Asbestos APTU wiring.pdf

PDF 23 KB Posted

Attached to
High Bay Lighting Bldg 579 Federal contract opportunity
Solicitation number
FA9101-09-B-0002
Issued by
Department of the Air Force Materiel Command Test Center

About this file

Asbestos Survey

View the file

Other files for this federal contract opportunity

Other files attached to High Bay Lighting Bldg 579, newest first.
File Type Posted
Pre Bid Questions —
VHT33606 E2.pdf PDF
Amendment 1.pdf PDF
VHT33606.E4.pdf PDF
sitevisit.doc DOC document
Wage Determination.pdf PDF
12483-09-001 APTU High Bay Lighting Spec-Dwgs.pdf PDF
FA9101-09-B-0002.pdf PDF
sf24.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MEMORANDUM

Date: 19 November 2008 Organization Mail Stop

To: Mark Gifford, Project Manager ID20 1400

From: Bill Sizemore, SHG SH11 7000

Subject: Asbestos Survey: APTU High Bay Lighting System Wiring

File No: SH-09-029 Ref: CDRL OT-2003-30089

At the request of Mark Gifford, Bill Sizemore of the Industrial Hygiene department performed an asbestos survey on the wiring supplying the lighting in the high bay area of APTU, Building 579 on 19 November 2008.

Incandescent and mercury vapor light fixtures, transformers, conduits, and associated junction boxes were visually checked during the survey.

Findings/Recommendations:

1. The incandescent and mercury vapor light fixtures contained only vinyl insulated wiring.

2. Conduit and junction boxes contained only vinyl insulated wiring.

3. The transformers have vinyl insulated wiring entering and exiting the units, but the interior contains several white fibrous coated wires which are to be treated as asbestos. Many, but not all of the transformers have been bypassed to convert the mercury vapor fixtures to incandescent use. If the transformers are to be removed as a complete unit, the wiring may be cut on either side and contact with the asbestos wiring will not be necessary.

The above components were randomly inspected to provide a representative sample of the composition of the lighting system. If, during actual replacement of the lighting system, suspect materials are discovered, please contact Bill Sizemore at Ext. 5538 for additional support.