY SHALL BE PAINTED.

AutoCAD SHX Text STOP ACOUSTICAL WALL PANELS HERE. EVERYTHING FROM HERE AND INTO AND ABOVE THE LAW LIBRARY SHALL BE PAINTED.

AutoCAD SHX Text

PAINT ALL GYPSUM BOARD WALLS FROM THIS POINT INTO AND ABOVE THE LAW LIBRARY

AutoCAD SHX Text

PAINT ALL GYPSUM BOARD WALLS FROM THIS POINT INTO AND ABOVE THE LAW LIBRARY

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text A6.2

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text C1

AutoCAD SHX Text C2

AutoCAD SHX Text

NEW AUDITORIUM STYLE SEATING BY IRWIN SEATING.

AutoCAD SHX Text C3

AutoCAD SHX Text C4

AutoCAD SHX Text

NEW REPLACEMENT LIGHTS (SAME SIZE)

AutoCAD SHX Text NEW O.F.O.I. WALL MOUNTED T.V.-ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING (2)CLOCK BOX TYPE OUTLETS AT EACH NEW T.V. LOCATION ALONG WITH (1) "DATA 34"DATA LINE. VERIFY PROPER MOUNTING LOCATIONS WITH OWNER PRIOR TO INSTALLATION.

AutoCAD SHX Text C5

AutoCAD SHX Text C6

AutoCAD SHX Text

NEW " THICK STONE COUNTER TOP.34" THICK STONE COUNTER TOP.

AutoCAD SHX Text C7

AutoCAD SHX Text C8

AutoCAD SHX Text C9

AutoCAD SHX Text PRIOR TO INSTALLING NEW ACOUSTICAL WALLS AND WALL PANELING CONTRACTOR SHALL REPAIR AS REQUIRED ALL EXISTING GYPSUM BOARD FINISHED WALLS. PRICE TO REPLACE ALL EXISTING GYPSUM BOARD WHICH IS CURRENTLY BENEATH THE EXISTING ACOUSTICAL WALL PANELS. THESE WALLS SHALL BE PAINTED IN WHAT WILL APPEAR TO BE JOINTS BETWEEN ACOUSTICAL WALL PANELS.

AutoCAD SHX Text PROVIDE NEW CASEWORK HERE. VFY. W/ OWNER FOR NEW DATA AND POWER WHICH WAS REMOVED FROM ORIGINAL CASEWORK IN THIS AREA.

AutoCAD SHX Text

EXISTING ALUMINUM DOOR TO REMAIN. PROTECT DURING CONSTRUCTION.

AutoCAD SHX Text

ALL NON FIXED SEATING SHALL BE NEW. -O.F.O.I.

AutoCAD SHX Text FURR OUT THE EXISTING WALL TO ALIGN FLUSH WITH THE EXISTING COLUMN FACE. THIS HAPPENS ON EACH SIDE OF THE ROOM.

AutoCAD SHX Text C10

AutoCAD SHX Text

PROVIDE MECHOSHADES.

AutoCAD SHX Text C11

AutoCAD SHX Text FILL IN EXISTING OPENING WITH LIKE CONSTRUCTION - COVER EACH SIDE OF WALL WITH PAINTED GYPSUM BOARD SO THAT EXIST. WALL APPEARS AS THOUGH IT NEVER HAD AN OPENING.

AutoCAD SHX Text A. REMOVE AND OR DO A ONE TO ONE REPLACEMENT FOR REMOVE AND OR DO A ONE TO ONE REPLACEMENT FOR EXISTING LIGHTING. B. PROVIDE NEW 6" STAINED OR PAINTED WOOD BASE. PROVIDE NEW 6" STAINED OR PAINTED WOOD BASE. C. PROVIDE NEW CARPET TILE. PROVIDE NEW CARPET TILE. D. REPLACE ALL NON FIXED FURNITURE. -O.F.O.I. REPLACE ALL NON FIXED FURNITURE. -O.F.O.I. E. PROVIDE NEW CEILING TILES INTO EXISTING GRID. PROVIDE NEW CEILING TILES INTO EXISTING GRID. F. OWNER SHALL PROVIDE NEW SECURITY CAMERAS AS OWNER SHALL PROVIDE NEW SECURITY CAMERAS AS REQUIRED. G. OWNER SHALL REMOVE AND RE-PULL EXISTING DATA AS OWNER SHALL REMOVE AND RE-PULL EXISTING DATA AS REQUIRED.

