Attachment_11_ASHE_18-1025_Drawings_(Seed_project)_Part13_Part1.pdf
PDF 2 MB Posted
- Attached to
- Multiple Award Construction Contract (MACC) Italy Federal contract opportunity
- Solicitation number
- FA568219RA001
About this file
This is a draft pre-solicitation notice for an indefinite delivery indefinite quantity multiple award construction contract to be awarded in Italy. The contract will have a one year base period with four option years and will have a minimum value of $2,500 and maximum total value of $96 million. Work will include design, repair, alteration, renovation, maintenance and minor construction projects at Aviano Air Base and will cover trades such as grading, utilities, painting, roofing, HVAC, electrical and abatement. The minimum task order value is $2,500 and maximum is $7 million. Comments on the draft solicitation attachments are due by April 19, 2019. The solicitation is expected to be issued on www.fbo.gov in May 2019 for design-build construction services in Italy under NAICS 236220.
Attachment 11 ASHE 18-1025 Drawings (Seed Project) Part 13 Part 1
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC) Italy has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MGB
GB/2
TMGB
FA
T
LM
R st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
GROUNDING AND LIGHTNING SYSTEMS / IMPIANTI DI TERRA E PROTEZIONE CONTRO I FULMINI E-103
GENERALE NOTES
NEW WORK KEYNOTES
EXISTING ITEM KEYNOTES
NOTA CHIAVE ESISTENTE
NOTA CHIAVE NUOVO INTERVENTO
NOTE GENERALI
SCALASCALE /
N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text
EXISTING GROUNDING CONDUCTOR, TO LEFT IN PLACE
AutoCAD SHX Text
DISPERSORE DI TERRA ESISTENTE, DA MANTENERE
AutoCAD SHX Text
SCALE 1:100
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1:100
AutoCAD SHX Text
EXISTING GROUNDING HANDHOLE, TO LEFT IN PLACE
AutoCAD SHX Text
POZZETTO DI TERRA ESISTENTE, DA MANTENERE
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text
GROUNDING AND LIGHTNING SYSTEMS
AutoCAD SHX Text
IMPIANTI DI TERRA E PROTEZIONE FULMINI
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text
AutoCAD SHX Text COPPER GROUND ROD, 20 mm x 3000 mm, INTO PRE-CASTHANDOLE, 40x40 cm, WITH CAST IRON COVER DISPERSORE A PICCHETTO IN RAME, 20 x 3000 mm, ENTROPOZZETTO DI TERRA IN CLS PREFABBRICATO, 40x40 cm, CON CHIUSINO IN GHISA
AutoCAD SHX Text MAIN GROUND BAR: MOUNTED AT 500 mm ABOVE FINISHED FLOOR TO CENTER OR INSIDE THE MAIN DISTRIBUTION PANELBOARD COLLETTORE DI TERRA PRINCIPALE: INSTALLATO A 500 mm DAL PAVIMENTO FINITO O ENTRO IL QUADRO ELETTRICO PRINCIPALE
AutoCAD SHX Text COPPER GROUND LOOP CONDUCTOR, 50 sq.mm, DIRECT BURIED AT 600 mm BELOW FINISHED GRADE DISPERSORE DI TERRA IN CORDA DI RAME 50 mmq, DIRETTAMENTE INTERRATO A 600 mm SOTTO IL LIVELLO DEL TERRENO
AutoCAD SHX Text MAIN GROUND CONDUCTOR: FS17 TYPE CABLE, 1x95 sq.mm, WIRED THROUGH PVC CONDUIT (SAME USED FOR POWER CABLES) CONDUTTORE DI TERRA PRINCIPALE: CAVO FS17, 1x95 mmq, IN TUBO PVC (LO STESSO TUBO UTILIZZATO PER I CAVI DI ENERGIA)
AutoCAD SHX Text 4.
AutoCAD SHX Text SECONDARY GROUND CONDUCTOR: FS17 CABLE, 1x50 sq.mm, WIRED THROUGH PVC CONDUIT (SAME USED FOR POWER CABLES) CONDUTTORE DI TERRA SECONDARIO: FS17, 1x50 mmq, IN TUBO PVC (LO STESSO TUBO UTILIZZATO PER I CAVI DI ENERGIA)
AutoCAD SHX Text 5.
AutoCAD SHX Text SECONDARY GROUND BAR: MOUNTED AT 500 mm ABOVE FINISHED FLOOR TO CENTER OR INSIDE THE SECONDARY PANELBOARD COLLETTORE DI TERRA SECONDARIO: INSTALLATO A 500 mm DAL PAVIMENTO FINITO O ENTRO IL QUADRO ELETTRICO SECONDARIO
AutoCAD SHX Text 6.
AutoCAD SHX Text TELECOMMUNICATION (SYSTEM) GROUND BAR: MOUNTED AT 500 mm ABOVE FINISHED FLOOR TO CENTER. CONNECTED TO THE MGB BY FG17 TYPE CABLE, 1x35 sq.mm COLLETTORE DI TERRA IMPIANTO TELECOMUNICAZIONI: INSTALLATO A 500 mm DAL PAVIMENTO FINITO. COLLEGATO AL MGB TRAMITE UN CONDUTTORE TIPO FG17 DA 1x35 mmq
AutoCAD SHX Text 7.
AutoCAD SHX Text CONNECTION OF FOUNDATION METALLIC GRID TO THE GROUNDING SYSTEM, BY USING A 50 sq.mm COPPER CONDUCTOR COLLEGAMENTO DELLE RETI METALLICHE DI FONDAZIONE AL SISTEMA DI TERRA, MEDIANTE USO DI CORDA DI RAME 50 mmq
AutoCAD SHX Text 8.
AutoCAD SHX Text IF THE EXCAVATION WORKS ALLOWS TO FIND THE GROUNDING LOOP OF THE NEW STORAGE, CONNECTION TO THE B939 GROUNDING SYS MUST BE REALIZED USING A 50 sq.mm COPPER CONDUCTOR SE I LAVORI DI SCAVO METTERANNO IN LUCE IL DISPERSORE DI TERRA DEL NUOVO DEPOSITO, UN COLLEGAMENTO AL SISTEMA DI DISPERSIONE DELL'EDIFICIO B939 DOVRA' ESSERE FATTO MEDIANTE UN CONDUTTORE IN RAME 50 mmq
AutoCAD SHX Text 9.
AutoCAD SHX Text CONNECTION OF THE FIRE ALARM SYSTEM ANTENNA-SPD TO THE GROUNDING SYSTEM, BY USING A 1x16 mmq COPPER CONDUCTOR COLLEGAMENTO DELL'SPD DELL'ANTENNA ALLARME INCENDIO ALL' IMPIANTO DI TERRA, MEDIANTE CONDUTTORE IN RAME 1x16 mmq
AutoCAD SHX Text 10.
AutoCAD SHX Text CONNECTION OF THE RADIO ANTENNA TO THE GROUNDING SYSTEM, BY USING A 1x16 mmq COPPER CONDUCTOR COLLEGAMENTO DELLA STRUTTURA METALLICA DELL'ANTENNA RADIO ALL' IMPIANTO DI TERRA, MEDIANTE CONDUTTORE RAME 1x16 mmq
AutoCAD SHX Text 11.
AutoCAD SHX Text LIGHTNING SYSTEM DOWN CONDUCTOR TO GROUNDING, INCLUDING A TEST BREAKER INSIDE A UV-RESISTANT PLASTIC BOX, MOUNTED ON WALL AT 1200 mm ABOVE GRADE. CONNECTION TO GROUNDING SYSTEM WITH A COPPER CONDUCTOR 1x95 sq.mm CALATA DELL'IMPIANTO PARAFULMINE AL DISPERSORE DI TERRA, INCLUSO UN SEZIONATORE DI TEST IN BOX DI PLASTICA RESISTENTE AI RAGGI UV, INSTALLATA A PARETE A 1200 mm DAL TERRENO. COLLEGAMENTO ALL'IMPIANTO DI TERRA IN RAME DA 1x95 mmq
AutoCAD SHX Text 12.
AutoCAD SHX Text GROUNDING PITS MUST BE HIGHLIGHTED BY METALLIC SIGNS, TO BE FIXED ON WALLS NEAR THE GROUNDINH HANDHOLES I POZZETTI DI TERRA DOVRANNO ESSERE EVIDENZIATI MEDIANTE CARTELLI METALLICI, DA FISSARE A PARETE VICINO AI POZZETTI
AutoCAD SHX Text 1.
