TAB 12 - RFP Questions and Answers 25 June 09.doc
DOC document 23 KB Posted
- Attached to
- Advanced Command Destruct System
- Solicitation number
- FA9201-09-R-0141
About this file
Q A 7-8 25 Jun 2009
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Response to Questions FA9201-09-R-0141.docx | DOCX document | |
| Legacy equipment interface requirements.ppt | PPT presentation | |
| TAB 12 - FA9201-09-R-0141 Amendment 0001 9 Jun 09.pdf | ||
| TAB 12 - Questions and Answers 1-6 8 Jun 09.doc | DOC document | |
| TAB 12 - FA9201-09-R-0141 RFP 15 MAY 09.pdf | ||
| DD1494.doc | DOC document | |
| DD Form 1494 Prep Guide 07-06.doc | DOC document | |
| IRIG Standard 200-04.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Question 7: What is the required power input to drive the amplifiers at full 1KW output?
Answer 7: The Model SYS1021, 1000 Watt amplifier system, is designed to amplify a signal in the 370 MHz to 450 MHz range from a nominal input of 1 milliWatt (0 dBm) to an output of 1000 Watts (60 dBm).
Question 8: Monitors display the health of the system i.e.. low power, low voltage, over temperature etc. What is monitored and what are the voltage levels (indications) for these monitor points?
Answer 8: The Controller monitors the power supply via the J10 connection, it monitors Current and Voltage (indication- zero to four volt DC signals). It monitors power supply fault (where zero volts represent a fault). It monitors power supply enable or disable. The Power supply has a voltage meter (30 volts is full scale) and current meter (full scale is 300 Amps). A Faulty power supply is simply indicated by a red LED.
Q&A 7-8