Final Drawings.pdf

PDF 11 MB Posted

Attached to
Project ZHTV980636 Demolish Facility 30089 Federal contract opportunity
Solicitation number
FA8601-11-R-0100
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Project ZHTV980636 Demolish Facility 30089, newest first.
File Type Posted
Wage Decision 19 Aug 2011.pdf PDF
Amendment 1 - 11-R-0100-0001.pdf PDF
RFI 002.pdf PDF
RFI 001.pdf PDF
Sign in Sheet.pdf PDF
Wage Decision 22 July 2011.pdf PDF
SW Pollution Prevention Plan.pdf PDF
Asbestos Inspection Report.pdf PDF
Final Drawings - Addendum 1.pdf PDF
Addendum 2.pdf PDF
Final Specifications.pdf PDF
Addendum 2 Specifications.pdf PDF
Soil Testing.pdf PDF
Addendum 1.pdf PDF
Hazardous Materials Report.pdf PDF
Solicitation.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

LOCATION MAP

SCALE: N.T.S.

Cincinnati, Ohio 45202

Fax (513) 721-0600

Architect:

300 West Fourth Street

Fax (937) 435-6549

Civil Engineer:

ISSUE DATE

SHEET INDEXBUILDING 30089

DECONSTRUCTION PROJECT

SFA Architects

Ph. (513) 721-0600

Tes Tech, Inc.

8534 Yankee Street

Dayton, Ohio 45458

Ph. (937) 435-3200

EnvironmentalEngineer:

Fax (937) 435-6549

Tes Tech, Inc.

8534 Yankee Street

Dayton, Ohio 45458

Ph. (937) 435-3200

BLDG 30089

R O

U T

E

S B

R O

A D

S T

R E

E T

WRIGHT AVENUE

RITCHIE ROAD

E D

W A

R D

S S

T R

E E

T

BUCKNER R

OAD

SKEEL A

VENUE

SUNDORPH DRIVE

VAN PATTON DRIVE

HARNESS ROAD

ALLBROOK DRIVE

W. DAYTON DRIVE

GREENE STREET

CLOVER STREET

SPRUCE DRIVE

MAIN STREET

LEGION LANE

CYPRESS DRIVE

MIDDLE STREET

S W

E S

T S

T R

E E

T

S F

IR

S

T S

T R

E E

T

AREA PLAN

BUILDING AREA: 149,895 GSF

MEZZANINE 1 AREA: 14,867 GSF

MEZZANINE 2 AREA: 10,300 GSF

MEZZANINE 1

MEZZANINE 2

PROJECT INFO, LOCATION MAP, KEY PLAN

A-1.0

SCALE: N.T.S.

VICINITY MAP

N

AREA C

REFERENCE NOTES

VICINITY/ LOCATION/ DWG INDEX/ REF NOTES

A-2.0

A-4.0

A-4.1

A-5.0

SEQUENCE OF CONSTRUCTION NOTES

T-1.0

R

E -S

U B

M

IT

T A

L

/2

/1

T-1.0

A-3.0

A-5.1

C-1.0

C-1.1

C-1.2

EV-1.0

L-1.0

P-1.0

P-1.1

P-1.2

M-1.0

M-1.1

M-1.2

E-1.0

E-1.2

E-2.0

E-2.1

ABBREVIATIONS AND SYMBOLS

TRUCK ROUTING PLAN

EXISTING FEATURES PLAN

BUILDING DEMOLITION PLAN

FOUNDATION DEMOLITION PLAN

SITE AND DRAINAGE DEMOLITION PLAN

SITE GRADING AND DRAINAGE PLAN

ENVIRONMENTAL PLAN AND NOTES

LANDSCAPE PLAN

EXISTING PLUMBING SITE PLAN

PLUMBING SITE DEMOLITION PLAN

PLUMBING BUILDING DEMOLITION PLAN

EXISTING STEAM AND GAS SITE PLAN

STEAM AND GAS DEMOLITION SITE PLAN

MECHANICAL BUILDING DEMOLITION PLAN

E-1.1

STORM WATER POLLUTION PREVENTION PLAN PHASE 1

STORM WATER POLLUTION PREVENTION PLAN NOTES AND DETAILS

A-5.2

E-3.0

ELECTRICAL SITE GENERAL NOTES

EXISTING ELECTRICAL SITE PLAN

ELECTRICAL SITE DEMOLITION PLAN

ELECTRICAL SITE WORK PLAN

ELECTRICAL SITE DETAILS

ELECTRICAL BUILDING DEMOLITION PLAN

1. REROUTE PRIMARY AND SECONDARY ELECTRIC FEEDS.

2. MECHANICAL AND PLUMBING UTILITY REMOVAL, REROUTE, CAP, AS PER DRAWINGS.

3. PERFORM ASBESTOS ABATEMENT THROUGHOUT ENTIRE BUILDING UNLESS AGREED UPON

WITH WPAFB CONTRACTING OFFICER TO PERFORM SUCH WORK CONCURRENT WITH

OTHER DEMOLITION ACTIVITIES.

4. PERFORM SWPPP PHASE 1 ASSOCIATED WORK.

5. PERFORM BUILDING DEMOLITION/DECONSTRUCTION WORK.

6. PERFORM UTILITY, CURB, AND MISC. SITE CONSTRUCTION ACTIVITY WORK.

7. PERFORM SWPPP PHASE 2 ASSOCIATED WORK.

SITE LAYOUT PLAN

STORM WATER POLLUTION PREVENTION PLAN PHASE 2

F

IN

A L

S U

B M

IT

T

A L

/2

/1

1. CONTRACTOR TO CHECK ENTIRE SET OF CONTRACT DOCUMENTS FOR EXTENT OF WORK.

2. CONTRACTOR TO USE AS REFERENCE THE FOLLOWING PROVIDED DOCUMENTS:

A. EXISTING DOCUMENTATION SET

B. PRE-DEMOLITION ASBESTOS INSPECTION REPORT

C. HAZARDOUS MATERIALS INSPECTION REPORT

D. CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN

E. LIMITED PHASE II ENVIRONMENTAL ASSESSMENT (SUBSURFACE SOIL SAMPLING)

3. FLOOR ELEVATIONS, GRADES, DIMENSIONS AND CONDITIONS OF EXISTING CONSTRUCTION

INDICATED ON THESE DRAWINGS AND ALL REFERENCE DOCUMENTS SHALL BE FIELD

VERIFIED BY THE CONTRACTOR. REPORT CONFLICTS OR DISCREPANCIES TO THE

CONTRACTING OFFICER FOR RESOLUTION PRIOR TO STARTING WORK.

