Questions & Answers for Altitude Chamber Test Stand Upgrade Part 2

FA8125-18-R-0003

1. Please confirm that the listed end items in Appendix D are currently tested being tested on the existing altitude chamber test system and IAW the applicable TOs.

Answer: Number 13, part number 82D38-3, tech order 15A2-2-179-3 should not be in Appendix D and is not a requirement for this SOW. Everything else is relevant.

2. What is the manufacture, part number of the vacuum pumps.

Answer: This information is not avaliable at this time. Once the information is avaliable, the government will provide.

3. Please provide available nameplate information such as manufacturer, part number, serial number for each valve listed in section 3.2.23 for replacement.

Answer: Reference Section 3.2.23.

The 16 inch (CSV_1 and CSV_2) valves are Crane Company part number 468509
The 12 inch (VCV_1 and VCV_2), 4 inch (BV_1 and BV_2), 3 inch (BV3_1 and BV3_2), 10 inch PCV_1 are all Philadelphia Gear Works "Limitorque" valves. The data plates aren't legible enough to provide exact details on part numbers.There isn't labeling to determine information for PSV_1, PBV_1, FCV_4A through D, Still working to get data for sections 3.2.23.9, 3.2.23.10, 3.2.23.11, and 3.2.23.12.

4. Reference section 5.4.3. What will be the required correlation pass fail parameters? Typically pass/ fail correlation parameters establish an acceptable average deviation of 3 test runs and compare results from pre and post upgrade to be within +-5%.

Answer: Reference Section 5.4.3. We will run the 6 valves 3 times each on the test stand prior to work beginning and record the total variance of values. Those exact same valves will be used for the correlation testing when the stand is finished and yes we agree with the results to within +- 5%.

5. Reference section 6.1.1 Technical Data. The government references an Illustrated Parts Breakdown. Will the government accept annotated photographs and tables in place of illustrations?

Answer: Reference Section 6.1.1. Yes, we will accept annotated photographs and tables in place of illustrations.

6. Will the government accept vendor data for parts breakdown of commercial purchased items such as valves, actuators, instrumentation, controls?

Answer: Yes we will accept vendor data for parts breakdown of commercial purchased items such as valves, actuators, instrumentation, and controls.