Attachment_11_ASHE_18-1025_Drawings_(Seed_project)_Part15_Part1.pdf
PDF 2 MB Posted
- Attached to
- Multiple Award Construction Contract (MACC) Italy Federal contract opportunity
- Solicitation number
- FA568219RA001
About this file
This document is a draft request for proposal for an indefinite delivery indefinite quantity multiple award construction contract for design-build construction services in Italy. The scope of work includes projects across multiple trades such as grading, utilities, painting, roofing, building construction, electrical work, HVAC, fire suppression, fuel systems, lighting, generators, communications, and site work. The contract period is one base year with four option years, with a minimum guaranteed amount of $2,500 and maximum aggregate value of $96 million. The minimum task order is $2,500 and maximum is $7 million. Interested parties are invited to submit comments on the draft documents by April 19, 2019. The solicitation will be issued through beta.SAM.gov, with an anticipated issuance date of May 2019. The contracting office is located at Aviano Air Base in Italy.
Attachment 11 ASHE 18-1025 Drawings (Seed Project) Part 15 Part 1
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC) Italy has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND OF SYMBOLS / LEGENDA SIMBOLI
PB.PV
PHOTOVOLTAIC SYS PANEL
QUADRO IMP. FOTOVOLTAICO
FU1
G
M2 kWh kvarh
Id
QF.PV
S.P.I.
I>>
OUT
8.50 kW
MPPT2MPPT1PE
INVERTER
OUT 400 V PE
MPPT1
MPPT2
INVERTER
P-PV
PV MODULE DETAIL - not to scale
PARTICOLARE MODULO FV - non in scala
400 V
AN
AN
st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
E-610
AutoCAD SHX Text
ATTENZIONE IMPIANTO IN TENSIONE DURANTE IL GIORNO
AutoCAD SHX Text STRING/STRINGA 1: 16x270= 4.32 kWp
AutoCAD SHX Text
AutoCAD SHX Text
MODULO FOTOVOLTAICO POLICRISTALLINO,
AutoCAD SHX Text 270 Wp, CON DIODO DI BYPASS
AutoCAD SHX Text
DIODO DI BLOCCO STRINGA
AutoCAD SHX Text
SURGE PROTECTION DEVICE
AutoCAD SHX Text FG16OR16 5G6 sq.mm FROM QE.PV DA QE.PV
AutoCAD SHX Text
LABEL TO BE APPLIED ON PANELBOARD ETICHETTA DA APPLICARE SUL QUADRO
AutoCAD SHX Text 3P+N/32A
AutoCAD SHX Text 10,3x38/1A gG
AutoCAD SHX Text
PILOT LAMPS
AutoCAD SHX Text
SPIE PRESENZA
AutoCAD SHX Text
FS17
AutoCAD SHX Text 4x1.5
AutoCAD SHX Text 0,5
AutoCAD SHX Text
BAR
AutoCAD SHX Text I
AutoCAD SHX Text r
AutoCAD SHX Text Thermal / Termico
AutoCAD SHX Text Calibro
AutoCAD SHX Text Formazione
AutoCAD SHX Text Lunghezza
AutoCAD SHX Text Tipo di Cavo
AutoCAD SHX Text Ground fault / Diff.
AutoCAD SHX Text Magnetic / Magnetica
AutoCAD SHX Text
POTENZA
AutoCAD SHX Text
LINEA DI
AutoCAD SHX Text
LINE / UTENZA
AutoCAD SHX Text
POWER / POTENZA
AutoCAD SHX Text mmq
AutoCAD SHX Text kW
AutoCAD SHX Text m
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text cu
AutoCAD SHX Text n
AutoCAD SHX Text N° Poli x Portata
AutoCAD SHX Text Interr. ampacity
AutoCAD SHX Text
INTERRUTTORE
AutoCAD SHX Text N° Poli x Portata
AutoCAD SHX Text
CIRCUIT / CIRCUITO
AutoCAD SHX Text Taratura
AutoCAD SHX Text Type / Tipo
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
PROTEZ. MOTORE
AutoCAD SHX Text
MOTOR PROTECT.
AutoCAD SHX Text
FUSIBILI
AutoCAD SHX Text
FUSES
AutoCAD SHX Text
CONTATTORE
AutoCAD SHX Text
CONTACTOR
AutoCAD SHX Text I
AutoCAD SHX Text m
AutoCAD SHX Text I
AutoCAD SHX Text dn
AutoCAD SHX Text I
AutoCAD SHX Text r
AutoCAD SHX Text Type / Tipo
AutoCAD SHX Text Type / Tipo
AutoCAD SHX Text I
AutoCAD SHX Text n
AutoCAD SHX Text
METALLIC. DOOR WITH KEY
AutoCAD SHX Text
METALLICO. PORTA CHIAVE
AutoCAD SHX Text Minimo 10 kA, IP4X
AutoCAD SHX Text Minimum 10 kA, IP4X
AutoCAD SHX Text
PILOT LAMPS
AutoCAD SHX Text Icn PH-N < 6 kA
AutoCAD SHX Text Icn 3PH < 10 kA
AutoCAD SHX Text
BREAKERS: CEI EN 60947-2
AutoCAD SHX Text
PANELBOARDS: CEI EN 61439-1/2
AutoCAD SHX Text
INTERRUTTORI: CEI EN 60947-2
AutoCAD SHX Text
QUADRI: CEI EN 61439-1/2
AutoCAD SHX Text
3 WHITE
AutoCAD SHX Text
TENSIONE
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
MDP - MAIN DISTRIBUTION BOARD
AutoCAD SHX Text
MDP - QUADRO ELETTRICO GENERALE
AutoCAD SHX Text
PRODUCED POWER METER CONTATORE ENERGIA PRODOTTA
AutoCAD SHX Text L1
AutoCAD SHX Text L3
AutoCAD SHX Text L2
AutoCAD SHX Text
LN
AutoCAD SHX Text 15 kA
AutoCAD SHX Text 3P+N
AutoCAD SHX Text 25A
AutoCAD SHX Text C
AutoCAD SHX Text
PB.PV
AutoCAD SHX Text
PB.PV
AutoCAD SHX Text
QUADRO FOTOVOLT.
AutoCAD SHX Text
PHOTOVOLT. PANEL
AutoCAD SHX Text 0.3A
AutoCAD SHX Text A
AutoCAD SHX Text
FG16OR16
AutoCAD SHX Text 5G4
AutoCAD SHX Text
AutoCAD SHX Text
PV
AutoCAD SHX Text 8,40 kWp
AutoCAD SHX Text TRIP COIL CONTROLLED BY THE PROTECTION SYS OF THE PV AND BY THE EMERGENCY PUSH-BUTTON BOBINA DI SGANCIO AZIONATA DAL SISTEMA DI PROTEZIONE FOTOVOLTAICO E DAL PULSANTE DI SGANCIO GENERALE
AutoCAD SHX Text
UPS 150VA
AutoCAD SHX Text 230V
AutoCAD SHX Text 230V
AutoCAD SHX Text
CEI 0-21
AutoCAD SHX Text
DDI
AutoCAD SHX Text
PROTECTION DEVICE
AutoCAD SHX Text
DISPOSITIVO DI
AutoCAD SHX Text
FG16OR16
AutoCAD SHX Text 5G6
AutoCAD SHX Text
AutoCAD SHX Text
DDI
AutoCAD SHX Text
PROTEZIONE
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text 10 kA
AutoCAD SHX Text 3P+N
AutoCAD SHX Text 16A
AutoCAD SHX Text C
AutoCAD SHX Text 8,64 kWp
AutoCAD SHX Text
PROTECTION SYS
AutoCAD SHX Text
SISTEMA DI
AutoCAD SHX Text
SPI
AutoCAD SHX Text
PROTEZ. INTERF.
