Amendment Attachment 5 - Drawings.pdf
PDF 6 MB Posted
- Attached to
- Exxhaust Sys Mxs Eielson AFB Federal contract opportunity
- Solicitation number
- FA500421Q0004
About this file
This document contains drawings and specifications for an exhaust system for a food service facility. The project involves installing a new exhaust hood system with makeup air and heat recovery units. Key equipment includes a walk-in freezer, walk-in cooler, reach-in freezer, and various food preparation tables. Ductwork and exhaust fans will be provided along with a fire suppression system. Digital controls will regulate all ventilation components. The contractor must clean and maintain existing kitchen exhaust systems at Eielson Air Force Base in Alaska in accordance with industry standards and military regulations. Maintenance includes inspecting and repairing all parts of the ventilation systems from air inlets to exhaust outlets, including dampers, air handlers, units with coils and controls, ductwork, hoods, and digital components. The contractor will remove all grease deposits and clean surfaces to bare metal.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA500421Q00040001 SF 30 Issued.pdf | ||
| Amendment Attachment 4 - Site Visit Q and A.pdf | ||
| Attachment 1 - PWS.pdf | ||
| Attachment 4 - FA500421Q0004.pdf | ||
| Attachment 2- Clause Addendums.pdf | ||
| Combo Cover Letter - Exhaust Sys Mxs.pdf | ||
| Attachment 3 - Wage Determination.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
D
E
F
G
9 10
TOILET
TOILET
TOILET
STORAGE
KIT JAN
REST
KIT STOR
ELEC
MECH
STORAGE
14'-1 1/8" 18'-8 7/8"
14'-1 1/8"
11 7/8"
9' -9
/8
/8
TRASH
CAN
GREASE INTERCEPTOR
UNDER DISH TABLE
FS
EP
FULL HEIGHT WALL
COOLERFREEZER
TRASH
CAN
K-CLASS HAND HELD
FIRE EXTINGUISHER
EXHAUST HOOD FIRE SYSTEM
REMOTE PULL STATION
CONCEAL CONDUIT IN WALL
TRASH
CAN
K-100
FOOD.SERVICE.PLAN
1/4.SCALE
KI
TC
H
EN
.P
LA
N
EQ
U
IP
M
EN
T
FO
O D
.S
ER
VI
C
E
TF
A
TF
A
TF
A
K-100
SO
LI
C
IT
AT
IO
N N
O
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
IS
SU
E D
AT
E:
SI
ZE
C H
EC
KE
D B
Y:
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
SHEET ID
D
AT
E
FA
IR
BA
N
KS
, A
LA
SK
A
(9
) 4
-1
| A
EC
C
C O
LL
EG
E R
O
AD
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
AL
AS
KA
D
IS
TR
IC
T
EI
EL
SO
N
A
IR
F O
R C
E
BA
SE
, A
LA
SK
A
EI
E3
S C
H O
O L
AG
E
SE
R
VI
C
ES
D
P6
C O
N
SO
LI
D
AT
ED
D
ES
IG
N
C O
M
PL
ET
E
AN
SI
D
F
EB
W
1K B-
-R
-0
W
1K B-
-C
-0
US Army Corps Of Engineers ®
D
ES
IG
N
A
LA
SK
A
FA
IR
BA
N
KS
, A
K
(9
) 4
-5
S C
H
AC
H T
ST
R
EE
T
G H
EM
M
C O
M
PA
N Y, IN
C
R
FI
-0
- K
IT
C
H
EN
C O
IL
IN
G C
O U
N
TE
R D
O O
R
R
FI
-0
- I
TE
M
P
AN
S
TO
R
AG
E
SH
EL
VI
N
G
R
FI
- R
EA
C
H
IN
F R
EE
ZE
R
/1
6/
/0 6/
/0
6/
6 ;
n
I I I I
I
\VI
',~:, I I vi , ,_) I
1?
I I
1, I
\~JY
ITEM
NO
GD 23
1 FU LL HEIGHT WALL 25
\ 46 lb 51 'i?
