This document provides details on a federal contract solicitation from the Department of the Air Force Reserve Command. Solicitation number FA6606-24-B-0001 seeks offers to repair the roof of Medical Facility B2235. Contractors can review the solicitation documents, including drawings of the facility, on SAM.gov. Any questions should be directed to the contracting officer, Amy Dumais. The solicitation appears to provide the necessary information for contractors to understand the required repair work and respond with pricing by the anticipated award date.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
439 CIVIL ENGINEER SQUADRON
WESTOVER ARB
250 AIRLIFT DR
CHICOPEE, MA 01022-1507
INDEX OF DRAWINGS
SHEET ID SHEET TITLE
G-001 COVER SHEET
YTPM 13-0011
REPAIR ROOF, BLDG 2235
WESTOVER AIR RESERVE BASE
CHICOPEE, MA
CONTRACT NO.: FA664318D0006
DELIVERY ORDER NO.: FA660622F0002
ISSUE DATE: JANUARY 2023
1105 LAKEWOOD PKY, STE 300
ALPHARETTA, GA 30009
R 1-
G -0
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
G -0
.D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
G-001
AD202
AD101 DEMOLITION ROOF PLAN
E-001 ELECTRICAL SYMBOLS LEGEND, GENERAL NOTES,AND ABBREVIATIONS
ED101 ELECTRICAL ROOF DEMOLITION PLAN
M-101 MECHANICAL NEW WORK ROOF PLAN
N.T.S.1 VICINITY MAP
EP101 ELECTRICAL ROOF POWER PLAN
C O
VE
R
S H
EE
T
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
AD201 DEMOLITION EXTERIOR ELEVATIONS (NORTH AND SOUTH)
MD101 MECHANICAL DEMOLITION ROOF PLAN
EL401 ELECTRICAL ENLARGED LIGHTING PLAN
S-101 STRUCTURAL ROOF PLAN
AS101 ARCHITECTURAL DEMO SITE PLAN
DEMOLITION EXTERIOR ELEVATIONS (EAST AND WEST)
AD301 DEMOLITION TOWER SIDE SECTION (NORTH AND SOUTH)
A-202
A-101 ARCHITECTURAL ROOF PLAN
A-201 EXTERIOR ELEVATIONS (NORTH AND SOUTH)
EXTERIOR ELEVATIONS (EAST AND WEST)
A-301 SECTION/ELEVATION (TOWER FEATURE)
RD101 ROOF DEMOLITION PLAN
S-301 SECTIONS AND DETAILS
PROJECT LOCATION
M-501 MECHANICAL DETAILS
G-002 ABBREVIATIONS SYMBOLS AND NOTES
AS102 ARCHITECTURAL SITE PLAN
R-101 ROOF PLAN
R-501 ROOF DETAILS
R-502 ROOF DETAILS
R-503 ROOF DETAILS
M-601 MECHANICAL SCHEDULES
AS501 ARCHITECTURAL SITE DETAILS
01/03/2023
R 1-
G -0
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
G -0
.D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE
OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED
OR INCOMPLETE CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE CORS ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
6. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND EXISTING CONDITIONS SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE COR IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
7. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE COR IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
8. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE APPLIED.
9. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING SHALL BE CONSTRUCTED AS DETAILED HEREIN.
10. DIMENSIONS SHOWN ARE TO FACE OF STUD OR CMU (U.O.N.).
11. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT MANUFACTURER'S STANDARDS.
12. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.
13. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES. ALL INTERIOR WALL AND CEILING FINISHES TO MEET FLAME SPREAD AND SMOKE DEVELOPMENT RATING IN ACCORDANCE TO ASTM E 84. ALL INTERIOR FLOOR FINISHES SHALL NOT BE LESS THAN CLASS II (0.22 WATTS/CM SQ.) FOR MINIMUM CRITICAL RADIANT FLUX IN
ACCORDANCE WITH NFPA 253.
14. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.
15. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON INDIVIDUAL
SHEETS SHALL BE APPLIED TO RELATED DRAWINGS AND DETAILS.
16. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL IS TO BE FINISHED OR FIRE-RATED AS INDICATED.
17. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE
DETERMINED, CONSULT THE COR BEFORE PROCEEDING WITH THE WORK.
18. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.
19. DO NOT CUT INTO, REMOVE OR ALTER ANY STRUCTURAL MEMBER OR PORTION OF THE ROOF STRUCTURE UNLESS IT IS SPECIFICALLY NOTED
OR SHOWN ON THE DRAWINGS.
20. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND PROPERTY THROUGHOUT THE EXECUTION OF THE PROJECT.
21. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE GOVERNMENT PRIOR TO START OF SUCH WORK.
22. ALL SIGNAGE TO BE APPROVED BY THE GOVERNMENT PRIOR TO ORDERING MATERIALS.
23. STORED MATERIALS SHALL BE KEPT DRY AND KEPT IN AN ORDERLY FASHION IN AN AREA DESIGNATED BY THE COR.
24. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR
TO CONSTRUCTION.
25. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC. TO ENSURE SAFETY TO THE PUBLIC.
26. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT,WHERE APPLICABLE ARE TO BE REPLACED ACCORDING TO STANDARDS OF THE MASSACHUSETTS DEPARTMENT OF TRANSPORTATION AND WESTOVER ARB, CHICOPEE, MA SPECIFICATIONS.
27. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH WESTOVER ARB, STATE, AND LOCAL ORDINANCES AND REGULATIONS. CONSTRUCTION
SHALL ALSO COMPLY WITH UFC CRITERIA.
28. COORDINATE WITH THE COR REGARDING EXISTING UTILITIES ON-SITE THAT ARE TO REMAIN INTACT. ADDITIONALLY, COORDINATE WITH THE COR REGARDING INTERRUPTIONS OF UTILITY SERVICE AND SCHEDULED SERVICE OUTAGES TO COMPLETE THE REQUIRED WORK.
29. DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REQUIREMENTS. DISPOSE OF HAZARDOUS WASTES IN
A MANNER CONSISTENT WITH APPLICABLE REQUIREMENTS.
30. CONTRACTOR RESPONSIBLE FOR ALL UTILITY LOCATION VERIFICATION PRIOR TO CONSTRUCTION.
31. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO WORK BEGINNING TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS
GENERAL NOTES STANDARD ABBREVIATIONS
A
A.C. AIR CONDITIONED
A.D. AREA DRAIN
A.F.F. ABOVE FINISH FLOOR
A.H.U. AIR HANDLING UNIT
ALT. ALTERNATE
ALUM. ALUMINUM
AMP.,A AMPERES
A.O. ACCESS OPENING
APPROX. APPROXIMATELY
ARCH. ARCHITECTURAL
A.T.C. ACOUSTICAL TILE CEILING
A.B. ANCHOR BOLT
BAL. BALANCE
BD. BOARD
BLDG. BUILDING
BLK. BLOCK
BM. BEAM
BOT. BOTTOM
BRG. BEARING
B.T.U.H. BRITISH THERMO UNIT/HR.
CAB. CABINET
CAP. CAPACITY
C/B CIRCUIT BREAKER
C.D. CEILING DIFFUSER
CEM. CEMENT
CER. CERAMIC
C.F.M. CUBIC FEET/MINUTE
CIRC. CIRCULATING
C.J. CONTROL JOINT
CK'D CHECKERED
CKT. CIRCUIT
C.L. CENTER LINE
CIEL.,CLG. CEILING
CLO. CLOSET
C.M.U. CONCRETE MASONRY UNIT
C.O. CLEAN OUT
COL. COLUMN
CONC. CONCRETE
COND.
