This Request for Quote (RFQ) solicits proposals to maintain the AMXS Office area in Building 821 at the 934th Airlift Wing in Minneapolis, Minnesota. Key details include maintaining approximately 2,400 square feet of office space including demolishing and removing existing finishes and fixtures, installing new flooring, wall base, window sills, millwork, and electrical and data systems. Quotes are due by the date specified in Block 13 of the Standard Form 1442 and must remain valid for 90 days. The project will be awarded as a firm-fixed-price contract to the lowest priced technically acceptable offeror. The acquisition is set aside for small businesses only and has a magnitude between $100,000 and $250,000. The period of performance is 120 calendar days from notice to proceed. The applicable wage determination is for Hennepin County, Minnesota.

View the file

Other files for this federal contract opportunity

Other files attached to AMXS Office Remodel, B821, newest first.
File Type Posted
QandA for RFQ B821 AMXS.docx DOCX document
Attach. 1 QJKL 24-9991D SOW.pdf PDF
Attach. 2 QJKL 24-9991D Specifications.pdf PDF
Attach. 5 QJKL 24-9991D Submittal Register.xlsx XLSX spreadsheet
Solicitation - FA663324Q0001.pdf PDF
Attach. 4 2024026 Wage Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

TI

TL

E

D

R

AW

IN

G

IN

D

EX

PR

O

JE

C T

-9

1B

R

EP

AI

R

A M

XS

O

FF

IC

E M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

T-001

BLDG-821

AN

SI

D

MINNEAPOLIS AIR RESERVE STATION

PROJECT 24-9991D

SUSTAIN AMXS OFFICE, B821

FINAL DESIGN - READY TO ADVERTISE

09 JANUARY 2024

4 TH

T W

LRIA I

G

N

I F

934TH CEC DESIGN TEAM

C

EC

IN

-H

O U

SE

D

ES

IG

N

DRAWING INDEX

SHEET DESCRIPTION

T-001 TITLE - DRAWING INDEX

G-001 PROJECT LOCATION

AD-101 DEMOLITION PLAN

AD-102 FLOOR COVERING DEMOLITION PLAN

AD-103 REFLECTED CEILING DEMOLITION

A-101 NEW WORK PLAN

A-102 FLOOR & WINDOW SILL FINISH PLAN

A-103 FURNITURE PLAN

A-601 SCHEDULES

ED-101 ELECTRICAL DEMOLITION PLAN

E-101 POWER & DATA PLAN

9 3 4

TH

T W

RI

A

I G

N

F

PROJECT

LOCATION

934TH MAIN GATE

VICINITY MAP- NOT TO SCALE

TH

A

VE

NORTH

ACCESS

GATE

257A

251E

251D

251B

251A

257A

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

PR

O

JE

C T

LO

C

AT

IO

N

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

G-001

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

C

EC

IN

-H

O U

SE

D

ES

IG

N

PRJOECT LOCATION 2ND FLOOR

NORTH

GENERAL NOTES

1. BUILDING 821 IS LOCATED IN A CONTROLLED AREA. THE

CONTRACTOR WILL BE REQUIRED TO STAY WITHIN THE

BOUNDARIES OF THE ESTABLISHED "FREE ZONE" OR BE ESCORTED

BY AN AUTHORIZED GOVERNMENT REPRESENTATIVE.

2. THE FACILITY WAS CONSTRUCTED IN THE 1940'S AND IS KNOWN TO

CONTAIN ASBESTOS BUILDING MATERIALS. ASBESTOS CONTAINING

FLOOR TILE AND MASTIC WERE PRESENT IN THE PROJECT AREA AT

ONE TIME BUT ARE BELIEVED TO HAVE BEEN REMOVED. IF

RED/BROWN FLOOR TILE AND BLACK MASTIC ARE DISCOVERED

DURING CONSTRUCTION, IMMEDIATELY CEASE OPERATIONS AND

CONTACT THE PROJECT ENGINEER.

3. THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF

EXISTING CONDITIONS AND FIELD MEASUREMENT. NOTIFY THE

PROJECT ENGINEER IF CONDITIONS DIFFER FROM THOSE

DISPLAYED IN THESE DRAWINGS.

4. THE PROJECT AREA IS PROTECTED BY A WET PIPE FIRE

SUPPRESSION SYSTEM. RISER IS LOCATED IN THE EAST

MECHANICAL ROOM SOUTH OF THE EMERGENCY GENERATOR.

