Attachment_1.pdf
PDF 1 MB Posted
- Attached to
- Stadium Cabling Federal contract opportunity
- Solicitation number
- FA700018Q0005
About this file
Attachment 1 Cable runs
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Cable_question.pdf | ||
| Attachment_3_-_Falcon_Stadium_Map_Locations.pdf | ||
| CBS_Cable_Lengths.pdf | ||
| Revised_Combined_Synopsis_-Stadium_Cabling_31_May_18.docx | DOCX document | |
| WD_2015-5417_Rev9_Attachment_4.pdf | ||
| Revised_Cabling_PWS_final_31_May_18.docx | DOCX document | |
| Cabling_PWS_final.docx | DOCX document | |
| Attachment_3_-_Falcon_Stadium_Map_Locations.pdf | ||
| Attachment_2.pdf | ||
| Combined_Synopsis_-Stadium_Cabling_29_May_18.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Requirements to Pre Cable Falcon Stadium for TV Trucks
Audio:
From TV Truck dock panel to national television booth
1. 3 DT 12 Cables
2. 36 XLR Cables with both male and female ends
From TV Truck dock panel to west side 50 Yard line on stadium floor
1. 2 DT 12 Cables
2. 24 XLR Cables with both male and female ends
From TV Truck dock panel to east side 50 yard line on stadium floor
1. 1 DT 12 Cable
2. 12 XLR Cables with both male and female ends
From TV Truck dock panel to 3rd Level Press Box Media Room
1. 6 XLR Cables with both male and female ends
From TV Truck Panel to Camera Platform at Section M7
1. 2 XLR Cables with both male and female ends.
From TV Truck Panel to Camera Platform at Section M8
1. 2 XLR Cables with both male and female ends.
From TV Truck Panel to Camera Platform at Section M9
1. 2 XLR Cables with both male and female ends.
Fiber:
From TV Truck dock panel to Camera Platform at Section M7
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to Camera Platform at Section M8
1. 12 single mode fiber with ST Connection
Attachment 1 1
From TV Truck dock panel to Camera Platform at Section M9
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to Camera Platform at top of south video board
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to north wall field level
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to south wall field level
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to national television booth
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to east side 50 yard line on stadium floor
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to west side 50 yard line on stadium floor
1. 12 single mode fiber with ST Connection
From TV Truck dock panel to Press Box Roof
1. 6 single mode fiber with ST Connection
From TV Truck dock panel to Section U13
1. 6 single mode fiber with ST Connection
From TV Truck dock panel to 3rd Level Press Box Media Room
1. 6 single mode fiber with ST Connection
Coax:
From TV Truck Dock panel to national television booth
1. 10 coax cables with BNC connections
Attachment 1 2
From TV Truck dock panel to west side 50 yard line on stadium floor
1. 8 coax cables with BNC connections
From TV Truck dock panel to east side 50 yard line on stadium floor
1. 8 coax cables with BNC connections
From TV Truck dock panel to Press box roof
1. 4 coax cables with BNC connections
From TV Truck dock panel to 3rd level press box media room
1. 4 coax cables with BNC connections
From TV Truck dock panel to top of section U13
1. 4 coax cable with BNC connections
Triax and SMPTE Fiber:
From TV Truck dock panel to camera platform at section M7
1. 1 Triax cable
2. 1 SMPTE Fiber Cable
From TV Truck dock panel to camera platform at section M8
1. 2 Triax cables
2. 2 SMPTE Fiber Cables
From TV Truck dock panel to camera platform at section M9
1. 1 Triax cable
2. 1 SMPTE Fiber Cable
From TV Truck dock panel to top of section U13
1. 1 Triax cable
2. 1 SMPTE Fiber Cable
From TV Truck dock panel to top of scoreboard on south end of stadium
1. 2 Triax cables
2. 2 SMPTE Fiber Cables
Attachment 1 3
From TV Truck dock panel to west side 50 yard line on stadium floor
1. 3 Triax cables
2. 3 SMPTE Fiber Cables
From TV Truck dock panel to east side 50 yard line on stadium floor
1. 2 Triax cables
2. 2 SMPTE Fiber Cables
From TV Truck dock panel to north wall field level
1. 2 Triax cables
2. 2 SMPTE Fiber Cables
From TV Truck dock panel to south wall field level
1. 2 Triax cables
2. 2 SMPTE Fiber Cables
Attachment 1 4