.0
.0
.0
.5
4.00"
5.98"
1 MG-30 LIR TOWER - DME
DME POWER & RF J-BOX
NOT TO SCALE
Q002
B
Q002
NOT TO SCALEQ002
TOP CAP
DME ANTENNA
Q002
NOT TO SCALE
A
6 ANCHOR PLATE
NOTES:
B
Q001
S001
.5
(GFM)
3.25" DIA.
DME ANTENNA
OB LIGHT
GROUND ROD
BY 12" TALL (GFM)
COLLAR 8" DIA
A
NOT TO SCALEQ002
MG-20 (TILT DOWN) W/ DME
Q001
(TILT-DOWN) FRAME
MG-30 MOUNTING4
STABILIZER RODS
MG-20 LIR TOWER
FOUNDATION
AROUND ENTIRE
GEOTEXTILE FABRIC
PACK OVER
6"LAYER OF HARD
FINISHED GRADE
S001
MG-30 FOUNDATION PLAN
STRUCTURE FOR DME ANTENNA X 20' TALL)
(JAQUITH INDUSTRIES L4030INX INVERTED STYLE SUPPORT
TOP CAP (GFM)
TURNBUCKLE, 1/2" X 6" TAKE-UP
GALVANIZED STEEL
LOCKNUT
HEX HD BOLT WITH HEX
5/8"-11 X 2 1/2" LG
DME RF J-BOX
NEMA 4X
18" x 16" x 8"
(2 PLS)
2" GRSC
2" GRSC
2" COUPLING
IN FOUNDATION
2" GRSC SWEEP
2" COUPLING
& RF J-BOX
DME PWR
JUNCTION BOX
18"x16"x8" NEMA 4X (NON-METALLIC)
E D
M
IS
S
U E
D F
O R
NAVAIDS
NH
MB
MB 04/20/2020 1801792
C O
N S
T R
U C
T
IO
N
ENGINEERING SERVICES
DME
PROJECT ENGINEER MGR: ENGINEERING CENTER
THIS DRAWING PRODUCED ON NEW ENGLAND REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
W/ 4/0 BARE CU
1" PVC
COUNTERPOISE
4/0
BERLIN REGIONAL AIRPORTBERLIN
AND ELECTRICAL DRAWINGS FOR INTERIOR GROUNDING REQUIREMENTS.
ONLY EXTERIOR GROUNDING IS SHOWN: REFER TO EQUIPMENT INSTALLATION
SURFACE AND SUBSURFACE EARTH MATERIAL RENDERED TRANSPARENT.
3. SITE GROUNDING DETAILS ON THIS DRAWING ARE SHOWN WITH ALL
LIGHT IS APPROXIMATE 28.0 FEET.
2. DME OVERALL HEIGHT FROM GRADE TO TOP OF OBSTRUCTION
WELDED UNLESS OTHERWISE INDICATED.
1. ALL UNDERGROUND GROUND CONNECTIONS ARE EXOTHERMICALLY
TO LIR MAST
2 1-1/2" LIQUIDTIGHT
C
Q002
SEE DETAIL
C
NOT TO SCALEQ002
BASE SQUARE JUNCTION BOX
LIR MAST
SQUARE JUNCTION BOX
MG-30 MOUNTING FRAME
JUCTION BOX
18" X 16" 8" NEMA 4X
FLEX CONDUIT TO
2 - 1-1/2" LIQUIDTIGHT
2 - 1-1/2" NIPPLE
2- 1 1/2" LIQUIDTIGHT
DME EQUIPMENT INSTALLATION
BML-1801792-Q002
04/12/2020180179204/20/2020
INSTALL DME
CONSTRUCTION, DT# 18811
b m l- -q
.d g n b m l- -q
.d g n
/2
/2
:2
:5
P
M P lo tt e d b y S
R V
C -C
A E
G -E
D M
S -C
O O
R D
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A bml-1801792-q002
| 2020-04-20T14:28:53-0400 | |
| STEVEN J FINNERTY |
| 2020-04-20T13:31:31-0400 | |
| MARK BOYLE |