PEARSON ROAD

AR-1.0

AR-1.1

FOUNDATION REFERENCE PLAN #1

FOUNDATION DEMOLITION PLAN #2

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

DECONSTRUCTION FACILITY 30089

PROJECT NO: 980636

A-1.0

UGEUGE UNDERGROUND ELECTRIC

WATER LINE

STORM SEWER

SANITARY SEWER

EXISTING FENCEX

W

X

W

GAS REGULATOR

BUSH

SIGN

DECIDUOUS TREE

PINE TREE

BENCHMARK

POWER POLE

TELEPHONE POLE

FIRE HYDRANT

CATCH BASIN

STORM MANHOLE

SANITARY MANHOLE

LIGHT POLE

WATER MANHOLE

WATER VALVE

CURB INLET

MONITORING WELL

GAS METER

TELEPHONE RISER

ELECTRIC BOX

GAS VALVE

GAS LINE

UNDERGROUND TELEPHONE

BOLLARD POST

G

UGT

G

UGT

T

G

G

W

S

P

WATER PIV

GAS MANHOLE

SIAMESE WATER

A/C UNIT

TELEPHONE MANHOLE

UNDERGROUND CATVUGCATV

UNDERGROUND STEAM TRENCHST ST

UGSCUGSC UNDERGROUND SIGNAL CABLE

CasementCSMT

CMP

CORR

CG

CORR

CJT

CLL

CONTR

COORD

Corrugated Metal Pipe

Contract Limit Line

Contractor

Corrugated

Corridor

Coordinate

Control Joint

Cooling Tower

Corner Guard

CIR

COMM

CONN

CONF

CND

COND

CMU

CONC

CRT

CONT

CM

CONSTR

CLO

CCTV

CLR

CO

CLRM

CKT

COL

CW

CH

CO

CHAM

CHBD

CM

C to C

CHEM

CTR

CEM

CLG

CB

CST

CIPC

CIP

CSWK

CLG HT

Circle

Closed Circuit Television

Condenser or Condensate

Conc. Masonry Unit

Computer Terminal

Communication Outlet

Construction Manager

Conference

Conduit

Concrete

Continuous

Construction

Connect(ed)(ion)

Closet

Clear(ance)

Clean Out

Classroom

Circuit

Column

Cold Water

Coat Hook

Cast-In-Place Concrete

Chemical, Chemistry

Center Line

Channel

Chamfer

Chalkboard

Ceramic Tile

Change Order

Centimeter(s)

Center to Center

Celsius, Degree

Cement

Ceiling

Cast Stone

Cast Iron

Casework

Catch Basin

Center

Ceiling Height

Cast Iron Pipe

AvenueAVE

CUH

CAB

BO

BBD

BUR

CPT

CANTL

BW

BOC

BOT

BLDG

BRK

BRZ

BRKT

BFE

BRIDG

BLR

BLKG

BLK

BITUM

BVL

BTWN

BM

BLW

AVG

BRG

BM

BSMT

B&B

BAL

BJT

BPL

Both Sides

Cabinet Unit Heater

Bottom Footing Elevation

Cabinet

Building Line

Bumper Guard

Bulletin Board

Carpet(ed)

Cantilever

By Others/Owner

Built-up Roofing

Bottom

Both Ways

Building

Brick

Bronze

Bridging

Bracket

Bottom Face

Bottom of Curb

Bevel(ed)

Boiler

Board

Blocking

Block

Bituminous

Between

Below

Bedroom

Bench Mark

Bearing

Beam

Basement

Balance

Average

Back of Curb

Bed Joint

Bearing Plate

Balled & Bagged

AC or ACOUS

AP or AC PNL

ANC

APT

ANOD

AUTO

ASPH

AD

APC

ARCH

APPROX

ADJT

ADJ

ADH

ALUM

ALT

AHU

ACU

A/C

AGG

ALLOW

ASC

ADD

AWT

ACT

ACPL

ACFL

AD

ACC

ADDL

AFF

ABV

Anchor, Anchorage

Air Conditioning Unit

Architectural Precast Concrete

Apartment

Anodized

Anchor Bolt

Automatic

Asphalt

Area Drain

Architect(ural)

Approximate

Adjustable

Adjacent

Adhesive

Aluminum

Alternate

Allowance

Aggregate

Air Conditioning

Air Handling Unit

Above Finish Floor

Above Suspended Ceiling

Acoustical Wall Treatment

Acoustical Plaster

Acoustical

Access

Access Floor

Access Door

Addendum

Access Panel

Acoustical Tile

Additional

Above

Grade BeamGR BM

HDWD

HD

HDW

HDBD

GWB

GYP

GU

GRND

GR

HNDRL

Gypsum Wallboard

Hardwood

Head

Hardware

Hardboard

Handrail

Gypsum

Gutter

Ground

Grade

Double HungDH

Face of StudFOS

FD

GA

FUT

GL

GEN

GC

GAL

GALV

GB

GLU LAM

FT

FL

FUR

FBY

FURNFS

FRM

FDTN

FTG

FLUOR

FIX

FP

FHC

FH

FCO

FLR

FHWS

FHMS

FF&E

FLASH

FT

F

FE

FFL

FFE

FIN

FF

FAS

FOW

FEC

Floor Drain

General Contract(or)

Furnished By Others

Furring

Glass

Generator

Galvanized

Gallon

Future

Grab Bar

Glue Laminated

Gage or Gauge

Foot, Feet

Fluorescent

Flow Line

FurnishFull Size

Frame

Foundation

Footing

Finished Floor Line

Finished Floor Elevation

Flat Head Wood Screws

Flat Head Machine Screws

Fire Hose Cabinet

Fire Hydrant/Hose

Fixtures, Furniture & Equipment

Fire Extinguisher Cabinet

Floor

Flashing

Fixture

Fireproof

Floor Cleanout

Finish

Fahrenheit

Face of Wall

Finished Floor

Fire Extinguisher

Fasten, Fastener

Feet

EL or ELEV

ENGR

EIFS

EXT

EJT

EXP

FOM

FOC

FB

EXTRU

EF

EG

EXH

EST

ESTB

ESC

EQ

ENTR

EXIST’G

EQUIP

E

ELEC

EWC

ELAS

EW

EF

ENCL

EMER

ELEV

DWG

DWR

DS

DN

EE

EA

DUP

DF

DWL(S)