CALL 612-713-1919 FOR TECHNICAL ASSISTANCE.

5. CONTRACTOR TO PROVIDE RED LINED DRAWINGS REFLECTING

AS-BUILT CONDITIONS UPON PROJECT COMPLETION.

USE THIS ENTRANCE

NTS

WORK AREA - BUILDING 821A1

PARKING/LAYDOWN AREA

FR

EE

Z O

N E

BID OPTION LOCATION

257257A

A.E.D.

254259

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

TI

O D

EM

O

LI

TI

O N

P

LA

N

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

AD-101

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

Scale: 1/4"=1'

DEMOLITION PLANA1

DEMO KEY NOTES

DEMO INTERIOR WALL AND DOORS. INCLUDES GYP. BD, STUDS, &

TRACK UP TO ROOF DECK, ALSO INCLUDES 6 DOORS, DOOR

FRAMES, AND HARDWARE. SEE GENERAL NOTE 1- 3 THIS SHEET.

DEMO ROLL UP WINDOW. INCLUDES TRACK, FRAME, AND

ACCESSORIES.

DEMO BREAK ROOM SINK, FAUCET, COUNTERTOP, UPPER &

LOWER CABINETS.

REMOVE TRAINING MONITOR & WALL MOUNT. SAVE FOR REUSE.

DEMO FIRE EXTINGUISHER CABINETS. SAVE EXTINGUISHER.

REMOVE A.E.D. AND CABINET. PRESERVE FOR REUSE.

DEMO LAMINATE WINDOW SILLS. PREPARE FOR NEW SOLID

SURFACE MATERIAL.

DEMO DOOR LEVER HANDLES.

DEMO GLASS DISPLAY CASE

ITEMS TO DEMOLISH

GENERAL NOTES:

1. THE CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENT

AND VERIFICATION OF EXISTING CONDITIONS. NOTIFY THE

PROJECT ENGINEER IF CONDITIONS DIFFER FROM THOSE

DEPICTED IN THESE DRAWINGS.

2. WALL DEMOLITION INCLUDES GYPSUM BOARD, METAL STUDS,

INSULATION, UPPER AND LOWER TRACKS, DOORS, AND DOOR

FRAMES UNLESS OTHERWISE NOTED.

3. SAVE ALL DOOR CLOSING DEVICES AND HARDWARE.

4. HVAC DUCTING TO REMAIN UNDISTURBED. ITEMS ATTACHED

TO WALLS TO BE REMOVED SHALL BE SECURED TO 2ND FLOOR

DECK USING STANDARD INDUSTRY PRACTICES.

5. DEMOLISH (DEMO) MEANS TO REMOVE AND DISPOSE OF ALL

ITEMS IDENTIFIED BY KEYNOTES AND AS DEPICTED WITH

HATCHING.

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

251D251E

251A 251B

HALLWAY 251F

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

FL

O O

R C

O

VE

R

IN

G D

EM

O

LI

TI

O N

P

LA

N

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

AD-102

BLDG-821

WI

NG

I F

TLRI

A

934 TH

AN

SI

D

Scale: 1/4"=1'

FLOOR COVERING DEMOLITION PLANA

DEMO KEY NOTES

REMOVE AND DISPOSE OF APPROXIMATELY 1,700 SF OF CARPET

AND UNDERLYING GLUE. PREPARE FLOOR FOR NEW FINISH. SEE

ASBESTOS WARNING THIS SHEET.

REMOVE AND DISPOSE OF APPROXIMATELY 608 SF OF VINYL

FLOOR TILE AND GLUE. SEE CAUTION FROM KEY NOTE 1. TILE ON

SOUTH END OF HALLWAY TO REMAIN AS SHOWN.

REMOVE AND DISPOSE OF VINYL WALL BASE AND ADHESIVE

THROUGHOUT.

DEMO CARPET TILE

DEMO FLOOR TILE

Scale: 1/4"=1'

BID OPTION - FLOOR COVERING DEMOLITION PLANB

REMOVE AND DISPOSE OF APPROXIMATELY 1,000 SF OF CARPET,

UNDERLYING GLUE, AND WALL BASE. PREPARE FLOOR FOR NEW

FINISH. SEE ASBESTOS WARNING THIS SHEET.

ASBESTOS WARNING

ORIGINAL FLOOR TILE AND MASTIC IN THE REPAIR AREA

ORIGINALLY CONTAINED ASBESTOS BUT IS BELIEVED TO HAVE

BEEN REMOVED. IF RED OR BROWN TILE WITH BLACK MASTIC IS

ENCOUNTERED DURING DEMOLITION, CEASE OPERATIONS AND

CONTACT THE PROJECT ENGINEER.