AutoCAD SHX Text CONTRACTOR SHALL HAVE A COORDINATION MEETING PRIOR TO BEGINNING CONSTRUCTION FOR PHASING OF PROJECT. ALL FLOORING AND SEATING SHALL BE REMOVED AND REPLACED. CONTRACTOR MAY NEED TO HAVE ACCESS TO TEMPORARY FOLDABLE SEATING FOR SPECIAL EVENTS WHICH STILL PLAN TO MEET HERE ONCE A MONTH. CONTRACTOR CAN CREATE A SMALLER MEETING AREA WITHIN THIS SPACE FOR THOSE TIMES.

AutoCAD SHX Text

COUNCIL CHAMBER FOYER

AutoCAD SHX Text

CITY COUNCIL CHAMBER

AutoCAD SHX Text

I.T. ROOM

AutoCAD SHX Text

LAW LIBRARY

AutoCAD SHX Text

BALCONY

AutoCAD SHX Text

HDWR

AutoCAD SHX Text

MAT'L

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MK

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

MAT'L

AutoCAD SHX Text

FRAME

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

JAMB

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

THRES

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text FULLY APPROVED SHOP DRAWINGS FOR DOORS, FRAMES, AND HARDWARE ARE REQUIRED PRIOR TO FABRICATION, DELIVERY OR INSTALLATION. WHEN FIRE RATED DOORS AND FRAMES ARE SPECIFIED, ANY DISCREPANCY IN THE PLANS AND SPECIFICATIONS THAT MAY RENDER A DOOR & FRAME ASSEMBLY NON-COMPLIANT SHOULD BE FULLY ADDRESSED AND RECTIFIED PRIOR TO MANUFACTURING OR INSTALLATION. DOOR & FRAME ASSEMBLIES THAT ARE FABRICATED OR INSTALLED THAT ARE NOT IN FULL COMPLIANCE FOR A SPECIFIED RATING SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

BASE

AutoCAD SHX Text

WALLS

AutoCAD SHX Text

CEILINGS

AutoCAD SHX Text C.H.

AutoCAD SHX Text

CARPET TILE

AutoCAD SHX Text

PAINT

AutoCAD SHX Text

WOOD BASE 3/4"X 6"

AutoCAD SHX Text 9'-0"

AutoCAD SHX Text

SLAT PANEL LUXE

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

(WHITE OAK)

AutoCAD SHX Text

FABRIC WRAPPED

AutoCAD SHX Text

ACOUSTICAL WALL PANELS

AutoCAD SHX Text 9'-0"

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

THIS EXIST. DOOR LISTED SHALL BE PAINTED

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

WOOD

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

THIS EXIST. DOOR LISTED SHALL BE PAINTED

AutoCAD SHX Text

EXIST.

AutoCAD SHX Text

THIS EXIST. DOOR LISTED SHALL BE PAINTED

AutoCAD SHX Text

FIRE-RATED ACOUSTIC

AutoCAD SHX Text

WOOD WALL PANELS

AutoCAD SHX Text NEW 2'x2' CEILING TILE

AutoCAD SHX Text

AND GRID

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

REFER TO

AutoCAD SHX Text

INTERIOR ELEV'S.

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

REFER TO

AutoCAD SHX Text

INTERIOR ELEV'S.