([53 le-------------------~e--41
EQUIPMENT SCHEDULE
QTY EQUIPMENT DESCRIPTION
5 SHELVING, DRY STORAGE
2 DUNNAGE RACK
1 JANITOR SHELF WITH MOP RACK
1 MOP SINK
1 OFFICE FURNITURE
1 ROLL DOWN COUNTER DOOR
2 SHELVING, PAN STORAGE
1 HOOD CONTROL PANEL
1 HAND SINK
1 WORK TABLE
1 PASS THROUGH SHELF
1 REFRIGERATOR, REACH-IN
1 HOLDING CABINET, HUMIDIFIED HEATED
1 SHELVING, PAN STORAGE
1 TILT SKILLET, ELECTRIC
1 FLOOR TROUGH
1 BURNER/GRIDDLE RANGE, ELECTRIC
1 OVEN-STEAMER, COMBINATION, ELECTRIC
1 SKILLET & POT FILLER STATION
1 EXHAUST HOOD, CLASS ONE
1 WALL FLASHING, STAINLESS STEEL
1 FIRE SUPPRESSION SYSTEM
1 WATER FILTER SYSTEM, COMBI
- SPARE NUMBER
1 SOILED DISH TABLE
1 SLANT RACK SHELF
1 PRE-RINSE FAUCET
1 WAREWASHER, DOOR TYPE, HIGH TEMP
2 GREASE INTERCEPTOR
1 CLEAN DISH TABLE
1 SHELF, WALL MOUNT
- SPARE NUMBER
1 ICE MAKER, UNDERCOUNTER W/BIN
1 WATER FILTER SYSTEM, ICE MACHINE
- SPARE NUMBER
- SPARE NUMBER
1 FREEZER, WALK-IN
1 COOLER, WALK-IN
8 SHELVING, COLD STORAGE
1 FREEZER REFRIGERATION SYSTEM
1 COOLER REFRIGERATION SYSTEM
- SPARE NUMBER
1 POT SINK, THREE COMPARTMENT
1 PASS OVER SHELF WITH UTENSIL RACK
- SPARE NUMBER
1 CAN OPENER
1 PREPARATION TABLE WITH SINKS
4 TRASH CAN, 32 GALLON
1 WORK TABLE
1 SHELF, WALL MOUNT
1 HAND SINK
1 FIRE EXTINl-:1 IISHER, K-CLASS
1 FREEZER, REACH-IN )
-;3\
FOR
CONSTRUCTION
mi
HOOD #20
PLAN VIEW
HOOD #20
ELEVATION VIEW
HOOD #20
SECTION VIEW
EX
H
AU
ST
.H O
O D
EQ
U
IP
M
EN
T
FO
O
D .S
ER
VI
C E
TF
A
TF
A
TF
A
K-400
SO
LI
C
IT
AT
IO
N N
O
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
IS
SU
E D
AT
E:
SI
ZE
C H
EC
KE
D B
Y:
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
SHEET ID
D
AT
E
FA
IR
BA
N
KS
, A
LA
SK
A
(9
) 4
-1
| A
EC
C
C O
LL
EG
E R
O
AD
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
AL
AS
KA
D
IS
TR
IC
T
EI
EL
SO
N
A
IR
F O
R C
E
BA
SE
, A
LA
SK
A
EI
E3
S C
H O
O L
AG
E
SE
R
VI
C
ES
D
P6
C O
N
SO
LI
D
AT
ED
D
ES
IG
N
C O
M
PL
ET
E
AN
SI
D
F
EB
W
1K B-
-R
-0
W
1K B-
-C
-0
US Army Corps Of Engineers ®
D
ES
IG
N
A
LA
SK
A
FA
IR
BA
N
KS
, A
K
(9
) 4
-5
S C
H
AC
H T
ST
R
EE
T
G H
EM
M
C O
M
PA
N Y, IN
C
-4--
EXH
1--------72------------j i L
7'-8"
AT L-M DUTY
EXH
,__--27---, C
4'-4"
AT MED DUTY
12--+--------------------12'-o"-------------------, ,__---------------------13•-o·------------------..., RHANG
OOKING-
MIN. OVE
TO C
EOU IPMENT
L
I
67.25 n r
I 0
[o~]
J.J I
2 I
C l/2W (1)
= = I I @ D@ n n 12'-o"
33.231 - - - -- - -
(6) (7) (8) (9)
H 9', !a .!F
'lo if p
11 IL
u '=9 -
OVE
RRIDE
TON BUT
(TYP )
MIN. 0 VERHANG
OKING -TO CO
SURFA CE
HOOD INFORMATION
MAXIMUM SIZE
AIR FLOW REQUIREMENTS
APPROX.
ITEM MODEL S.P. TEST DUCT COLLAR WEIGHT
NO. PORT DUCT DUCT S.P. CFM SIZE (LBS) L (in) D (in) H (in) ("W.G.) TYPE QTY ("W.G.) (EACH) L (in) D (in)
20 ELX
TOTAL HOOD S.P.: 1.07
TOTAL EXHAUST: 3371
TOTAL SUPPLY: 0
"CAPTURE WALL"
BY GAYLORD
156 72
DETAIL 3
s'-o"
FIN. CEILING 6'-8"
(VERIFY) MTG. HT.
