Text version

2015-582-4934-01

Preliminary Installation Requirements

Date: 22 September 2015

PR# F3YCHS5280A002

Name of Requirement: Sheet Metal Guillotine Machine

Floor Space Required: 15’ W X 30’ L X 10’ H

Electrical Feed:

480 VAC, 208 VAC, 120 VAC

(Unknown amperages at this time.)

Shop Air: Standard line feed. (might be subject to change)

Noise abatement Not required. Machine shall not exceed 85 db. Full compliance with AFOSH 48-20, para 2.6 & 2.11

Machine Mounting Feet Supplied with steel mounting pads

Tap water Not required

Sewer access Not required

Special HVAC Not required

Forklift access Yes, required.

Approx. Machine Weight (Empty)

930 lbs.

Approx. Weight of a roll of Inconel loaded onto a cart

5,600 lbs.

Reference 2015-582-4934-01 Statement of Work (dated Sept 2014)