200131_Pre-Bid RFIs_Asbestos Report_Att. 5.pdf

PDF 632 KB Posted

Attached to
Formal RFP for WWYK200131 - Repair Chilled Water System, Bldg. 2280
Solicitation number
FA813726R0010
Issued by

About this file

This document consists of a Polarized Light Microscopy Asbestos Analysis Report and an Asbestos Chain of Custody form for a mechanical room renovation project at Tinker Air Force Base.

The analysis report, dated June 15, 2022, documents asbestos testing performed by QuanTEM Laboratories (NVLAP accredited lab, Lab Code 101959-0) on six samples collected from Building 2280 West Mechanical Room at Tinker AFB. Samples were received on June 14, 2022, and analyzed using EPA/600/R-93/116 methodology. All six samples (ceiling tile, floor tile adhesive, paint, fiberboard, and insulation) tested negative for asbestos presence. Non-asbestos fiber compositions included cellulose, glass fiber, perlite, vinyl, calcium carbonate, binder, and paint. The analysis was conducted by Benjamin Hill, Assistant Laboratory Manager, for client Laura Duck in the Civil Engineering department under project numbers WWYK190068 and WWYK200131, with account number B731. The Chain of Custody form documents the sample handling from collection through analysis, including sample descriptions, colors, and tracking through the laboratory process. The report explicitly states it may not be reproduced without written laboratory approval and cannot be used to claim product endorsement by NVLAP or any U.S. Government agency.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Received: 06/14/2022

Project: Mechanical Room Reno

QuanTEM Lab No. 347428

Analyzed By: Benjamin Hill

Methodology: EPA/600/R-93/116

Polarized Light Microscopy Asbestos Analysis Report

Project Location: Bldg. 2280 West Mech Rm

Project Number: WWYK190068; WWYK200131

Account Number: B731

Received By: Baylie Longstreth

Date Analyzed: 06/15/2022

QuanTEM

Sample ID

Client

Sample ID Composition

Color /

Description Asbestos (%)

Non-Asbestos

Fiber (%)

Client: Tinker AFB - Civil Engineering

Laura Duck

Non Fibrous

001 GM220112 Homogeneous Perlite

Paint

Asbestos Not Present 50

Cellulose

Glass FiberCeiling Tile

White

002 GM220113 Layered CaCO3

Vinyl

Asbestos Not Present NA

Floor Tile

Tan/Brown

002a Layered GlueAsbestos Not Present NA

Adhesive

Yellow

002b Layered PaintAsbestos Not Present NA

Paint

Gray

003 GM220114 Layered BinderAsbestos Not Present 90Cellulose

Fiberboard

Brown

003a Layered PerliteAsbestos Not Present 30

Cellulose

Glass FiberInsulation

Brown/Tan

Date of Report

6/15/2022

Benjamin Hill, Assistant Laboratory Manager

QuanTEM is a NVLAP accredited Testing PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested.

NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods.

This report may not be used to claim product endorsement by NVLAP or any agency of the US Government.

This report may not be reproduced except in full, without the written approval of the laboratory.

Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.

File details come from the government source that posted it. Updated .