38 0.55 EXH 1 1.07 3371 27 12 1180
APPROX. TOTAL WEIGHT: 1420
MTG. BRACKET
BY GAYLORD
MOUNTING RODS BY
VENTILATOR INSTALLER
1.375
1.0 2.0
FASTEN TO STRUCTURAL
WALL USING #10 SCREW
(MIN.) BY VENTILATOR
INSTALLER
TOP OF....,__
VENTILATOR
DETAIL
FASTEN TO WALL
BY VENTILATOR
2 1NSTALLER
INTIERMIITTNTL Y
WELDED "CAPTURE
WALL" ATTACHMENT
FLANGE
SCREW BY
GAYLORD
"CAPTURE WALL"
&: CAGE NUT
BY GAYLORD
"CAPTURE WALL"
INSTALLED IN FIELD
BY VENTILATOR INSTALLER DETAIL 1
1---------72---------f) 6" CLEARANCE TO COMBUSTIBLES WITH L FIRE INSULATION BLANKETl ON ROOF
S/S QUA
B
BOTTOM OF
HOOD APRON
BOTTOM
VENTILATOR
FLANGE BY
GAYLORD
FASTIEN TO
STRUCTURAL
WALL BY
VENTILATOR
INSTALLER
DETAIL 2
DETAIL 1
APTURE WALL"
BY GAYLORD
J
DETAIL 3
VENTILATOR NOTES
(NON-WATER WASH)
A) VERIFY ALL MAKES AND MODELS OF COOKING
EQUIPMENT AND LOCATION IN RELATION TO VEN Tl LA TOR
PRIOR TO FABRICATION.
B) FRONT AND REAR MOUNTING BRACKETS HAVE
,□.625" HOLES. BRACKETS TO BE SUPPORTIED WITHIN
12" OF EACH END OF EACH SECTION, WITH A MAXIMUM
SPAN Of 72" BETWEEN SUPPORTS.
C) INTIERIOR MOUNTING BRACKET(S) TO BE SUPPORTIED
WITHIN 36" OF EACH END OF EACH SECTION, WITH A
MAXIMUM SPAN OF 72" BETWEEN SUPPORTS.
LIGHTING NOTE
THIS LIGHTING IN THIS VENTILATOR IS DESIGNED TO PR0\1DE
50 FOOT CANDLES OF LIGHT AT THE COOKING SURF ACE, IF
50 FOOT CANDLES OF LIGHTING IS PR0\1DED IN THE
SURROUNDING SPACE.
THESE LED FIXTURES ARE PR0\1DED WITH LED SMD CHIPS
INTIEGRA TIED INTO THE FIXTURE ASSEMBLY, THEREFORE NO
SEPARATIE BULBS ARE REQUIRED.
ELECTRICAL NOTES
(DCV-AV)
CD (1) CAT 5 CABLE, FOR CONTROL(S), IN FLEXIBLE
CONDUIT, EXTIENDING 6' BEYOND END Of VEN Tl LA TOR
BY GAYLORD. WIRED TO DCV CONTROL CABINET OR
NEXT HOOD (IF APPLICABLE) BY ELECTRICAL
CONTRACTOR.
* LIGHT FIXTURES, VAPOR PROOF, U.L. LISTED,
FURNISHED, INSTALLED AND \\IRED BY GAYLORD. *
@ (2) \\IRES AND GROUND, FOR CONTROL(S) AND
LIGHT(S), IN FLEXIBLE CONDUIT, EXTIENDING 6'
BEYOND END OF VEN TI LA TOR BY GAYLORD. 111RED
TO SUPPLY VOLTAGE BY ELECTRICAL CONTRACTOR.
VERIFY CEILING
CONDITIONS
EXACT FLOOR TO STRUCTURAL CEILING AND FLOOR TO
FINISH CEILING HEIGHTS MUST BE VERIFIED FOR
VENTILATOR DESIGN. INCORRECT HEIGHTS MAY CAUSE THE
VENTILATOR TO NOT FIT PROPERLY OR COMPLY WITH
CLEARANCES SPECIFIED IN APPLICABLE CODES AND
STANDARDS. CAUTION: IF THE FINISHED CEILING IS
HIGHER THAN THE TOP OF THE VENTILATOR, ENCLOSURE
PANELS MAY BE REQUIRED.
FLOOR TO STRUCTURAL CEILING: (VERIFY)
FLOOR TO FINISH CEILING: 8'-0"
"CAPTURE WALL"
INSTALLATION DETAILS
1) INSTALL VENTILATOR.
