FA520524R00010004_Atch1_Addendum No 2_21Mar24.pdf
PDF 103 KB Posted
- Solicitation number
- FA520524R0001
About this file
This document is an Addendum to a federal solicitation for Project QKKA20-4002 to repair 29 Military Family Housing (MFH) units at Misawa Air Base, Japan. The addendum includes the following changes:
- Revised drawings for the metal roof design, changing the basis of design from "Fukuizumi" to "Kaname Roof" and revising the enclosure ratings from IP66 to IP44.
- Deleted lighting fixture items from the Contractor Furnished U.S. Material (CFUSM) list for several of the MFH units.
- Consolidated questions and responses from prospective offerors, including clarifications on the metal roof specifications, lighting fixtures, and references to the Statement of Work.
The related federal contract opportunity is Solicitation Number FA520524R0001 for Project No. QKKA204002 to repair the 29 MFH units at Misawa Air Base, Japan. The solicitation is being issued by the Department of the Air Force Pacific Air Forces.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM No. 2
FOR
PROJECT QKKA 20-4002
REPAIR JNCO HOMES, 29 UNITS (B221, 712, 716, 718, 723, 812, 817, 818)
MISAWA AIR BASE, JAPAN
21 March 2024
The project scope of work is amended to provide the following changes:
1. Drawings
a. Drawing 3B-A-605: Revised Basis of Design for MTL ROOF to from “Fukuizumi”
“Kaname Roof.”
i) 2 a: Revised manufacturer name and product information.
b. Drawing A-601: Revised Basis of Design for MTL ROOF to from “Fukuizumi”
“Kaname Roof.”
i) 2 a: Revised manufacturer name and product information.
c. Drawing 3B-E-503: Revised Detail 1 Note 5 from “IP66” to “IP44.”
i) 2 a: Revision to enclosure ratings.
2. List of Contractor Furnished U.S. Material (CFUSM)
a. MFH 221:
i) 2 a: Deleted lighting fixtures, item numbers 003 through 011.
b. MFH 712, 716, 718, 723, 812, 817, 818:
i) 2 b: Deleted lighting fixtures, item numbers 003 through 012.
Attachment 1 to
FA520524R00010004
3. Consolidated List of Prospective Offerors’ Submitted Questionnaire and U.S. Government
Response/Clarification
a. Query No. 28: Revised reference to specification section 01 00 00 paragraph 1.4.
b. Query No. 29: Added information on Japanese manufacturer for METAL ROOF, Kaname roof with insulating foam (old name is GAOU). Added reference to
Addendum 2. Revised reference to specification section 01 00 00 paragraph 1.4.
c. Query No. 154: Revised response to indicate that IP44 is acceptable. Added reference to
Addendum 2.
d. Query No. 155: Revised response to indicate that U.S. and local lighting fixtures are acceptable.
e. Query No. 165: Revised reference to specification section 01 00 00 paragraph 1.4.
Attachments:
1. Revised Drawings: 3B-A-605, A-601, 3B-E-503.
2. Revised List of Contractor Furnished U.S. Material (CFUSM)
3. Revised Consolidated List of Prospective Offerors’ Submitted Questionnaire and U.S.
Government Response/Clarification