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONT'R. CONTRACTOR
CONTR. JT. CONTRACTION JOINT
C.T. CERAMIC TILE
C.T.B. CERAMIC TILE BASE
C. TO C. CENTER TO CENTER
CU. FT.,CF. CUBIC FEET
DET. DETAIL
DIA. DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DISC. DISCONNECT
DN. DOWN
DR. DOOR
D.S. DOWNSPOUT
DWG. (S) DRAWING (S)
DSB DOUBLE STRENGTH "B" GLASS
EA. EACH
E.C. EMPTY CONDUIT
E.F. EXHAUST FAN
EL., ELEV. ELEVATION
ELEC. ELECTRIC
EQUIP. EQUIPMENT
E.W. EACH WAY
E.W.C. ELECTRIC WATER COOLER
EXH. EXHAUST
EXP. JT. EXPANSION JOINT
EXT. EXTERIOR
EXIST. EXISTING
F.A. FIRE ALARM
F.C. FLEXIBLE CONNECTION
F.D. FLOOR DRAIN
F.E.C. FIRE EXTINGUISHER CABINET
FIN. FINISH
FL. FLOOR
FT. FOOT - FEET
FTG. FOOTING
FDN. FOUNDATION
GA. GAGE
GAL. GALLON
GALV. GALVANIZED
G.F.E. GOVERNMENT FURNISHED EQUIPMENT
GL. GLASS
GND. GROUND
GOV'T GOVERNMENT
G.P.H. GALLONS/HOUR
G.P.M. GALLONS/MINUTE
GR. GRILLE
G.W.B. GYPSUM WALL BOARD
GYP. GYPSUM
H. HIGH
H.B. HOSE BIBB
H.C. HOLLOW CORE
HT. HEIGHT
H.M. HOLLOW METAL
H.P. HORSE POWER
HR. HOUR
HTG. HEATING
HTR. HEATER
HVAC HEATING, VENTILATION & AIR CONDITIONING
HW., HDWE. HARDWARE
HYD. HYDRANT
HORIZ. HORIZONTAL
I.D. INSIDE DIAMETER
I.E. INVERT
IN. INCHES
INCAND. INCANDESCENT
INSUL. INSULATION
INT. INTERIOR
J.B. JUNCTION BOX
JCT. JUNCTION
JT. JOINT
KVA KILOVOLT AMPERE
KW. KILOWATT
LB. POUND
LG. LONG
L.P. LIGHTING PANEL
LTG. LIGHTING
LAV. LAVATORY
M. MOTOR
MAINTENANCEMAINT.
MAX. MAXIMUM
M.D.P. MAIN DISTRIBUTION PANEL
MECH. MECHANICAL
MTL. METAL
MIN. MINIMUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
M.T. METAL THRESHOLD
MTD. MOUNTED
MTG. MOUNTING
M.V. MECHANICAL VENTILATION
N.A. NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NO., # NUMBER
O.A. OUTDOOR AIR
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.H. OVERHEAD
OL. OVERLOAD
OPNG. OPENING
OPP. OPPOSITE
O.S.D. OPEN SIGHT DRAIN
P. PAPER
PART'N. PARTITION
PER. PERIMETER
PL. PLATE
PLBG. PLUMBING
PLYD. PLYWOOD
PNL. PANEL
PRESS. PRESSURE
PSF POUNDS / SQUARE FOOT
PSI POUNDS / SQUARE INCH
PSIG POUNDS / SQUARE INCH GAGE
PT. POINT
PTD. PAINTED
P.T.D. PAPER TOWEL DISPENSER
QTR. QUARTER
QUAN. QUANTITY
R. RISER
R.A. RETURN AIR
RAD. RADIUS
RD. ROUND
REC'D. RECESSED
RECIRC. RECIRCULATING
RECP. RECEPTACLE
REG. REGISTER
REINF. REINFORCING
REQ'D. REQUIRED
RET. RETURN
R.G. RETURN GRILLE
RM. ROOM
S. SUPPLY
S.A. SUPPLY AIR
SCH. SCHEDULE
SECT. SECTION
SERV. SERVICE
SHT. SHEET
S.J. SLIP JOINT
SPEC. SPECIFICATIONS
SQ. FT., SF SQUARE FEET
STL. STEEL
STOR. STORAGE
STRUC. STRUCTURAL
SUSP. SUSPENDED
SW. SWITCH
STD. STANDARD
T., TOIL. TOILET
TEL. TELEPHONE
TEMP. TEMPERATURE
THK. THICKNESS
THD. THRESHOLD
TYP. TYPICAL
T.T.D. TOILET TISSUE DISPENSER
T.O.S. TOP OF STEEL
T & G TONGUE & GROOVE
TR. TREAD
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U.O.N. UNLESS OTHERWISE NOTED
V. VOLT
V.C.T. VINYL COMPOSITION TILE
VENT. VENTILATION
VERT. VERTICAL
VTR. VENT THRU ROOF
W
W. WATT
W/ WITH
WD. WOOD
W.G. WATER GAGE
WP. WEATHERPROOF
WTR. WATER
W.W.F. WELDED WIRE FABRIC
W.C. WATER CLOSET
W.H. WATER HEATER
U
V
A.C.M. ASBESTOS CONTAINING MATERIAL
R.P.M. REVOLUTIONS / MINUTE
R.O. ROUGH OPENING
FR. FRAME
CONDENSATE
FE FIRE EXTINGUISHER
STANDARD SYMBOLS
DETAIL NUMBER
SHEET DETAIL SHOWN ON
DETAIL NUMBER
SHEET DETAIL SHOWN ON
DETAIL NUMBER
SHEET DETAIL SHOWN ON
CONCRETE
SAND
GROUT
EARTH (COMPACTED)
EARTH (UNDISTURBED)
GRAVEL
CONCRETE / ASPHALT (NEW)
CMU (SECTION)
BRICK (SECTION)
CMU (PLAN)
STEEL
RIGID INSULATION
BATT INSULATION
BLOCKING
CMU (ELEVATION)
BRICK (ELEVATION)
GRATING
BOG. BOTTOM OF GRADE
G.F.G.I. GOVERNMENT FURNISHED
G.F.C.I. GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
CONTRACTOR INSTALLED
SPF SPRAY POLYURETHANE FOAM
SAFB SOUND ATTENUATING
FIBERGLASS BATTS
COR CONTRACTING OFFICERS
REPRESENTITIVE
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
G-002
AB
BR
EV
IA
TI
O
N S
SY
M
BO
LS
A N
D N
O
TE
S
SPRAY FOAM INSULATION
KEYED NOTE
NEW ROOF CONSTRUCTION
WRB. WATER RESISTIVE BARRIER
H
G3
G1
G
F
C
B
A3
A1
A
D
E
1 2 3 4 5 8 9
1 2 3 4 5 6B
H
G
6 7
G2
A2
6A
1A
B
D
F
E
A
C
19'-4" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 28'-0" 50'-0" 8'
-4
'-4
6'
-1 0"
1' -2
'-0
1' -2
"6' -1
0"
'-4
8' -4
'-4
19'-4" 19'-0" 19'-0" 19'-0" 27'-0"
18'-0"
'-4 " 23
'-6
'-6
6'
-1 0"
1' -2
'-0
1' -2
"6' -1
0"
1B
'-6
'-6
B1
F1
W
X1
4'-0"
4'-0"
W
X1
AREA OF
WORK
S-301
8'4'0 16'
SCALE: 1/8" = 1'-0"1 STRUCTURAL ROOF PLAN
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
S-
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
S-101
ST
R
U C
TU
R
AL
R
O O
F
PL
AN
M . L
AS
T
D . P
R
AT
T J.