2) REMOVE 2•,4• SHIPPING BLOCK FROM BOTTOM OF
VEN Tl LA TOR.
3) SECURE BOTTOM VENTILATOR FLANGE TO
STRUCTURAL WALL USING #10 SCREWS (MIN.) ON A
MAXIMUM Of 32" CENTIERS. (SEE DETAIL #1)
4) ATTACH "CAPTURE WALL" TO VENTILATOR
USING SCREWS AND CAGE NUTS PROv1DED AT
PRE-DRILLED LOCATIONS.
5) SECURE BOTTOM OF 'CAPTURE WALL" TO STRUCTURAL
WALL USING #10 SCREWS (MIN.) ON A MAXIMUM OF 32"
CENTERS. (SEE DETAIL #3)
6) IF LOCAL ..URISDICTION ALLOWS:
INSTALLER TO APPLY SILICONE CAULK ON ALL JOINTS
CONNECTING TO BUILDING WALL ANO VERTICAL SEAMS
(IF APPLICABLE).
FIRE PROTECTION
SYSTEM NOTES
ANSUL R-102-ASE
FP-1) LOCATION OF FIRE PROTIECTION NOZZLES MUST BE
VERIFIED IN RELATION TO THE COCKING
EQUIPMENT, PRIOR TO VEN Tl LA TOR FABRICATION.
COMPLETIE SYSTIEM INCWDING APPLIANCE DROPS AND
SURFACE MOUNTIE□ DETIECTION BRACKETS BY GAYLORD,
WITH FIELD INSTALLATION BY FIRE SYSTIEM CONTRACTOR.
ANSUL FIRE SYSTIEM FACTORY PRE-PIPED CHEMICAL LINES
INCLUDING DUCT, PLENUM AND APPLIANCE DROPS WITH
ALL NOZZLES INSTALLED PER COOKING EQUIPMENT
ARRANGEMENT ON GAYLORD APPROVED DRAWINGS. ALL
EXPOSED CHEMICAL PIPING CHROME PLATIED OR CHROME
SLEEVED. INCLUDES FACTORY PRE-PIPED DETIECTION
LINES 111TH SURFACE MOUNTIED DETIECTOR BRACKETS.
INSTALLATION BY CERTIFIED FACTORY INSTALLERS.
l~QLUOES·
• TANK(S) AND RELEASE ASSEMBLY(S)
• CHEMICAL
• DETIECTOR CABLE
• FUSIBLE LINKS 111TH LINKAGE
• (I) REMOTIE MANUAL PULL STATION
TO DETIERMINE IF PROv1DED BY GAYLORD.
• (I) MANUAL RESET RELAY PER FIRE SYSTIEM,
IF REQUIRED
• PIPING, CHROME SLEEVE, ELBOWS, AND NOZZLES FOR
ANY NOZZLES THAT ARE DISCONNECTIED FOR
SHIPMENT
EBQl!IQEQ BY SBE SYS!EM QQ~JBA!JQB·
• PLANS AND PERMITS
• PREVAILING WAGE
• EXPELLANT GAS CARTRIDGE(S)
• PARTS AND INSTALLATION OF CHEMICAL AND
DETIECTION LINES FROM TANK(S) TO CONNECTION
POINTS ON HOOD
' AIMING Of NOZZLES
• INSTALLATION OF NOZZLES DISCONNECTIED FOR
SHIPMENT
• INSTALLATION OF TANKS AND RELATIED COMPONENTS
• INSTALLATION OF DETIECTOR CABLE AND FUSIBLE
LINKS
• INSTALLATION OF REMOTIE MANUAL PULL STATION
• TRIP TIEST AND CERTIFICATION
• HANDHELD FIRE EXTINGUISHER
• INSPECTION AND SERv1CING
FIRE PROTECTION
INLET NOTES
I IS THE ANSUL FUSE LINK DETIECTOR CABLE INLET.
IS THE ANSUL CHEMICAL TANK INLET.
• SEE ANSUL TANK DIAGRAM FOR DETAILS •
FOR
CONSTRUCTION
| ftqw_vault7_2202_2225_487 (1) |
| ftqw_vault7_2202_2225_488 (1) |
| ftqw_vault7_2202_2225_491 (1) |
| K-100 |
| K-400 |
| PN 9181-03 A-110 Floor Plan Overall |
| PN 9181-03 A-112 Floor Plan Sector 2 |
| PN 9181-03 A-113 Floor Plan Sector 3 |
| PN 9181-03 A-114 Floor Plan Sector 4 |
File details come from the government source that posted it. Updated .