Atch_07,_FA9101-19-R-2002_QnA.pdf
PDF 56 KB Posted
- Attached to
- Navigation Warfare (NavWar) IDIQ II Federal contract opportunity
- Solicitation number
- FA9101-19-R-2002
About this file
Atch 07, FA9101-19-R-2002, Questions and Answers
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Atch_01,_FA9101-19-R-2002,_DO_01,_Offer_Information.xlsx | XLSX spreadsheet | |
| Atch_03,_FAR,_DFARS,_AFFARS_Prov_and_Clauses.pdf | ||
| Atch_06,_Brand_Name_J&A,_Amd_1,_Redacted.pdf | ||
| 1_FA9101-19-R-2002,_Combined_Synopsis_Solicitation,_Amd_1.pdf | ||
| Atch_05,_NavWar_II_Ordering_Guide.pdf | ||
| Atch_04,_Evaluation_Plan.pdf | ||
| Atch_01,_FA9101-19-R-2002,_DO_01,_Offer_Information.xlsx | XLSX spreadsheet | |
| 1_FA9101-19-R-2002,_Combined_Synopsis_Solicitation.pdf | ||
| Atch_03,_FAR,_DFARS,_AFFARS_Prov_and_Clauses.pdf | ||
| Atch_02,_Requirements_Document.pdf | ||
| Atch_06,_Brand_Name_J&A,_Redacted.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS AIR FORCE TEST CENTER (AFMC)
EDWARDS AIR FORCE BASE CALIFORNIA
September 6, 2019
MEMORANDUM FOR WHOM IT MAY CONCERN
SUBJECT: FA9101-19-R-2002, Navigation Warfare (NavWar) IDIQ II, Questions and Answers
1. CLIN 0005, Antcom, Antenna 60x60 (PBJ): Antcom Corporation stated model Conical- L IL2R-XN-4-R-1KW is no longer available for purchase. Can the Government verify the part and model?
a. The Government has confirmed Antcom no longer manufactures this item.
b. The required antenna is currently manufactured and sold through Matterwaves
Antenna Technology. The part number is MAT-4.5CGNSS-LP-N-4-1KW.
c. All solicitation documents have been updated to reflect this change.
2. CLIN 0006, Micronetixx Antenna 30x30 (HPJ-II): The part number you have listed calls out the number 37911-502 but the upgraded revision that is 37911-504. Should this new part number be utilized?
a. Yes, please utilize the new number.
b. Solicitation documents have been updated accordingly.
3. CLIN 0015, Crash Cart Adapter: The salient characteristic for the crash cart adapter call for “Ultra high resolution to support up to 1920x12 @ 600Hz.” All of the KVM Console Crash Cart Adaptors I could find that meet the requirement are calling out 1920x1200 @ 60Hz. Is 600Hz a typo?
a. Yes, 600Hz is a typo; 60Hz is the correct requirement.
4. CLIN 0021, Generators: Previous requirements have called for the following generator options: “Outriggers and Spare Tire” and “Spare Tire Mount and Jack Option”. Will the Government require these options for the generators?
a. Yes, the Government will require these options.
5. CLIN 0027, Freewave Modems, FGBR-115RC-2: The Requirements Document calls out
FGBR-115RC-2. Previous requirements have include numerous options not listed. Will the Government require those options?
a. Yes, the Government will require these options.
6. CLIN 0032, Rack shelf, sliding: Does the Government require a vented or a solid shelf?
a. The Government requires a vented shelf.
7. CLIN 0033, Keysight Signal Generator, N5172B: The Requirements Document calls out model N5172B for the Keysight signal generator; this is the basic model. Based on items provided in the past, there are a number of options not listed for the Keysight product.
There is a substantial difference in price from the base model to the base model with options. Please clarify if you only want the base model?
a. The Government requires the base model with applicable options.
8. CLIN 0033, Keysight Signal Generator, N5172B: Keysight identified a high power option (-099 identifier) that does not appear to be in the requirements. Does the Government require this option?
a. No, the Government does not require this option.