Floor Plans.pdf
PDF 168 KB Posted
- Attached to
- Sale of Galesburg Lab Property (IFB)
- Solicitation number
- 25-416CMS-BOPM4-B-44469
- Issued by
- Kendall County, Illinois
About this file
This file contains architectural floor plans showing the first and second floor layout of what appears to be a medical or laboratory facility. The first floor plan is extensive and includes specialized areas such as an autopsy room, clinical pathology, virology lab, tissue culture room, electron microscope room, isolation room, lab animals area, and various support spaces including storage rooms, mechanical rooms, bathrooms, and offices. There's also a conference room, employee lounge, director's office, and mail room.
The second floor is significantly smaller in footprint, with much of it marked as "ROOF OF FIRST FLOOR (NO SECOND FLOOR HERE)." The second floor contains a large general meeting room, small meeting room, several offices, mechanical room, men's and women's bathrooms, and storage space. There is elevator access between floors and a designated access point to the roof. The area above the autopsy room is marked as "OPEN TO AUTOPSY BELOW," indicating a two-story height in that section. Both floor plans are noted as "NOT TO SCALE" in the drawings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| EPA Clearance to backfill excavated area.pdf | ||
| B-44469 Pre-bid recording.mp4 | MP4 file | |
| EnviroServe Weekly Reports.pdf | ||
| Galesburg Laboratory Sub Plat with Legal.pdf | ||
| vendor-disclosure-(formerly-forms-a)-v.24.1-Galesburg.docx | DOCX document | |
| Pace Analytical Lab Testing-Report.pdf | ||
| B-44469 Pre-Bid Conference Attendance-No attendees.pdf | ||
| Galesburg IFB-Final 11.19.24.docx | DOCX document | |
| PSA Galesburg Draft-Final.docx | DOCX document | |
| ipg-active-registered-vendor-disclosure-(formerly-forms-b)-v.23.1-Galesburg.docx | DOCX document | |
| Q and A Template B-44469 (no questions received)~1.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLERICAL OFFICE
VESTIBULE
OFFICE STORAGE
MAIL ROOM
OFFICE
ELEVATOR
AUTOPSY
EMPLOYEE
LOUNGE
DIRECTOR'S
OFFICE
RECEIVING
ELECTRON
MICROSCOPE
MEN
BATHROOM
WOMEN
BATHROOM
CLINICAL
PATHOLOGY
WOMEN
BATHROOM
MEN
BATHROOM
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
OFFICE
OFFICE
COOLERSTORAGE
ROOM
MECH
ROOM
STORAGE
SMOKING
ROOM
PRESSURE
ROOM
DARK
ROOM
TISSUE
CULTURE
PREPARATION
MECH ROOM
VIROLOGY
STORAGE
ISOLATION ROOM
LAB ANIMALS
STORAGE
CONFERENCE
ROOM
PREP
PREP
STORAGE
GLASSWARE
ROOM
First Floor-NOT TO SCALE
MECH.
ROOM
MEN WOMEN
OPEN TO AUTOPSY BELOW
OFFICE
ELEVATOR
GENERAL MEETING ROOM
STORAGE
OFFICE
OFFICE
SMALL MEETING
ROOM
OFFICE
NO SECOND FLOOR
ROOF OF FIRST FLOOR
(NO SECOND FLOOR HERE)
ACCESS TO ROOF
Second Floor-NOT TO SCALE
| GALESBURG LAB - FLOOR 1 - NOT TO SCALE |
| Sheets and Views |
| Model |
| GALESBURG LAB - FLOOR 2 - NOT TO SCALE |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .