This document is a Questions and Answers (Q&A) addendum for Solicitation FA860125Q0153, issued by the Air Force Life Cycle Management Center (AFLCMC) at Wright-Patterson Air Force Base for a Building 558 Room 216 SIPR Door Replacement. The Q&A addresses technical specifications for a specialized STC 55 door, with specific dimensional requirements of 85 1/2" x 37 5/8" x 4 1/2". Vendors were informed about potential challenges including extended lead times (potentially over 12 weeks) due to high demand for secure facility doors, and technical considerations such as door panel thickness and egress width requirements. The document indicates that quotes may be submitted with longer lead times, and provides guidance on door panel sizing to ensure compliance with ASTM standards and building codes. The Q&A was issued on 14 August 2025 and signed by the Contracting Officer from AFLCMC/PZIBA.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

AIR FORCE LIFE CYCLE MANAGEMENT CENTER (AFLCMC)

WRIGHT-PATTERSON AIR FORCE BASE OHIO

14 August 2025

FROM: AFLCMC/PZIBA

2275 D Street Area B, Building 16, Room 128

Wright-Patterson AFB, OH 45433

SUBJECT: Response to Inquiries regarding Solicitation FA860125Q0153, Building 558 Room

216 SIPR Door Replacement

QUESTIONS & ANSWERS

QUESTION: Can the government please define the existing door panel size? Existing rough opening size, if known? Existing partition thickness?

ANSWER: Standard STC 55 dimensions, 85 1/2” x 37 5/8” x 4 1/2”

QUESTION: Due to demand from SCIF and secure room facilities, the demand for any type of customized STC 50 or higher door is very high and will be especially high at the end of the government’s fiscal year. Lead times are likely to be in excess of 12 weeks and that does not include any survey, shipping, or installation work.

ANSWER: Quotes may still be submitted with longer lead times

QUESTION: The government is requesting an STC 55 door for this installation. A true STC 55 door is going to have a panel thickness of 3”. Any vendor offering a thinner panel is not likely testing to the ASTM standard. Because of the increased panel thickness, a standard 3’ wide x 7’ high door panel will not be code compliant for egress (the finish opening, when the door is help open at 90 degrees, will be less than 32” wide measured from the face of the door to the opposite sound seal / stop) . The door panel will need to be 38” wide or wider. The extra width will often drive the requirement to reframe a standard framed partition rough opening or enlarge a masonry rough opening, which can add significantly to installation cost. This is why it’s important to understand the existing rough opening or door panel size (we can estimate the rough opening from the door panel size).

ANSWER: See measured dimensions to first answer.

DEPARTMENT OF THE AIR FORCE

AIR FORCE LIFE CYCLE MANAGEMENT CENTER (AFLCMC)

WRIGHT-PATTERSON AIR FORCE BASE OHIO

Tracy L. Ferrise

Contracting Officer

AFLCMC/PZIBA

2025-08-14T14:24:57-0400
FERRISE.TRACY.LYNN.1502030490