The document is an Excel spreadsheet detailing fire system and utility equipment for multiple facilities across Pinellas County, Florida, including water reclamation facilities, water treatment plants, pump stations, and various utility buildings in locations such as Palm Harbor, Largo, Tarpon Springs, Seminole, and St. Petersburg. The spreadsheet provides a comprehensive inventory of fire panel types, detection devices, building zones, sprinkler systems, and other fire safety infrastructure across 25 different buildings and facilities, ranging from administrative buildings to specialized utility structures like dewatering, denitrification, and maintenance facilities.

The equipment list reveals diverse fire panel manufacturers including Notifier, Silent Knight, FireLite, Cerberus Pyro, and Simplex-Grinnel, with varying detection capabilities and system configurations. Most buildings are single-story structures with different fire suppression needs, with some facilities like the Southcross Methanol Storage having specialized fire suppression systems using 3% Alcohol Resistant Concentrate (FOAM). The inventory indicates varying levels of fire protection, with some buildings having partial or no sprinkler coverage, while others like the Keller Water Treatment Facility Admin Building have a fully supervised wet pipe system with city connections and multiple check valves and backflow preventers.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Equipment List

Building AddressBuilding TypeFire Panel TypeBuilding ZonesDetection DevicesPump SizeSprinklered (Yes/No)Sprinker/Foam System DevicesStand pipe CountDeluge ValvesSuppression SystemFire Hydrants
SmokeHeatDuctPullTampersFlowsCheck ValvesBack Flow Preventer
Dunn Water Reclamation Facility- Admin Bldg 4111 Dunn Dr Palm Harbor1 storyNotifier 500129335NoneNo000000No0
Dunn Water Reclamation Facility- Dewatering Bldg 4111 Dunn Dr Palm Harbor3 storySlienbt Knight IFP-5041300NoneNo000000No0
Maintenance South
6730 142nd Ave N., Largo1 story
*Lift may be required to reach equipmentSilent Knight 520441001NonePartially Warehouse only011210Canopy sprinkled with antifreeze in system test 5 yr. Two inspector test valves, one external bell0
PC Utilities Lab 1620 Ridge Rd Largo1 storyFirelite ES-200X1223774NoneNoN/AN/AN/AN/A00No0
Keller Water Treatment Facility Electrical Bldg 3655 Keller Circle Tarpon Spring1 storyNotifier LCD8018001NoneNoN/AN/AN/AN/A00No0
Keller Water Treatment Facility Admin Bldg 3655 Keller Circle Tarpon Spring1 storyNotifier NFW2-10049026NoneYesCity Connection Locked/System Supervised1 Potter 4"2 - no name 4" / 1 - global 4" butterfly2 OS&Y size 41 Wet Pipe System Size 4"0No0
Pump Station 016 10548 Park Blvd Seminole1 storyFirelite MS-5UD13205NoneNo000000No0
McKay Creek Booster 1170 Hamlin Blvd Largo1 storyFireLite MS-10UD19107NoneNo000000No0
FOG Facility 10901 28th St N St. Petersburg1 storySilent Knight 5700111714NoneNo000000No0
Southcross Public Education Building 7401 54th Ave N St. Petersburg1 storyCerberus Pyro PXLNone21303NoneNo000000No0
Southcross Generator 1 Building 7401 54th Ave N St. Petersburg1 storyNotifier 50012610NoneNo000000No0
Southcross Generator 2 Building 7401 54th Ave N St. Petersburg1 storyNotifer 50013810NoneNo000000No0
Southcross Generator 3 Building 7401 54th Ave N St. Petersburg1 storyNotifier 50018510NoneNo000000No0
Southcross Generator 4 Building 7401 54th Ave N St. Petersburg1 storyNotifier 50015310NoneNo000000No0
Southcross Methanol Storage 7401 54th Ave N St. Petersburg outside fire suppression system Ansul- protects methanol tank area- 3% Alcohol Resistant Concentrate (FOAM)1 storyNotifier RP 10011411Noneyes110000Yes0
Southcross Denitrification Building 7401 54th Ave N St. Petersburg1 storyNotifier 50011210NoneNo000000No0
Southcross Dewat Building 7401 54th Ave N St. Petersburg1 storySilent Knight 520813308NoneNo000000No0
Southcross EQ/UV/Warehouse 2 7401 54th Ave N St. Petersburg1 storyFireLite MS-413412NoneNo000000No0
Southcross North Train Blower Building 7401 54th Ave N St. Petersburg1 storyNotifier 500101303NoneNo000000No0
Southcross South Train Blower Building 7401 54th Ave N St. Petersburg1 storyFirelite MS-10UD101402NoneNo000000No0
Southcross Dechlorination Building 7401 54th Ave N St. Petersburg1 storyFirelite MS-210300NoneNo000000No0
Southcross Storage Building/Warehouse 7401 54th Ave N St. Petersburg1 storyNotifier SFP-2404111002NoneNo000000No0
Southcross Maintenance Building 7401 54th Ave N St. Petersburg1 storyNotifier 500161033NoneNo000000No0
Southcross IPS Building 7401 54th Ave N St. Petersburg1 storyNotifier 50011011NoneNo000000No0
Southcross Operations Building 7401 54th Ave N St. Petersburg1 storyNotifier 500125833NoneNo000000No0
Cross Bar Rach Education Center, 20031 Locket Ave, Spring Hill1 storySimplex-Grinnel13008NoneNo00000No0