Form 807.pdf

PDF 83 KB Posted

Attached to
F-16 Electrical Limiter
Solicitation number
FA821225R0005
Issued by

About this file

This AFMC Form 807 details recommended quality assurance provisions and special inspection requirements for an F-16 Electrical Limiter with National Stock Number 5895015158924WF. The document specifies that inspection must be accomplished at the source due to significant technical requirements for manufacturing, repair, and testing of this critical F-16 component. Quality assurance provisions include standard inspection requirements under FAR 52.246-2 through 52.246-6, with the technical authority from 416 SCMS/GUMAD noting that quality provisions cannot be downgraded without coordination.

The form indicates the item manager is Stefani Peterson and the equipment specification contact is Timothy L. Nichols, both with contact numbers at Hill Air Force Base. A key note confirms that the requirement does not necessitate the use of Class I Ozone Depleting Substances. The technical authority signed the document on 08 MAR 2023, and the form was generated on 06 MAR 2025, suggesting this is part of a future procurement process for a critical F-16 electrical component.

View the file

Other files

File Type Posted
Form 260 - FA.pdf PDF
IUID.pdf PDF
Manufacturing Qualification Requirements-Section C.pdf PDF
CDRL A001 - CPP.pdf PDF
Transportation Data.pdf PDF
Engineering Data Requirements.docx DOCX document
FA821225R0005.pdf PDF
Engnieering Data List.pdf PDF
CDRL B001 - FA Test Report.pdf PDF
Item Description.pdf PDF
Packaging Requirements.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

5895015158924WF

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Peterson, Stefani / 801-586-4371

6. EQUIPMENT SPEC / PHONE

Nichols, Timothy L / 801-775-4608

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY

FOR INSPECTION

FAR 52.246-1

X STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6

AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Refahiyat, JoeNAME: 01 NOV 2010DATE:

Inspection must be accomplished at the source due to significant technical requirements for the manufacture, repair, and test of this item which is part of critical item on the F16.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE AF FARS 5323)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCENO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

C

11. SIGNATURE OF TECHNICAL AUTHORITY

Nichols, Timothy L

ORGANIZATION / SYMBOL

416 SCMS / GUMAD

PHONE

801-775-4608 / 775-4608

DATE

08 MAR 2023

Page 1 of 1AFMC FORM 807, 20060111, V1 Version 3Generated by PRPS using Jasper Reports on 06 Mar 2025