Engineer

Finish System

Exterior Insulation &

Face of Concrete

Exterior

Expansion

Face Brick

Extrusion

Expansion Joint

Face of Masonry

Existing

Exhaust

Estimate

Establish

Escalator

Equipment

Equal

Exhaust Fan

Entrance

Exhaust Grille

Electric Water Cooler

Each Face

Electrical

Elastomeric

Each Way

Enclosure

Emergency

Elevator

Elevation

East

Dowel(s)

Drawing

Drawer

Downspout

Down

Each End

Duplicate

Each

Drinking Fountain

DP

DIR

DR

DR

DIV

DIST

DISP

DO

DBL

DO

DBL ACT

D

DC

DIM

DIFF

DIA

DIAG

DTL

DSGN

DEPT

DEG

CFM

CI

DP

CYL

CY

CF

DL

DMT

DEMO

Deep

Direction, Director

Double

Doctor

Division

Distribution

Dispenser

Door

Double Acting

Door Opening

Ditto

Depth

Department

Degree

Dimension

Diffuser

Diameter

Diagonal

Detail

Design

Direct Current

Cubic Feet Per Minute

Demolish, Demolition

Cylinder

Cubic Yard

Cubic Inch

Cubic Foot

Demountable

Dead Load

Dampproofing

Masonry

Original

PTD

PERF

PVMT

PTN

OH

ORD

OA

OD

OTO

OZ

PNL

PR

PTD

Overflow Roof Drain

Paper Towel Dispenser

Perforated

Pavement

Partition

Ounce

Panel

Painted

Overhead

Overall

Out to Out

Outside Diameter

Pair

NIC

OB

NO

NTS

OFF

ORIG

OPP

OPNG

OC

OB GL

N

MULL

NORM

NOM

NRC

NAT

NA

NW

NE

MM

MTD

MTR

MLDG

MOD

MIX

MISC

MIR

MIN

MIN

MLWK

M

MBR

MED

MECH

MAX

MATL

MO

MEMB

MEZZ

MTL

Noise Reduction Coefficient

Not In Contract

Center

Obscure

Number

Obscure Glass

Not to Scale

Office

Opposite

Opening

On

Mullion

Northwest

Northeast

North

Normal

Nominal

Natural

Not Applicable

Millimeter

Minute

Minimum

Millwork

Mounted

Mortar

Molding

Mixture

Mirror

Miscellaneous

Modified, Modular

Member

Medium

Mechanical

Maximum

Material

Meter

Membrane

Mezzanine

Metal

Masonry Opening

LWT CONC

LONG

LVR

MAS

MFR

MAN

MH

MAINT

MS

MACH

LP

LL

LT

LLH

LOC

LTL

LIN

LWT

LTG

LLV

K

L

LG

LAM

LAB

KO

KD

KIT

LH

LAV

JT

JAN

KVA

KW

KPL

JB

JST

JST BR

Length

Lightweight Concrete

Long Leg Vertical

Long Leg Horizontal

Longitudinal

Louver

Manual

Manhole

Machine

Manufacturer

Maintenance

Low Point

Machine Screw

Live Load

Lintel

Linear

Lightweight

Lighting

Light

Locate, Location

Kips

Laminated

Laboratory

Knockout

Kitchen

Knocked Down

Left Hand

Lavatory

Large

Janitor

Kilowatts

Kick Plate

Junction Box

Joist

Kilovolt Amps

Joist Bearing

Joint

INSUL PNL

HWY

ILLUM

IF

ID

INVT

INT

INSUL

INFO

INC

IN

INVT EL

HR

HWH

HW

HP

HM

HC

HYD

HORIZ

H

HDR

HTG

H PT

HZ

HT

HVAC

Highway

Hot Water Heater

Illumination

Invert

Interior

Insulation

Inside Face

Information

Inches

Invert Elevation

Insulated Panel

Inside Diameter

Include(d) (ing)

Hot Water

Horsepower

Horizontal

Hollow Metal

Hollow Core

Hour

Hydrant

Air Conditioning

Heating, Ventilating, Header

High Point

Hertz

Height

Heating

High

Refrigerator REFR

W/

WI

YD

WPT

WD

W/O

WTW

W

W

WF

WT

WWF

WH

WC

WG

WDW

Welded Wire Fabric

With

Wrought Iron

Without

Wood

Working Point

Yard

Wall to Wall

Water Closet

Wide Flange

Weight

Water Heater

Wired Glass

Window

Wide, Width

West

VAR

V

VENT

VEN

WSCT

VOL

VIT

VWC

VCT

VERT

TYP

VB

VAL

UTIL

UR

UNFIN

USG

UL

T&G

TOW

TOS

TOP

TOF

TOD

TOC

TOB

TB

TR

TOPAR

TEL

TKBD

TV

TEMP

TPD

THK

THERM

TEX FIN

TEMP GL

Underwriter’s Laboratories

United States Gage

Vinyl Wall Covering

Vinyl Composition Tile

Varnish

Veneer

Ventilating

Wainscot

Vitreous

Volume

Vertical

Volt

Value

Unfinished

Urinal

Utility

Typical

Vapor Barrier

Toilet Paper Dispenser

Tongue and Groove

Top of Curb (Concrete)

Top of Deck

Top of Pier

Top of Steel

Top of Wall

Top of Beam

Towel Bar

Transom

Top of Footing

Top of Parapet

Telephone

Television

Tackboard

Thermal

Thick(ness)

Temperature

Textured Finish

Tempered GlassL

STRUCT STL

ST STL or SS

SQ FT or SF

SECT

SYS

SW

SUSP

SA

STOR

STL

STD

STAG

SIM

SHT

S

SPEC

SW

SE

STC

SQ

RM

RFG

RD

ROW

SAN

RND

RO

SCD JT

SCHED

RCP

REINF

REG

REBAR

RH

REV

RA

RET

REQD

RLF

Section

Sound Transmission

Square

Steel

Staggered

Standard

Storage

Supply Air

Suspended

Switch

System

Stainless Steel

Structural Steel

Coefficient

Specification

Sheet

Similar

South

Southeast

Southwest

Square Foot

Reinforced Concrete Pipe

Roof Drain

Roofing

Room

Right of Way

Scored Joint

Sanitary

Schedule

Round

Rough Opening

Regular

Right Hand

Revision

Return Air

Return

Required

Relief

Reinforcing Bar

Reinforcing (ed)

