Appendix_A1-RO_PMXG_Maintenance_Contract.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- Repair of PMXG Reverse Osmosis System Federal contract opportunity
- Solicitation number
- FA8125-15-R-0010
About this file
Appendix A-1
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 2263-203.pdf | ||
| EP-090134-03-01_Sheet_1.pdf | ||
| EP-090134-03-01_Sheet_2.pdf | ||
| 2263-201.pdf | ||
| PLOT_PLAN.pdf | ||
| EP-090134-03-03.pdf | ||
| tinker_map.JPG | JPG image | |
| Wage_Determination_Dated_Version_19_Dated_(December_22_2014).pdf | ||
| FA8125-15-R-0010 _Solicitation_13_April_2015.pdf | ||
| Appendix_A2-RO_PMXG_Maintenance_Contract.xls | XLS spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| # | Description | Manufacturer | Model No. | OC No. | PM | Location |
| 1 | 400 GPM Reverse Osmosis System | Marlo, Inc. | MRO-576K-8H | OC20140 | X | B3001, H-104 |
| 2 | High Pressure Pump/Motor - RO feed pumps | Baldor | 85600034 | X | ||
| 2 | Prefilter Tank | Shelco | 12FOS4 | X | ||
| 1 | CIP Filter Tank | Shelco | 7FOS4 | X | ||
| 56 | Manual Valves (4 throttle) | |||||
| 4 | Chemical Pumps | Pulsatron | LB64SA-VTC1-XX2 | X | ||
| 4 | Conductivity Sensors | George Fisher | X | |||
| 22 | Pressure Gauges | |||||
| 2 | Temperature Gauges | |||||
| 14 | Pressure Transducers | IFM Efector, Inc. | ||||
| 2 | Ultrasonic Level Transducer | |||||
| 2 | Oxidation/Reduction Potential Sensor (ORP) | George Fisher | X | |||
| 2 | pH sensors | George Fisher | ||||
| 3 | Flow Meters | MBLD Instrument Co. | X | |||
| 6 | Solenoid Valve | Morin | MRP-014U-D000 | |||
| 1 | CIP Pump | Leeson | C184T34FK15D | X | ||
| 4 | Booster Pump | Leeson | C215T34FK10AA | X | ||
| 16 | Composite Polyamide Membrane Elements | Codeline | 80A30 | X | ||
| 96 | Reverse Osmosis Membranes | Toray | TML-20-400 | X | ||
| 1 | UV Sterilizer | Aquafine | SL-1 | X | ||
| 1 | 100 GPM Reverse Osmosis System | LT Technologies | OC19792 | X | B3001, S-91 | |
| 2 | Prefilter | Shelco 4FOS3 | X | |||
| 2 | Prefilters - Bag Filter | Shelco BFS-2SB-2 | X | |||
| 7 | Pressure Transducer | |||||
| 15 | Pressure Gauge | |||||
| 4 | Conductivity Sensor | Thornton | X | |||
| 1 | Level Transducer | |||||
| 2 | Temperature Sensor | |||||
| 2 | pH Sensor | |||||
| 57 | Manual Ball Valve | |||||
| 8 | Solenoid Valve | Asahi/America | ||||
| 2 | High Pressure Pump - RO Feed Pump | Grundfos | A96523644 - P10838574 | X | ||
| 1 | High Pressure Pump - Permeate Distribution | A96523641-P10838602 | X | |||
| 7 | Flow Meter | King | X | |||
| 6 | Composite Polyamide Membrane Elements | Codeline | 80A30 | X | ||
| 1 | Bladder Tank | Amtrol, Inc | WX-302 | |||
| 1 | UV Lamp | Atlantic UV | X | |||
| 1 | Agitator | Liquid Metronics | 10590A | |||
| 1 | Post Treatment Filter | Big Blue | X | |||
| 2 | Pretreatment Pump (anti-scalant) | LMI | P161-468SI | X | ||
| 2 | Pretreatment Pump (SBS) | Pulsatron | LB03SA-VTC1-XX2 | X | ||
| 16 | Reverse Osmosis Membranes | Toray | TMG20-400C, 8"x40" | X |
| Pretreatment Chemical | ||
| 3 | Sodium Metabisulfite | X |
| 3 | Anti-scalant | X |