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text 6 kA
AutoCAD SHX Text 1P+N
AutoCAD SHX Text 6A
AutoCAD SHX Text C
AutoCAD SHX Text
FG16OR16
AutoCAD SHX Text 3G1.5
AutoCAD SHX Text
AutoCAD SHX Text
FG16OR16
AutoCAD SHX Text 5G6
AutoCAD SHX Text
AutoCAD SHX Text
TO THE INVERTER
AutoCAD SHX Text
ALL'INVERTER
AutoCAD SHX Text INVERTER, WALL MOUNTED TYPE. INSTALLED NEAR THE PANELBOARD PB.PV INVERTER, A PARETE, INSTALLATO A LATO DEL QUADRO ELETTRICO PB.PV
AutoCAD SHX Text STRING #1: #16 PV MODULES 270Wp EA. = 4,32 kWp STRINGA N°1: N°16 MODULI FV 270Wp Ciascuno = 4,32 kWp
AutoCAD SHX Text STRING #2: #16 PV MODULES 270Wp EA. = 4,32 kWp STRINGA N°2: N°16 MODULI FV 270Wp Ciascuno = 4,32 kWp
AutoCAD SHX Text FG21M21 SOLAR CABLES TYPE, 2x(1x6) sq.mm CAVI SOLARI TIPO FG21M21, 2x1(1x6) mmq
AutoCAD SHX Text EMERGENCY SWITCH-OFF PUSH-BUTTON INSTALLED ON WALL OUTSIDE THE MAIN ELECTRICAL ROOM, CLEARLY LABELLED "PHOTOVOLTAIC SYSTEM" PULSANTE DI SGANCIO EMERGENZA POSTO A PARETE FUORI DAL LOCALE ELETTRICO, CHIARAMENTE ETICHETTATO "IMPIANTO FOTOVOLTAICO"
AutoCAD SHX Text
BSL
AutoCAD SHX Text
BSL
AutoCAD SHX Text ±990
AutoCAD SHX Text ±1660
AutoCAD SHX Text ±50
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text STRING/STRINGA 2: 16x270= 4.32 kWp
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text FG21M21 SOLAR CABLES TYPE 2x(1x6)+1G6 sq.mm CAVI SOLARI TIPO FG21M21 2x1(1x6)+1G6 mmq
AutoCAD SHX Text QE-FV.FIELD: STRINGS PROTECTION PANEL, LOCATED NEAR THE INVERTER QE-FV.CAMPO: QUADRO PROTEZIONE STRINGHE, POSTO ACCANTO ALL'INVERTER
AutoCAD SHX Text
DISCONNECTOR/ SEZIONATORE
AutoCAD SHX Text 2x32A
AutoCAD SHX Text
DIODES/DIODI
AutoCAD SHX Text SPD type 2 Imax=40 kA Inom=15kA
AutoCAD SHX Text FUSE/FUSIBILI 2x12A
AutoCAD SHX Text
AutoCAD SHX Text SPD type 2 Imax=40 kA Inom=15 kA
AutoCAD SHX Text 2x32A
AutoCAD SHX Text FS17 1x6 mmq
AutoCAD SHX Text
DIODES/DIODI
AutoCAD SHX Text
AutoCAD SHX Text FS17 1x6 mmq
AutoCAD SHX Text
GROUNDING BAR BARRA DI TERRA
AutoCAD SHX Text FS17 1x16 mmq TO MAIN GROUND BAR AL COLLETTORE PRINCIPALE DI TERRA
AutoCAD SHX Text
MGB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text FUSE/FUSIBILI 2x12A
AutoCAD SHX Text
DISCONNECTOR/ SEZIONATORE
AutoCAD SHX Text
ATTENTION VOLTAGE-ON DURING THE DAY
AutoCAD SHX Text 270 Wp, WITH BYPASS DIODE
AutoCAD SHX Text
POLYCHRISTALLINE PHOTOVOLTAIC MODULE,
AutoCAD SHX Text
STRING ARRESTER DIODE
AutoCAD SHX Text
FUSIBILE
AutoCAD SHX Text
FUSE
AutoCAD SHX Text
SCARICATORE DI SOVRATENSIONE
AutoCAD SHX Text 1000Vdc TYPE DISCONNECTOR
AutoCAD SHX Text SEZIONATORE 1000Vcc
AutoCAD SHX Text
DDC
AutoCAD SHX Text
ANALOGIC OUTPUT: CONNECTION TO DDC USCITA ANALOGICA: COLLEGAMENTO AL DDC
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
PANELBOARDS: ONELINE DIAGRAMS
AutoCAD SHX Text
QUADRI ELETTRICI: SCHEMI UNIFILARI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
F1C1
TW
A1
B1
S
V A1
S
V A1
S
V A1
S
V A1
S
V A1
S
V F1
S
A1
S
V
A1
S
V F1
S
F1 A2
S
A2
S
A1
S
V
S
V1
S1 1&2
V2 F1 V1
S S S S S S
A1 F1
A1
S S S
A1
S
A1
S S S S
C1 C1 C2
S
C2
S
C2
S
V1
SV1
V2
DIMMERABLE
FIXTURES
DIMMERABLE
FIXTURES
DIMMERABLE
FIXTURES
V2
A1
DIMMERABLE
FIXTURES
A1
A1 A1
DIMMERABLE
FIXTURES
V2
A2 A2 A2 A2
S
A2
S
A2
S
A2 C1 F1 F1
S
C2
S
C2
S
A2
H1
S
A1
S
A2
E st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
E-611
LIGHTING CONTROL SYSTEM /
A1
SISTEMA DI CONTROLLO DELL'ILLUMINAZIONE
AutoCAD SHX Text NOTE ABOUT DALI SYSTEM THE DALI STANDARD HAS BEEN CHOOSEN TO SELECT DIFFERENT ILLUMINANCE VALUES DEPENDING ON THE PRESENCE OF PERSONS AND THE DAILY TIME. ALSO HAS BEEN CHoOSEN TO SHARE THE PRESENCE SENSORS BETWEEN ELECTRIC AND DDC SYSTEMS, IN ORDER TO CONTROL LIGHTING AND HVAC SYSTEMS. THE DALI DEVICES MUST BE PROVIDED IN OFFICES, MEETING ROOM, CORRIDORS AS SHOWN IN THIS ONE-LINE DIAGRAM. SMALL ROOMS NOT CONTINUOSLY OCCUPIED AND WITHOUT WINDOWS, AS WC AND JANITOR, WILL HAVE ORDINARY DEVICES SINCE ONLY ON-OFF FUNCTIONS IS REQUIRED. THE LIGHTING IN THE MEETING AND THE RELAX ROOMS MUST BE DIMMERABLE, TO OFFER A MORE COMFORTABLE ATMOSPHERE, WHILE THE LIGHTING IN THE CORRIDORS MUST BE DIMMERABLE IN ORDER TO REALIZE THE FOLLOWING CONTROLS: - ACTIVITY TIME (PRESENCE OF PERSONS): NOMINAL ILLUMINANCE ACTIVITY TIME (PRESENCE OF PERSONS): NOMINAL ILLUMINANCE - AFTER 10 minutes OF INACTIVITY (NO PRESENCE DETECTED BY SENSORS IN THE CORRIDORS); THE ILLUMINANCE MUST BE DECREASE AT 20% AFTER 10 minutes OF INACTIVITY (NO PRESENCE DETECTED BY SENSORS IN THE CORRIDORS); THE ILLUMINANCE MUST BE DECREASE AT 20% OF THE NOMINAL ILLUMINANCE, IN ORDER TO SAVE ENERGY AND DON'T CREATE DARK AREAS BY SWITCHING-OFF THE LIGHTING - SWITCH-OFF THE LIGHTING IF THE SENSORS DON'T DETECT ANY PRESENCE OF PERSONS IN THE ROOMS AND IN THE CORRIDORS. SWITCH-OFF THE LIGHTING IF THE SENSORS DON'T DETECT ANY PRESENCE OF PERSONS IN THE ROOMS AND IN THE CORRIDORS. THE SENSORS WILL ALSO CONTROL THE HVAC SYSTEM, IN ORDER TO SWITCH-OFF THE AIR CONDITIONING IN A SPECIFIC ROOM IF NO PRESENCE IS DETECTED BY THE ROOM SENSOR. THE SIGNALS OF THE SENSORS MUST BE TRASMITTED TO THE DDC, THAT CONTROLS THE HVAC SYSTEM, THROUGH A GATEWAY DALI-BACNet. NOTA