The file's text, extracted by GovTribe without its formatting.
Tech Eval 2015-582-4934-01 USAF AFMC 76 CMXG
76th Commodities Maintenance Engineering Group Oklahoma City Air Logistics Center Tinker Air Force Base
Technical Evaluation For Sheet Metal Guillotine Machine
Evaluation Performed By:
Date:
Name of Contractor:
Score (%):
Tech Eval 2015-582-4934-01 September 2015 Version 1
23 November 2015 Revision 1 Caution: This document may contain competitive, sensitive or other non-public information not intended for disclosure outside official government channels. Do not disseminate without the prior approval of the Office of the Assistant Secretary of the Air Force for Acquisition. No commitment of business related activity shall be interpreted because only a contracting officer can obligate the Government. If you are a recipient through error, please notify the sender and delete all copies of this document.
No classified data is contained herein.
Contents
| 1 Front Matter | 2 |
| 2 Pass and Fail Criteria | 2 |
| 3 General Features | 2 |
| 4 Mechanical | 2 |
| 5 Electrical | 3 |
| 6 Human Interface | 3 |
| 7 Safety | 3 |
| 8 Quality | 4 |
| 9 Maintenance | 4 |
| 10 Other | 4 |
| 11 – Reserved - | 4 |
| 12 Back Matter | 4 |
Front Matter This Technical Evaluation can be used as a checklist against SOW 2015-582-4934-01 to evaluate contractor submittals for the Sheet Metal Guillotine Machine. Compare the contractor’s proposal against the referenced paragraphs of SOW 2015-582-4934-01.
Pass and Fail Criteria If the requirement is sufficiently met, place a check mark (or X) in the “Verified” box. A passing evaluation for each item will show a check mark (or X) in each box. No check mark (or X) means that the item has failed to meet the requirement. Once completed, add the number of check marks and divide by 30. Write this number on the cover sheet in percentage form.
General Features
| Item |
| Description |
| SOW Para. |
| Verified |
| 1 |
| Three (3) mechanisms: un-coiler, straightener, cutoff machines. |
| 3.1 |
| □ |
| 2 |
| Capable of handling the raw material listed within SOW, Table 1. |
| 3.1 |
| □ |
Mechanical
| Item |
| Description |
| SOW Para. |
| Verified |
| 3 |
| Capable of variable production rate amd tolerances as listed in SOW and question answers. |
| 4 |
| □ |
| 4 |
| Steel mounting pads. |
| 4 |
| □ |
| 6 |
| Three (3) material carts, 20” mandrels, lockable wheels. |
| 4.1 |
| □ |
| 7 |
| A means for cart alignment and locking into position. |
| 4.1 |
| □ |
| 8 |
| Dedicated drive on the un-coiler; proper feed rate. |
| 4.1 |
| □ |
| 9 |
| Dedicated drive for the straightener. |
| 4.2 |
| □ |
| 10 |
| Straightener is adjustable for varying materials and thicknesses. |
| 4.2 |
| □ |
| 11 |
| Cutoff machine has upper & lower shear blades; adjustable gap. |
| 4.3 |
| □ |
| 12 |
| Detection of misalignment. |
| 4.3 |
| □ |
| 13 |
| Capable of holding tolerances of edge burr and part length. |
| 4.3 |
| □ |
| 14 |
| Dedicated drive for the cutoff machine |
| 4.3 |
| □ |
Electrical
| Item |
| Description |
| SOW Para. |
| Verified |
| 15 |
| Machine can use the available shop power. |
| 5.1 |
| □ |
| 16 |
| Single point grounding. |
| 5.2 |
| □ |
| 17 |
| Electrical enclosure. |
| 5.3 |
| □ |
| 18 |
| Electrical conduit. |
| 5.4 |
| □ |
| 19 |
| Control and Sensors |
| 5.5 |
| □ |
Human Interface
| Item |
| Description |
| SOW Para. |
| Verified |
| 21 |
| Touch Screen, PLC and Software are identified. |
| 6 |
| □ |
| 22 |
| PLC complies with IEC 61131 |
| 6.2 |
| □ |
| 23 |
| Software meets the listed criteria. |
| 6.3 |
| □ |
Safety
| Item |
| Description |
| SOW Para. |
| Verified |
| 24 |
| Safety criteria is met. (Includes signage and noise) |
| 7.1, 7.2, |
7.3
| 25 |
| Human Factors, Environmental and Occupational |
| 7.4, 7.5 |
| □ |
Quality
| Item |
| Description |
| SOW Para. |
| Verified |
| 26 |
| Standards of Manufacturing |
| 8.1 |
| □ |
| 27 |
| Quality Assurance |
| 8.2 |
| □ |
| 28 |
| Contractor agrees to daily clean up at installation. |
| 8.3 |
| □ |
| 29 |
| Contractor has planned for a Technical Interchange Meeting |
| 8.4 |
| □ |
Maintenance
| Item |
| Description |
| SOW Para. |
| Verified |
| 30 |
| Machine appears to be accessible for & capable of maintenance. |
| 9.1 |
| □ |
Other At the evaluator’s discretion, comments may be written below (Reserved) concerning the Contractor’s proposal.
– Reserved - Notes:
Back Matter ~ End of Document ~