B R
O W
N
STRUCTURAL GENERAL NOTES
1. STRUCTURAL DRAWINGS AND SPECIFICATIONS HAVE BEEN DEVELOPED IN
ACCORDANCE WITH THE CODE(S) LISTED BELOW.
2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
SPECIFICATIONS AND OTHER PROJECT DRAWINGS BY OTHER DISCIPLINES. ALL
WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CODES LISTED BELOW.
3. IN CASE OF CONFLICT BETWEEN THE NOTES, DETAILS AND SPECIFICATIONS, THE
MOST RIGID REQUIREMENTS SHALL GOVERN. CONTRACTOR SHALL MAKE NO
DEVIATION FROM CONTRACT DOCUMENTS WITHOUT WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
4. THESE CONTRACT DRAWINGS SHALL NOT BE SCALED FOR THE PURPOSE OF
ESTABLISHING CORRECT DIMENSIONS. THE CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS OR OBTAIN CORRECT DIMENSIONS FROM THE CONTRACTING
OFFICER.
DESIGN CODES AND SPECIFICATIONS
1. GENERAL BUILDING CODE:
1.1. INTERNATIONAL BUILDING CODE (IBC) 2018
1.2. INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018
1.3. AMERICAN SOCIETY OF CIVIL ENGINEERS: MINIMUM DESIGN LOADS AND
ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7)
1.4. UNIFIED FACILITIES CRITERIA 1-200-01 DOD BUILDING CODE (GENERAL
BUILDING REQUIREMENTS) W/ CHANGE 1, DATED OCT 1, 2020
1.5. UNIFIED FACILITIES CRITERIA 3-301-01 STRUCTURAL ENGINEERING W/
CHANGE 1 (UFC 3-301-01), DATED FEB 4, 2022
2. STRUCTURAL STEEL:
2.1. AMERICAN INSTITUTE OF STEEL CONSTRUCTION: SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS (AISC 360) 2016
3. STEEL DECK:
3.1. STEEL DECK INSTITUTE: STANDARD FOR COMPOSITE STEEL FLOOR DECK (SDI
C), 2017
3.2. STEEL DECK INSTITUTE: STANDARD FOR NON-COMPOSITE STEEL FLOOR
DECK (SDI NC), 2017
3.3. STEEL DECK INSTITUTE: STANDARD FOR STEEL ROOF DECK (SDI R), 2017
3.4. STEEL DECK INSTITUTE: CODE OF STANDARD PRACTICE (SDI COSP), 2017
4. COLD-FORMED STEEL:
4.1. NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS (AISI S100) 2016
DESIGN LOADS
1. ROOF LIVE LOADS
1.1. ROOF LIVE LOAD = 20 PSF
1.2. SNOW LOADS
1.3. GROUND SNOW LOAD, Pg = 35 PSF
1.4. FLAT ROOF SNOW LOAD, Pf = 22 PSF
1.5. BALANCED SLOPED ROOF SNOW LOAD = 22 PSF
1.6. UNBALANCED SLOPED ROOF SNOW LOAD = 40.2 PSF
1.7. SNOW EXPOSURE FACTOR, Ce = 0.9
1.8. SNOW LOAD IMPORTANCE FACTOR, Is = 1.0
1.9. THERMAL FACTOR, Ct = 1.0
2. WIND LOADS
2.1. ULTIMATE DESIGN WIND SPEED, Vult = 115
2.2. NOMINAL DESIGN WIND SPEED, Vasd = 89 PSF
2.3. RISK CATEGORY = II
2.4. WIND EXPOSURE CATEGORY = C
2.5. INTERNAL PRESSURE COEFFICIENT = ±0.18
2.6. MAIN WIND FORCE RESISTING SYSTEM PRESSURE = 25.8 PSF
2.7. COMPONENTS & CLADDING PRESSURE = PSF
3. SEISMIC LOADS
3.1. RISK CATEGORY = II
3.2. SEISMIC IMPORTANCE FACTOR, I/e = 1.0
3.3. Ss = 0168 g
3.4. S1 = 0.055 g
3.5. SEISMIC SITE CLASS = D
3.6. SDs = 0.179 g
3.7. SD1 = 0.089 g
3.8. SEISMIC DESIGN CATEGORY = B
3.9. BASIC SEISMIC FORCE-RESISTING SYSTEM = STEEL ORDINARY MOMENT
FRAME
3.10. SEISMIC RESPONSE COEFFICIENT, C/s = 0.0595
3.11. RESPONSE MODIFICATION COEFFICIENT, R = 3
STRUCTURAL STEEL
1. STRUCTURAL STEEL WORK SHALL CONFORM TO THE AISC "SPECIFICATIONS FOR
STRUCTURAL STEEL BUILDINGS".
2. ALL GROOVE WELDS SHALL BE FULL PENETRATION.
3. WHERE FILLET WELD SIZE IS NOT SHOWN , MINIMUM SIZE SHALL BE 316"
4. ALL WELDS SHALL BE SHOP WELDS TO THE EXTENT PRACTICABLE (TYPICAL
UNLESS OTHERWSIE SHOWN OR APPROVED).
5. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
WIDE FLANGE ASTM A992
CHANNELS, PLATES, BARS ASTM A36
HIGH STRENGTH BOLTS ASTM F3125, GRADE A325
WELDING AWS D1.1 E70XX
5.1. LIGHT GAGE STEEL PURLINS FOR ROOF CONSTRUCTION SHALL HAVE THE
FOLLOWING MINIMUM PROPERTIES: Z SHAPED, 8 INCH DEEP, GALVANIZED, 16
GAGE, FY=33 KSI, SX=1.63 IN3, SY=0.288 IN3, IY=0.873 IN4, FLANGE WIDTH = 2 12",
MAX. SPACING 2'-0"
PLAN
NORTH
TRUE
NORTH
3"
1'-8"
2'-0"
TYP.
57 16"
8" 1 26GA.
Z-PURLINS WELD
PURLIN WITHIN RIB
POCKET OF STEEL
DECK @ 18" O.C.
C8X11.5
T.O.S. 24'-7 1/16" W10X12
C8X11.5 RIDGE
PURLINS 5/8" BENT
ROD WITH NUTS
S-301
S-301
S-301
8" BOLTS, COUNTERSINK
ALL HEADS INTO WOOD,
TYP.
2X4 PT WOOD
NAILER, TYP.
X
X
1.5 B22 INVERTED
ROOF DECK
EXISTING ROOF
DECK
8" 16GA. Z PURLIN
WELDED TO
POCKET OF DECK
@ 16" O.C.
4'-0" C.-C.
8'-0" C.-C.
EXISTING ROOF
DECK
W10X12 TYP.
NOTES FOR STEEL ROOF DECK (DIAPHRAM)
WELD PURLIN WITHIN RIB POCKET OF
STEEL DECK TO W10X12. DO NOT WELD
ABOVE AND BELOW DECK AT THE SAME
LOCATION TO AVOID BLOW HOLES
3/4" THICK 40/20 APA RATED EXTERIOR EXPOSURE
PLYWOOD.PLYWOOD SHALL BE FASTENED TO PURLINS 6" ON
CENTER AT SUPPORTED PANEL EDGES, EAVES, CORNERS,
RIDGES, GABLE ENDS AS WELL AS INTERMEDIATE PANEL
SUPPORTS
X
X
4"
X
X
4"
X
X
4"
4"
CLR.13
4"
4"
CLR.
W10X12 TYP.
3/4" BOLTS TYP.
2"
TYP.