DEMO LEGEND

BID OPTION KEY NOTES

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

EX

IT

EXIT# # # # # #

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

R

EF

LE

C

TE

D C

EI

LI

N G

D

EM

O

LI

TI

O

N

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

AD-103

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

Scale: 1/4"=1'

REFLECTED CEILING DEMOLITIONA

DEMO KEY NOTES

REMOVE AND DISPOSE OF APPROXIMATELY 2,400 SF ACOUSTIC

CEILING PANEL SYSTEM. INCLUDES GRID, SUSPENSION WIRE,

AND PANELS. SEE GENERAL NOTES THIS SHEET.

NORTH

PAGING/MNS SPEAKER

SPRINKLER HEAD

GENERAL NOTES

1. PROTECT SPRINKLER HEADS FROM DAMAGE.

2. LIGHT FIXTURES ARE TO REMAIN AND ARE NOT INCLUDED IN

THIS CONTRACT. PRESERVE FOR REUSE.

3. ALL DEVICES (PAGING SPEAKERS, FIRE ALARM HORNS/STOBES,

MASS NOTIFICATION SPEAKERS, ETC) ARE TO BE REINSTALLED

ON THE NEW CEILING PANEL SYSTEM WITH THE EXCEPTION OF

BLANK COVERS AND UNNECESSARY EXIT SIGNS.

4. LAY OUT NEW GRID TO ENSURE SPRINKLER HEADS ARE

UNIFORMLY CENTERED IN NEW PANELS AS CLOSE AS

POSSIBLE. IF SPRINKLER HEAD ADJUSTMENT IS NECESSARY,

NOTIFY THE PROJECT ENGINEER FOR SYSTEM

DEPRESSURIZATION. ALL SPRINKLER SYSTEM ADJUSTMENT

MUST BE COMPLETED PRIOR TO INSTALLATION OF ANY

FINISHES.

5. CONTRACTOR TO FIELD VERIFY LOCATIONS AND QUANTITIES

OF CEILING MOUNTED DEVICES AND REPORT DISCREPANCIES

OR RECOMMENDATIONS TO THE PROJECT ENGINEER.

LEGEND

FIRE ALARM HORN/STROBE

BLANK COVER

DEMO ITEMS WITH CROSS HATCH

EXIT SIGN EXIT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

A.E.D.

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

N

EW

W

O R

K

PL

AN

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

A-101

BLDG-821

WI

NG

I F

TLRI

A

934 TH

AN

SI

D

SHEET KEY NOTES

FURNISH AND INSTALL 8 EA WILSONART SOLID (DUSK ICE)

WINDOW SILLS (WS1). SEE SCHEDULE.

REINSTALL TRAINING MONITOR USING EXISTING MOUNT IN

ORIGINAL LOCATION.

FURNISH AND INSTALL BASE & WALL CABINETS, SOLID SURFACE

COUNTERTOP WITH MATCHING 4" BACK SPLASH, SINK AND

FAUCET. SEE DETAILS AND SCHEDULE.

REINSTALL A.E.D. AND CABINET.

REPLACE DOOR LEVER HANDLES. SEE SCHEDULE ON SHEET

A-102. LOCK CYLINDERS AND KEYS PROVIDED AND INSTALLED BY

THE GOVERNMENT LOCKSMITH.

A1 A101

Scale: 1/4"=1'

NEW WORK PLAN1

SOLID SURFACE

COUNTERTOP,

BACK & SIDE

SPLASH (SSM)

WALL CABINETE (WC)

SINK (SK1)

Scale: 3/4"=1'

RM 259 ELEVATIONA1

REFRIGERATOR

(GFGI) FAUCET (FCT)

BASE CABINET (BC)

Scale: 3/4"=1'

MILLWORK SECTIONA2

Scale: 3/4"=1'

MILLWORK SECTIONA3

ADJUSTABLE SHELF

ADJUSTABLE SHELF STANDARD

LIGHT MAPLE INTERIOR FINISH

1X BLOCKING

4" PLYWOOD DOOR

DOOR PULL (AS SCHEDULED)

A2 A101

A3 A101

NORTH

ADJUSTABLE SHELF

(EXCLUDED ON SINK BASE)

