This document contains system configuration information for two NetApp storage systems along with details of a related federal contract opportunity for extended warranty and support services. The opportunity issued by the Department of the Air Force Materiel Command Test Center includes lines for extended hardware warranty support, NetApp software support plans, supplemental support management, non-returnable disks plus renewal, next business day onsite support, and warranty extensions for the two NetApp systems identified in the configuration information. Pricing is being solicited for the various warranty, support, and management services required to maintain the systems over the contract period. The combined synopsis and solicitation document as well as sample contract are attached for reference.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Synopsis-Solicitation NetApps Mod 3.docx | DOCX document | |
| Questions and answers V2.docx | DOCX document | |
| Synopsis-Solicitation NetApps Mod 2.docx | DOCX document | |
| Questions and answers.docx | DOCX document | |
| Synopsis-Solicitation NetApps Mod 1.docx | DOCX document | |
| Solicitation - FA930022Q6006.pdf | ||
| Synopsis-Solicitation NetApps.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
xxxxx-san::> version NetApp Release 9.5P4: Tue May 07 03:16:26 UTC 2019 san::> system node show Node Health Eligibility Uptime Model Owner Location san-01 true true 2 days 08:02 FAS8200 san-02 true true 2 days 08:02 FAS8200 2 entries were displayed.
san::> run -nodesan-01 -command sysconfig -A NetApp Release 9.5P4: Mon May 6 23:18:30 EDT 2019 System ID: 0538033448 (san-01); partner ID: 0538033567 (san-02) System Serial Number: 721915000190 (san-01) System Rev: A4 System Storage Configuration: Multi-Path HA System ACP Connectivity: Inband Active All-Flash Optimized: false Capacity Optimized: false Backplane Part Number: 111-02495 Backplane Rev: A4 Backplane Serial Number: 021901003170 slot 0: System Board Model Name: FAS8200 Processors: 16 Processor type: Intel(R) Xeon(R) CPU D-1587 @ 1.70GHz Memory Size: 131072 MB Memory Attributes: Hoisting Rank Interleaving Channel Interleaving Chipkill ECC Controller: A TPM FW Version: 0005.003E Service Processor Status: Online slot 0: Internal 10/100/1000 Ethernet Switch Wrench: auto-1000t-fd-up Device Type: 88E6176 slot 0: Gigabit Ethernet I210 e0M MAC Address: 00:a0:98:fe:27:32 (auto-1000t-fd-up) slot 0: 10 Gigabit Ethernet Controller IX5-SFP+ e0a MAC Address: 00:a0:98:fe:27:22 (auto-10g_twinax-fd-up) e0b MAC Address: 00:a0:98:fe:27:23 (auto-10g_twinax-fd-up) slot 0: 1/10 Gigabit Ethernet Controller IX4-T e0c MAC Address: 00:a0:98:fe:27:24 (auto-unknown-fd-up) e0d MAC Address: 00:a0:98:fe:27:25 (auto-unknown-fd-down) slot 0: 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2) e0f MAC Address: 00:a0:98:fe:27:27 (auto-unknown-fd-down) e0e MAC Address: 00:a0:98:fe:27:26 (auto-unknown-fd-down) e0h MAC Address: 00:a0:98:fe:27:29 (auto-unknown-fd-down) e0g MAC Address: 00:a0:98:fe:27:28 (auto-unknown-fd-down) slot 0: PLX DMA Engine 2 (PLX87d0) State: Active slot 0: Interconnect HBA: Generic OFED Provider Port Name: ic0a GID: fe80:0000:0000:0000:0000:0000:0000:0104 slot 0: NTB Interconnect (PLX87b0) Max HW Data Rate: PCIe Gen 3 x 8 HW Data Rate: PCIe Gen 3 x 8 SW Data Rate: PCIe Gen 3 x 8 Logical Link: Up Port State: Enabled slot 0: SAS Host Adapter 0a 12 Disks: 20562.2GB 1 shelf with IOM12 slot 0: SAS Host Adapter 0b 40 Disks: 372971.6GB 1 shelf with IOM12 slot 0: SAS Host Adapter 0c 40 Disks: 372971.6GB 1 shelf with IOM12 slot 0: SAS Host Adapter 0d 12 Disks: 20562.2GB 1 shelf with IOM12 slot 0: Fibre Channel Target Host Adapter 0e slot 0: Fibre Channel Target Host Adapter 0f slot 0: Fibre Channel Target Host Adapter 0g slot 0: Fibre Channel Target Host Adapter 0h slot 0: Intel BDW SATA Controller u0a (0x90511000) boot0 SV9MST6D120GLM41NP FW1122 114473MB 512B/sect (SPG190405J8) slot 0: Intel USB EHCI Adapter u0b (0x90512000) slot 1: FC Host Adapter 1a slot 1: FC Host Adapter 1b slot 1: Fibre Channel Target Host Adapter 1c slot 1: Fibre Channel Target Host Adapter 1d slot 3: Flash Cache NVMe Serial Number: S3K6NX0KA02107 Part Number: 119-00329 Hardware Revision: A0 Firmware Version: NA01 Model Name: X3311A Capacity: 1024 GB State: ok sysconfig: There are no configuration errors.