RE or REF

PC

QT

R

RECT

REC

RECP

RR

QTR

QT

PI

PSI

PSF

PCF

PVC

QUAL

PL

PROJ

PRELIM

PT

PWD

PL

PLAM

PLUMB

Point of Curve

Pounds per Square Foot

Pounds per Cubic Foot

Point of Intersection

Pounds per Square Inch

Quarry Tile

Reference

Rectangular

Recessed

Receptacle

Railroad

Radius

Quarter

Quart

Projection

Quality

Preliminary

Property Line

Polyvinyl Chloride

Point, Point of Tangent, Pressure Treated Lumber

Plywood

Plumbing

Plate

Plastic Laminate

ABBREVIATIONS ARCHITECTURAL SYMBOLS

SECTION NUMBER

DRAWING NUMBER

WALL / BUILDING SECTION INDICATOR

CAX

LAB

ROOM NAME

ROOM NUMBER

ROOM NAME INDICATOR

A

DETAIL NUMBER

DRAWING NUMBER

C5

A700

ELEVATION INDICATOR

DETAIL NUMBER

DRAWING NUMBER

ENLARGED PLAN INDICATOR

EQUIPMENT TAG

A COLUMN LINE INDICATOR

N

NORTH ARROW

ELEVATION INDICATOR

ELECTRIC WATER COOLER

BREAK LINES

NEW INSULATION- BATT

MATERIALS LEGEND

NEW GWB

EARTH

INSULATION BOARD

NEW CONCRETE

GRAVEL

PLYWOOD

PARTITION TYPE INDICATOR - SEE A001

DOOR NUMBER - SEE A620-622

CEILING HEIGHT/TYPE - SEE A300 SERIES

FURNITURE TAG - SPEC SECTION ?????

ELEC. PANEL

WINDOW TYPE - EXTERIOR

WINDOW TYPE - INTERIOR

EXISTING BRICK

EXISTING CMU

FIRE EXTINGUISHER CABINET

NEW CMU

NEW BRICK

EXISTING CONCRETE

EXISTING STUD WALL

NEW STUD WALL

FIRE EXTINGUISHER ON WALL BRACKET

E.P.

F.E.

F.E.

L-2

NEW LINTEL SCHEDULE

LINTEL NUMBER

DRAWING NUMBER

UNO Unless Otherwise Noted

CFMF Cold Formed Metal Framing

(E) Existing

CT

AB

BC

BR

BD

BS

BF

BL

BG

CI

CL

CT

C

C

MEP Mechanical, Electric, & Plumbing

F-R Fire Retardant Treated

A

A623

W4

FR Fire Rated

ENGINEERING SYMBOLS

ABBREVIATIONS AND SYMBOLS

STMSTM

SS SS

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

1/32" = 1’-0"A-1

1 FIRST FLOOR PLAN

MEZZANINE 1

MEZZANINE 2

GENERAL NOTES

CODED NOTES1

KEY PLAN

1/32" = 1’-0"

MEZZANINE 1 PLAN

1/32" = 1’-0"

MEZZANINE 2 PLAN

N O

R T

H

NORTH

NORTH

ROOF PLAN

N.T.S.

NORTH

A-4.0

50’-0"

BUILDING DEMOLITION PLAN

1. REMOVE BUILDING CONSTRUCTION COMPLETELY INCLUDING ROOF, WALLS, SLAB, FOUNDATIONS, DOORS, WINDOWS, CEILING SYSTEMS, ETC. REFER TO FOUNDATION PLAN FOR MORE INFORMATION.

2. DISMANTLE EXISTING RAISED FLOORING AND ALL COMPONENTS AND DELIVER TO AREA DESIGNATED BY

WPAFB CONTRACTING OFFICER.

3. REMOVE FIRE DOOR. ASSUME DOOR CONTAINS ASBESTOS MATERIALS INSIDE.

4. INDICATES UNDERGROUND ELECTRIC UTILITY. REFER TO SHEET E-1 FOR MORE INFORMATION.

5. CONTRACTOR TO INVESTIGATE THE EXISTING CONDITION OF THE ROOF IN REGARDS TO WORKER SAFETY AND

NOTIFY CONTRACTING OFFICER OF UNSAFE WORKER CONDITIONS.

6. PRIOR TO ROOF DEMOLITION, CONTRACTOR TO REMOVE ALL MECHANICAL EQUIPMENT AND

DISCONNECT/REMOVE ASSOCIATED PIPING, CONTROLS, AND ELECTRICAL CONNECTIONS. WPAFB HAS

ELECTED NOT TO SALVAGE THIS EQUIPMENT.

1. CONTRACTOR TO VERIFY DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK.

2. EACH TRADE SHALL COORDINATE WITH THE CONTRACTOR AND VERIFY SIZE AND LOCATION OF ALL RECESSES, CHASES, AND OPENINGS REQUIRED FOR THE REMOVAL OF MECHANICAL, ELECTRICAL, AND OTHER

EQUIPMENT.

3. ALL ITEMS NOTED FOR REMOVAL SHALL BE REMOVED COMPLETELY, INCLUDING ENTIRE SYSTEM OF SUSPENSION, ANCHORS, CLIPS, AND ADHESIVES, ETC RELATED TO THAT ITEM. REMOVAL SHALL BE PERFORMED CAREFULLY TO MINIMIZE DAMAGE, PARTICULARLY ITEMS TO BE SALVAGED FOR REUSE OR

RETURNED TO THE OWNER.

4. CONTRACTOR TO CONTROL FUGITIVE DUST WHEN USING HEAVY EQUIPMENT TO DEMOLISH STRUCTURES.

5. REFER TO ELECTRICAL BUILDING DEMOLITION PLAN FOR MORE INFORMATION RELATED TO DEMOLITION OF THE

EXISTING CEILING SYSTEMS.

6. CONTRACTOR TO SALVAGE THE FOLLOWING ITEMS AND DELIVER TO ON-BASE LOCATION PER COORDINATION

WITH WPAFB CONTRACTING OFFICER.