AutoCAD SHX Text m st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
LIGHTNING SYSTEMS / IMPIANTO DI PROTEZIONE CONTRO I FULMINI
E-104
PHOTOVOLTAIC SYSTEM ON ROOF
N
/ IMPIANTO FOTOVOLTAICO IN COPERTURA
N
GENERALE NOTES
NEW WORK KEYNOTES
EXISTING ITEM KEYNOTES
NOTA CHIAVE ESISTENTE
NOTA CHIAVE NUOVO INTERVENTO
NOTE GENERALI
SCALASCALE /
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
GL
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
AutoCAD SHX Text Accessible area: minimum 180 cm, IAW UFC 3-440-01 article 3-3.12.1.1 Area acceso: minimo 180 cm, IN ACCORDO A UFC 3-440-01, articolo 3-3.12.1.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text min. 1.20 m
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2.
AutoCAD SHX Text
EXISTING GROUNDING LOOP, TO LEFT IN PLACE
AutoCAD SHX Text
DISPERSORE DI TERRA ESISTENTE, DA MANTENERE
AutoCAD SHX Text
SCALE 1:100
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1:150
AutoCAD SHX Text
EXISTING GROUNDING HANDHOLE, TO LEFT IN PLACE
AutoCAD SHX Text
POZZETTO DI TERRA ESISTENTE, DA MANTENERE
AutoCAD SHX Text 1.
AutoCAD SHX Text
LIGHTNING AND PHOTOVOLTAIC SYSTEMS
AutoCAD SHX Text
IMPIANTI PROTEZIONE FULMINI E FOTOVOLTAICO
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text
AutoCAD SHX Text MESHED CONDUCTOR: STRANDED COPPER WIRE min. 50 sq.mm CAPTATORE A GABBIA: CORDA DI RAME MINIMO 50 mmq
AutoCAD SHX Text PHOTOVOLTAC SYSTEM: 270Wp Ea. POLYCHRISTALLINE TYPE MODULS IMPIANTO FOTOVOLTAICO: MODULI POLICRISTALLINI, 270Wp CIASCUNO
AutoCAD SHX Text 4.
AutoCAD SHX Text FOR THE GROUNDING SYSTEM SEE NOTES ON SHEET E-103 PER LE NOTE ALL'IMPIANTO DI TERRA VEDERE LA TAVOLA E-103
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text DOWN CONDUCTOR WITH TEST BREAKER: 50 sq.mm STRANDED COPPER WIRE FROM ROOF TILL THE TEST BREAKER. 50 sq.mm INSULATED COOPER CABLE WIRED THROUGH METAL CONDUIT 25 mm, FROM THE TEST BREAKER TO GROUNDINGSYSTEM PIT. REUSE OF THE EXISTING 95 sq.mm CABLES IS APPROVED. CALATA COMPRENSIVA DI SEZIONATORE PER TEST: CORDA DI RAME 50 mmq FINO AL SEZIONATORE DI TEST CORDA ISOLATA 50 mmq IN TUBO METALLICO 25 mm, DALSEZIONATORE DI TEST FINO AL POZZETTO DI TERRA. IL RIUTILIZZO DELLE CORDE ESISTENTI 95 mmq E' APPROVATO
AutoCAD SHX Text 3.
AutoCAD SHX Text AIR TERMINAL ROD, 2 m HIGH ASTA DI CAPTAZIONE, ALTEZZA 2 m
AutoCAD SHX Text
SCALE 1:150
AutoCAD SHX Text 5.
AutoCAD SHX Text GALVANIZED STEEL CABLE TRAY WITH COVER, MESH WIRE TYPE, 75x50 mm, LAID ABOVE THE ROOF CANALE A FILO IN ACCIAIO ZINCATO CON COPERCHIO, DIMENSIONE 75x50 mm, POSATO SULLA COPERTURA
AutoCAD SHX Text 6.
AutoCAD SHX Text CABLE ENTRANCE INTO THE ELECTRICAL ROOM, WHERE INVERTER IS INSTALLED: 40 mm GALVANIZED STEEL CONDUITINGRESSO NEL LOCALE ELETTRICO, DOVE E' INSTALLATO L'INVERTER: TUBO 40 mm IN ACCIAIO ZINCATO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1:100
AutoCAD SHX Text m
AutoCAD SHX Text m
AutoCAD SHX Text ACCORDING TO GSA FEDERAL Bldgs PHOTOVOLTAIC SYSTEM GUIDELINE: CCORDING TO GSA FEDERAL Bldgs PHOTOVOLTAIC SYSTEM GUIDELINE: ALL DC CONDUITS, RACEWAYSW, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES, etc. ASSOCIATED WITH THE PV SYSTEM SHALL BE MARKED "CAUTION: PV CIRCUIT ENERGIZED" EVERY 3 m TO ALERT INDIVIDUALS THAT DC POWER IS PRESENT. IN ACCORDO ALLA GUIDA GSA PER I SISTEMI FV SUIGLI EDIFICI FEDERALI: TUTTE LE CONDUTTURE, SCATOLE, ecc. DELL'IMPIANTO FOTOVOLTAICO SARANNO MARCATE "ATTENZIONE: CIRCUITI FV IN TENSIONE" OGNI 3 m, PER ALLERTARE LE PERSONE DELLA PRESENZA TENSIONE IN CORRENTE CONTINUA
AutoCAD SHX Text 7.
