Freeman's_Escalator_Measurements_2016.11.10.pdf
PDF 830 KB Posted
- Attached to
- Escalator Maintenance and Repair Services
- Solicitation number
- 26-P-00005
- Issued by
- Hillsborough County, Florida
About this file
These documents are architectural floor plans and escalator specification details for Escalator 37 at the Tampa Convention Center, specifically focusing on the Ballroom B side of the first level. The three-page document, created by Freeman on 7/24/2015, provides detailed technical specifications for the escalator's glass balustrades and metal runner, including precise measurements and dimensional details. The plans show the escalator's location within the convention center's floor layout, featuring ballrooms A through D, various storage areas, administrative spaces, and surrounding facilities.
The technical drawings include multiple views and images of the escalator, with specific notes about glass balustrade heights (with small variations from .5" to .6875") and a metal runner graphic sized at 16.5625" x 525.5625" (43'-9"). The documents emphasize a disclaimer that while every effort has been made to ensure accuracy, it is the responsibility of the exhibitor to physically inspect the facility and verify all dimensions and locations. Accompanying photographs show the escalator in its installed environment, with glass side panels and a metal central runner connecting the first and second floors of the convention center.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SERVICE CORRIDOR
BALLROOM A - D, FIRST LEVEL
TAMPA CONVENTION CENTER
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
PBX PHONE
FIVE STAR
BUSINESS
C HANNEL
MARKETING OFFICES
FRANKLIN ST. ENTRANCE
ADMIN ISTRATION
STORAGE
ENTRANCE
UPUP
UP
ENTRY
CENTER
STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE
STORAGE
STORAGE
VENDING
UP
UP
UP UP
UP
STORAGE
BALCONY ABOVE BALCONY ABOVE
ROTUNDA
WFM
WFM
WFM
WFM
WFM
WFM
WFM
WFM
WFM
AED
WFM
TO FRONT CIRCLE DRIVE
AMBASSADOR
GAZEBO
SAIL
PAVILION
E
LE
C T.
Bay Bar & Bistro
EVERY EFFORT HAS BEEN MADE TO
ENSURE THE ACCURACY OF ALL
INFORMATION CONTAINED ON THIS
FLOORPLAN. HOWEVER, NO WARRANTIES,
EITHER EXPRESSED OF IMPLIED, ARE
MADE WITH RESPECT TO THIS
FLOORPLAN. IF THE LOCATION OF
BUILDING COLUMNS, UTILITIES OR OTHER
ARCHITECTURAL COMPONENTS OF THE
FACILITY IS A CONSIDERATION IN THE
CONSTRUCTION OR USAGE OF AN
EXHIBIT, IT IS THE SOLE RESPONSIBILITY
OF THE EXHIBITOR TO PHYSICALLY
INSPECT THE FACILITY TO VERIFY ALL
DIMENSION AND LOCATIONS.
© COPYRIGHT 2007, FREEMAN CO.
ALL RIGHTS RESERVED.
DRAWING INFO
BALLROOM B SIDE, FIRST LEVEL
TAMPA CONVENTION CENTER
ESCALATOR 37
Branch:
Started By:
Facility:
City & State:
Hall / Level:
Scale:
Started:
ORLANDO
G HURTADO SERDC
7/24/2015
ORLANDO, FLORIDA
BALLROOM B SIDE
FIRST LEVEL
ESC-37
BALLROOM
A B
ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator
C D
OPEN TO ABOVE
WFM
ESC-37
OPEN TO ABOVE
MM
FIVE STAR
BUSINESS
CHANNEL
MARKETING OFFICES
ENTRY
CENTER
STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE
STORAG
BALCONY ABOVE BALCON
ROTUNDA
AED
Bay Bar & Bistro
A
L
EVERY EFFORT HAS BEEN MADE TO
ENSURE THE ACCURACY OF ALL
INFORMATION CONTAINED ON THIS
FLOORPLAN. HOWEVER, NO WARRANTIES,
EITHER EXPRESSED OF IMPLIED, ARE
MADE WITH RESPECT TO THIS
FLOORPLAN. IF THE LOCATION OF
BUILDING COLUMNS, UTILITIES OR OTHER
ARCHITECTURAL COMPONENTS OF THE
FACILITY IS A CONSIDERATION IN THE
CONSTRUCTION OR USAGE OF AN
EXHIBIT, IT IS THE SOLE RESPONSIBILITY
OF THE EXHIBITOR TO PHYSICALLY
INSPECT THE FACILITY TO VERIFY ALL
DIMENSION AND LOCATIONS.
© COPYRIGHT 2007, FREEMAN CO.
ALL RIGHTS RESERVED.
DRAWING INFO
BALLROOM B SIDE, FIRST LEVEL
TAMPA CONVENTION CENTER
ESCALATOR 37
Branch:
Started By:
Facility:
City & State:
Hall / Level:
Scale:
Started:
ORLANDO
G HURTADO SERDC
7/24/2015
Custom
ORLANDO, FLORIDA
BALLROOM B SIDE
FIRST LEVEL
ESC-37
BALLROOM
A B C
RIGHT AND LEFT SIDES
ALL GLASS BALUSTRADES ON
MIRROR DIMENSIONS
ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator
NOTE:
SMALL VARIATIONS IN HEIGHT
OF BALUSTRADE EXIST FROM
.5", .5625", .6875"
ESC-37
FX FX
FIVE STAR
BUSINESS
CHANNEL
MARKETING OFFICES
ENTRY
CENTER
STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE
STORAG
FHC
8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"
8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"
BALCONY ABOVE BALCON
ROTUNDA
WFM
FX FX FX FX FX
WFM
FXFX
WFM
FX
WFM
FX
WFM
WFM
WFM
WFM
WFM
AED
Bay Bar & Bistro
525.5625"
Plexi Barricade
Plexi Barricade
Metal Runner
16.5625"
EVERY EFFORT HAS BEEN MADE TO
ENSURE THE ACCURACY OF ALL
INFORMATION CONTAINED ON THIS
FLOORPLAN. HOWEVER, NO WARRANTIES,
EITHER EXPRESSED OF IMPLIED, ARE
MADE WITH RESPECT TO THIS
FLOORPLAN. IF THE LOCATION OF
BUILDING COLUMNS, UTILITIES OR OTHER
ARCHITECTURAL COMPONENTS OF THE
FACILITY IS A CONSIDERATION IN THE
CONSTRUCTION OR USAGE OF AN
EXHIBIT, IT IS THE SOLE RESPONSIBILITY
OF THE EXHIBITOR TO PHYSICALLY
INSPECT THE FACILITY TO VERIFY ALL
DIMENSION AND LOCATIONS.
© COPYRIGHT 2007, FREEMAN CO.
ALL RIGHTS RESERVED.
DRAWING INFO
BALLROOM B SIDE, FIRST LEVEL
TAMPA CONVENTION CENTER
ESCALATOR 37
Branch:
Started By:
Facility:
City & State:
Hall / Level:
Scale:
Started:
ORLANDO
G HURTADO SERDC
7/24/2015
Custom
ORLANDO, FLORIDA
BALLROOM B SIDE
FIRST LEVEL
ESC-3
BALLROOM
A B C
16.5625" x 525.5625"(43'-9")
GRAPHIC SIZE IS
ESCALATOR METAL RUNNER 1st to 2nd floor Escalator
16.5625" x 525.5625"(43'-9")
GRAPHIC SIZE IS
88'-6" C. H.WFMWFM
FFXX
WFMWFM
FFXX
ESC-3-3
FF
File details come from the government source that posted it. Updated .