SULL'IMPIANTO DALI LO STANDARD DALI E' STATO SCELTO PER SELEZIONARE DIFFERENTI VALORI DI ILLUMINAMENTO IN RELAZIONE ALLA PRESENZA DI PERSONE ED ALL'ORARIO GIORNALIERO. INOLTRE E' STATO SCELTO PER CONDIVIDERE I SENSORI DI PRESENZA TRA IL SISTEMA ELETTRICO E QUELLO DDC, PER CONTROLLARE GLI IMPIANTI DI ILLUMINAZIONE E DI CLIMATIZZAZIONE. I DISPOSITIVI DALI SONO DA FORNIRE NEGLI UFFICI, NELLA SALA MEETING E NELLA SALA RELAX, NEI CORRIDOI, COME MOSTRATO NELLO SCHEMA UNIFILARE. I LOCALI NON CONTINUAMENTE OCCUPATI E SENZA FINESTRE, QUALI WC, SMALTITOIO, AVRANNO DISPOSITIVI NORMALI PERCHE' E' RICHIESTA SOLO LA FUNZIONE ON-OFF. LA LUCE NELLE SALE MEETING E RELAX DOVRANNO ESSERE DIMMERABILI, PER OFFRIRE UN'ATMOSFERA PIU' CONFORTEVOLE, MENTRE L'ILLUMINAZIONE NEI CORRIDOI DOVRA' ESSERE DIMMERABILE PER REALIZZARE I SEGUENTI CONTROLLI: - ORARIO DI ATTIVITA' (PRESENZA DI PERSONE): ILLUMINAMENTO NOMINALE ORARIO DI ATTIVITA' (PRESENZA DI PERSONE): ILLUMINAMENTO NOMINALE - DOPO 10 minuti DI INATTIVITA' (NESSUNA RILEVAZIONE DI PRESENZA DA PARTE DEI SENSORI NEI CORRIDOI): L'ILLUMINAMENTO DOVRA' ESSERE DOPO 10 minuti DI INATTIVITA' (NESSUNA RILEVAZIONE DI PRESENZA DA PARTE DEI SENSORI NEI CORRIDOI): L'ILLUMINAMENTO DOVRA' ESSERE RIDOTTO AL 20% DEL VALORE NOMINALE, AL FINE DI RISPARMIARE ENERGIA E NON CREARE ZONE BUIE SPEGNENDO LA LUCE - SPEGNERE LA LUCE SE I SENSORI NON RILEVANO ALCUNA PRESENZA DI PERSONE NEI LOCALI E NEI CORRIDOI. SPEGNERE LA LUCE SE I SENSORI NON RILEVANO ALCUNA PRESENZA DI PERSONE NEI LOCALI E NEI CORRIDOI. I SENSORI INOLTRE CONTROLLERANNO IL SISTEMA DI CLIMATIZZAZIONE, AL FINE DI SPEGNERLO NEI LOCALI IN CUI I SENSORI DI PRESENZA NON RILEVANO ALCUNA PRESENZA DI PERSONE. I SEGNALI DEI SENSORI DOVRANNO ESSERE TRASFERITI AL DDC, CHE CONTROLA IL SISTEMA DI CLIMATIZZAZIONE, TRAMITE UN PORTALE DALI-BACNet.
AutoCAD SHX Text DALI CIRCUIT #1: CABLE 2x1.5 sq.mm CIRCUITO DALI N°1: CAVO 2x1.5 mmq
AutoCAD SHX Text
ROOM 02
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
RM 01
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 03
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 04
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 05
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 06
AutoCAD SHX Text
AHU #1
AutoCAD SHX Text
ROOM 07
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 08
AutoCAD SHX Text
SCIF
AutoCAD SHX Text
ROOM 09
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 10
AutoCAD SHX Text
ARMORY
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 11
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
#4 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
#°4 MANUAL
AutoCAD SHX Text
PUSH-BUTTONS
AutoCAD SHX Text
ROOM 13
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#1 INPUT
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 16
AutoCAD SHX Text
COMM.
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 12
AutoCAD SHX Text
BOILER
AutoCAD SHX Text
WP
AutoCAD SHX Text
ROOM 14
AutoCAD SHX Text
WC
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 15
AutoCAD SHX Text
WC
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 17
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
ROOM 18
AutoCAD SHX Text
MEETING ROOM
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
KNX
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
KNX
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
ROOM 19
AutoCAD SHX Text
ELECTR.
AutoCAD SHX Text
ROOM 20
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ROOM 21
AutoCAD SHX Text
SPRINKLER
AutoCAD SHX Text
WP
AutoCAD SHX Text
ORDINARY DEVICES: NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
#1 CHANNEL
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text controlled by sensors
AutoCAD SHX Text installed in room #20
AutoCAD SHX Text
ROOM 22
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ROOM 23
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ROOM 24
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ROOM 25
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text
ROOM 25.1
AutoCAD SHX Text
WC AND SHOWERS
AutoCAD SHX Text
PRESENCE
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 26
AutoCAD SHX Text
RELAX
AutoCAD SHX Text
#2 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL
AutoCAD SHX Text
PUSH-BUTTON
AutoCAD SHX Text
VACANCY
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
MANUAL-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ROOM 27
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
ROOM 28
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ROOM 29
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ROOM 30
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
ROOM 31
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ROOM 32
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
RM 33
AutoCAD SHX Text
PORCH
AutoCAD SHX Text
#1 CHANNEL
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text controlled by sensors
AutoCAD SHX Text installed in room #23
AutoCAD SHX Text
ROOM 34
AutoCAD SHX Text
AHU #2
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
ROOM 35
AutoCAD SHX Text
ELECTR.
