Freeman's_Escalator_Measurements_2016.11.10_(1).pdf

PDF 830 KB Posted

Attached to
Escalator Maintenance and Repair Services
Solicitation number
26-P-00005
Issued by
Hillsborough County, Florida

About this file

Escalator Maintenance and Repair Services - Tampa Convention Center

This document is an architectural floor plan prepared by Freeman Co. for the Tampa Convention Center in Orlando, Florida, specifically detailing escalator measurements and locations for Escalator 37 (ESC-37) on the Ballroom B Side, First Level. The plan was initiated by Orlando G. Hurtado on July 24, 2015, for the SERDC facility and provides precise dimensional specifications for the escalator installation, including glass balustrades, metal runners, and plexi barricades. The document indicates that the escalator measures 16.5625 inches by 525.5625 inches (43 feet 9 inches) with a ceiling height of 8 feet 6 inches in most areas and 8 feet 6 inches in others, and includes notational variations in balustrade heights ranging from 0.5 inches to 0.6875 inches. The floor plan serves as a reference document for facility exhibitors and service providers requiring accurate spatial and dimensional information for equipment installation or maintenance operations at the convention center.

The plan carries a disclaimer stating that while every effort has been made to ensure accuracy, no warranties are expressed or implied, and exhibitors or service providers are solely responsible for physically inspecting the facility to verify all dimensions and locations before undertaking any construction or usage activities. This architectural documentation is essential for the Escalator Maintenance and Repair Services RFP (No. 26-P-00005) issued by the City of Tampa's Convention & Tourism department, which seeks comprehensive maintenance services for ten Kone escalators and one wheelchair lift across multiple facility locations, with a mandatory pre-proposal conference and site visit scheduled for November 20, 2025, and proposals due by December 12, 2025.

View the file

Other files

File Type Posted
Escalator_Maintenance_and_Repair_Services.pdf PDF
Escalator_Maintenance_and_Repair_Services.pdf PDF
Escalator_Maintenance_and_Repair_Services.pdf PDF
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Exhibit_A_-_Price_Sheet.xlsx XLSX spreadsheet
Freeman's_Escalator_Measurements_2016.11.10_(1).pdf PDF
Escalators.url URL file
Freeman's_Escalator_Measurements_2016.11.10_(1).pdf PDF
Escalators.url URL file
Escalators.url URL file
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
Escalators.png PNG image
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
ADA_Requirements.docx DOCX document
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
Escalators.png PNG image
DMI-40-Form-LOI-Letter-of-Intent_SLBE.pdf PDF
Escalators.png PNG image
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
ADA_Requirements.docx DOCX document
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
26-P-00005-EBO-Determination-Letter-SLBE_-_Traditional_Bid.pdf PDF
DMI-30-Form-Payment-Package-or-Final-with_Invoices_SLBE.pdf PDF
Freeman's_Escalator_Measurements_2016.11.10.pdf PDF
ADA_Requirements.docx DOCX document
DMI-71-Form-for-RFQ-RFP-Evaluation-Points-V4-SLBE.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE CORRIDOR

BALLROOM A - D, FIRST LEVEL

TAMPA CONVENTION CENTER

OPEN TO ABOVE

OPEN TO ABOVE

OPEN TO ABOVE

PBX PHONE

FIVE STAR

BUSINESS

C HANNEL

MARKETING OFFICES

FRANKLIN ST. ENTRANCE

ADMIN ISTRATION

STORAGE

ENTRANCE

UPUP

UP

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAGE

STORAGE

VENDING

UP

UP

UP UP

UP

STORAGE

BALCONY ABOVE BALCONY ABOVE

ROTUNDA

WFM

WFM

WFM

WFM

WFM

WFM

WFM

WFM

WFM

AED

WFM

TO FRONT CIRCLE DRIVE

AMBASSADOR

GAZEBO

SAIL

PAVILION

E

LE

C T.

Bay Bar & Bistro

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-37

BALLROOM

A B

ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator

C D

OPEN TO ABOVE

WFM

ESC-37

OPEN TO ABOVE

MM

FIVE STAR

BUSINESS

CHANNEL

MARKETING OFFICES

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAG

BALCONY ABOVE BALCON

ROTUNDA

AED

Bay Bar & Bistro

A

L

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

Custom

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-37

BALLROOM

A B C

RIGHT AND LEFT SIDES

ALL GLASS BALUSTRADES ON

MIRROR DIMENSIONS

ESCALATOR GLASS BALUSTRADES 1st to 2nd floor Escalator

NOTE:

SMALL VARIATIONS IN HEIGHT

OF BALUSTRADE EXIST FROM

.5", .5625", .6875"

ESC-37

FX FX

FIVE STAR

BUSINESS

CHANNEL

MARKETING OFFICES

ENTRY

CENTER

STORAGESTORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE

STORAG

FHC

8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"

8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6" C. H. 8'-6"

BALCONY ABOVE BALCON

ROTUNDA

WFM

FX FX FX FX FX

WFM

FXFX

WFM

FX

WFM

FX

WFM

WFM

WFM

WFM

WFM

AED

Bay Bar & Bistro

525.5625"

Plexi Barricade

Plexi Barricade

Metal Runner

16.5625"

EVERY EFFORT HAS BEEN MADE TO

ENSURE THE ACCURACY OF ALL

INFORMATION CONTAINED ON THIS

FLOORPLAN. HOWEVER, NO WARRANTIES,

EITHER EXPRESSED OF IMPLIED, ARE

MADE WITH RESPECT TO THIS

FLOORPLAN. IF THE LOCATION OF

BUILDING COLUMNS, UTILITIES OR OTHER

ARCHITECTURAL COMPONENTS OF THE

FACILITY IS A CONSIDERATION IN THE

CONSTRUCTION OR USAGE OF AN

EXHIBIT, IT IS THE SOLE RESPONSIBILITY

OF THE EXHIBITOR TO PHYSICALLY

INSPECT THE FACILITY TO VERIFY ALL

DIMENSION AND LOCATIONS.

© COPYRIGHT 2007, FREEMAN CO.

ALL RIGHTS RESERVED.

DRAWING INFO

BALLROOM B SIDE, FIRST LEVEL

TAMPA CONVENTION CENTER

ESCALATOR 37

Branch:

Started By:

Facility:

City & State:

Hall / Level:

Scale:

Started:

ORLANDO

G HURTADO SERDC

7/24/2015

Custom

ORLANDO, FLORIDA

BALLROOM B SIDE

FIRST LEVEL

ESC-3

BALLROOM

A B C

16.5625" x 525.5625"(43'-9")

GRAPHIC SIZE IS

ESCALATOR METAL RUNNER 1st to 2nd floor Escalator

16.5625" x 525.5625"(43'-9")

GRAPHIC SIZE IS

88'-6" C. H.WFMWFM

FFXX

WFMWFM

FFXX

ESC-3-3

FF

File details come from the government source that posted it. Updated .