LIGHT MAPLE INTERIOR FINISH

34" PLYWOOD DOOR

DRAWER PULL AS SCHEDULED

4"X 3" RECESSES WITH

FINISHED FRONT

2" SOLID SURFACE BACK

& SIDE SPLASH (SSM)1

2" SOLID SURFACE TOP ON 34"

PLYWOOD WITH BEVELED EDGE

8" DOVE-TAILED DRAWER BOXES W/

UNDERMOUNT FULL-EXTENTION

SLOW CLOSE DRAWER SLIDES

(DRAWER EXCLUDED ON SINK BASE)

SLOW CLOSE DOOR HINGES

SLOW CLOSE DOOR HINGES

SINK BASE (SBC)

MATCHING FINISHED FRONT FACE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

257257A 254259

251D251E

251A 251B

HALLWAY 251F

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

FL

O O

R

W

IN

D O

W S

IL

L

FI

N

IS

H

P

LA

N

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

A-102

BLDG-821

WI

NG

I F

TLRI

A

934 TH

AN

SI

D

FINISH NOTES

FURNISH AND INSTALL APPROXIMATELY 1,700 SF OF CARPET TILE

FURNISH AND INSTALL RUBBER WALL BASE (RB1) PER SCHEDULE

OR APPROVED EQUIVALENT IN ALL ROOMS RECEIVING NEW

FLOOR FINISHES.

PROVIDE TRANSITION STRIP TS1 WHERE NEW FLOOR FINISHES

DIFFER AS SCHEDULED. CENTER TRANSITION STRIP UNDER

CLOSED DOORS.

ALL CARPET TILE INSTALLATION WILL BEGIN WITH A FULL TILE

CENTERED IN THE ROOM UNLESS DOING SO WILL RESULT IN

LESS THAN A 3 INCH WIDE TILE AT THE ROOM PERIMETER,

ADJUST STARTING TILE AS NECESSARY TO PREVENT.

ALL LUXURY VINYL TILE WILL BE INSTALLED SO THAT NO TILE

WILL BE LESS THAN HALF A TILE WIDTH AT THE PERIMETER.

CPT1 - CARPET TILE

Scale: 1/4"=1'

BID OPTION - MAINT. OPERATIONS CENTER FINISH PLAN A1

Scale: 1/4"=1'

FLOOR AND WINDOW SILL FINISH PLANA2

FURNISH AND INSTALL APPROXIMATELY 1,000 SF OF CARPET TILE

CPT1 IN 251A THRU 251D PLUS HALLWAY. INCLUDES NEW WALL

BASE THROUGHOUT.

FINISH LEGEND

LVT1 - LUXURY VINYL TILE

BID OPTION NOTES

SSM - SOLID SURFACE MATERIAL

ROOM FINISH SCHEDULE

ROOM # FLOOR

FINISH

WALL

BASE

WALL

PAINT

DOOR

PAINT

CEILING

FINISH

251A CPT1 RB1 N/A N/A N/A

251B CPT1 RB1 N/A N/A N/A

251D CPT1 RB1 N/A N/A N/A

251E CPT1 RB1 N/A N/A N/A

251F CPT1 RB1 N/A N/A N/A

254 CPT1 RB1 PT1 PT2 ACP1

257 CPT1 RB1 PT1 PT2 ACP1

257A CPT1 RB1 PT1 PT2 ACP1

259 LVT1 RB1 PT3 PT2 ACP1

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

9'

5'

4'

4'

PRT

PRT

CAB

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

FU

R N

IT

U

R E

PL

AN

PR

O

JE

C

T

-9

1D R

EP

AI

R A

M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R R

ES

ER

VE

S

TA

TI

O N

M N

A-103

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

Scale: 1/4"=1'

FURNITURE PLAN1

SHEET NOTES

1. FURNITURE IS FOR PLANNING PURPOSES ONLY AND IS NOT

INCLUDED IN THIS PROJECT.