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
ROOM 36
AutoCAD SHX Text
WC
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
ROOM 37
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
AUTOM.-ON
AutoCAD SHX Text
AUTOM.-OFF
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text
#1 CHANNEL
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
#1 CHANNEL
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
EXTERIOR LIGHTING: CONTROLLED
AutoCAD SHX Text
BY TWILIGHT AND TIME SWITCHES
AutoCAD SHX Text
GATEWAY
AutoCAD SHX Text DALI to BACNet
AutoCAD SHX Text
PORTALE DA
AutoCAD SHX Text DALI a BACNet
AutoCAD SHX Text
LOCATED IN
AutoCAD SHX Text
ROOM #35
AutoCAD SHX Text
POSTO NEL
AutoCAD SHX Text
LOCALE N°35
AutoCAD SHX Text
DDC
AutoCAD SHX Text
CONTROLLER
AutoCAD SHX Text
REGOLATORE
AutoCAD SHX Text
DDC
AutoCAD SHX Text
LOCATED IN
AutoCAD SHX Text
ROOM #34
AutoCAD SHX Text
POSTO NEL
AutoCAD SHX Text
LOCALE N°34
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text DALI CIRCUIT #2: CABLE 2x1.5 sq.mm CIRCUITO DALI N°2: CAVO 2x1.5 mmq
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text 6 amps
AutoCAD SHX Text 6 amps
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text
ROUTER
AutoCAD SHX Text
DALI
AutoCAD SHX Text DALI CIRCUIT #3: CABLE 2x1.5 sq.mm CIRCUITO DALI N°3: CAVO 2x1.5 mmq
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
SLAVE
AutoCAD SHX Text
SLAVE
AutoCAD SHX Text
SLAVE
AutoCAD SHX Text
MASTER
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
DALI FIXTURES
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
ON-OFF
AutoCAD SHX Text
AUTOMATIC-ON
AutoCAD SHX Text
AUTOMATIC-OFF
AutoCAD SHX Text
NO DALI
AutoCAD SHX Text
#4 INPUTS
AutoCAD SHX Text
INTERFACE
AutoCAD SHX Text
#°3 MANUAL
AutoCAD SHX Text
PUSH-BUTTONS
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
SCENARIO
AutoCAD SHX Text
SCENARIO
AutoCAD SHX Text 6 amps
AutoCAD SHX Text
#1 CHANNEL
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
VPJ
AutoCAD SHX Text
VIDEOPROJECTOR
AutoCAD SHX Text
CURTAIN
AutoCAD SHX Text NOTE ABOUT SCENARIOS IN THE RECEPTION AND THE MEETING ROOMS ARE PROVIDED #2 SCENARIOS PUSH-BUTTONS, EACH COMPOSED OF #3 PUSH-BUTTONS THAT HAVE THE FOLLOWING FUNCTIONS: RECEPTION 1: ON-OFF OF ALL THE LIGHTING CONNECTED TO THE DALI SYSTEM RECEPTION 2: REDUCING AT 20% OF NOMINAL ILLUMINANCE LEVEL THE CORRIDORS LIGHTING RECEPTION 3: ON-OFF OF EXTERIOR LIGHTING MEETING ROOM 1: REDUCING THE LIGHTING AT 5% OF THE NOMINAL ILLUMINANCE, DURING A VIDEO PROJECTION, COMBINED WITH THE AUTOMATIC MOVEMENT OF THE CURTAIN AT WALL MEETING ROOM 2: REDUCING THE LIGHTING AT 50% OF THE NOMINAL ILLUMINANCE MEETING ROOM 3: SPARE. NOTA SUGLI SCENARI IN RECEPTION E IN SALA MEETING SONO PREVISTE N°2 PULSANTIERE DI SCENARIO, OGNUNA CON N°3 PULSANTI CHE HANNO LE SEGUENTI FUNZIONI: RECEPTION 1: ON-OFF DI TUTTE LE LUCI CONNESSE AL SISTEMA DALI RECEPTION 2: RIDUZIONE FLUSSO LUMINOSO NOMINALE AL 20%, DELLE LAMPADE CORRIDOI RECEPTION 3: ON-OFF LUCI ESTERNE SALA MEETING 1: RIDUZIONE FLUSSO LUMINOSO NOMINALE AL 5%, DURANTE VIDEOPROIEZIONI. COMBINATO CON LA DISCESA AUTOMATICA DELLO SCHERMA DI VIDEPROIEZIONE. SALA MEETING 2: RIDUZIONE FLUSSO LUMINOSO NOMINALE AL 50%. SALA MEETING 3: RISERVA
AutoCAD SHX Text PRIMARY POWER LINE 230Vac
AutoCAD SHX Text Un=230/400V
AutoCAD SHX Text Uc=335V
AutoCAD SHX Text Class = II
AutoCAD SHX Text Iimp(10/350)=3kA
AutoCAD SHX Text In(8/20)=20kA
AutoCAD SHX Text Imax(8/20)=40kA
AutoCAD SHX Text Up(20kA)=1,55kA
AutoCAD SHX Text
SPD
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
LIGHTING CONTROLS: ONE-LINE DIAGRAM
AutoCAD SHX Text
CONTROLLI ILLUMINAZIONE: SCHEMA UNIFILARE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text
T-
1 HH
TELECOMMUNICATION SYSTEM LEGEND
LEGENDA IMPIANTO TELECOMUNICAZIONI
MH
TR
FB
TELECOMMUNICATION SYS.: EXTERIOR UTILITIES
IMP. TELECOMUNICAZIONI: SOTTOSERVIZI ESTERNI
EI 120
NOTES / NOTE
AS BUILT DRAWINGS AND FINAL DOCUMENTS
DISEGNI E DOCUMENTI FINALI
DOCUMENTATION IN CVC FORMAT
DOCUMENTAZIONE IN FORMATO CVC
COMMUNICATION CONTAINER ATTRIBUTION WORKSHEET - MANHOLE BUTTERFLY
COMMUNICATION CONTAINER ATTRIBUTION WORKSHEET - BUILDING ENTRANCE
LABELLING / ETICHETTATURA
st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
T-001
AutoCAD SHX Text
HH = HANDHOLE HH = POZZETTO
AutoCAD SHX Text UNDERGROUND DUCTS, INTERNAL SMOOTH-WALLED TYPE, min. SCHEDULE 40. PLACE min. 4 ea 1" SEMI-RIGID INNERDUCTS IN A A 4" (110 mm) CONDUIT. TUBAZIONE INTERRATA PVC RIGIDO, PARETI INTERNE LISCE, SPESSORE min. SCHEDULE 40. INSERIRE min. N°4 TUBI 25 mm SEMI-RIGIDI IN UN TUBO DI DIAMETRO 110 mm.
AutoCAD SHX Text GALVANIZED CABLE TRAY WITH COVER, IP4X. BONDED TO GROUND. INSTALLED ABOVE FALSE CEILING. SIZES AS SHOWN ON DRAWINGS CANALE IN ACCIAIO ZINCATO CON COPERCHIO, IP4X. COLLEGATO A TERRA. INSTALLATO SOPRA IL CONTROSOFFITTO. DIMENSIONI IN DISEGNO
AutoCAD SHX Text
MH = MANHOLE MH = CAMERETTA CAVI
AutoCAD SHX Text DATA CABINET, 42U TYPE, 80x100 cm. BOLTED TO FLOOR. EQUIPPED WITH: THERMOSTAT CONTROLLED VENTILATION SYSTEM (#2 VENTILATORS) #2 EACH, #8 EIGHT (8) RECEPTACLE POWER STRIPS WITHOUT SWTICHES (RECEPTACLES FACING TOWARDS THE MIDDLE - NOT TOWARDS THE FRONT) VERTICALLY GROUNDING BAR 14W FLUORESCENT LIGHT OR EQUIVALENT LED TYPE (1350 lm minimum) CONVENIENCE OUTLETS LATERAL CABLE MANAGEMENT SEE THE ENLARGEMENT PLAN ON SHEET E-401 FOR CABINETS LOCATION ARMADIO DATI 42 UNITA', 80x100 cm. IMBULLONATO A PAVIMENTO. COMPLETO DI: VENTILAZIONE CONTROLLATA DA TERMOSTATO (N°2 VENTILATORI) N°2 BLOCCHI PRESE, CIASCUNA CON N°8 PRESE, SENZA INTERRUTTORE (ORIENTATE VERSO LA META' ARMADIO, NON CHE GUARDANO IL SUO FRONTE) BARRA DI TERRA VERTICALE LAMPADA FLUORESCENTE 14W OD EQUIVALENTE LED (minimo 1350 lm) PRESE DI SERVIZIO GUIDE CAVI LATERALI VEDERE LA PIANTA INGRANDITA NEL FOGLIO E-401 PER LA POSIZIONE DEI RACK
AutoCAD SHX Text #2 OUTLETS RJ45, CAT 6, UTP TYPE, CONTAINED IN A SINGLE 4-POSITION FACEPLATE. TWO OPENINGS SHALL BE BLANKED-OFF FOR FUTURE USE. MOUNTED AT 0.45 m A.F.F. IF NOT OTHERWISE INDICATED. NOTE THAT THE STANDARD TIA 568B WIRING CONFIGURATION LIMITS TO DUAL OUTLETS THE INSTALLATION IN A 4-POSITION DROP. N.2 PRESE RJ45, CAT 6, TIPO UTP, IN SCATOLA 4 MODULI, DUE DEI QUALI CIECHI PREDISPOSTI PER UN FUTURO UTILIZZO. MONTATE A 0.45 m DAL PAVIMENTO FINITO SE NON DIVERSAMENTE INDICATO. NOTARE CHE IL CABLAGGIO IN CONFIGURAZIONE TIA 568B LIMITA A DUE LE PRESE INSTALLABILI IN UNA SCATOLA A 4 POSIZIONI.
