Final_RFB_758_2300000312_1_SO_FORM.PDF

PDF 253 KB Posted

Attached to
Body Scanners
Solicitation number
RFB 758 2300000312 2
Issued by
Kentucky

About this file

This is a solicitation form issued by the Commonwealth of Kentucky for the procurement of body scanning equipment. The solicitation, identified as RFB 758 2300000312, was issued on November 22, 2022, with a closing date of December 7, 2022, at 1:30 PM. The procurement requests eight full-body X-ray scanners, specifically SOTOR RS Full Body X-ray Scanner units or approved equivalents. Bidders proposing alternate brands or specifications must submit descriptive literature for evaluation of equivalency; failure to provide sufficient documentation may result in a non-responsive bid determination. The solicitation contact is Keith Srutowski at 502-564-7007.

The equipment specified must meet defined minimum specifications including operating temperature range of 0-45 degrees Celsius, sound pressure levels below 40 decibels in accordance with ANSI N43.17, conveyor speed capability of 0-10 miles per second, humidity tolerance of 10-90 percent non-condensing relative humidity, and X-ray inspection dosage between 0.2 and 2.5 microsieverts per inspection. Bidders should submit their responses electronically or with required signatures to avoid bid rejection. The commodity classification for this procurement is X-Ray Machines (Diagnostic) and Accessories (Except Dental) under commodity code 89880. Online bidding is permitted for this solicitation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Document ID: RFB 758 2300000312 Page: 1

Commonwealth of Kentucky

SOLICITATION

Modification: No Version #:

TITLE: Body Scanners

Date Issued:

11/22/2022 Record Date:

11/21/2022

Solicitation Closes Date:

12/07/2022 Time:

13:30

Solicitation No:

RFB 758 2300000312

Online Bidding Prohibited: No For Information Call:

Keith Srutowski 502-564-7007

Bid Receiving Location:

Bid Receiving

See Terms & Conditions for Bid Submission Instructions

Other KY

Vendor Customer Number:

Vendor Name:

Phone Number:

Fax Number:

Email Address:

Ordering

Address:

City, State, Zip:

Contact Name:

Contact Email:

Contact Phone Number:

Payment

Address:

City, State, Zip:

Contact Name:

Contact Email:

Contact Phone Number:

Ownership Type

__ Sole Proprietorship __ Partnership __ Corporation __ Other_________________________

SIGNATURE OF AUTHORIZED AGENT IS REQUIRED UNLESS RESPONSE

IS SUBMITTED ELECTRONICALLY. FAILURE TO SIGN SHALL RENDER

THE BID INVALID.

Signature X_________________________________________ FEIN#____________________ Date____________

All offers subject to all terms and conditions contained in this solicitation.

Document ID: RFB 758 2300000312 Page: 2

Line Items

Commodity Group: Default Commodity Group

Line CL Description Quantity UOM Unit Cost Line Total or Contract Amnt

1 Full Body X-Ray Scanner 8.00000 EA

Comm Code Comm Description Manufacturer Model # Manuf Part #

89880 X-Ray Machines (Diagnostic) and Accessories (Except Dental)

Extended Description Body Scanners - SOTOR RS Full Body X-ray Scanner or Approved Equal

Bidders who propose alternate brands/specifications should enclose descriptive literature with their bids so that the equality can be verified. Failure to enclose sufficient literature may result in a non-responsive bid. If the brands are not changed, the contract will be written accordingly and the successful bidder shall be required to deliver the brand/specification stated in the solicitation.

Minimum Specifications:

Operating Temperature: 0-45 Celsius Sound Pressure Level < 40 DB ANSI N43.17 complaint Conveyor Speed: 0, 10 mis Humidity: 10% to 90% non-condensing RH X-ray inspection dose/inspection 0,2 uSv up to 2,5 uSv Start-up time <2 min Image resolution 2432 x 4450 (V x H) px Prison Rape Elimination Act Compliant Software Features: Multiple report functions, encryption, data import & export. All data shall be stored on local servers 46 AWG Rating Linear detector configuration to prevent image distortion Radiation not to go beyond the footprint of the machine Single x-ray generator

Quantity - 1 per location

Price is to include all shipping charges.

SEE ATTACHMENT A FOR LOCATIONS

Shipping Information Department of Juvenile Justice

1025 Capital Center Dr Bldg #3 - 3rd Floor Frankfort KY 40601

Billing Information DJJ - Fiscal Branch

1025 Capital Center Drive Bldg #3 - 3rd Floor Frankfort KY 40601

Document ID: RFB 758 2300000312 Page: 3

Submission Checklist

The following items will be required to be submitted with bid:

Item Bid Information-Completed Best Price Best Delivery

See “Attachment A” for Terms and Conditions. The terms and conditions set out in “Attachment A”, and any subsequent addenda, are incorporated into and are a part of the Solicitation.

By signing the face of the Solicitation document, the vendor affirms that they have read and understood the Solicitation and the terms and conditions (Attachment A) and any subsequent addenda. Should the vendor fail to comply with the provisions of the Solicitation and the terms and conditions (Attachment A) and any subsequent addenda, then the Finance and Administration Cabinet reserves the right and retains the ability to deem the vendor ineligible from further participation in the Solicitation in question.

Document Description Page 4

2300000312 Body Scanners

File details come from the government source that posted it. Updated .