3/16" STIFFENER
PLATES
W10X12
3/16" STIFFENER
PLATE
BEAM C/L
2"
2"
4"
2"
2"
1' -1
4"
7"
2"
4"
2"
A
A 1
2" PLATE
2" M
AX
NEW C8X11.5
T.O.S. +/-24'-7 1/16"
W10X12NEW W10X12
ONE L6X4X1/2, EA
SIDE OF W10X12, 2
TOTAL PER BEAM
1A 3 3
28'-0" EXISTING
±9 '-4
"±1 5'
-0 "±2
3' -1
8"
±2 8'
-6 1 8"
EXIST.
W10X60
EXIST.
W10 X 49
EXIST.
W10 X 54
EXIST.
TS10 X 10X 1/2
EXIST. W10X12
EXIST. SHEAR
CONN.
EXIST. SHEAR
CONN.
EXIST. MOMENT
CONN.
4'-0" 4'-0" EXIST. W10X12
EXIST.
TS10 X 10X 1/2
NEW
W10X12 2
S-301
EXIST.
TS10 X 10X 1/2
AREA OF
WORK
KEYED NOTES
NEW ROOF DECK SHALL BE OVERLAPPED OR BUTTED WITH EXISTING
ROOF DECK. DO NOT TRIM DECK AROUND EXISTING PURLINS TO
OVERLAP. MIN 2" BEARING AT SUPPORTS
CONTRACTOR SHALL USE 16 GA. PREFABRICATED GALVANIZED PLATE
TO CONNECT NEW PURLINS TO EXISTING PURLINS OR OVERLAP NEW
PURLIN WITH EXISTING PURLINS, MIN 5 1/2" OVERLAP. MIN FASTENER
EDGE DISTANCE = 1" AT ENDS OF PURLINS. ALL OTHER DIMENSIONS AS
SHOWN.
8'4'0 16'
SCALE: 1/8" = 1'-0"1 SECTION VIEW - LOOKING NORTH
PROFESSIONAL SEAL
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
S-
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
S-301
SE
C
TI
O
N S
AN
D
D
ET
AI
LS
M . L
AS
T
D . P
R
AT
T J.
B R
O W
N
GENERAL NOTES
0 1' 2'6"
SCALE: 1"=1'-0"2 TYPICAL DECK DETAIL
0 1' 2'6"
SCALE: 1"=1'-0"3 TYPICAL DECK SECTION
0 1' 2'6"
SCALE: 1"=1'-0"5 DETAIL
0 1' 2'6"
SCALE: 1"=1'-0"4 DETAIL
A-A
NOTES FOR STEEL ROOF DECK (DIAPHRAGM)
1. PHYSICAL PROPERTIES:
MIN. THICKNESS .02395 IN. FY=33KSI. GALVANIZED 22 GAUGE.
2. ROOF DECK SHALL CONFORM TO THE "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS", 2020 (AISI), ANSI/SDI
SD-2022 STANDARD FOR STEEL DECK, 2022 (SDI.
3. ROOF DECK SHALL BE ATTACHED TO STEEL SUPPORTS WITH 3/4" DIAMETER PUDDLE WELDS @ 12" O.C. SIDE SEAMS TO BE BUTTON PUNCHED @ 4"O.C. OR 1 1/2" SEAM
WELDS @ 24" O.C.
4. 1 1/2" METAL DECK MUST BE INSTALLED AS AN INVERTED DECK. AN INVERTED DECK IS REQUIRED TO ACCOMMODATE Z-PURLIN PLACEMENT. DO NOT INVERT A STANDARD
METAL DECK. DECK IS SERVING AS A DIAPHRAM AND FIRE BARRIER.
5. CONTRACTOR IS RESPONSIBLE FOR THE FULL AND COMPLETE REMOVAL OF THE EXISTING SKYLIGHT BACK TO THE EXISTING STEEL STRUCTURE.
268.5
268.5
268.5
8.
4"
64 GPM
4"
61 GPM
12"
106 GPM
6"
92 GPM
6"
23 GPM
4"
60 GPM
4"
57 GPM
6"
71 GPM
12"
12"
692 GPM
12"
391 GPM
12"
780 GPM
4"
16 GPM
4"
22 GPM
4"
21 GPM
4"
17 GPM
6"
18 GPM
6"
23 GPM
6"
4 GPM
12"
326 GPM
6"
117 GPM
6"
14 GPM
CB1
CB6
CB2CB3
TO
STORM
SEWER
CB4CB5
DS01 DS02 DS03 DS04
DS06 DS07
DS08
DS09DS12DS13
DS14
DS15DS16DS17DS18
DS20
DS05
6"
56 GPM
6"
14 GPM
12"
359 GPM
12"
464 GPM
6"
128 GPM
12"
741 GPM
12"
867 GPM
12"
166 GPM
12"
1,033 GPM
12"
819 GPM
COND
COND COND
8"
ORNAMENTAL
20"
PINE
SF
SF
SF
SF
DS10DS11 4" 4" 4"
DS19
EC
O
EC
O
ECO
SF
SF
SF
SF
SF
SF
SF
SF
EX'G ELEVS
PER AS-BUILTS
T/G=267.50
IE 12"=262.44
EX'G ELEVS
PER AS-BUILTS
IE 12"=263
EX'G ELEVS
PER AS-BUILTS
T/G=266.15
IE 6"=266.50
IE 12"=260.00
EX'G ELEVS
PER AS-BUILTS
T/G=266.21
IE IN=259.39
IE OUT=259.29
EX'G ELEVS
PER AS-BUILTS
T/G=266.21
IE IN=259.02
IE OUT=258.92
IE 6"=262.21
EX'G ELEVS
PER AS-BUILTS
T/G=262.02
IE IN=258.10
IE OUT=258.00
EX'G ELEVS
PER AS-BUILTS
T/G=263.30
IE IN=257.35
IE OUT=257.25
EX'G ELEVS
PER AS-BUILTS
RIM=265.5
IE IN N=260.47
IE IN S=257.18
IE OUT=256.68
MH
EX'G ELEVS
PER AS-BUILTS
IE=263.14±
EX'G ELEVS
PER AS-BUILTS
IE=264.00±
31'-0"±
'-8
'-0
12'6'0 18'
SCALE: 3/32" = 1'-0"1 ARCHITECTURAL SITE DEMO PLAN
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AS
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AS101
AR
C
H
IT
EC
TU
R
AL
D
EM
O S
IT
E
PL
AN
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
LEGEND
KEYED NOTES
REMOVE ALL LANDSCAPING PLANTINGS THROUGHOUT MAIN
ENTRANCE AREA.
REMOVE APPROXIMATELY 1'-0" DEPTH OF BUILT-UP LANDSCAPE
SOIL FROM AREA. REGRADE TO MATCH CONTOURS SHOWN.
REMOVE EXISTING TREE. SEE PLAN FOR SPECIES AND CALIPER
SAWCUT AND DEMO PORTION OF EXISTING SIDEWALK AND/OR
ASPHALT PAVING FOR NEW STORM WATER PIPING.
SCOPE AND CLEAR ALL BELOW GRADE ROOF LEADER PIPING
FROM BUILDING TO NEAREST CATCH BASIN. PROVIDE
CONTRACTING OFFICER WITH REPORT OF BLOCKAGES, DAMAGE,
OR OTHER DETERIORATION OF THE EXISTING STORMWATER
SYSTEM.
DEMOLISH EXISTING DOWNSPOUT BOOT, PREPARE FOR NEW
CAST IRON BOOT.
REMOVE GRAVEL LANDSCAPING MATERIAL +/- 400SF x 6" DEEP.
REGRADE TO MATCH CONTOURS SHOWN.
INSTALL SILT FENCE (SEE DETAIL SHEET AS501).
INSTALL COMPOSITE FILTER SOCK (SEE DETAIL SHEET AS501).