AutoCAD SHX Text D
AutoCAD SHX Text
VPJ
AutoCAD SHX Text #1 VIDEOPROJECTOR RECEPTACLE, CONTAINED IN A SINGLE 3-POSITION FACEPLATE. TWO OPENINGS SHALL BE BLANKED-OFF FOR FUTURE USE (max #1 OTHER OUTLET). MOUNTED AT 0.45 m A.F.F. IF NOT OTHERWISE INDICATED N.1 PRESA VIDEOPROIETTORE, IN SCATOLA 3 MODULI, DUE DEI QUALI CIECHI PREDISPOSTI PER UN FUTURO UTILIZZO (max N.1 ALTRA PRESA). MONTATA A 0.45 m DAL PAVIMENTO FINITO SE NON DIVERSAMENTE INDICATO
AutoCAD SHX Text EXPOSED ON WALL BOX TYPE, PROTECTION DEGREE min. IP40 SCATOLA INSTALLATA A VISTA A PARETE, GRADO PROTEZIONE min. IP40
AutoCAD SHX Text EXPOSED ON WALL BOX, WEATHER PROOF TYPE, PROTECTION DEGREE min. IP55 SCATOLA INSTALLATA A VISTA A PARETE, ADATTA PER USO ESTERNO, min. IP55
AutoCAD SHX Text
WP
AutoCAD SHX Text #2 DATA OUTLETS RJ45, CAT 6, UTP TYPE, IN A RECESSED-FLOOR MOUNTED BOX N.2 PRESE RJ45, CAT 6, TIPO UTP, IN SCATOLA INCASSATA A PAVIMENTO
AutoCAD SHX Text
JUNCTION BOX - PULL BOX SCATOLA DI DERIVAZIONE - INFILAGGIO
AutoCAD SHX Text
UP AND DOWN RISERS DORSALI VERTICALI
AutoCAD SHX Text J
AutoCAD SHX Text CHANGE OF THE HEIGHT OF PATHWAY OF A CABLETRAY, TO PROVIDE IN THE EXISTING PART OF THE FACILITY TO LOCATE CABLETRAY BETWEEN THE BEAMS, TO REDUCE THE INTERFERENCES WITH WATER AND OTHER SYSTEMS PIPES CAMBIO DI ALTEZZA DEL PERCORSO DI UN CANALE, PREVISTO NELLA PARTE ESISTENTE DELL'EDIFICIO PER POSIZIONARE IL CANALE TRA LE TRAVI, AL FINE DI RIDURRE L'INTERFERENZA CON LE TUBAZIONI DEGLI ALTRI IMPIANTI
AutoCAD SHX Text FIRE RATED WALL PENETRATION, TO BE SEALED BY "EI 120" CERTIFIED PRODUCT. A DECLARATION OF CORRECT INSTALLATION MUST BE ISSUED AT THE END OF THE WORK, WITH A PLAN THAT SHOWS THE LOCATIONS OF EACH SEALING. PENETRAZIONE DI PARETE TAGLIAFUOCO, DA SIGILLARE CON PRODOTTO OMOLOGATO "EI 120". A FINE LAVORI DEV'ESSERE EMESSA DICHIARAZIONE DI CORRETTA POSA IN OPERA, ACCOMPAGNATA DA UNA PIANTA CHE ILLUSTRA LA POSIZIONE DELLE SIGILLATURE
AutoCAD SHX Text WALL, FLOOR OR CEILING PENETRATION, TO BE SEALED. HOLES THROUGH A WALL OR A CEILING (ROOF) EXPOSED TO THE EXTERIOR AREA MUST BE SEALED TO AVOID PENETRATION OF MOISTURE, INSECTS, RAIN. ATTRAVERSAMENTI DI PARETI, PAVIMENTO, SOFFITTO, DA SIGILLARE. I FORI ATTRAVERSO PARETI E SOFFITTO (TETTO) ESPOSTI VERSO L'ESTERNO DEVONO ESSERE SIGILLATI PER IMPEDIRE L'INGRESSO DI UMIDITA', INSETTI, PIOGGIA
AutoCAD SHX Text THE GROUND RESISTANCE AT THE MTGB MUST BE MAXIMUM 3.5 ohm LA RESISTENZA DI TERRA SUL COLLETTORE MTGB DEV'ESSERE MASSIMO 3.5 ohm
AutoCAD SHX Text THE TEMPERATURE INSIDE TELECOMMUNICATION ROOM MUST BE MAINTAIN AT 22° C LA TEMPERATURA NEL LOCALE TELECOMUNICAZIONI DEV'ESSERE MANTENUTO A 22°C
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text FIBER OPTIC CABLE MUST BE TERMINATED AT BOTH ENDS WITH SC CONNECTORS I CAVI OTTICI DEVONO ESSERE TERMINATI ALLE ESTREMITA' CON CONNNETTORI SC
AutoCAD SHX Text 3.
AutoCAD SHX Text FIRE RETARDANT 3/4" (20 mm) PLYWOOD BOARD ON WALLS PANNELLO IN LEGNO 20 mm, TRATTATO CON VERNICE NON PROPAGANTE LA FIAMMA. FISSATO A PARETE
AutoCAD SHX Text TELECOMMUNICATION CABLETRAYS MUST HAVE A SEPARATION OF 30 cm FROM POWER CABLETRAYS, WHILE BRANCH PATHWAYS MUST HAVE A SEPARATION OF 15 cm FROM BRANCH PATHWAYS OF POWER LINES. TELECOMMUNICATION RECEPTACLES MUST BE LOCATED 15 cm (NOT MORE, NOT LESS) AWAY FROM POWER SOURCES (RECEPTACLES). I CANALI DATI DEVONO DISTARE 30 cm DAI CANALI ELETTRICI; LE DERIVAZIONI DI TELECOM. DEVONO DISTARE 15 cm DALLE LINEE DI DERIVAZIONE ELETTRICHE. LE PRESE DATI E TELEFONICHE DEVONO ESSERE POSIZIONATE A 15 cm (NON DI PIU', NON DI MENO) DALLE FONTI DI ENERGIA (PRESE ELETTRICHE).
AutoCAD SHX Text 4.