- EXTERIOR ROLL-UP DOORS AND ASSOCIATED HARDWARE

- EXTERIOR GUTTERS AND DOWNSPOUTS

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

DECONSTRUCTION FACILITY 30089

PROJECT NO: 980636

RAMP DOWNUP

UP

UP

UP

R A

M P

U P

UP

UP

UP

UP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

UP

UP

DOWN

UP

UP

DN

UP

STEAM

PIT

VENT

SPRINKLER

DRAW OFF

SPRINKLER

DRAW OFF SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

UP

DF

C W

* MISC. SYSTEMS

FURNITURE* * MISC. SYSTEMS

FURNITURE*

DF

WH

UP

ELEV

MH

PHONE RACKS

VENT VENT

x x x x x x x x x x x x x x x x x x x

DF

PIT

BACKFLOW

VALVES

P H

O N

E R

O O

M

WH

PIT

*FURNITURE

STORAGE*

PT SD SD PT AIR

PT SD SD PT AIR

S P

R

WH

DF

DF

WH

S P

R

IN

K L

E R

R O

O M

F P

P A

N E

L

FP

PANEL

PT

SD

PT

DF

FND

P H

O N

E R

O O

M

UP

AIR HANDLER 4

VENT

x

VENT

VENT VENT

PHONE

ROOM

UP

WH

WH

DF

DF

WH

DN

DN

STORAGE BALCONY

PT

PT

* MISC. SYSTEMS

FURNITURE*

* MISC. SYSTEMS

FURNITURE*

* MISC. SYSTEMS

FURNITURE*

* MISC. OFFICE

FURNITURE*

DN

DN

DN

D N

D N

D F

GENERAL NOTES

CODED NOTES1

NORTH

A-4.1

1/32" = 1’-0"A-4.1

1 FOUNDATION DEMOLITION PLAN

N.T.S.A-4.1

A FDN TYPE ’A’

N.T.S.A-4.1

B FDN TYPE ’B’

N.T.S.A-4.1

C FDN TYPE ’C’

N.T.S.A-4.1

D FDN TYPE ’D’

N.T.S.A-4.1

E FDN TYPE ’E’

N.T.S.N.T.S.N.T.S.A-4.1N.T.S.A-4.1N.T.S.A-4.1

N.T.S.A-4.1

I-I FDN TYPE ’I-I’

C-C FDN TYPE ’C-C’ G-G FDN TYPE ’G-G’ H-H FDN TYPE ’H-H’

TYP. INTERIOR

COLUMN FOOTING

TYP. EXTERIOR

WALL SLAB

619’-4 1/2 "

/2

8’-0"x8’-0 PIT

W/ 8" THK WALLS

A

A A A

A

A

ACB CB CB CB CB CB CB CB CB CB BB A

A

G

-G

H-H

H-H

H-H

H-H

C-CI-I

A

CB

D

E

D

E

D

E

D

E

D

CB CB CB CB CB CB CB BB

H-H

I-I BB

FOUNDATION DEMOLITION PLAN

1. REMOVE ALL FOUNDATION AND FOOTING CONSTRUCTION COMPLETELY.

2. CONTRACTOR TO REMOVE EXISTING UNDERGROUND PIT AND ALL ASSOCIATED UTILITIES.

1. CONTRACTOR TO VERIFY DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. THE DRAWINGS ARE

ILLUSTRATIVE AND MAY NOT REFLECT EXACT CONDITIONS OR DIMENSIONS.

2. THE DESIGN AND DRAWINGS ARE BASED ON THE USE OF SPECIFIC REFERENCE DRAWINGS AS PROVIDED BY WPAFB PERSONNEL. THESE DRAWINGS HAVE BEEN PROVIDED FOR THE CONTRACTORS REFERENCE AS:

* AR-1.0 FOUNDATION REFERENCE PLAN #1

* AR-1.1 FOUNDATION REFERENCE PLAN #2

THE DRAWINGS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THEIR

ACCURACY OR COMPLETENESS TO AS-BUILT CONDITIONS.

3. ALL ITEMS NOTED FOR REMOVAL SHALL BE REMOVED COMPLETELY. REMOVAL SHALL BE PERFORMED CAREFULLY TO MINIMIZE DAMAGE TO ADJACENT ASSEMBLIES OR UTILITIES SCHEDULED TO REMAIN.

4. THE CONTRACTOR IS RESPONSIBLE FOR ACHIEVING THE MINIMUM WASTE DIVERSION REQUIREMENTS AS INDICATED IN THE PROJECT SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL MATERIAL FROM THE SITE, THE BASE IF DEEMED APPROPRIATE, ALL HAULING OF MATERIAL, AND ANY TECHNIQUES UTILIZED FOR THE CRUSHING OF MATERIAL. THESE ITEMS SHALL BE COORDINATED WITH

WPAFB CONTRACTING OFFICER.

5. ANY EXISTING CONDITION DISCOVERED DURING THE DEMOLITION PROCESS WHICH, BY GENERALLY ACCEPTED CONSTRUCTION PRACTICES, SHOULD BE REMEDIED, SHOULD BE BROUGHT TO THE ATTENTION OF THE

WPAFB CONTRACTING OFFICER IMMEDIATELY AND IN WRITING.

6. PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL PERFORM A DETAILED WALK-THRU FIELD INSPECTION TO REVIEW THE EXISTING STRUCTURES AND PREMISES, TO DETERMINE ALL EXISTING CONDITIONS AND SHALL MAKE ALL NECESSARY ALLOWANCES FOR ALL REQUIRED FOUNDATION AND

FOOTING DEMOLITION WORK.

7. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED FOR DEMOLITION AND DISPOSAL.

8. CONTRACTOR IS RESPONSIBLE FOR REPAIRING THE DAMAGE DONE TO ANY EXISTING ITEM DURING DEMOLITION. REPAIRS SHALL BE EQUAL TO, OR BETTER THAN, EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE TO DOCUMENT ALL EXISTING DAMAGE AND NOTIFY THE BASE CONTRACTING OFFICER PRIOR

TO CONSTRUCTION START.

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

NORTH

1/32" = 1’-0"P-1

O

R T

H

CODED NOTES1

KEY PLAN

1/32" = 1’-0"

MEZZANINE 1 PLAN

1/32" = 1’-0"

MEZZANINE 2 PLAN

PLUMBING REMOVAL NOTES

1. REMOVE OR DEMOLISH ALL PLUMBING SYSTEMS WITHIN BUILDING 89, UNLESS OTHERWISE NOTED. PLUMBING SYSTEMS SHALL INCLUDE ALL PIPING (DOMESTIC WATER, DRAIN, WASTE, VENT, STORM & CONTROL AIR), FIRE SUPPRESSION SYSTEMS, AND PLUMBING FIXTURES.

2. FOR PURPOSES OF CLARITY, NOT ALL PIPING IS SHOWN. CONTRACTOR SHALL REMOVE ALL PIPING (UNLESS OTHERWISE INDICATED) INCLUDING VALVES, HANGERS, SUPPORT SYSTEMS, CONTROLS, AND MISC.

ACCESSORIES WHETHER SHOWN OR NOT.

TYP.

