Solicitation Amendment FA812521R00040001 SF 30.pdf

PDF 526 KB Posted

Attached to
Pneumatic Test Cell Upgrade Federal contract opportunity
Solicitation number
FA8125-21-R-0004
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This document is an amendment to a solicitation for the upgrade of six pneumatic test cells. The solicitation seeks to replace components including skins, mufflers, and support structures to duplicate the functionality of existing test cells. The purpose of this amendment is to extend the response deadline to January 4, 2021 at 3:00 PM CST and provide answers to ten questions from potential offerors. The questions and answers clarify requirements such as available technical data, support calculations, spare parts, component replacements, testing responsibilities, and installation details. The solicitation is identified as number FA8125-21-R-0004 and is issued by the Air Force Sustainment Center on behalf of the Department of the Air Force Materiel Command.

View the file

Other files for this federal contract opportunity

Other files attached to Pneumatic Test Cell Upgrade, newest first.
File Type Posted
TAFB B200 Test Cell System Upgrade RFIs.pdf PDF
Pictures for Amendment 3.pdf PDF
Solicitation Amendment FA812521R00040003 SF 30.pdf PDF
Additional Pictures.pdf PDF
Silencer.pdf PDF
Ceiling_UniStrut.jpg JPG image
Solicitation Amendment FA812521R00040002 SF 30 (1).pdf PDF
Pneumatic Test Cell Upgrade Statement of Work .pdf PDF
Solicitation - FA812521R0004.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBE

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

The purpose of this amendment is to extend the solicitation date to 4 January 2021 at 3:00 PM CST as well The Purpose of This Amendment Is:

as post questions/answers as follows:

Question 1. Are TO's and Schematics available?

Answer 1: End Item TO's will be available. Must request through contracting and have a valid 2345.

Question 2: Because we are hanging items from the ceilings, we will need support capability calculations?

Answer 2: No Question 3: Are there test fixtures to be applied?

Answer 3: No Question 4: Are there spare requirements? One per set or one per kind?

Answer 4: Yes, it's located in the statement of work (SOW), see section 2.2.15.2 (1 whole set for all 6).

Question 5: Clarify replacement of black skin.

Answer 5: Replace everything for that cell back to the main unit. See SOW 2.2.7.8 and 2.2.7.9.

Question 6: Who will run correlation testing?

Answer 6: We will.

Question 7: When does warranty start?

Answer 7: A year from acceptance of each cell.

Question 8: Are we running all the way to the ceiling?

Answer 8: Yes, it will duplicate the current test cell.

Question 9: Will there be two mufflers per cell?

Answer 9: Yes Question 10: Will the existing muffler stay?

Answer 10: Yes

FA812521R00040001

IDCode:
Page: 1
Pages: 2
AmendNo: 0001
EffDate: 11/5/2020
ReqNo: A011536
ProjNo:
IssCode: FA8125
AdmCode:
IssuedBy: FA8125 AFSC PZIMA

3001 STAFF DR STE 2S76

CP 405 734 9107

TINKER AFB, OK 73145-3303

United States Sheridan Robison, Email: sheridan.robison@us.af.mil Telephone: 405-582-5686

AdminBy:
ContractorNameAdd:
Code:
FacCode:
SolChg: 1
SolNo: FA812521R0004
SolDate: 10/26/2020
AwardChg:
AwardNo:
AwardDate:
Amended: 1
OffrExt: 1
OffrNoEx: 1
NoCopies: 1
ApprData: See Section G
ChgeOrd:
ChgeOrder:
Modify:
SuppAgre:
SuppAuth:
ModOthr:
OthrSpec:
NoReq: 1
Require:
Copies:
Descript:

SEE CONTINUATION PAGE

ContNameTitle:
CoNameTitle: Darla J Deangelis

Email: darla.deangelis@us.af.mil Telephone: 339-2604

ContDate:
CODate:

File details come from the government source that posted it. Updated .