AutoCAD SHX Text AT THE END OF THE WORK CONTRACTOR MUST PROVIDE TWO COPY OF AS BUILT DRAWINGS AND GEOSPATIAL INFORMATION FOR ALL HANDHOLE, MANHOLE, DUCT LINE AND CABLE INSTALLATIONS. THE SYSTEM DRAWINGS MUST SHOW SCHEMATICS OF THE ENTIRE COMMUNICATION AND DISTRIBUTION SYSTEM AND THE PHYSICAL RUNS OF ALL COMMUNICATION WIRING AND EQUIPMENT INSTALLED. (DRAWINGS SHOULD BE TURNED OVER TO THE BASE COMM. SQUADRON VIA THE 31 CE OFFICE, WHEN THE FACILITY IS TRANSFERRED FROM CONSTRUCTION AGENT TO THE AIR FORCE). ALL DRAWINGS MUST BE PROVIDED ALSO IN AN ELECTRONIC COPY, PREPARED ON CURRENT VERSION OF AUTOCAD. ALLA FINE DEL LAVORO L'IMPRESA DEVE FORNIRE DUE COPIE DI DISEGNI FINALI E RIFERIMENTI GEOSPAZIALI PER OGNI POZZETTO, CAMERETTA CAVI, TUBAZIONE E CAVO INSTALLATI. I DISEGNI DEVONO MOSTRARE LO SCHEMA DELL'INTERO IMPIANTO DI COMUNICAZIONI E DISTRIBUZIONE, ED I PERCORSI E POSIZIONI DI OGNI CABLAGGIO ED APPARECCHIO INSTALLATI. (I DISEGNI DEVONO ESSERE TRASMESSI ALLO SQUADRONE TELECOM. DELLA BASE ATTRAVERSO L'UFFICIO 31 CE, QUANDO L'EDIFICIO VIENE TRASFERITO DAL RESPONSABILE DELLA COSTRUZIONE ALLE FORZE AEREE). TUTTI I DISEGNI DEVONO ESSERE FORNITI ANCHE IN FORMA ELETTRONICA, PREPARATA NELLA VERSIONE CORRENTE DI AUTOCAD.
AutoCAD SHX Text 1.
AutoCAD SHX Text AS BUILT DRAWINGS, AS A MINIMUM, MUST SHOW CROSS-CONNECT AND TERMINATION POINTS FOR EACH CABLE PAIR, LOCATIONS AND IDENTIFICATION NUMBER FOR EACH MODULAR OUTLET AND THE LOCATION AND VALUE OF EACH LINE AMPLIFIER AND MULTI-PORT DEVICE THROUGHOUT THE CABLE SYSTEM. A COMMUNICATION RISER DIAGRAM AND CABLE ROUTING MUST ALSO BE SHOWN. SEPARATE DRAWINGS ARE EQUIRED FOR OUTSIDE PLANT AND INSIDE PLANT INSTALLATIONS. I DISEGNI FINALI "COME COSTRUITO", COME MINIMO, DEVONO MOSTRARE GIUNZIONI E TERMINAZIONI PER OGNI COPPIA DI CAVO, POSIZIONE E NUMERO IDENTIFICAZIONE DI OGNI PRESA MODULARE, POSIZIONE E VALORE DI OGNI AMPLIFICATORE DI LINEA E DISPOSITIVO MULTI-PORTA SUL SISTEMA. UN DIAGRAMMA DELL'IMPIANTO CON EVIDENZA DEI CAVI DEVE INOLTRE ESSERE MOSTRATO. LE INSTALLAZIONI ESTERNE ED INTERNE DEVONO ESSERE RAPPRESENTATE SU DISEGNI SEPARATI.
AutoCAD SHX Text 2.
AutoCAD SHX Text THE CONTRACTOR MUST RECORD GEOSPATIAL DATA AND PROVIDE "AS-BUILT" DOCUMENTATION (SHAPE FILES) OF ALL NEW INSTALLED MAINTENANCE HOLE SYSTEM (MHS) COMPONENTS (INCLUDING METADATA) COMPATIBLE WITH THE CYBERSPACE INFRASTRUCTURE PLANNING SYSTEM (CIPS) VISUALIZATION COMPONENT (CVC) DRAWING SYSTEM. DATA POINTS MUST BE RECORDED AT THE CENTER OF EACH MANHOLE/HANDOLE LID AND AT INTERVALS NOT TO EXCEED 25 ft (7.6 m) ALONG CABLE ROUTES. SUFFICIENT DATA POINTS MUST BE RECORDED TO CAPTURE ANY CHANGE IN DIRECTION ALONG THE ROUTE. ALL GPS COORDINATES MUST HAVE +/- 3 ft (0.9 m) ACCURACY FOR ALL READINGS. THE CONTRACTOR WILL RECEIVE, FROM GOVERNMENT, A COPY OF THE INSTALLATION'S MOST CURRENT GeoBase Common Installation Picture (CIP), AND CURRENT CVC DRAWINGS OF THE AREAS OF INTEREST. THE GOVERNMENT WILL REVIEW THE SHAPE FILES IN CVC AND TRASCRIBE THE INFORMATION TO THE CVC SYSTEM. SHAPE FILES SHALL BE DELIVERED UPON PROJECT COMPLETATION. L'IMPRESA DEVE REGISTRARE I DATI GEOSPAZIALI E FORNIRE DOCUMENTAZIONE "COME COSTRUITO" (FORMATO VETTORIALE SHAPEFILE) DI TUTTI I PUNTI INTERRATI SOGGETTI A MANUTENZIONE (MHS) (INCLUSE INFORMAZIONI METADATA). LA DOCUMENTAZIONE DEV'ESSERE COMPATIBILE CON IL SISTEMA GRAFICO DI PIANIFICAZIONE DELL'INFRASTRUTTURA CYBERSPAZIO (CIPS) DI VISUALIZZAZIONE (CVC). I PUNTI D'INFORMAZIONE DEVONO ESSERE REGISTRATI AL CENTRO DEL CHIUSINO D'OGNI POZZETTO E CAMERETTA CAVI ED AD INTERVALLI NON SUPERIORI A 7.6 m LUNGO IL PERCORSO DEI CAVI. DEV'ESSERE REGISTRATO UN NUMERO SUFFICIENTE DI PUNTI TALE DA IDENTIFICARE OGNI CAMBIO DI DIREZIONE DEL PERCORSO. LE COORIDNATE GPS DEVONO AVERE UNA PRECISIONE +/- 0.9 m IN OGNI LETTURA. L'IMPRESA RICEVERA', DAL GOVERNO, LA COPIA PIU' AGGIORNATA DELL'IMMAGINE GEOSPAZIALE DI POSA (CIP), E LA VERSIONE CORRENTE DEI DISEGNI DELL'AREA D'INTERESSE IN FORMATO CVC. IL GOVERNO REVISIONERA' I FILE IN FORMAT0 SHAPEFILE IN CVC E TRASCRIVERA' LE INFORMAZIONI AL SYSTEM CVC. I FILE VETTORIALI SHAPEFILE DOVRANNO ESSERE CONSEGNATI AL TERMINE DEL LAVORO.
AutoCAD SHX Text COMMUNICATION MANHOLE AND BUILDING PENETRATION DRAWINGS MUST BE PROVIDED ALSO IN "BUTTERFLY" FORMAT, WHICH SHOWN THE DUCT AND CABLES LAYOUT AS SHOWN BELOW. I DISEGNI DELLE CAMERETTE CAVI E DEI PUNTI DI PENETRAZIONE DI EDIFICIO DEVONO ESSERE FORNITI ANCHE IN VERSIONE "FARFALLA", CHE MOSTRA LA DISPOSIZIONE DI TUBI E CAVI COME MOSTRATO DI SEGUITO.