AutoCAD SHX Text 9'-6"

AutoCAD SHX Text C12

AutoCAD SHX Text WHERE A TRENCH WAS CUT INTO THE EXISTING CONCRETE FLOOR. PROVIDE (3)2"DIA. CONDUITS FROM THE PODIUM LOCATION OVER TO THE COUNCIL SEATING LOCATION. PROVIDE (5)2"DIA. CONDUITS FROM THE COUNCIL SEATING LOCATION TO THE I.T. ROOM. ONCE INSTALLED FILL THE HOLE BACK IN WITH CONCRETE WHERE CONCRETE FLOOR WAS REMOVED. CONTRACTOR DBL. CHECK AND COORDINATE W/ ARCHITECT AND OWNER PRIOR TO INSTALLING CONDUIT.

AutoCAD SHX Text C13

AutoCAD SHX Text PROVIDE A NEW ROUND SHAPED CITY OF BOSSIER CITY SEAL (6'-0"DIA.). PROVIDE BLOCKING IN WALL AS REQUIRED.

AutoCAD SHX Text C14

AutoCAD SHX Text

PAINT EXISTING LOW WALL AND MOLDING TO MATCH ALL OTHER PAINTED WOOD SURFACES.

AutoCAD SHX Text C15

AutoCAD SHX Text PROVIDE NEW ACOUSTIC SLAT WOOD WALL PANELS HERE. SHALL BE EQUAL TO SLATPANEL LUXE FIRE-RATED ACOUSTIC WOOD WALL PANEL (WALNUT)BY THE WOOD VENEER HUB sales@thewoodveneerhub.com thewoodveneerhub.com 302-216-6177

AutoCAD SHX Text

COUNCIL CONFERENCE RM.

AutoCAD SHX Text

CLERK OFFICE

AutoCAD SHX Text

HALL

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

COUNCIL OFFICE

4" RUBBER BASE

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

ELEVATION ELEVATION ELEVATION

ELEVATION ELEVATION ELEVATION

A6.1

DEMOLITION DEMOLITION DEMOLITION

(TYP.)PANEL

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.1

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.1

AutoCAD SHX Text A6.1

AutoCAD SHX Text A6.1

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

EXISTING BALCONY STRUCTURE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

EXISTING PROJECTION SCREEN ???

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

EXISTING BALCONY RAILING SHALL REMAIN

AutoCAD SHX Text

REMOVE WOOD DOOR

AutoCAD SHX Text

NEW ACOUSTICAL WALL PANELS

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

EXISTING BALCONY STRUCTURE

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

PAINTED WOOD PANELS OVER " 14" PAINTED GYP. BD.

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (PAINTED) W/DECORATIVE CONT. WALL SCONCE

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

SOFFIT

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (PAINTED)

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

REMOVE EXISTING BASE

AutoCAD SHX Text

EXISTING BALCONY RAILING SHALL REMAIN

AutoCAD SHX Text

BALCONY CENTER

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

ELEVATION ELEVATION ELEVATION

ELEVATION ELEVATION ELEVATION

A6.2

(TYP.)PANEL

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.2

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.2

AutoCAD SHX Text A6.2

AutoCAD SHX Text A6.2

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD DOOR

AutoCAD SHX Text

NEW ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

EXISTING BALCONY STRUCTURE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

REMOVE WOOD MOLDING AND DOOR SURROUND

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

EXISTING BALCONY RAILING SHALL REMAIN

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

AutoCAD SHX Text

EXISTING BALCONY STRUCTURE

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

EXISTING ALUMINUM STOREFRONT TO REMAIN- PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

EXISTING BALCONY RAILING SHALL REMAIN

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (PAINTED) W/DECORATIVE CONT. WALL SCONCE

AutoCAD SHX Text

NEW 6" WOOD BASE(PAINTED)

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

TAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

REMOVE WOOD DOOR

AutoCAD SHX Text

REMOVE WOOD DOOR

AutoCAD SHX Text

REMOVE EXISTING BASE

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text EXISTING EXIT SIGN SHALL BE REMOVED-CAP OFF WIRING IN ORDER TO INSTALL A NEW EXIT SIGN

