MACH1 Q_A_Comments Final AOI_12NOV26.xlsx

XLSX spreadsheet 24 KB Posted

Attached to
MACH1_AOI_FA890327M1006_F-47 Future Campus at Nellis AFB
Solicitation number
FA890327M1006
Issued by

About this file

This file is a Questions and Answers (Q&A) document addressing clarifications on the Phase 1 submission requirements for the MACH1 Area of Interest (AOI) F-47 Future Campus at Nellis Air Force Base Progressive Design-Build opportunity. The document provides government responses to 11 substantive inquiries submitted by potential respondents regarding eligibility, submission instructions, and documentation requirements.

Key clarifications include: the schematic design firm will be identified during Phase 2 interviews; CMMC Level 2 capability requirements apply per the AOI but construction trade partners' applicability differs from design firms; no Nevada prime contractor license is required; no facility clearance is required for the prime contractor; newly formed joint ventures do not need SAM registration and UEI at Phase 1 submission (November 18, 2026) but must provide UEI within one business day of Phase 3 RPP selection notification (December 22, 2026) or risk rescission; organization charts should be firm-level only without key personnel identification; each Designer-of-Record JV member and A-E subconsultant may submit up to three one-page project qualification sheets; multi-project programs supporting a single mission may be described as a single project reference; project qualification sheets are limited to one page per project with no exceptions; Nevada-licensed civil and electrical PE confirmation is sufficient for Phase 1 without names or license numbers; and airfield pavement construction project sheets are only required if the respondent is proposing design and construction of the airfield. The document is dated November 12, 2026, prior to the November 18, 2026 Phase 1 submission deadline.

View the file

Other files

File Type Posted
MACH1 Q_A_Comments Final AOI_4 NOV 26.xlsx XLSX spreadsheet
Nellis_F47_MACH1_AOI_Attachment_F_Commercial_Pricing_V1.docx DOCX document
FINAL_Nellis_F47_MACH1_AOI_30OCT26_V1.docx DOCX document
MACH1 Q_A_Comments Draft AOI Comments_28OCT26.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A

#DocumentPage #Paragraph /Figure
NumberReference Description/BackgroundQuestion/Comment/Proposed Resolution(s)Government Response
Q1SAM.gov Draft DescriptionN/APre-AOI program informationRequest identifies the existing schematic-design firm; the Final AOI refers to PCRs and existing planning information but does not identify that firm.Who is the schematic design firm?The Government takes no exception to sharing this information and will do so in the Phase 2 Interview request for down-selected Vendors.
Q2Final AOI11§4.2 Cybersecurity and Other Eligibility RequirementsThe AOI requires CMMC Level 2 capability for participating A-E organizations handling CUI and discusses shared compliant environments. Construction trade-partner applicability should be distinguished from design-firm requirements.Do all subs need to be CMMC II or just the A/E firm and Prime?Please refer to the AOI for that information.
Q3Final AOI11§4.1 EligibilityEligibility permits individual firms, JVs, and other teaming arrangements. No express Phase 1 Nevada prime-contractor license requirement was located; the Government response clarifies this.Does the prime contractor need a contractor’s license in Nevada?No.
Q4Final AOI11§4.1 Eligibility; §4.2 Cybersecurity and Other Eligibility RequirementsThe AOI does not expressly impose a prime facility clearance (FCL) requirement. Security/CUI handling obligations are separately addressed.Is an FCL required for the prime contractor?No.
Q5Final AOI12§4.3 Phase 1 Submission Instructions, Cover SheetThe Final AOI asks for the legal respondent and SAM UEI on the cover. The Government response permits later registration but imposes a Phase 3 notification deadline; confirm whether the AOI should be amended.For a newly formed joint venture proposing as the prime respondent, must the JV have its own SAM Unique Entity Identifier (UEI) and active SAM registration at the time of the November 18 Phase 1 submission, or may these be finalized before negotiations or initial award?The prime proposer, whether a JV or a single entity, does not need to identify its UEI and active SAM registration by 18 NOV 26 Phase 1 submission; however, the UEI must be active and provided at time of notification of Phase 3 RPP selection. If the UEI is not provided within 1 business day of Phase 3 notification, currently scheduled for 22 DEC 26, the Government will put that Vendor's information in the MACH1 portal for future consideration in the Nellis program but will work to find alternate approach or rescind the Phase 3 RPP selection for Milestone 2. The Government will not risk delay to Milestone 2 award pending UEI registration.
Q6Final AOI14§4.4.1 Appendix A - Organization ChartRequires one 11 x 17 firm-level chart identifying prime/JV/PCEF firms, responsibilities, A-E firms, facilities, design disciplines and contracting tiers. Named personnel are not expressly required.For Appendix A, is the government requesting a firm-level organization chart identifying contractual relationships, assigned facilities, and execution responsibilities, or should the chart also identify key personnel and individual reporting relationships?The Government is requesting a firm-level organization chart. The chart does not need to identify key personnel. Relationships between firms and their roles and responsibilities should be clearly defined.
Q7Final AOI14§4.4.3 Appendix C - A-E Project Qualification SheetsAllows each proposed A-E firm up to three one-page project sheets. Clarifies treatment of individual Designer-of-Record JV members and A-E subconsultants.Appendix C, Section 4.4.3, states that each proposed A-E firm may submit a maximum of three (3) one-page project qualification sheets, one project per page, with no minimum. Please clarify the following:

a) If the Designer of Record is a joint venture, may each JV member submit up to three (3) project qualification sheets?

b) May each A-E subconsultant submit up to three (3) project qualification sheets? a) Yes, each JV member may submit up to three (3) project qualification sheets. However, each single JV member firm is limited to three (3) project qualification sheets only and may not submit more.

b) Yes, each A-E subconsultant may submit up to three (3) project qualification sheets.

Q8Final AOI13-14§4.4.2 Appendix B; §4.4.3 Appendix CProject sheets require identification of actual performing organizations, scope, role, and relevance. The response allows a related multi-project program to be described as a project reference.May a project qualification sheet describe a program consisting of multiple related projects supporting a single mission, such as a beddown program similar to the Nellis Future Campus program?Yes.
Q9Final AOI13-14§4.4.2 Appendix B; §4.4.3 Appendix CBoth construction and A-E project qualification sheets are limited to one page per project.May up to two (2) pages be submitted per project qualification sheet?No, please limit project qualifications to a single page.
Q10Final AOI14§4.4.5 A-E Professional QualificationsRequires Nevada-licensed civil and electrical PEs and confirmation of qualified firms without Phase 1 resumes. Government response defers names and credential details to Phase 2.Section 4.4.5 requires Nevada-licensed civil and electrical professional engineers but directs respondents not to submit resumes. Please confirm whether identifying the A-E firm and confirming the availability of Nevada-licensed civil and electrical PEs is sufficient for Phase 1, or whether names, Nevada license numbers, or other credential information should be provided.Confirmed; identifying the A-E firm and confirming the aviailability of Nevada-licensed civil and electrical professional engineers is sufficient for Phase 1. No names, license numbers or other credentials are required until Phase 2 Interview requests.
Q11Final AOI13§4.4.2 Appendix B - Construction Project Qualification SheetsAdditional airfield pavement qualification sheets apply to the identified actual military airfield pavement construction vendor or trade partner; Government response clarifies when this does not apply.Under item 4.4.2 Appendix B - Construction Project Qualification Sheets, the instructions state we can submit up to three (3) completed airfield pavement construction project sheets if we are providing an Airfield Pavement Trade Partner. If we are not providing an Airfield Pavement Trade Partner and are not proposing to provide design and construction of the airfield, please confirm that we are not required to provide three airfield pavement construction projects.If you are not proposing to provide design and construction of the airfield, you are not required to provide 3 airfield pavement construction projects.
Q12
Q13
Q14
Q15
Q16
Q17
Q18
Q19
Q20
Q21
Q22
Q23
Q24
Q25
Q26
Q27
Q28
Q29
Q30
Q31
Q32
Q33
Q34
Q35
Q36
Q37
Q38
Q39
Q40
Q41
Q42
Q43
Q44
Q45
Q46
Q47
Q48
Q49
Q50
Q51
Q52
Q53
Q54
Q55
Q56
Q57
Q58
Q59
Q60
Q61
Q62
Q63
Q64
Q65
Q66
Q67
Q68
Q69
Q70
Q71
Q72
Q73
Q74
Q75
Q76
Q77
Q78
Q79
Q80
Q81
Q82
Q83
Q84
Q85
Q86
Q87
Q88
Q89
Agency Ops Draft RFP HQ0858-21-R-0010MDA Government Comment Matrix Compilation
Approved for Public Release

22-MDA-11261 (8 Sep 22)

&"Times New Roman,Regular"&10 &"-,Regular"&11

File details come from the government source that posted it. Updated .