AutoCAD SHX Text ACCORDING TO GSA FEDERAL Bldgs PHOTOVOLTAIC SYSTEM GUIDELINE: CCORDING TO GSA FEDERAL Bldgs PHOTOVOLTAIC SYSTEM GUIDELINE: THERE SHALL BE A Minimum OF 1.20 m WIDE CLEAR PERIMETER AROUND THE EDGES OF THE ROOF (1.80 m FOR Bldg WITH AXIS OF MORE THAN 76 m - 250 ft) EACH ARRAY SHALL NOT BE GREATER THAN 45x45 m (150x150 ft) THE PATHWAYS SHALL BE LOCATED OVER STRUCTURAL ROOF MEMBERS IN ACCORDO ALLA GUIDA GSA PER I SISTEMI FV SUGLI EDIFICI FEDERALI: CI DOVRA' ESSERE UNO SPAZIO Min. DI 1.20 m SUL PERIMETRO DEL TETTO (1.80 m PER TETTI DI LUNGHEZZE SUPERIORI A 75 m - 250 ft) OGNI CAMPO FOTOVOLTAICO DOVRA' ESSERE' PIU' PICCOLO DI 45x45 m I PERCORSI SUL TETTO DOVRANNO ESSERE SU PARTI STRUTTURALI
8.
P-BR
300x75300x75 300x75 300x75
300x75
0x
0x
PB.BR
PB.AHU1
MDP/2
PB.AHU2
0x
MDP
150x75
0x
EI 120 EI 120
EI 120
EI 120
EI 120
EI 120
5Ø40
300x75 300x75 300x75
0x
0x
75 PB.K1
150x75
EI 120
EI 120
0x
75 EI 120
PB.SPR
EI 120
100x75
150x75
PB.PV
P-MAINP-PV
PB.COMM
st
C
IV
IL
E
N G
IN
E
E R
IN
G
S Q
U A
D R
O N st
C E
S /C
E N
M P
R O
JE
C
T M
A N
A G
E M
E N
T E
LE
M
E N
T st
F
IG
H
TE
R W
IN
G
100%
Engineering Tools Srl
Via del Makò n. 33
33084 Cordenons (PN)
TEL.: +39 0434 536333
FAX: +39 0434 542813
E-mail: info@engtools.eu
PEC: info@pec.engtools.eu
POWER SYSTEM
E-105
/ IMPIANTO FORZA MOTRICE
ROOMS FEEDED BY UPS/ LOCALI ALIMENTATI DA UPS
GENERALE NOTES
NEW WORK KEYNOTES
NOTA CHIAVE NUOVO INTERVENTO
NOTE GENERALI
SCALASCALE /
N
N
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 25.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 25.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SIZE: A1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
PROJECT NUMBER: ASHE 18-1025
AutoCAD SHX Text
AutoCAD SHX Text
REVIEWER:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
DRAFTMAN:
AutoCAD SHX Text
SUBMITTAL
AutoCAD SHX Text
AVIANO AIR BASE
AutoCAD SHX Text
AVIANO, ITALY
AutoCAD SHX Text
FAC.939, AREA F, AVIANO AB, ITALY
AutoCAD SHX Text
RENOVATE/EXPAND FAC.939 FOR EOD
AutoCAD SHX Text
FABBR.939, AREA F, AVIANO AB, ITALIA
AutoCAD SHX Text
RISTRUTTURAZIONE ED AMPLIAMENTO FABBR.939 PER EOD
AutoCAD SHX Text
FEBRUARY 2019
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE 1:100
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1:200
AutoCAD SHX Text
ALL BUT THE EXISTING ELETRICAL SYSTEM, EXCEPT THOSE EXISTING
AutoCAD SHX Text 1.
AutoCAD SHX Text LA MODIFICA DELL'EDIFICIO No. 939 COMPORTA LA RIMOZIONE DI
AutoCAD SHX Text
RE-MODELING OF THE BUILDING #939 REQUIRE THE REMOVING OF
AutoCAD SHX Text
IN THE SPACES NON SUBJECT TO MODIFIES.