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text EXISTING TIME OF DAY CLOCK SHALL BE REMOVED-CAP OFF WIRING IN ORDER TO INSTALL A NEW TIME OF DAY CLOCK

AutoCAD SHX Text REMOVE EXISTING LIGHTING CONTROLS-CAP OFF WIRING IN ORDER TO INSTALL NEW LIGHTING CONTROLS

AutoCAD SHX Text

FIRST AID KIT SHALL REMAIN

AutoCAD SHX Text

REMOVE EXISING GLASS AND WOOD SURROUND

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

SOFFIT

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (PAINTED) W/DECORATIVE CONT. WALL SCONCE

AutoCAD SHX Text

HVAC SUPPLY GRILL TO BE REMOVED, CLEANED, AND THEN INSTALLED BACK

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text REMOVE EXISTING LIGHTING CONTROLS-CAP OFF WIRING IN ORDER TO INSTALL NEW LIGHTING CONTROLS

AutoCAD SHX Text

FIRST AID KIT SHALL REMAIN

AutoCAD SHX Text

FILL IN HOLE WITH LIKE WALL CONSTRUCTION

AutoCAD SHX Text

ALIGN

AutoCAD SHX Text

ALIGN

AutoCAD SHX Text

NEW EXIT SIGN

AutoCAD SHX Text

NEW TIME OF DAY CLOCK - O.F.C.I.

AutoCAD SHX Text

BALCONY CENTER

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

ELEVATION ELEVATION ELEVATION

A6.3

ELEVATION ELEVATION ELEVATION

DEMOLITION DEMOLITION DEMOLITION

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text A6.3

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE ENTIRE EXISTING CORNICE STRUCTURE

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

EXISTING SHORT WALL AND ASSOCIATED MOLDING TO REMAIN-PREP FOR NEW PAINT

AutoCAD SHX Text

CEILING START HERE

AutoCAD SHX Text

CEILING START HERE

AutoCAD SHX Text

REMOVE EXISTING WOOD BASE

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

REMOVE WOOD MOLDING

AutoCAD SHX Text

EXISTING SHORT WALL AND ASSOCIATED MOLDING TO REMAIN-PREP FOR NEW PAINT

AutoCAD SHX Text

CEILING START HERE

AutoCAD SHX Text

REMOVE ENTIRE EXISTING CORNICE STRUCTURE

AutoCAD SHX Text

SOFFIT

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (PAINTED)

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

ALUMINUM COVERED COL. COVER TO REMAIN-PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

ALUMINUM COVERED COL. COVER TO REMAIN-PROTECT DURING CONSTRUCTION

AutoCAD SHX Text

NEW WALL

AutoCAD SHX Text

NEW WALL

AutoCAD SHX Text

PROVIDE WD.2X8 PAINTED CONTINUOUS AT OUTER PERIMETER

AutoCAD SHX Text

EXISTING SHORT WALL AND ASSOCIATED MOLDING (PAINTED)

AutoCAD SHX Text PROVIDE A NEW "CITY OF BOSSIER CITY" IMAGE (72"x72" (3") DEEP, SINGLE SIDED CARVED AND PAINTED HDU POLYURETHANE, SEALED. CARVED IN BASE RELIEF 3-D AND PAINTED IN COLOR OR METALLIC ENAMELS TO BE DETERMINED. SMOOTH LOWER BACKGROUND WITH 3-D CENTERED ARTWORK STATE OF LOUISIANA. FEATURES A STEEL INTERNAL SUPPORT FRAME WITH WELDED PROTRUDING, THREADED STUDS FOR EXTERIOR MOUNT WELDED PICK UP POINTS IN THE TOP OF THE SEAL FOR LIFTING. ENGINEER, DRAWING PROVIDED DURING PROOF PROCESS. - CONTACT MIKE PULLIAM WITH AGNEW SIGNS 318-355-7703 HE WILL HAVE UP TO (3)SUBS THAT CAN PRICE

AutoCAD SHX Text

NEW 6" WOOD BASE (PAINTED)