5 5

P-1.2

PLUMBING BUILDING DEMOLITION PLANS

1. REMOVE WATER CLOSET AND ALL WASTE, VENT AND CW PIPING COMPLETE.

2. REMOVE URINAL AND ALL WASTE, VENT AND CW PIPING COMPLETE.

3. REMOVE LAVATORY AND ANY ASSOCIATED CASEWORK AND ALL WASTE, VENT, CW AND HW PIPING

COMPLETE.

4. REMOVE SERVICE SINK AND ALL WASTE, VENT, CW AND HW PIPING COMPLETE.

5. REMOVE WATER COOLER AND ALL WASTE, VENT, AND CW PIPING COMPLETE.

6. REMOVE ALL FIRE SUPPRESION PIPING AND CONTROLS COMPLETE.

7. REMOVE WATER HEATER AND ALL ASSOCIATED PIPING.

8. INDICATES LOCATION OF FORMER SILVER-RECOVERY OPERATION. DURING DEMOLITION OF SANITARY DRAINS, SHOULD THE CONTRACTOR ENCOUNTER A BLACK GREASE MATERIAL, STOP WORK IMMEDIATELY AND NOTIFY THE CONTRACTING OFFICER. TURN IN ALL RECLAIMED SILVER TO 88 ABW/CEANPIAW SECTION 3.10 OF WPAFB SPECIFICATION SECTION 01 02 20. FOR ADDITIONAL INFORMATION PLEASE CONTACT THE 88

ABW/CEANP HAZARDOUS WASTE PM GARY SELBY AT 937-257-3349 OR BY EMAIL AT

GARY.SELBY@WPAFB.AF.MIL.

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

DECONSTRUCTION FACILITY 30089

PROJECT NO: 980636

RAMP DOWNUP

UP

UP

UP

R A

M P

U P

UP

UP

UP

UP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

UP

UP

DOWN

UP

UP

DN

UP

STEAM

PIT

VENT

SPRINKLER

DRAW OFF

SPRINKLER

DRAW OFF SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

UP

DF

C W

DF

WH

UP

ELEV

VENT VENT

x x x x x x x x x x x x x x x x x x x

DF

BACKFLOW

VALVES

WH

PIT

PT SD SD PT AIR

PT SD SD PT AIR

S P

R

WH

DF

DF

WH

S P

R

IN

K L

E R

R O

O M

F P

P A

N E

L

FP

PANEL

PT

SD

PT

DF

FND

UP

VENT

x

VENT

VENT VENT

UP

WH

WH

DF

DF

WH

DN

DN

STORAGE BALCONY

PT

PT

DN

DN

DN

D N

D N

O

R T

H

CODED NOTES1

KEY PLAN

1/32" = 1’-0"

MEZZANINE 1 PLAN

1/32" = 1’-0"

MEZZANINE 2 PLAN

MECHANICAL REMOVAL NOTES

TYP.

1. REMOVE OR DEMOLISH ALL MECHANICAL SYSTEMS WITHIN BUILDING 89, UNLESS OTHERWISE NOTED.

MECHANICAL SYSTEMS SHALL INCLUDE HVAC EQUIPMENT (CHILLERS, PUMPS, CONDENSING UNITS, AIR HANDLING UNITS, DUCTWORK, AIR DEVICES, WALL LOUVERS, CONTROL DAMPERS, ROOF VENTS, EXHAUST

FANS, HVAC CONTROL SYSTEMS, AND ANY ASSOCIATED PIPING).

2. FOR PURPOSES OF CLARITY, NOT ALL DUCTWORK AND PIPING ARE SHOWN. CONTRACTOR SHALL REMOVE ALL DUCTWORK AND PIPING (UNLESS OTHERWISE INDICATED) INCLUDING VALVES, HANGERS, SUPPORT

SYSTEMS, CONTROLS, AND MISC. ACCESSORIES WHETHER SHOWN OR NOT.

3. COORDINATE SHUT-DOWN OF ALL UTILITIES SERVING THE BUILDING WITH WPAFB CONTRACTING OFFICER.

4. LOCATIONS OF EQUIPMENT ARE SCHEMATIC. CONTRACTOR TO FIELD VERIFY EQUIPMENT LOCATIONS AND

EXTENT OF PIPING AND DUCTWORK.

5. PROVIDE REFRIGERANT RECOVERY FROM EXISTING REFRIGERATION SYSTEMS IN ACCORDANCE WITH

SPECIFICATION SECTION 02 09 10 PRIOR TO REMOVAL OF ANY HVAC EQUIPMENT.

6. CONTRACTOR TO NOTIFY WPAFB CONTRACTING OFFICER IMMEDIATELY UPON DISCOVERY OF PIPING WITH ASBESTOS INSULATION. REFER TO PRE-DEMOLITION ASBESTOS REPORT FOR MORE INFORMATION.

1. REMOVE AIR HANDLING UNIT AND ALL ASSOCIATED DUCTWORK AND AIR DEVICES, LOUVERS, DAMPERS, SOUND ATTENUATORS, FILTER BANKS, COILS, DRAIN PIPING, HVAC CONTROLS, SUPPORTS, AND

ACCESSORIES COMPLETE.

2. REMOVE REFERIGERATION MACHINE AND ALL ASSOCIATED PIPING AND CONTROLS. TRANE MODEL

CGAB0304AEIOBF13.

3. REMOVE HEAT PUMP AND ALL ASSOCIATED PIPING AND CONTROLS. CARRIER MODEL 50YQI30310.

4. REMOVE HEAT PUMP AND ALL ASSOCIATED PIPING AND CONTROLS. TRANE MODEL WCL03OF100BA

5. REMOVE HEAT PUMP AND ALL ASSOCIATED PIPING AND CONTROLS. TRANE MODEL WCH240B300BA.

6. REMOVE AIR DRYER AND ALL ASSOCIATED PIPING AND CONTROLS. KELAIR MODEL IN-5.

7. REMOVE LIEBERT UNIT AND ALL ASSOCIATED PIPING AND CONTROLS.

8. REMOVE CLIMATE CHANGER AND ALL ASSOCIATED PIPING AND CONTROLS. TRANE MODEL CC8812BBLCO.

9. REMOVE SMOKE EETER AND ALL ASSOCIATED CONTROLS.

10. REMOVE ICE MAKER AND ALL ASSOCIATED PIPING.

11. CONTRACTOR TO INVENTORY ALL EQUIPMENT LOCATED ABOVE VIA PULL DOWN STAIR AND COORDINATE WITH WPAFB CONTRACTING OFFICER FOR SALVAGEABLE EQUIPMENT. REMOVE ALL EQUIPMENT, PIPING, AND CONTROLS AS DEEMED NON-SALVAGEABLE BY CONTRACTING OFFICER INCLUDING EXISTING AIR BLOWER AND

ALL ASSOCIATED PIPING AND CONTROLS. AMERICAN STANDARD MODEL 182ER.