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

SC

H

ED

U

LE

S

PR

O

JE

C T

-9

1D

R

EP

AI

R

A M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R

R

ES

ER

VE

S

TA

TI

O

N M

N

A-601

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

FINISH SCHEDULE

I.D. DESCRIPTION MANUFACTURE COLOR/ P/N NOTES

CPT1 CARPET TILE 24" X 24" BENTLEY REDACTED/ DOCUMENT 801520 6,7

LVT1 LUXURY VINYL TILE HARPERS PLACE VICTORIAN HP39 6,7

PT1 PAINT (WALL) SHERWIN WILLIAMS SW7015 REPOSE GREY 8

PT2 PAINT (DOOR FRAME) SHERWIN WILLIAMS SW7642 PAVESTONE 9

PT3 PAINT (WALL) SHERWIN WILLIAMS SW6204 SEA SALT 8

RB1 VINL WALL BASE TARKETT 32 PEBBLE COVE 10

ACCESSORY SCHEDULE

I.D. DESCRIPTION MANUFACTURE COLOR/ P/N NOTES

SK1 KITCHEN SINK ELKAY CROSSTOWN S.S. 24" 4

FCT KITCHEN FAUCET KOHLER BRUSHED NICKEL/FORTE 5

CABINET & COUNTER SCHEDULE

I.D. DESCRIPTION MANUFACTURE COLOR/ P/N NOTES

SB SINK BASE CABINET 36"X34.5"X24" TBD CLEAR COAT WALNUT 1

BC BASE CABINET 36"X34.5"X24" TBD CLEAR COAT WALNUT 1

WC WALL CABINET 36"X36"X12" TBD CLEAR COAT WALNUT 1

SSM SOLID SURFACE MATERIAL WILSONART DUSK ICE/ 9203CE 2

DOOR SCHEDULE

I.D. DESCRIPTION MANUFACTURE COLOR/ P/N NOTES

DLH DOOR LEVER HANDLES USCAN USL150D-IC-626 2-34 3

SCHEDULE NOTES

1 LIBERTY MANDARA/SATIN NICKEL PULL HANDELS W/ 5.0625" SPACING

2 MATCHING 4" BACK & SIDE SPLASH

3 CORE TO BE FURNISHED & INSTALLED BY GOV'T

4 UNDERMOUNT SINK

5 SINGLE HANDLE WITH PULLOUT

6 GLUE DOWN. ORIENT LVT EAST/WEST, CARPET ASHLAR PATTERN

7 SCHLUTER, RENO-U ANODIZED ALUMINUM TRANSITION STRIP

8 EGSHELL FINISH

9 SEMI-GLOSS

10 4X4X1

8" COVE

GENERAL NOTES:

1. LISTED PRODUCTS ARE BASIS OF DESIGN AND ARE INTENDED

TO REFERENCE THE MINIMUM QUALITY AND PERFORMANCE

REQUIREMENTS. ANY PRODUCTS THAT MEET THE SALIENT

CHARACTERISTICS OF THESE PRODUCTS MAY BE USED.

2. ANY BARE GYPSUM BOARD TO RECEIVE PAINT SHALL BE

COATED WITH M IN. 1 COAT OF SHERWIN WILLIAMS

MULTI-PURPOSE LATEX PRIMER.

3 ALL AREAS TO RECEIVE PAINT WILL BE COATED WITH MIN. 2

FINISH COATS.

L11 L11 (1)L11 (11)

DATADATA DATA DATA DATAT

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

EL

EC

TR

IC

AL

D

EM

O

LI

TI

O

N P

LA

N

PR

O

JE

C

T

-9

1D R

EP

AI

R A

M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R R

ES

ER

VE

S

TA

TI

O N

M N

ED-101

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

Scale: 1/4"=1'

ELECTRICAL DEMOLITION PLANA1

SHEET KEY NOTES

REMOVE ELECTRICAL FROM HALLWAY WALLS. INCLUDES

ELECTRICAL, DATA, LIGHT SWITCHING, TELEPHONE, AND

ABANDONED OR EMPTY BOXES/DROPS. DISCONNECT

THERMOSTAT. PRESERVE DATA AND THERMOSTAT CABLES FOR

REUSE.

ELECTRICAL

REMOVAL INCLUDES COVER PLATES, RECEPTACLES, SWITCHES,

BOXES, CONDUIT, CONDUCTORS, AND ASSOCIATED HARDWARE.

EXISTING BREAKERS, CONDUIT, AND CONDUCTORS MAY BE

REUSED AND/OR EXTENDED WHERE POSSIBLE. IF NOT REUSED,

DEMOLISH CONDUCTOR AND CONDUIT BACK TO POWER PANEL,

REMOVE BREAKER, AND UPDATE LEGEND.

ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE

WITH THE NATIONAL ELECTRIC CODE.

COMMUNICATIONS

DATA CABLE SUPPORTING EXISTING DATA RECEPTACLES TO BE

REMOVED SHOULD BE PRESERVED AT FULL LENGTH TO

FACILITATE REUSE.