CUT EX'G INTERIOR ROOF DRAIN AT FOOTING. PREPARE FOR
NEW CAP/PLUG.
GENERAL NOTES
2 1
SCALE: NTS2 ENTRY GOOGLE EARTH VIEW
PLAN
NORTH
TRUE
NORTH
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
AREA TO BE DEMOLISHED / SAWCUT
PIPING TO BE SCOPED/CLEARED/CATALOGED
LANDSCAPE AREA TO BE REMOVED AND
REGRADED
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
GRAVEL LANDSCAPING MATERIAL TO BE
REMOVED AND REGRADED
SF SILT FENCE
9 9 9 9
999999
COMPOSITE FILTER SOCK
CB# EX'G CATCH BASIN TO REMAIN
PIPING TO BE DEMOLISHED
EXISTING CONTOURS
EXISTING CLEANOUTEC
O
268.5
268.5
268.5
8.
12"
106 GPM
6"
92 GPM
6"
23 GPM
6"
71 GPM
12"
12"
692 GPM
12"
391 GPM
12"
780 GPM
4"
16 GPM
4"
22 GPM
4"
21 GPM
4"
17 GPM
6"
18 GPM
6"
23 GPM
6"
4 GPM
12"
326 GPM
6"
117 GPM
6"
14 GPM
CB1
CB6
CB2CB3
TO
STORM
SEWER
CB4CB5
DS01 DS02 DS03 DS04
DS06 DS07
DS08
DS09DS12DS13
DS14
DS15DS16DS17DS18
DS20
DS05
6"
56 GPM
6"
14 GPM
12"
359 GPM
12"
464 GPM
6"
128 GPM
12"
741 GPM
12"
867 GPM
12"
166 GPM
12"
1,033 GPM
12"
819 GPM
6"
60 GPM
6"
57 GPM
6" 11 G
PM
6"
61 GPM
COND
COND COND
SF
SF
SF
SF
DS10DS11 4" 4" 4"
DS19
30 LF
39 LF
6"
64 GPM
CB7
PROPOSED ELEVS
T/G 266.8
IE 12" IN=261.65
IE 12" OUT=261.60
IE 6" IN=262.60
IE SUMP=261.60
36 LF
30 LF
EC
O
EC
O
ECO
SF
SF
SF
SF
SF
SF
SF
SF
EX'G ELEVS
PER AS-BUILTS
T/G=267.50
IE 12"=262.44
EX'G ELEVS
PER AS-BUILTS
IE 12"=263
EX'G ELEVS
PER AS-BUILTS
T/G=266.15
IE 6"=266.50
IE 12"=260.00
EX'G ELEVS
PER AS-BUILTS
T/G=266.21
IE IN=259.39
IE OUT=259.29
EX'G ELEVS
PER AS-BUILTS
T/G=266.21
IE IN=259.02
IE OUT=258.92
IE 6"=262.21
EX'G ELEVS
PER AS-BUILTS
T/G=262.02
IE IN=258.10
IE OUT=258.00
EX'G ELEVS
PER AS-BUILTS
T/G=263.30
IE IN=257.35
IE OUT=257.25
EX'G ELEVS
PER AS-BUILTS
RIM=265.5
IE IN N=260.47
IE IN S=257.18
IE OUT=256.68
MH
PROPOSED
IE 6" IN=263.94
PROPOSED
IE =264.30
PROPOSED
IE =263.46
PROPOSED
IE =262.92
EX'G ELEVS
PER AS-BUILTS
IE=263.14±
PROPOSED
IE =264.33
PROPOSED
IE =264.19
EX'G ELEVS
PER AS-BUILTS
IE=264.00±
31'-0"±
'-8
'-0
'-0
'-4
20'-8"±
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AS
2.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AS102
AR
C
H
IT
EC
TU
R
AL
SI
TE
P
LA
N
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
LEGEND
KEYED NOTES
REFORM SWALE AND RESEED WITH ATHLETIC TURF MIX. ENSURE
BRICK WEEPS ARE NOT COVERED BY SOIL.
SLOPE FINISHED GRADE AWAY FROM BUILDING AND RESEED
WITH ATHLETIC TURF MIX. ENSURE WEEPS ARE NOT COVERED BY
SOIL.
EXTEND EXISTING STORMWATER LINE FOR NEW DOWNSPOUT
BOOT.
PROVIDE NEW CAST IRON DOWNSPOUT BOOT WITH CLEANOUT.
MATCH EX'G INVERT ELEVATIONS U.O.N.
BACKFILL EXCAVATIONS.
PATCH/REPAIR CONCRETE WHERE CUT FOR NEW DOWNSPOUT
CONNECTIONS TO EXISTING PIPING SYSTEM.
PROVIDE LOAM BACKFILL AT AREA WHERE LANDSCAPING STONE
WAS REMOVED, +/- 400 SF x 6" DEEP.
HAND TOOL DIGGING REQUIRED DUE TO PROXIMITY OF HVAC
EQUIPMENT.
INSTALL NEW CATCH BASIN (SEE DETAIL SHEET AS501).
PATCH/REPAIR ASPHALT WHERE CUT FOR NEW DOWNSPOUT
CONNECTIONS TO EXISTING PIPING SYSTEM.
CAP/PLUG END OF EX'G RAIN LEADER TO REMAIN BELOW GRADE.
6"± CONCRETE EDGE AT CONC SIDEWALK-TO-ASPHALT PARKING
LOT TRANSITION, MATCH EX'G PROFILE.
GENERAL NOTES
12'6'0 18'
SCALE: 3/32" = 1'-0"1 ARCHITECTURAL SITE PLAN
SCALE: NTS2 ENTRY GOOGLE EARTH VIEW
PLAN
NORTH
TRUE
NORTH
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. BASIS OF DESIGN: ATHLETIC TURF MIX
29.59% DEPUTY TALL FESCUE
29.37% BOREAL CREEPING RED FESCUE
19.68% IQ PERENNIAL RYEGRASS
9.89% BABE KENTUCKY BLUEGRASS
9.85% BLUE BONNET KENTUCKY BLUEGRASS
9. MATCH EXISTING PIPE DEPTHS UNLESS OTHERWISE NOTED.
AREA TO BE RESEEDED
CONCRETE PATCH/REPAIR
6 5
TYP.
TYP.
AREA TO RECEIVE LOAM AND BE RESEEDED
EX'G STORM PIPING TO REMAIN
NEW STORM PIPING
DESIG. SIZE MAT'L
DS01 4" CAST IRON
DS02 4" CAST IRON
DS03 4" CAST IRON
DS04 4" CAST IRON
DS05 6" CAST IRON
DS06 6" CAST IRON
DS07 6" CAST IRON
DS08 -- DISCHARGE @ GRADE
DS09 4" CAST IRON
DS10 4" CAST IRON
DS11 4" CAST IRON
DS12 6" CAST IRON
DS13 6" CAST IRON
DS14 6" CAST IRON
DS15 4" CAST IRON
DS16 4" CAST IRON
DS17 4" CAST IRON
DS18 4" CAST IRON
DS19 6" CAST IRON
DS20 6" CAST IRON
DOWNSPOUT BOOT SCHEDULE
CB# EX'G CATCH BASIN TO REMAIN
CB# NEW CATCH BASIN
SF SILT FENCE
COMPOSITE FILTER SOCK
ASPHALT PATCH/REPAIR
EX'G CONTOURS263
NEW CONTOURS263
EXISTING CLEANOUT
NEW CLEANOUT
EC
O
N C
O
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AS
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AS501
AR
C
H
IT
EC
TU
R
AL
SI
TE
D
ET
AI
LS
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
NOT TO SCALE2 SIDEWALK PATCHING DETAIL, TYP.