AutoCAD SHX Text

NEW FABRIC WRAPPED ACOUSTICAL WALL PANELS

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

EXISTING SHORT WALL AND ASSOCIATED MOLDING (PAINTED)

AutoCAD SHX Text

WOOD 2X6 WALL MOLDING (STAINED OR PAINTED) W/ DECORATIVE CONT. WALL SCONCE

AutoCAD SHX Text

RETAPE, FLOAT, TEXTURE, AND PAINT EXISTING GYPSUM BOARD WALL

AutoCAD SHX Text

REMOVE EXISTING ACOUSTICAL WALL PANELS

AutoCAD SHX Text

NEW ACOUSTICAL WALL PANELS

AutoCAD SHX Text

MATCH CEILING

AutoCAD SHX Text

EXISTING CEILING TIE IN

AutoCAD SHX Text

EXISTING CEILING TIE IN

AutoCAD SHX Text

EXISTING WINDOW IS COVERED UP HERE

AutoCAD SHX Text PROVIDE (1")REVEAL BETWEEN WALL PANELS-PAINT GYPSUM BOARD INSIDE REVEAL TO MATCH EVERYWHERE ELSE

AutoCAD SHX Text

EXISTING WINDOW IS COVERED UP HERE

AutoCAD SHX Text

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

AutoCAD SHX Text

NEW FIRE RATED LUXURY AMERICAN WALNUT ACOUSTIC WALL PANELING

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

CEILING START HERE

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

AutoCAD SHX Text A7.1

AutoCAD SHX Text

AutoCAD SHX Text A7.2

AutoCAD SHX Text

A7.1

U N

C

IL

C H

A M

B

ER

S

B en to n R oa d, B os si er

C ity

, L A

14A

AUGUST 2025

AS SHOWN

OF

Job

Drawn

Scale

Date

PROJECT INFO

SHEET

PROJECT

ENGINEER

ARCHITECT

REVISIONS

KEVIN@KEVINBRYANARCHITECT.COM

WORK 318-673-9980

SHREVEPORT, LOUISIANA 71101

712 TEXAS STREET

KEVIN BRYAN ARCHITECT, L.L.C.

WDR

B O

SS

IE

R C

IT

Y

M U

N

IC

IP

A

L C

O M

PL

EX

FI

N

IS

H

U

PG

R A

D

ES

A6.4

SECTION

SECTION

DEMOLITION

SECTION

AutoCAD SHX Text IF SHEET IS LESS THAN 24" x 36", IT IS A REDUCED PRINT AND IS NOT TO SCALE SHOWN.

AutoCAD SHX Text

STONE COUNTER TOP APPLIED OVER EXISTING

AutoCAD SHX Text REMOVE WD. MOULDING COMPLETELY AND ANYTHING THAT IS BACKING IT. NEED TO CLEAR OUT THIS ENTIRE AREA.

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

REMOVE WD. BASE COMPLETELY

AutoCAD SHX Text

NEW 6"X "WOOD BASE 34"WOOD BASE (PAINTED)(WHITE OAK)

AutoCAD SHX Text SLATPANEL LUXE FIRE-RATED ACOUSTIC WOOD WALL PANEL (WALNUT) BY THE WOOD VENEER HUB sales@thewoodveneerhub.com thewoodveneerhub.com 302-216-6177

AutoCAD SHX Text

WOOD BLOCKING MAX.18"O.C.

AutoCAD SHX Text

NOTCH OUT 12"SQ.

AutoCAD SHX Text

NEW LIGHT FIXTURE REFER TO DRAWING SHEETS A8.1,A8.2,&A8.3 FOR MORE INFORMATION

AutoCAD SHX Text

HOLD

AutoCAD SHX Text

BUILD TO EXIST. RAISED WD. TOP

AutoCAD SHX Text

NEW 11"X "WOOD FASCIA 34"WOOD FASCIA (PAINTED)(WHITE OAK)

AutoCAD SHX Text

STONE…

This is the start of the file's text. The full file is on GovTribe.