AutoCAD SHX Text 3.
AutoCAD SHX Text
MH TYPICAL
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TO BUILDING
AutoCAD SHX Text
TO BUILDING
AutoCAD SHX Text
TO BUILDING
AutoCAD SHX Text
TO BUILDING
AutoCAD SHX Text
INPUT SPLICE INFORMATION, MODEL, TYPE, DIMENSIONS, CASE MATERIAL, FILL MATERIAL
AutoCAD SHX Text INPUT DATA ABOUT CABLE, PAIR COUNT, SHEATH TYPE, ATTENUATION, CONDUCTOR SIZE. SHOW WHICH DUCTS EACH CABLE SEGMENT ENTER/EXITS. DESCRIBE INNERDUCTS USED/INSTALLED, TYPE, MATERIALS, DIMENSIONS
AutoCAD SHX Text INDICATE CONNECTING BUILDING OR NEXT CONTAINER. CROSS OUT NON-EXISTENT DUCTS. IE: ONLY SHOW ACTUAL NUMBERS OF DUCT OPENINGS.
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
TO MANHOLE?
AutoCAD SHX Text INDICATE CONNECTING MANHOLE OR NEXT CONTAINER. CROSS OUT NON-EXISTENT DUCTS. IE: ONLY SHOW ACTUAL NUMBERS OF DUCT OPENINGS.
AutoCAD SHX Text
INPUT SPLICE INFORMATION, MODEL, TYPE, DIMENSIONS, CASE MATERIAL, FILL MATERIAL
AutoCAD SHX Text
INDICATE CABLE DESTINATION "CER"
AutoCAD SHX Text INPUT DATA ABOUT CABLE, PAIR COUNT, SHEATH TYPE, ATTENUATION, CONDUCTOR SIZE. SHOW WHICH DUCTS EACH CABLE SEGMENT ENTER/EXITS. DESCRIBE INNERDUCTS USED/INSTALLED, TYPE, MATERIALS, DIMENSIONS
AutoCAD SHX Text THE CONTRACTOR MUST LABEL ALL INSTALLED EQUIPMENT AND CABLES IN ACCORDANCE WITH ANSI/TIA/EIA-606-A AND AS DIRECTED BY THE BASE COMMUNICATION ORGANIZATION. NEW DUCTS MUST BE PERMANENTLY LABELED ON THE WALL OF EACH BUILDING/MANHOLE INDICATING THE CONNECTING BLDG/MH AT THE OTHER END OF THE DUCT. THE COVER OF ALL NEW FIBER OPTIC DISTRIBUTION PANEL (FODP) MUST BE LABELED TO CONFORM THE SYSTEM USED BY LOCAL MAINTENANCE PERSONNEL TO IDENTIFY FODPs THAT TERMINATE FIBER. IF THE FODP MANUFACTURER HAS NOT IDENTIFIED THE SEQUENCE IN WHICH THE PORTS ARE COUNTED, THE CONTRACTOR MUST PROVIDE DESIGNATION LABELS/STRIPS TO IDENTIFY THE SEQUENCE IN WHICH THE PORTS ARE COUNTED. THE SAME INFORMATIONS MUST APPEAR ON THE CONTRACTOR'S COMPLETED AS-BUILT DRAWINGS. L'IMPRESA DEVE ETICHETTARE TUTTI I CAVI E LE APPARECCHIATURE INSTALLATI IN ACCORDO A ANSI/TIA EIA-606-A E COME CHIESTO DALL'ORGANIZZAZIONE DELLA BASE. I NUOVI CAVIDOTTI DEVONO ESSERE PERMANENTEMENTE ETICHETTATI SULLA PARETE DI OGNI EDIFICIO E DI OGNI CAMERETTA CAVI, INDICANDO L'EDIFICIO/CAMERETTA CAVI ALL'ALTRA ESTERMITA' DEL TUBO. I PANNELLI DI DISTRIBUZIONE DI FIBRA OTTICA (FODP) DEVONO ESSERE ETICHETTATI COME IN USO DAL PERSONALE DI MANUTENZIONE, PER IDENTIFICARE I PANNELLI A CUI LE FIBRE TERMINANO. SE IL COSTRUTTORE DEL PANNELLO (FODP) NON HA IDENTIFICATO LA SEQUENZA DI NUMERAZIONE DELLE PORTE IN FIBRA, LO DEVE FARE L'IMPRESA MEDIANTE APPLICAZIONE DI ETICHETTE. LE STESSE INFORMAZIONI DEVONO APPARIRE SUI DISEGNI "COME COSTRUITO" REDATTI DALL'IMPRESA.
AutoCAD SHX Text
EXAMPLE: FODP 162 ESEMPIO: FO 407-162,1-12FO 407-162,1-12
AutoCAD SHX Text min 12" (30 cm)
AutoCAD SHX Text min 2" (5 cm)
AutoCAD SHX Text min 12" (30 cm)
AutoCAD SHX Text min 2" (5 cm)
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
TELECOMMUNICATION SYSTEM - LEGEND OF SYMBOLS
AutoCAD SHX Text
IMPIANTO TELECOMUNICAZIONI - LEGENDA DEI SIMBOLI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
T-
2 INTERCOM SYSTEM LEGEND
LEGENDA IMPIANTO CITOFONICO
IP
MAIN
CCTV SYSTEM LEGEND
LEGENDA IMPIANTO TELECAMERE
CCTV
CCTV
LCD
CCTV
LAND MOBILE RADIO (LMR) SYSTEM LEGEND
LEGENDA IMPIANTO RADIO PORTATILE TERRESTRE
LMR
PUBLIC ADDRESS SYSTEM LEGEND
LEGENDA IMPIANTO DIFFUSIONE SONORA
PA
HANDICAPPED TOILET EMERGENCY CALL SYSTEM
IMPIANTO CHIAMATA SOCCORSO BAGNO DISABILE
INT
st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
T-002
AutoCAD SHX Text CCTV SYSTEM CAMERA, 1/3" CMOS 2 Mpxl (FULL HD), 3,6 mm LENS. #1 PORT RJ45 TYPE. PoE. ONFIV STANDARD. WEATHER PROOF TYPE TELECAMERA CON SENSORE 1/3" CMOS 2 Mpxl (FULL HD), LENTE 3,6 mm, PORTA RJ45. PoE. STANDARD ONVIF. ADATTA ALLA POSA IN ESTERNO.
AutoCAD SHX Text INTERCOM DEVICE, WEATHER PROOF TYPE FOR EXTERIOR AREA INSTALLATION CITOFONO ADATTO ALLA POSA IN ESTERNI
AutoCAD SHX Text
INTERCOM DEVICE, FOR INTERIOR AREA INSTALLATION CITOFONO INTERNO
AutoCAD SHX Text MAIN INTERCOM DEVICE, LOCATED ON THE RECEPTION'S COUNTER POSTAZIONE CITOFONICA PRINCIPALE, POSTA SUL BANCO DELLA RECEPTION
AutoCAD SHX Text NETWORK VIDEO RECORDER, #4 CHANNELS, WITH PoE SWITCH. #1 VGA, #1 HDMI OUTPUT. STANDARD PAL/NTSC. 2Mp (1080P). #1 RCA AUDIO OUTPUT. #4 INPUT TCP/IP TYPE. MEMORY: 2 SATA HDDs (1x2 TB). INSTALLED IN A 12" CABINET, WALL MOUNTED. 450 mm DEPTH CENTRALE VIDEOSORVEGLIANZA, N.4 CANALI, CON SWITCH PoE. USCITE: N.1 VGA, N.1 HDMI. STANDARD PAL/NTSC. 2Mp (1080P). N.1 USCITA AUDIO RCA. N.4 INGRESSI TCP/IP. MEMORIA: 2 DISCHI SATA (1x2 TB). INSTALLATO IN ARMADIETTO A PARETE, 12 UNITA', 450 mm PROFONDO
AutoCAD SHX Text DISPLAY, 10 " LCD TYPE, MOUNTED ABOVE THE RECEPTION COUNTER. DISPLAY LCD 10" DEL SISTEMA TVCC, POSTO SUL BANCONE DELLA RECEPTION
AutoCAD SHX Text NOTE CCTV SYSTEM IS ONLY FOR AUTOMATIZED GATE AREA MONITORING. IF NOT OOTHERWISE INDICATED, RECORDING SHALL BE LIMITED TO 1 DAY. NOTA L'IMPIANTO TVCC E' SOLO PER IL CONTROLLO DELL'AREA DEL CANCELLO AUTOMATICO. SE NON DIVERSAMENTE INDICATO, LA REGISTRAZIONE DOVRA' ESSERE LIMITATA A 1 GIORNO.