3500 PSI CONCRETE SIDEWALK
EXPANSION JOINT IN SIDEWALK TROWEL OR SAWCUT JOINT IN SIDEWALK
1/2" 1/8"R.
M
AT
C H
EX
IS
TI
N
G
1/ 4"
M
AT
C H
EX
IS
TI
N
G
1"1/8"
M
AT
C H
EX
IS
TI
N
G
X X X
X
WELDED WIRE FABRIC (6X6 - W2.9XW2.9)
NOTES:
1. CONSTRUCT SIDEWALKS TO MATCH EXISTING WIDTHS AND THICKNESSES OF THE
SIDEWALK WHICH WAS REMOVED. CONTRACTOR TO VERIFY EXISTING CONCRETE
DIMENSIONS.
2. PLACE A GROOVE JOINT 1" DEEP WITH 1/8" RADII IN THE CONCRETE SIDEWALK AT 5'
INTERVALS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT 50' INTERVALS AS
NECESSARY.
3. A 1/2" EXPANSION JOINT SHALL BE REQUIRED FOR SIDEWALKS ABUTTING A RIGID
STRUCTURE.
6" COMPACTED
GRAVEL
SUBGRADE TO
95% MODIFIED
PROCTOR
COMPACT CLEAN SPOILS TO 95% MODIFIED PROCTOR.
DEPTH OF COMPACTED CLEAN SPOILS SHALL BE
SUFFICIENT TO ALLOW FOR THE 6" COMPACTED GRAVEL
SUBGRADE AND SIDEWALK DEPTH TO MATCH THE
EXISTING ELEVATIONS OF THE EXISTING SIDEWALK.
NOT TO SCALE5 ASPHALT PATCHING DETAIL
EX. BASE
EX. PAVEMENT
TACK COAT VERTICAL SURFACE
BEFORE NEW CONSTRUCTION 1.00'
SA
W
C U
T
EX
. E
O P
REMOVE EX. PAVEMENT. NEW PAVEMENT
TO MATCH SAWCUT EDGE.
NEW BASE TO MATCH EXISTING
NEW PAVEMENT TO MATCH EXISTING
COMPACTED FILL TO
MATCH EXISTING
Materials:
(1) Silt fence material should be polypropylene, polyethylene or polyamide woven or nonwoven fabric. The fabric width should be 36 inches, with a minimum unit weight of 4.5 oz/yd, mullen burst strength exceeding 190 lb/in2, ultraviolet stability exceeding 70%, and minimum apparent opening size of U.S. Sieve No.
30.
(2)
(3)
Fence posts should be made of hot rolled steel, at least 4 feet long with Tee or Y-bar cross section, surface painted or galvanized, minimum nominal weight 1.25 lb/ft2, and Brindell hardness exceeding 140.
Woven wire backing to support the fabric should be galvanized 2” x 4” welded wire, 12 gauge minimum.
Installation:
(1) Steel posts, which support the silt fence, should be installed on a slight angle toward the anticipated runoff source. Post must be embedded a minimum of 1-foot deep and spaced not more than 8 feet on center. Where water concentrates, the maximum spacing should be 6 feet.
(2)
(3)
Lay out fencing down-slope of disturbed area, following the contour as closely as possible. The fence should be sited so that the maximum drainage area is ¼ acre/100 feet of fence.
The toe of the silt fence should be trenched in with a spade or mechanical trencher, so that the down-slope face of the trench is flat and perpendicular to the line of flow. Where fence cannot be trenched in (e.g., pavement or rock outcrop), weight fabric flap with 3 inches of pea gravel on uphill side to prevent flow from seeping under fence.
(4)
(5)
The trench must be a minimum of 6 inches deep and 6 inches wide to allow for the silt fence fabric to be laid in the ground and backfilled with compacted material.
Silt fence should be securely fastened to each steel support post or to woven wire, which is in turn attached to the steel fence post. There should be a 3-foot overlap, securely fastened where ends of fabric meet.
(6) Silt fence should be removed when the site is completely stabilized so as not to block or impede storm flow or drainage.
Common Trouble Points:
(1) Fence not installed along the contour causing water to concentrate and flow over the fence.
(2)
(3)
(4)
Fabric not seated securely to ground (runoff passing under fence)
Fence not installed perpendicular to flow line (runoff escaping around sides)
Fence treating too large an area, or excessive channel flow (runoff overtops or collapses fence)
Inspection and Maintenance Guidelines:
(1) Inspect all fencing weekly, and after any rainfall.
(2)
(3)
(4)
Remove sediment when buildup reaches 6 inches.
Replace any torn fabric or install a second line of fencing parallel to the torn section.
Replace or repair any sections crushed or collapsed in the course of construction activity. If a section of fence is obstructing vehicular access, consider relocating it to a spot where it will provide equal protection, but will not obstruct vehicles. A triangular filter dike may be preferable to a silt fence at common vehicle access points.
(5) When construction is complete, the sediment should be disposed of in a manner that will not cause additional siltation and the prior location of the silt fence should be revegetated. The fence itself should be disposed of in an approved landfill.
NOT TO SCALE6 SILT FENCE DETAIL
NOT TO SCALE4 STANDARD PIPE TRENCH WIDTH
NOT TO SCALE1 CATCH BASIN DETAIL
NOT TO SCALE7 COMPOISITE FILTER SOCK
AD301
AD301
AD201
A-201
AD202
AD202
AD301
AD301
OPPOPP
9'-0"±
'-3
6' -6
TY
P
1'-0"±
TYP.
8'4'0 16'
SCALE: 1/8" = 1'-0"1 DEMOLITION ROOF PLAN
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AD
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AD101
D
EM
O
LI
TI
O
N R
O O
F
PL
AN
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
LEGEND
KEYED NOTES
DEMO EXISTING SKYLIGHT IN ITS ENTIRETY, PREPARE FOR NEW
INFILL.
DEMO EXISTING TROUGH-STYLE INTERNALLY DRAINING
GUTTERS, PREPARE FOR NEW INFILL. SEE DETAIL 3/AD301 FOR
MORE INFORMATION.
GENERAL NOTES
AD301
PLAN
NORTH
TRUE
NORTH
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOF AND MECH DRAWINGS FOR ADDITIONAL ROOF
DEMOLITION SCOPE.
9. THE CONTRACTOR SHALL NOT DEMO/TEAR OFF MORE ROOFING
THAN CAN BE REPLACED IN A SINGLE WORKING DAY. THE ROOF
SHALL BE TEMP DRIED AT THE END OF EVERY WORKING DAY.
ROOFTOP EXHAUST FAN - EXISTING TO REMAIN
ROOFTOP EXHAUST FAN - TO BE DEMOLISHED
ROOFTOP EXHAUST HOOD- TO BE DEMOLISHED
EXISTING SIDEWALL EXHAUST FAN- TO BE
DEMOLISHED
EXISTING ROOF VENT CAP- TO BE DEMOLISHED
EXISTING FLASHING AT EXISTING INSULATED
PLUMBING VENT- TO BE DEMOLISHED
EXISTING CHIMNEY
EXISTING CONCRETE PARAPET CAP TO BE
REMOVED
123578910 6
0'-0"
10'-8"
14'-0"
23'-0"
25'-3"
6B
1 2 3 4 5 6B 7 8 9 10
0'-0"
+10'-8"
+14'-0"
+16'-0"
+25'-3"
+29'-0"
KEYED NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 DEMOLITION EXTERIOR ELEVATION - NORTH
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AD
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AD201
D
EM
O
LI
TI
O
N
EX
TE
R
IO
R
E
LE
VA
TI
O N
S (N
O R
TH
A
N D
S O
U
TH
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 DEMOLITION EXTERIOR ELEVATION - SOUTH
TYP.