12. CONTRACTOR TO INVENTORY ALL EQUIPMENT SERVING MEZZANINE AREA 2 AND COORDINATE WITH WPAFB CONTRACTING OFFICER FOR SALVAGEABLE EQUIPMENT. REMOVE ALL EQUIPMENT, PIPING, AND CONTROLS

AS DEEMED NON-SALVAGEABLE BY CONTRACTING OFFICER.

13. REMOVE EXISTING FANS AND ASSOCIATED PIPING AND CONTROLS LOCATED ABOVE.

14. CONTRACTOR TO INVENTORY ALL EQUIPMENT LOCATED IN HVAC ROOM AND COORDINATE WITH WPAFB CONTRACTING OFFICER FOR SALVAGEABLE EQUIPMENT. REMOVE ALL EQUIPMENT, PIPING, AND CONTROLS

AS DEEMED NON-SALVAGEABLE BY CONTRACTING OFFICER.

15. PRIOR TO START OF DEMOLITION, THE GOVERNMENT, 88ABW/CEOFA @ 257-4514 OR 904-2431, SHALL BE CONTACTED AND AFFORDED THE OPPORTUNITY TO REMOVE ANY CONTROLS IT DEEMS SALVAGEABLE;

STAEFA CONTROL DEVICES.

151515

M-1.2

MECHANICAL BUILDING DEMOLITION PLANSCOVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

DECONSTRUCTION FACILITY 30089

PROJECT NO: 980636

RAMP DOWNUP

UP

UP

UP

R A

M P

U P

UP

UP

UP

UP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

UP

UP

DOWN

UP

UP

DN

UP

STEAM

PIT

VENT

SPRINKLER

DRAW OFF

SPRINKLER

DRAW OFF SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

UP

DF

C W

DF

WH

UP

ELEV

PHONE RACKS

VENT VENT

x x x x x x x x x x x x x x x x x x x

DF

BACKFLOW

VALVES

P H

O N

E R

O O

M

WH

PIT

PT SD SD PT AIR

PT SD SD PT AIR

S P

R

WH

DF

DF

WH

S P

R

IN

K L

E R

R O

O M

F P

P A

N E

L

FP

PANEL

PT

SD

PT

DF

FND

P H

O N

E R

O O

M

UP

AIR HANDLER 4

VENT

x

FAN

FAN

FAN

FAN FAN

FAN

FAN

FAN FAN

FAN

FAN

FAN

FAN

F A

N

FAN

FAN

FAN FAN

FAN

FAN

FAN

FAN

FAN

FAN

FAN

VENT

VENT VENT

PHONE

ROOM

UP

WH

WH

DF

DF

WH

DN

DN

STORAGE BALCONY

PT

PT

DN

DN

DN

D N

D N

CODED NOTES1

KEY PLAN

1/32" = 1’-0"

MEZZANINE 1 PLAN

1/32" = 1’-0"

MEZZANINE 2 PLAN

ELECTRICAL REMOVAL NOTES

HI

LEGEND

2 x 4 RECESSED FLUORESCENT FIXTURE

1x 4 RECESSED FLUORESCENT FIXTURE

2 x 2 RECESSED FLUORESCENT FIXTURE

WALL MOUNTED FLUORESCENT FIXTURE

RECESSED INCANDESCENT FIXTURE

RECESSED INCANDESCENT FIXTURE

RECESSED INCANDESCENT FIXTURE (CAN LIGHT)

HANGING HIGH BAY LIGHT FIXTURE

HANGING FLUORESCENT STRIP FIXTURE

2 x 4 HANGING FLUORESCENT STRIP FIXTURE

1 x 4 HANGING FLUORESCENT STRIP FIXTURE

1 x 2 HANGING FLUORESCENT STRIP FIXTURE

2 x 8 HANGING FLUORESCENT STRIP FIXTURE

1. REMOVE OR DEMOLISH ALL ELECTRICAL SYSTEMS WITHIN BUILDING 89, UNLESS OTHERWISE NOTED.

ELECTRICAL SYSTEMS SHALL INCLUDE CABLING, PANELBOARD, MOTORS AND CONTROL CENTERS, SWITCHBOARD, DISCONNECTS, RECEPTACLES, OUTLETS, LIGHTING, EQUIPMENT, SWITCHES, ETC.

2. REMOVE OR DEMOLISH ALL DATA CONVEYANCE SYSTEMS WITHIN BUILDING 89, UNLESS OTHERWISE NOTED.

DATA CONVEYANCE SYSTEMS SHALL INCLUDE CABLING, RECEPTACLES, CONDUIT, TELEPHONE DISTRIBUTION

SYSTEMS, CABLETRAY, BRACKETS AND SUSPENSION SYSTEMS, ETC.

3. FOR PURPOSES OF CLARITY, NOT ALL ELECTRICAL SYSTEM OR DATA CONVEYANCE SYSTEMS ARE SHOWN.

CONTRACTOR SHALL REMOVE ALL ITEMS COMPLETE.

4. COORDINATE SHUT-DOWN OF ALL UTILITIES SERVING THE BUILDING WITH WPAFB CONTRACTING OFFICER.

5. LOCATIONS OF EQUIPMENT ARE SCHEMATIC. CONTRACTOR TO FIELD VERIFY EQUIPMENT LOCATIONS.

6. FOR PURPOSES OF CLARITY, NOT ALL LIGHT FIXTURES ARE SHOWN. CONTRACTOR TO REMOVE ALL LIGHT

FIXTURES COMPLETE, WHETHER SHOWN OR NOT.

7. CONTRACTOR TO NOTIFY WPAFB CONTRACTING OFFICER IMMEDIATELY UPON DISCOVERY OF OIL FILLED ELECTRICAL EQUIPMENT WITH THE EQUIPMENT OIL VERIFIED TO BE NON-PCB CONTAINING. REFER TO

SPECIFICATION SECTION 02 84 33 FOR MORE INFORMATION.

N O

R T

H

NORTH

NORTH

SYMBOL DESCRIPTION REMARKS

REMOVE THE LUMINAIRE, CONDUCTORS, CONNECTIONS

AND RACEWAY. REMOVE ALL BRACKETS AND

ATTACHING HARDWARE. RECYCLE THE LAMPS AND

BALLASTS CONSISTENT WITH SPECIFICATION

SECTIONS 02 08 33 AND 02 08 34.