Device HA SHELF BAY CHAN Disk Vital Product Information 0c.21.0 0c 21 0 SA:A 2YK1PUND 0b.21.1 0b 21 1 SA:B 2YK2235D 0c.21.2 0c 21 2 SA:A 2YK1PWDD 0b.21.3 0b 21 3 SA:B 2YK1DE2D 0c.21.4 0c 21 4 SA:A 2YK16KED 0b.21.5 0b 21 5 SA:B 2YK1TR6D 0c.21.6 0c 21 6 SA:A 2YK1S30D 0b.21.7 0b 21 7 SA:B 2YK1S0AD 0c.21.8 0c 21 8 SA:A JEJ63G3N 0b.21.9 0b 21 9 SA:B JEHWKJJN 0c.21.10 0c 21 10 SA:A JEJ64TBN 0b.21.11 0b 21 11 SA:B JEJ62NDN 0c.21.12 0c 21 12 SA:A 2YK1RL3D 0b.21.13 0b 21 13 SA:B 2YK22K9D 0c.21.14 0c 21 14 SA:A 2YK13YKD 0b.21.15 0b 21 15 SA:B 2YK1TBWD 0c.21.16 0c 21 16 SA:A 2YK222SD 0b.21.17 0b 21 17 SA:B 2YK1MB2D 0c.21.18 0c 21 18 SA:A 2YK0KJUD 0b.21.19 0b 21 19 SA:B 2YJYZNHD 0c.21.20 0c 21 20 SA:A JEJ71V7N 0b.21.21 0b 21 21 SA:B JEJ61M9N 0c.21.22 0c 21 22 SA:A JEJ69G1N 0b.21.23 0b 21 23 SA:B JEJ62G1N 0c.21.24 0c 21 24 SA:A JEK60R5N 0b.21.25 0b 21 25 SA:B 2YK1RZ7D 0c.21.26 0c 21 26 SA:A 2YK1WDVD 0b.21.27 0b 21 27 SA:B JEK5AZDN 0c.21.28 0c 21 28 SA:A JEK5VZDN 0b.21.29 0b 21 29 SA:B JEK62WPN 0c.21.30 0c 21 30 SA:A JEK638SN 0b.21.31 0b 21 31 SA:B JEK5ZKSN 0c.21.32 0c 21 32 SA:A JEJ6E6AN 0b.21.33 0b 21 33 SA:B JEK6DGHN 0c.21.34 0c 21 34 SA:A 2YK1RDYD 0b.21.35 0b 21 35 SA:B JEJ6377N 0c.21.36 0c 21 36 SA:A JEK6DHUN 0b.21.37 0b 21 37 SA:B 2YK1DVMD 0c.21.38 0c 21 38 SA:A 2YK1RH9D 0b.21.39 0b 21 39 SA:B JEJUNX2N 0a.11.0 0a 11 0 SA:A W3Z23NNW 0d.11.1 0d 11 1 SA:B W3Z22DPX 0a.11.2 0a 11 2 SA:A W3Z22R7B 0d.11.3 0d 11 3 SA:B W3Z22W0C 0a.11.4 0a 11 4 SA:A W3Z23NKV 0d.11.5 0d 11 5 SA:B W3Z23MXM 0a.11.6 0a 11 6 SA:A W3Z23N3T 0d.11.7 0d 11 7 SA:B W3Z22DVR 0a.11.8 0a 11 8 SA:A W3Z23DC5 0d.11.9 0d 11 9 SA:B W3Z1X485 0a.11.10 0a 11 10 SA:A W3Z22QE3 0d.11.11 0d 11 11 SA:B W3Z23MYZ volume aggr0_sat_edi_san_01 (1 RAID group):
group 0: 3 disks volume san_01_NL_SAS_1 (1 RAID group):
group 0: 18 disks Aggregate aggr0_ san_01 (online, raid_dp) (block checksums) Plex /aggr0_ san_01/plex0 (online, normal, active, pool0) RAID group /aggr0_ san_01/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) dparity 0a.11.0 0a 11 0 SA:A 0 SAS 10000 1713523/3509295616 1716957/3516328368 parity 0d.11.1 0d 11 1 SA:B 0 SAS 10000 1713523/3509295616 1716957/3516328368 data 0a.11.2 0a 11 2 SA:A 0 SAS 10000 1713523/3509295616 1716957/3516328368
Aggregate san_01_NL_SAS_1 (online, raid_tec) (block checksums) Plex / san_01_NL_SAS_1/plex0 (online, normal, active, pool0) RAID group / san_01_NL_SAS_1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) tparity 0c.21.0 0c 21 0 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 dparity 0c.21.2 0c 21 2 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 parity 0c.21.4 0c 21 4 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.6 0c 21 6 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.8 0c 21 8 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.10 0c 21 10 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.12 0c 21 12 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.14 0c 21 14 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.16 0c 21 16 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.18 0c 21 18 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.20 0c 21 20 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.22 0c 21 22 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.24 0c 21 24 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.26 0c 21 26 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.28 0c 21 28 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.30 0c 21 30 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.32 0c 21 32 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 0c.21.34 0c 21 34 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848
Pool1 spare disks (empty)
Pool0 spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) Spare disks for block checksum spare 0a.11.4 0a 11 4 SA:A 0 SAS 10000 1713523/3509295616 1716957/3516328368 spare 0d.11.3 0d 11 3 SA:B 0 SAS 10000 1713523/3509295616 1716957/3516328368 (not zeroed) spare 0d.11.5 0d 11 5 SA:B 0 SAS 10000 1713523/3509295616 1716957/3516328368 spare 0c.21.36 0c 21 36 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 spare 0c.21.38 0c 21 38 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848
Partner disks