TYP.
TYP.
TYP.
UON
DEMO EXISTING SKYLIGHT IN ITS ENTIRETY.
DEMO EXISTING OVERSIZED INTERNALLY DRAINING GUTTERS.
DEMO EXISTING EXHAUST FANS AND ROOF CURBS IN THEIR
ENTIRETY.. **WARNING, WHITE CAULKING/MASTIC AT EXHAUST
FANS IS AN ASBESTOS CONTAINING MATERIAL** REMOVE AND
DISPOSE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND
LOCAL REGULATIONS.
DEMO EXISTING CONCRETE PARAPET CAP.
DEMO EXISTING DOWNSPOUTS & GUTTERS
DEMO EXISTING EIFS & WRB.
REMOVE EXIST MECH EQPT AND STORE FOR REINSTALLATION.
DEMO ROOF CURBS IN THEIR ENTIRETY.
DEMO EXISTING DOWNSPOUT BOOTS.
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOF AND MECH DRAWINGS FOR ADDITIONAL ROOF
DEMOLITION SCOPE.
TYP.
LEGEND
ASPHALT SHINGLES &
UNDERLAYMENT TO BE REMOVED
A A2 B C D E F G H
+10'-8"
+14'-0"
+25'-3"
G2
AA2BCDEFGH
10'-8"
14'-0"
F
0'-0"
+25'-3"
KEYED NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 DEMOLITION EXTERIOR ELEVATION - EAST
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AD
2.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AD202
D
EM
O
LI
TI
O
N
EX
TE
R
IO
R
E
LE
VA
TI
O N
S (E
AS
T
AN
D
W
ES
T)
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"2 DEMOLITION EXTERIOR ELEVATION - WEST
2 2
2 2
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOF AND MECH DRAWINGS FOR ADDITIONAL ROOF
DEMOLITION SCOPE.
DEMO EXISTING SKYLIGHT IN ITS ENTIRETY.
DEMO EXISTING OVERSIZED INTERNALLY DRAINING GUTTERS.
DEMO EXISTING EXHAUST FANS AND ROOF CURBS IN THEIR
ENTIRETY.. **WARNING, WHITE CAULKING/MASTIC AT EXHAUST
FANS IS AN ASBESTOS CONTAINING MATERIAL** REMOVE AND
DISPOSE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND
LOCAL REGULATIONS.
DEMO EXISTING CONCRETE PARAPET CAP.
DEMO EXISTING DOWNSPOUTS & GUTTERS
DEMO EXISTING EIFS & WRB.
REMOVE EXIST MECH EQPT AND STORE FOR REINSTALLATION.
DEMO ROOF CURBS IN THEIR ENTIRETY.
DEMO EXISTING DOWNSPOUT BOOTS.
TYP.
UON
TYP.
UON
TYP.
UON
TYP.
UON
TYP.
UON
LEGEND
ASPHALT SHINGLES &
UNDERLAYMENT TO BE REMOVED
1 1B 3 4 5 6A
+10'-8"
+14'-0"
+16'-0"
+25'-3"
+29'-0"
G E D B
0'-0"
F C
+/-25'-3"
+/-29'-0"
DEMO ALUMINUM
LINING AND
UNDERLAYMENT
DRILL 2" DIA HOLES @
12" O.C. IN SIDE WALLS
& BOTTOM OF EX'G
TROUGH FOR VENT AIR
DEMO STRAINER,
PREPARE PIPE FOR
NEW PLUG
DEMO FINISH,
UNDERLAYMENT, AND
FLASHING.
DEMO ROOFING
ACCESSORIES &
SHINGLES
KEYED NOTES
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
AD
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
AD301
D
EM
O
LI
TI
O
N
TO
W
ER
S
ID
E
SE
C
TI
O N
N O
R
TH
A N
D S
O U
TH
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 DEMOLITION TOWER SIDE SECTION EAST AND WEST
LEGEND
DEMO EXISTING SKYLIGHT IN ITS ENTIRETY. **WARNING, BLACK
CAULKING/MASTIC AT SKYLIGHT IS AN ASBESTOS CONTAINING MATERIAL**
REMOVE AND DISPOSE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL
REGULATIONS.
DEMO EXISTING TROUGH-STYLE INTERNAL GUTTER AND MAKE READY FOR NEW
IN-FILL. CAP EXISTING ROOF LEADER. CUT 2"x6" VENT HOLES @ 16" O.C. FRONT
AND BACK. SEE DETAIL 3/AD301.
DEMO EXIST MECH EQPT . DEMO ROOF CURBS IN THEIR ENTIRETY. **WARNING,
WHITE CAULKING/MASTIC AT EXHAUST FANS IS AN ASBESTOS CONTAINING
MATERIAL** REMOVE AND DISPOSE IN ACCORDANCE WITH ALL FEDERAL, STATE,
AND LOCAL REGULATIONS.
DEMO EXISTING CONCRETE PARAPET CAP.
DEMO EXISTING DOWNSPOUTS & GUTTERS.
DEMO EXISTING EIFS & WRB.
REPLACE FLASHING, COUNTER FLASHING, AND SEALANTS AT EXISTING STACK.
REMOVE EXISTING SKYLIGHT AND MAKE READY FOR NEW IN-FILL.
DEMO EXISTING FLASHING, COUNTER FLASHING, VENTS, BAFFLES, AND
EXPANSION JOINT COVERS.
AD301
E.I.F.S. TO BE REMOVED
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOF AND MECH DRAWINGS FOR ADDITIONAL ROOF
DEMOLITION SCOPE.
ASPHALT SHINGLES &
UNDERLAYMENT TO BE REMOVED
0 4' 8' 12'
SCALE: 1/4" = 1'-0"2 DEMOLITION SECTION - NORTH AND SOUTH
0 1' 2'6"
SCALE: 1" = 1'-0"3 DETAIL- TROUGH GUTTER DEMO
AD301
AD301 OPP.
A-201
A-201
A-202
A-202
9'-0"±
'-3
6' -6
TY
P.
1'-5"±
TYP.
8'4'0 16'
SCALE: 1/8" = 1'-0"1 ROOF PLAN
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
A-
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
A-101
AR
C
H
IT
EC
TU
R
AL
R O
O F
PL
AN
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
LEGEND
KEYED NOTES
INFILL SKYLIGHT OPENING SIM TO EXISTING ROOF ASSEMBLY1
GENERAL NOTES
2 2
PLAN
NORTH
TRUE
NORTH
INFILL TROUGH-STYLE GUTTER, SEE DETAIL 4/A-301 FOR MORE
INFORMATION.
NEW MECH EQPT. ON NEW ROOF CURB WITH INTEGRAL CRICKET,
SEE MECH AND ROOFING DRAWINGS
NEW METAL COPING
A-301
A-301
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOFING AND MECH DRAWINGS FOR ADDITIONAL
SCOPE AND INSTALLATION DETAILS.
