Freeman's_Escalator_Measurements_2016.11.10_(1).pdf

PDF 830 KB Posted

Attached to
Escalator Maintenance and Repair Services
Solicitation number
26-P-00005
Issued by
Hillsborough County, Florida

About this file

This is an escalator measurements and facility floor plan document prepared for the Tampa Convention Center in Orlando, Florida. The document contains detailed architectural drawings of Escalator 37 located in the Ballroom B side at the first level of the facility, prepared by Freeman Co. and started on July 24, 2015, by Orlando G Hurtado of SERDC. The drawings illustrate the escalator's positioning relative to surrounding areas including Ballroom A, B, C, and D, storage facilities, and administrative spaces, with specific attention to glass balustrades connecting the first and second floors. The measurements provided include balustrade height variations ranging from 0.5 inches to 0.6875 inches, ceiling heights of 8 feet 6 inches throughout the corridor, and graphic dimensions of 16.5625 inches by 525.5625 inches (43 feet 9 inches) for the metal runner.

The document serves as a technical reference for the escalator maintenance and repair services RFP (No. 26-P-00005) issued by the City of Tampa's Convention & Tourism department. It provides the facility layout and precise measurements necessary for service providers responding to the escalator maintenance contract, which covers ten Kone escalators and one wheelchair lift across multiple building locations. The floor plans include notation of equipment locations such as WFM (Wall-Mounted Fire) units, AED stations, and various structural elements, enabling prospective contractors to understand the facility's configuration and plan maintenance activities accordingly. Freeman Co. notes that while efforts were made to ensure accuracy, exhibitors and contractors are responsible for independently verifying all dimensions and architectural component locations within the facility.

View the file

Other files

File Type Posted
Escalator_Maintenance_and_Repair_Services.pdf PDF
Escalator_Maintenance_and_Repair_Services.pdf PDF
Escalator_Maintenance_and_Repair_Services.pdf PDF
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Freeman's_Escalator_Measurements_2016.11.10_(1).pdf PDF
Escalators.url URL file
Escalators.url URL file
Freeman's_Escalator_Measurements_2016.11.10_(1).pdf PDF
Escalators.url URL file
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
Escalators.png PNG image
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
ADA_Requirements.docx DOCX document
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
Escalators.png PNG image
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
Escalators.png PNG image
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
ADA_Requirements.docx DOCX document
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
ADA_Requirements.docx DOCX document
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE CORRIDOR

BALLROOM A - D, FIRST LEVEL

TAMPA CONVENTION CENTER

OPEN TO ABOVE

OPEN TO ABOVE

OPEN TO ABOVE

PBX PHONE

FIVE STAR

BUSINESS

C HANNEL

MARKETING OFFICES

FRANKLIN ST. ENTRANCE

ADMIN ISTRATION

STORAGE

ENTRANCE

UPUP

UP

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAGE

STORAGE

VENDING

UP

UP

UP UP

UP

STORAGE

BALCONY ABOVE BALCONY ABOVE

ROTUNDA

WFM

WFM

WFM

WFM

WFM

WFM

WFM

WFM

WFM

AED

WFM

TO FRONT CIRCLE DRIVE

AMBASSADOR

GAZEBO

SAIL

PAVILION

E

LE

C T.

Bay Bar & Bistro

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-37

BALLROOM

A B

ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator

C D

OPEN TO ABOVE

WFM

ESC-37

OPEN TO ABOVE

MM

FIVE STAR

BUSINESS

CHANNEL

MARKETING OFFICES

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAG

BALCONY ABOVE BALCON

ROTUNDA

AED

Bay Bar & Bistro

A

L

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

Custom

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-37

BALLROOM

A B C

RIGHT AND LEFT SIDES

ALL GLASS BALUSTRADES ON

MIRROR DIMENSIONS

ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator

NOTE:

SMALL VARIATIONS IN HEIGHT

OF BALUSTRADE EXIST FROM

.5", .5625", .6875"

ESC-37

FX FX

FIVE STAR

BUSINESS

CHANNEL

MARKETING OFFICES

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAG

FHC

8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"

8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"

BALCONY ABOVE BALCON

ROTUNDA

WFM

FX FX FX FX FX

WFM

FXFX

WFM

FX

WFM

FX

WFM

WFM

WFM

WFM

WFM

AED

Bay Bar & Bistro

525.5625"

Plexi Barricade

Plexi Barricade

Metal Runner

16.5625"

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

Custom

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-3

BALLROOM

A B C

16.5625" x 525.5625"(43'-9")

GRAPHIC SIZE IS

ESCALATOR METAL RUNNER 1st to 2nd floor Escalator

16.5625" x 525.5625"(43'-9")

GRAPHIC SIZE IS

88'-6" C. H.WFMWFM

FFXX

WFMWFM

FFXX

ESC-3-3

FF

File details come from the government source that posted it. Updated .