AutoCAD SHX Text NOTE INTERCOM SYSTEM ALLOWS THE COMMUNICATION FROM THE EXTERIOR AREA TO THE INTERIOR OF THE BUILDING. THE EXTERIOR DEVICES SHALL BE INSTALLED AT THE MAIN ENTRY (ROOM 01) AND OUTSIDE THE NEW AUTOMATIC GATE. THE INTERIOR DEVICES SHALL BE INSTALLED AT THE RECEPTION AND IN THE LOBBY OF THE EXPANSION AREA. AUTOMATIC GATE CONTROLS SHALL BE POSSIBLE BY A PUSH-BUTTON CONSOLLE INSTALLED AT THE RECEPTION COUNTER AND BY THE INTERCOM DEVIDE INSTALLED IN THE EXPANSION. ENTRANCE AT B939 AREA SHALL BE ONLY MANUAL, AUTHORIZED BY PERSONNEL; EXIT FROM B939 AREA SHALL BE AUTOMATIC, CONTROLLED BY A LOOP CABLE RECESSED IN THE PAVEMENT, 5 cm DEPTH NOTA L'IMPIANTO CITOFONICO PERMETTE LA COMUNICAZIONE TRA ESTERNO ED INTERNO DELL'EDIFICIO. I DISPOSITIVI ESTERNI DOVRANNO ESSERE INSTALLATI ALL'INGRESSO PRINCIPALE (LOCALE 01) ED ALL' ESTERNO DEL NUOVO CANCELLO AUTOMATICO. I DISPOSITIVI INTERNI DOVRANNO ESSERE INSTALLATI NELLA RECEPTION E NELL'ATRIO DELL'AMPLIAMENTO. IL CONTROLLO DEL CANCELLO AUTOMATICO SARA' POSSIBILE DALLA PULSANTIERA POSTA SUL BANCO DELLA RECEPTION E DAL CITOFONO INSTALLATO NELL'ATRIO DELL'ESPANSIONE. L'INGRESSO ALL'EDIFICIO SARA' MANUALE, AUTORIZZATO DAL PERSONALE. L'USCITA SARA' AUTOMATICA, CONTROLLATA DA UNA SPIRA POSTA A 5 CM SOTTO LA PAVIMENTAZIONE.
AutoCAD SHX Text EXISTING LAND MOBILE RADIO EQUIPMENT, TO BE MAINTAINED. CONNECTION TO THE EXTERIOR ANTENNA SHALL BE NEW: A NEW COAXIAL CABLE WIRED THROUGH A NEW RECESSED CONDUIT SHALL BE PROVIDED AND INSTALLED. TRACES AND HOLES THROUGH WALLS ARE INCLUDED APPARATO RADIO PORTATILE TERRESTRE ESISTENTE, DA MANTENERE. IL COLLEGAMENTO ALL'ANTENNA ESTERNA DOVRA' ESSERE NUOVO: UN NUOVO CAVO COASSIALE INFILATO IN NUOVO TUBO INCASSATO DOVRA' ESSERE FORNITO ED INSTALLATO, TRACCE E FORI A PARETE SONO COMPRESI
AutoCAD SHX Text EXISTING ANTENNA: TO REMOVE AND REINSTALL AFTER COMPLETATION OF FACADE WORKS. PERFORM AN ORDINARY MAINTENANCE BEFORE REINSTALLATION. CONNECT TO THE RADIO EQUIPMENT WITH NEW CABLE TYPE MIL-C-17 (N17/163-00001) ANTENNA ESISTENTE: RIMUOVERE E REINSTALLARE A FINE LAVORI IN FACCIATA. ESEGUIRE UNA MANUTENZIONE ORDINARIA PRIMA DI REINSTALLARLA. COLLEGARE ALL'APPARATO RADIO TRAMITE NUOVO CAVO TIPO MIL-C-17 (N17/163-00001)
AutoCAD SHX Text PUBLIC ADDRESS SYSTEM EQUIPMENT, COMPOSED BY AN AMPLIFIER AND A MICROPHONE. MOUNTED ABOVE THE COUNTER DESK OF THE RECEPTION APPARATO DI DIFFUSIONE SONORA, COMPOSTO DA UN AMPLIFICATORE ED UN MICROFONO. POSTI SOPRA IL BANCO DELLA RECEPTION
AutoCAD SHX Text LOUDPEAKER, FITTED TO BE RECESSED ON FALSE CEILING ALTOPARLANTE, ADATTO AD ESSERE INCASSATO A CONTROSOFFITTO
AutoCAD SHX Text PULL CORD PUSH-BUTTON, CONTROLED AT 90 cm A.F.F. - DISABLED HELP REQUEST - DISABLED HELP REQUEST PULSANTE A TIRANTE AZIONABILE A 90 cm DAL PAVIMENTO FINITO - RICHIESTA SOCCORSO DISABILI
AutoCAD SHX Text PUSH BUTTON CONTROLLED AT 90 cm A.F.F., TO RESET THE DISABLED HELP REQUEST DISABLED HELP REQUEST PULSANTE AZIONABILE A 90 cm DAL PAVIMENTO FINITO, PER ANNULLO RICHIESTA SOCCORSO DISABILI
AutoCAD SHX Text VISUAL & ACOUSTICAL ALARM, AT 225 cm A.F.F. ALLARME OTTICO ACUSTICO, A 225 cm DAL PAVIMENTO
AutoCAD SHX Text LOUDPEAKER, WEATHER-PROOF TYPE, FITTED FOR OUTDOOR INSTALLATION ALTOPARLANTE, RESISTENTE AGLI AGENTI ATMOSFERICI, ADATTO PER POSA IN ESTERNO
AutoCAD SHX Text
WP
AutoCAD SHX Text
INTERCOM SYSTEM POWER SUPPLY (SWITCHING) ALIMENTATORE IMPIANTO CITOFONICO
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SPECIAL SYSTEMS - LEGEND OF SYMBOLS
AutoCAD SHX Text
IMPIANTI SPECIALI - LEGENDA DEI SIMBOLI
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
| 105_B939-E-001-100%.pdf |
| 127_B939-E-610-100%.pdf |
| Fogli e viste |
| E-610 |
| 128_B939-E-611-100%.pdf |
| Fogli e viste |
| E-611 DALI |
| 129_B939-T-001-100%.pdf |
| Fogli e viste |
| T-001 |
| 130_B939-T-002-100%.pdf |
| Fogli e viste |
| T-002 |
File details come from the government source that posted it. Updated .