About this file
This document includes a floor plan layout overview and specifications for a carpet replacement project at Kirtland Air Force Base, New Mexico. The contractor shall furnish all materials, labor, equipment and supervision necessary to move furniture, remove existing carpet and cove base, and install new carpet tiles, luxury vinyl tile and cove base in rooms 317 to 337, 341, 342, 345, 346, 347, 350 to 357, 360 to 366, 369 to 387 of Building 24499. The project also provides area measurements for three groups, images of different wall base styles, and details the solicitation number and opportunity type as a solicitation from the Department of the Air Force Materiel Command Nuclear Weapons Center.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combined synopsis solicitation Revision 3.pdf | ||
| AFCFS and IFS for KAFB.pdf | ||
| Combined synopsis solicitation Revision 2.pdf | ||
| Questions and Answers.pdf | ||
| Combined synopsis solicitation Update.pdf | ||
| SCA.pdf | ||
| Layout_Redacted.pdf | ||
| Wage Determination.pdf | ||
| Combined synopsis solicitation.pdf | ||
| SOW_B24499_3rdFloor_AFIA_with_Attachment.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Permanent and High Wall Layout Overview
Studded Walls (Image 1)
Modular High Walls (Older Style, Image 2)
Walls removed
Modular High Walls (Newer Style, Image 3) Modular High Walls (Newest Style)
Areas not being refloored
Install Laminate
Entire floor remove old carpet and Install new carpet except as shown
Group 1 Area Measurements
25’ 0”
’ 0
’ 6
’ 2
¾
6’
” 15’ 11 ½”
’ 3
13’ 9”
2’
19’ 10 ¼”
30’ 9 ¼”
9’ 11” 9’ 8”
’ 1
0”
’ 2
¼
14’ 4”
’ 1
0”
16’ 10”
10’
5’
’ 7
14’ 7” 16’ 5 ½”
’ 8
9’
1”
9’
¼
24’ 2”
48’ 2”
’ 1
0”
7’4’ 11”
104’
Foyer
4’ 9”
6’
½
9’
½
18’ 5½”
Group 2 Measurements
21’ 3”
’ 0
’ 5
10’ 8 1/4”
31’ 10”
’ 5
8’
’ 9
¼
109’ 4 ½”
16’ 7 ¼”
’ 8
½
’ 1
¼
’ 4
’ 1
¾
’ 4
¾
16’ 1 ½”
30’ 3”
11’ 7”
’ 7
’ 4
’ 1
½
9’ 8”
3’ 9”
4’ 6 ¾”
3’ 3 ¼”
18’ 11 ½”
’ 1
½
10’
Group 3 Area Measurements
’ 1
0”
9’ 6”
5’ 7¼”
’ 2
’ 5 ½
’ 1 ¼
’ 2 ¼
’ 2 ¼
’ 2
¼
16’ 11” 18’ ¾”15’ 1”
50’ 9½”
44’ 4”
75’ 9¼”
24’
’ 8
½
18’ 5½”
25’
10’ 11”
10’
9’ 1”
16’ 5¼”14’ 6½”
’ 7
½
20’ 4”
6’
53’ 10”
15’ 4”
’ 4
Wall Base Images Image 1 – Studded Wall
Image 2 – Older Modular Wall
Image 3 – Newer Modular Wall
| Permanent and High Wall Layout Overview |
| Group 1 Area Measurements |
| Group 2 Measurements |
| Group 3 Area Measurements |
| Wall Base Images |
File details come from the government source that posted it. Updated .