AutoCAD SHX Text
QUASI TUTTI GLI IMPIANTI ELETTRICI ESISTENTI, AD ECCEZIONE DI
AutoCAD SHX Text
QUELLI INSTALLATI NEGLI AMBIENTI NON SOGGETTI A MODIFICHE.
AutoCAD SHX Text 2.
AutoCAD SHX Text
GLI IMPIANTI ELETTRICI NELL'AMPLIAMENTO SARANNO TUTTI NUOVI
AutoCAD SHX Text
ELECTRICAL SYSTEMS IN THE EXPANSION WILL BE ALL NEW
AutoCAD SHX Text
AutoCAD SHX Text
NEW MAIN ELECTRICAL ROOM
AutoCAD SHX Text 1.
AutoCAD SHX Text
NUOVO LOCALE ELETTRICO PRINCIPALE
AutoCAD SHX Text 2.
AutoCAD SHX Text FeZn CABLE TRAY INSTALLED ABOVE THE FALSE CEILING
AutoCAD SHX Text 3.
AutoCAD SHX Text
CANALE IN ACCIAIO ZINCATO INSTALLATO SOPRA CONTROSOFFITTO
AutoCAD SHX Text
NEW ELECTRICAL ROOM IN THE EXPANSION BUILDING
AutoCAD SHX Text
NUOVO LOCALE ELETTRICO NELL'EDIFICIO AMPLIAMENTO
AutoCAD SHX Text
CABLE TRAYS FOR POWER SYSTEM
AutoCAD SHX Text
CANALI PORTACAVI ENERGIA
AutoCAD SHX Text
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text B.B.
AutoCAD SHX Text
CEILING
AutoCAD SHX Text 4.
AutoCAD SHX Text
TUBAZIONI IN PVC RIGIDO NELLO SPAZIO NASCOSTO SOPRA I
AutoCAD SHX Text
RIGID PVC CONDUITS IN THE HIDDEN SPACE ABOVE THE FALSE
AutoCAD SHX Text
CONTROSOFFITTI
AutoCAD SHX Text
SCALE 1:200
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1:100
AutoCAD SHX Text
FED BY UPS SECTION OF THE MAIN DISTRIBUTION PANEL. SEE
AutoCAD SHX Text 5.
AutoCAD SHX Text
LOCALI IN CUI TUTTE O PARTE DELLE PRESE DI ENERGIA SONO
AutoCAD SHX Text
ROOMS WHERE ALL OR PART OF THE POWER RECEPTACLES ARE
AutoCAD SHX Text
ALIMENTATE DALLA SEZIONE UPS DEL QUADRO ELETTRICO GENERALE.
AutoCAD SHX Text
SHEET E-106 TO UNDERSTAND WHICH RECEPTACLES ARE INVOLVED.
AutoCAD SHX Text
VEDERE LA TAVOLA E-106 PER COMPRENDERE QUALI SONO LE
AutoCAD SHX Text
PRESE INTERESSATE
AutoCAD SHX Text m
AutoCAD SHX Text m
AutoCAD SHX Text EMERGENCY SWITCH-OFF PUSH-BUTTON CLEARLY LABELLED "BUILDING SYSTEM" PULSANTE DI SGANCIO EMERGENZA CHIARAMENTE ETICHETTATO "IMPIANTO EDIFICIO"
AutoCAD SHX Text 6.
AutoCAD SHX Text EMERGENCY SWITCH-OFF PUSH-BUTTON CLEARLY LABELLED "PHOTOVOLTAIC SYSTEM" PULSANTE DI SGANCIO EMERGENZA CHIARAMENTE ETICHETTATO "IMPIANTO FOTOVOLTAICO"
AutoCAD SHX Text 7.
AutoCAD SHX Text EMERGENCY SWITCH-OFF PUSH-BUTTON CLEARLY LABELLED "BOILER ROOM SYSTEM" PULSANTE DI SGANCIO EMERGENZA CHIARAMENTE ETICHETTATO "IMPIANTO LOCALE CALDAIA"
8.
| 105_B939-E-001-100%.pdf |
| 109_B939-E-103-100%.pdf |
| Fogli e viste |
| E-103 ground |
| 110_B939-E-104-100%.pdf |
| Fogli e viste |
| E-104 lightning |
| 111_B939-E-105-100%.pdf |
| Fogli e viste |
| E-105 cabletray |
File details come from the government source that posted it. Updated .