UNUTILIZED CABLE TO BE COILED AND TIED ABOVE THE CEILING

GRID. DO NOT LAY CABLE DIRECTLY ON THE CEILING GRID OR

ACOUSTIC PANELS.

ELECTRICAL RECEPTACLE

DATA RECEPTACLE

THERMOSTAT

GENERAL NOTES

DATA

T

LEGEND

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

L11

D

AT

A

T

DATA

D

ATA

D

ATA

DATA

D

AT

A

9' -5

10'-11"

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

T.

T

IO

C . D

AU

W

AL

TE

R

C . D

AU

W

AL

TE

R

T.

T

IO

PO

W

ER

D

AT

A

PL

AN

PR

O

JE

C

T

-9

1D R

EP

AI

R A

M

XS

O

FF

IC

E

AR

EA

M

IN

N

EA

PO

LI

S

AI

R R

ES

ER

VE

S

TA

TI

O N

M N

E-101

BLDG-821

WI NG

I F TLRIA

934 TH

AN

SI

D

Scale: 1/4"=1'

POWER & DATA PLANA1

SHEET KEY NOTES

INSTALL SURFACE MOUNT QUAD POWER & DATA RECEPTACLES

TO ACCOMMODATE NEW WORK STATIONS. USE EXISTING DATA

CABLE. EXTEND EXISTING WIRING AND/OR INSTALL NEW

CIRCUITS FROM PANEL L11. SEE FURNITURE LAYOUT ON SHEET

A-103.

INSTALL DUPLEX POWER 20A RECEPTACLES.

REMOUNT THERMOSTAT ON GYPSUM BOARD WALL.

FURNISH AND INSTALL TWO 10' GREY ALUMINUM POWER/DATA

POLES EACH WITH 2 DUPLEX RECEPTACLES AND 2 DUPLEX DATA

PORTS TO SUPPORT 8 WORK STATIONS.

REMOUNT AND CONNECT EMERGENCY LIGHTS AS SHOWN.

CONFIGURE EXISTING 3-WAY LIGHT SWITCHES TO CONTROL ALL

ROOM 257 AND PREVIOUS HALLWAY LIGHTS

ELECTRICAL ITEMS SHOWN ARE FOR BIDDING PURPOSES ONLY.

CONDUCTOR SIZES, BREAKERS SIZES, AND OTHER ITEMS ARE

ESTIMATES. DESIGN PROFESSIONAL SHALL CONFIRM ALL ITEMS.

ELECTRICAL INSTALLATION INCLUDES COVER PLATES,

RECEPTACLES, SWITCHES, BOXES, CONDUIT, AND CONDUCTORS.

EXISTING BREAKERS, CONDUIT, AND WIRE MAY BE

REUSED/EXTENDED WHERE SUFFICIENT LENGTH PERMITS.

INSTALL WHITE RECEPTACLES, SWITCHES, AND FACE PLATES.

LABEL DATA AND ELECTRICAL RECEPTACLES. SEE SPEC.

EDIT POWER PANEL DIRECTORY TO REFLECT NEW OR CHANGED

CIRCUITS.

ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE

WITH THE NATIONAL ELECTRIC CODE.

GENERAL NOTES

DATA

T

LEGEND

NORTH

DUPLEX RECEPTACLE

QUADRAPLEX RECEPTACLE

4 PORT DATA RECEPTACLE WITH BLUE CAT 6 CABLE AND

WHITE FACE PLATE. INSTALL ACCORDING TO WORK

STATIONS SUPPORTED. SEE SHEET A-103.

THERMOSTAT

EMERGENCY LIGHT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'

Sheets and Views
AMXS Sustainment 2024-T-001
AMXS Sustainment 2024-G-001
AMXS Sustainment 2024-AD-101
AMXS Sustainment 2024-AD-102
AMXS Sustainment 2024-AD-103
AMXS Sustainment 2024-A-101
AMXS Sustainment 2024-A-102
AMXS Sustainment 2024-A-103
AMXS Sustainment 2024-A-601
AMXS Sustainment 2024-ED-101
AMXS Sustainment 2024-E-101
__T001.pdf
Sheets and Views
T-001
A101.pdf
Sheets and Views
A-101
A101.pdf
Sheets and Views
A-101
AD102.pdf
Sheets and Views
AD-102
AD102.pdf
Sheets and Views
AD-102
A102.pdf
Sheets and Views
A-102

File details come from the government source that posted it. Updated .