REMOVE THE LUMINAIRE, CONDUCTORS, CONNECTIONS

AND RACEWAY. REMOVE ALL BRACKETS AND

ATTACHING HARDWARE. RECYCLE THE LAMPS.

1. INDICATES ACCESS PIT FOR MAIN POWER FEED. CONTRACTOR TO COORDINATE WITH WPAFB CONTRACTING

OFFICER FOR UTILITY SHUT-DOWN.

2. INDICATES ACCESS PIT TO MAIN POWER FEED SWITCH. CONTRACTOR TO COORDINATE WITH WPAFB

CONTRACTING OFFICER FOR UTILITY SHUT-DOWN.

3. REMOVE HIGH VOLTAGE TRANSFORMER, CONNECTIONS, AND CABLES BACK TO SOURCE. PAUWELS 3-PH, 60HZ, 300 KVA, HV 12470, LV208.

4. REMOVE SWITCHGEAR, CONNECTIONS, AND CABLES. AMERICAN MIDWEST TYPE F-FDP, ENCLOSURE TYPE 1, VOLTAGE 208Y/120, SYSTEM 3-PHASE 4W, AMPS SUPPLY 1,200, RMS SYM AMPS 50,000, (2) SECTIONS.

5. REMOVE PANELBOARD, CONNECTIONS, AND CABLES. FEDERAL PACIFIC 400A, 60HZ, 3-PH.

6. REMOVE ALL CONTROL SYSTEM AND PANELS ASSOCIATED WITH AIR HANDLER 4. REMOVE CONNECTIONS AND CABLES. REMOVAL INCLUDES BUT NOT LIMITED TO HONEYWELL CONTROL SYSTEM, SPECTRUM

CONTROL PANELS, EMS MODEL G3U-40-1 PANEL.

7. REMOVE TRANSFORMER, CONNECTIONS, AND CABLES. SQUARE D DRY TYPE, 750KVA, HV12000, LV480Y/277.

8. REMOVE MOTOR CONTROL CENTER, CONNECTIONS, AND CABLES. SQUARE D MODEL #6.

9. REMOVE TRANSFORMER, CONNECTIONS, AND CABLES. SQUARE D 3-PH, 225KVA, HV480, LV270.

10. REMOVE TRANSFORMER, CONNECTIONS, AND CABLES. SORGEL 3-PH, 150KVA, HV480, LV240.

11. REMOVE TRANSFORMER, CONNECTIONS, AND CABLES. WESTINGHOUSE 37.5KVA, HV480, LV230.

12. REMOVE ALL POWER ASSIST DOOR ACTUATOR EQUIPMENT AND CONTROLS AND DELIVER TO LOCATION

SPECIFIED BY WPAFB CONTRACTING OFFICER.

E-3.0

ELECTRICAL BUILDING DEMOLITION PLANSCOVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

DECONSTRUCTION FACILITY 30089

PROJECT NO: 980636

RAMP DOWNUP

UP

UP

UP

R A

M P

U P

UP

UP

UP

UP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

UP

UP

DOWN

UP

UP

p r o je c to r s c r e e n

DN

UP

STEAM

PIT

VENT

SPRINKLER

DRAW OFF

SPRINKLER

DRAW OFF SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

VENT

SPRINKLER

DRAW OFF

UP

DF

C W

* MISC. SYSTEMS

FURNITURE* * MISC. SYSTEMS

FURNITURE*

DF

WH

UP

ELEV

MH

PHONE RACKS

VENT VENT

x x x x x x x x x x x x x x x x x x x

DF

PIT

BACKFLOW

VALVES

P H

O N

E R

O O

M

WH

PIT

*FURNITURE

STORAGE*

PT SD SD PT AIR

PT SD SD PT AIR

S P

R

WH

DF

DF

WH

S P

R

IN

K L

E R

R O

O M

F P

P A

N E

L

FP

PANEL

PT

SD

PT

DF

FND

P H

O N

E R

O O

M

UP

AIR HANDLER 4

VENT

x

FAN

FAN

HI HI

HI HI

HI

FAN

HI

HI

FAN FAN

HI

HIHI

HI

HI HI

FAN

HI

HI

HI

HI

HI

HIHI

FAN

HI HI

HI HI

HI

HI

HI

HI

HI

HI HI HI HI HI

HI

HI

HI

HI

HI

HI

HI

HI

FAN FAN

FAN

FAN

FAN

FAN

HI HI HIHI HI

F A

N

HI HI HI HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

HI

FAN

HI

HI

HIHIHIHIHIHIHIHIHI

HIHIHIHIHIHIHIHI

HI HI HI

FAN

FAN FAN

FAN

FAN

FAN

FAN

FAN

FAN

FAN

VENT

VENT VENT

PHONE

ROOM

UP

WH

WH

DF

DF

WH

DN

DN

STORAGE BALCONY

PT

PT

* MISC. SYSTEMS

FURNITURE*

* MISC. SYSTEMS

FURNITURE*

* MISC. SYSTEMS

FURNITURE*

* MISC. OFFICE

FURNITURE*

DN

DN

DN

D N

D N

AR-1.0

N/AFOUNDATION PLAN REFERENCE #1

* FOR REFERENCE ONLY *

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

AR-1.1

N/AFOUNDATION PLAN REFERENCE #2

* FOR REFERENCE ONLY *

COVER SHEET

JPRJKFJKF

26OF

DATEDRAWNDESIGNED CHECKED 30JULY10

DESIGN CHIEF

88TH ABW

WRIGHT-PATTERSON AIR FORCE BASE

BFAPW

AFUS

E

N

GE

L V

BYREVISIONNO.DATENO. BYREVISIONDATE

ENGINEERING CHIEFCOORDINATOR

073010 65% SUBMITTAL

95% SUBMITTAL091410

102210 95% RE-SUBMITTAL

FINAL SUBMITTAL012811

1634 DEMO T-1 Cover
1634 DEMO A 1-0
A-2.0
A-3.0
1634 DEMO A 4-0
1634 DEMO A 4-1
A-5.0
A-5.1
A-5.2
C-1.0
C-1.1
C-1.2
EV-1.0
L-1.0
P-1.0
P-1.1
1634 DEMO P 1-2
E-1.0
E-1.1
E-1.2
E-2.0
E-2.1
1634 DEMO E 3-0
M-1.0
M-1.1
1634 DEMO M 1-2
1634 DEMO AR 1-0
1634 DEMO AR 1-1

File details come from the government source that posted it. Updated .