Building #636 – Sustainment Repairs August 31, 2011 Forbes Field, Topeka, Kansas HTK Project No. 0905.02- 009 D.O.F.E. Project No. T233

Amendment #002

September 12, 2011

ISSUED BY:

HTK Architects, P.A.

2900 SW MacVicar Avenue Topeka, Kansas 66611-1790 Contact: Dennis Haugh Telephone: 785-266-5373

NOTICE ALL BIDDERS FOR THE:

DOFE Project #T233, KSARNG, Bldg 636 Sustainment Repairs Solicitation Number: FMATOC-11-R-0003 Agency: Department of the Army Office: National Guard Bureau Location: USPFO for Kansas

You are instructed to read and to note the following described changes, corrections, clarifications, omissions, deletions, additions, approvals and statements pertinent to the Contract Bid and Construction Documents.

The Amendment No. 002 is a part of the Contract Bid and Construction Documents and shall govern in the performance of the Work.

Article 1-1, Section 01010 Statement of Work and General Requirements

A. Article 1.2 Alternates, C.: Shall be revised to read “Alternate No. 2: In lieu of none in the base bid, state the amount to provide metal lockers and locker benches per Specification Section 10 5113 – Metal Lockers, and as shown on the drawings.”

Article 1-2, Specification Division 9 - Finishes

B. Section 09 5113 Acoustical Panel Ceilings, 2.3A manufacturers shall be revised to add “5.

CertainTeed”.

C. 2.3B: CertainTeed “Fine Fissured High NRC HHF-454HNRC” shall be an approved equivalent product.

Article 1-3, Specification Division 12- Furnishings

A. Section 12 2413 Roller Window Shades, 3.2B, 1. Shall be revised to read ….”at all Phase I exterior windows.” ….

Article 1-4 Sheet ME1.3

A. Sheet ME1.3, Detail 2: Delete HWP-2 and all associated controls. HWP-1 and all associated controls to remain.

Building #636 – Sustainment Repairs August 31, 2011 Forbes Field, Topeka, Kansas HTK Project No. 0905.02- 009 D.O.F.E. Project No. T233

Article 1-5 Sheet E2.1

A. Lighting fixture schedule:

1. Elliptipar shall be an approved equivalent manufacturer for fixture type “E”.

2. McGraw-Edison shall be an approved equivalent manufacturer for fixture type “O”.

END OF AMENDMENT TWO