NEW EXHAUST FAN
NEW METAL PARAPET CAP
A-301
A-301
OPPOPP
2 & 3
A-301
5 NEW SIDE WALL MECH EQPT, SEE MECH PLANS
TYP
UON
TYP
UON
6 PROVIDE NEW CURB AT EXHAUST FAN TO BE REINSTALLED, SEE
MECH & ROOFING DRAWINGS
TYP
UON
TYP
UON
NEW SIDE WALL EXHAUST FAN
EXISTING CHIMNEY
NEW ROOF VENT
NEW FLASHING AT EX'G INSULATED PLUMBING VENT
123578910 6
10'-8"
14'-0"
23'-0"
25'-3"
6B
1 2 3 4 5 6B 7 8 9 10
0'-0"
+10'-8"
+14'-0"
+16'-0"
+25'-3"
+29'-0"
KEYED NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 EXTERIOR ELEVATION - NORTH
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
A-
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
A-201
EX
TE
R
IO
R E
LE
VA
TI
O
N S
(N O
R
TH
A N
D S
O U
TH
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - SOUTH
LEGEND
3 TYP.
5 TYP.
5 TYP.
3 TYP.
INFILL SKYLIGHT OPENING SIM TO EXISTING ROOF ASSEMBLY.
INFILL GUTTER OPENING SIM TO EXISTING ROOF ASSEMBLY.
MECH EQPT ON NEW ROOF CURB WITH CRICKET.
NEW METAL COPING.
NEW ALUM DOWNSPOUTS & GUTTERS
ASPHALT SHINGLES
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOFING AND MECH DRAWINGS FOR ADDITIONAL
SCOPE AND INSTALLATION DETAILS.
METAL PANELS
B.O.D. PAC-CLAD FLUSH WALL PANELS
A A2 B C D E F G H
+10'-8"
+14'-0"
+25'-3"
G2
AA2BCDEFGH
10'-8"
14'-0"
F
0'-0"
+25'-3"
KEYED NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 EXTERIOR ELEVATION - EAST
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
A-
2.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
A-202
EX
TE
R
IO
R E
LE
VA
TI
O
N S
(E
AS
T
AN
D W
ES
T)
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION - WEST
LEGEND
2 2
2 2
INFILL SKYLIGHT OPENING SIM TO EXISTING ROOF ASSEMBLY.
INFILL GUTTER OPENING SIM TO EXISTING ROOF ASSEMBLY.
REINSTALL MECH EQPT ON NEW ROOF CURB WITH CRICKET.
NEW METAL COPING.
NEW ALUM DOWNSPOUTS & GUTTERS
ASPHALT SHINGLES
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF
AREA OF WORK FROM DEMOLITION & CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL FOLLOW UFGS 02 82 00: ASBESTOS
REMEDIATION AND ALL FEDERAL, STATE, AND LOCAL
REGULATIONS FOR ASBESTOS WORK AND DISPOSAL.
3. ALL DIMENSIONS ARE TO FINISHED FACES. FIELD VERIFY ALL
DIMENSIONS PRIOR TO START OF WORK.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL FROM THE
SITE AND PROPER DISPOSAL OF ANY DEBRIS ACCUMULATED
DURING CONSTRUCTION ON A DAILY BASIS.
5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
6. STORED MATERIALS SHALL BE KEPT DRY AND IN AN ORDERLY
FASHION IN AN AREA DESIGNATED BY THE COR.
7. THE BUILDING WILL REMAIN OCCUPIED THROUGHOUT THE
EXECUTION OF THE WORK. ALL AREAS SHALL BE
WEATHER-TIGHT BETWEEN WORK PERIODS TO PREVENT LEAKS
DURING CONSTRUCTION.
8. REFER TO ROOFING AND MECH DRAWINGS FOR ADDITIONAL
SCOPE AND INSTALLATION DETAILS.
METAL PANELS
B.O.D. PAC-CLAD FLUSH WALL PANELS
1 1B 3 4 5 6A
+10'-8"
+14'-0"
+16'-0"
+25'-3"
+29'-0"
G E D B
0'-0"
F C
+/-25'-3"
+/-29'-0"
1' -7
'-7
2'-4"± 2'-4"±
'-0
TY
P.
NEW ASPHALT
SHINGLES OVER
UNDERLAYMENT
SEE TYPICAL GUTTER
AND DOWNSPOUT
DETAIL 10/R-503
CAP OR PLUG EXISTING
ROOF LEADER
3/4" EXT. SHEATHING
FASTENED TO EXISTING
BLOCKING
PROVIDE PT BLOCKING TO
ALIGN NEW ROOF SHTG
W/ EXIST ROOF SLOPE.
RAIN LEADER BOOT AND CLEAN OUT DETAIL
DOWNSPOUT
6" WYE CLEAN
OUT
TYPICAL MOUNTING DETAIL
2" AIR GAP
SEE DRAWINGS
EXISTING 4" OR 6"
STORM DRAIN
CAULDER COUPLING WITH STAINLESS
STEEL STRAPS AND INSERTS OR
STAINLESS STEEL NO HUB BAND TO
CONNECT TO EXISTING STORM PIPING
MOUNTING
STRAP
6" CAST IRON BOOT
DS20
DS19
+/- 28'-10 0"
+/- 8'-0"
+/- 8'-0"
20'-1"±
'-0
'-4
9'-0"±
3'-1"±
27'-9"
17'-0"±
KEYED NOTES
C O
N
TR
AC
T
N O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
D
2 3
C
4 5
A
B
M
AR
K
AP
PR
N
TP
D
N U
M
BE
R
SI
ZE
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
IS
SU
E D
AT
E:
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
EL
IV
ER
Y O
R D
ER
SHEET
IDENTIFICATION
D
AT
E
AP
PR
L
AK
EW
O
O D
P
KY
, S
TE
AL
PH
AR
ET
TA
, G
A
W oo d-
ZA
PA
TA
J V
CORRECTED FINAL - ISSUE FOR CONSTRUCTION
FA
D
FA
F0
JU
N
E
AN
SI
D
AS
N
O
TE
D
M . S
IL
VI
JA
N
A-
1.
D
W G
U .S
. A
IR
F O
R C
E R
ES
ER
VE
W es to ve r A R
B, C hi co pe e, M A
C O
M M
AN
D
YT
PM
3-
R
EP
AI
R
R O
O F, B
LD
G
W
ES
TO
VE
R A
R B, C H
IC
O
PE
E, M A
A-301
SE
C
TI
O
N /E
LE
VA
TI
O
N (T
O W
ER
F
EA
TU
R E)
M . S
IL
VI
D . P
R
AT
T R
. A
SH
E
GENERAL NOTES
8'4'0 16'
SCALE: 1/8" = 1'-0"1 SIDE SECTION - EAST AND WEST
LEGEND
NEW METAL COPING.
NEW ALUM DOWNSPOUTS & GUTTERS
NEW 2", R-15 MIN. INSULATED METAL PANEL SYSTEM ON GIRTS PER MFR OVER
NEW WRB ON EX'G WALL SHTG. B.O.D. METLSPAN CF.
NEW ASPHALT SHINGLE ROOF OVER 30# FELT ON 3/4" EXT PLYWOOD SHTG.
NEW GWB OVER PLYWOOD. PROVIDE METAL CORNER AND J-BEADS. PAINT TO
MATCH EXISTING SOFFITS.- FINISH ALL VISIBLE EDGES.
NEW SIDE WALL EXHAUST FAN,- SEE MECH. DWGS.
NEW GYPSUM BD CEILING ON 3 3/8" METAL STUDS @ 16"O.C. FLUSH WITH
ADJACENT CEILING. PAINT CLG IN THROUGHOUT ENTRY TO MATCH EX'G
NEW PENDANT LIGHT FIXTURE, SEE ELECT DRAWINGS.
PAINT EXISTING SOFFITS TO MATCH ADJACENT AREA.
PAINT WALLS ABOVE COVE LIGHTS IN THEIR ENTIRETY, COLOR TO MATCH EX'G
ASPHALT SHINGLES
INSULATED METAL PANELS,
B.O.D. METLSPAN CF
1. CONTRACTOR SHALL PROTECT ADJACENT AREAS OUTSIDE OF…