BASE MAP
RICHARDSON HWY
1200 600 0 1200 2400 3600
SCALE IN FEET
PROJECT
LOCATION
BLDG 1346
F-35 TEMPORARY SOUTH GATE
ACCESS FOR CONSTRUCTION
H
AU
L R O
U
TE
1 View Name 1/8" = 1'-0"A101
Room name
LEGEND
NAME
NUMBER
SHEET LOCATION
SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
SEE DISCIPLINES FOR SPECIFIC SYMBOLS
---SHEET LOCATION
DETAIL NUMBER
---SHEET LOCATION
DETAIL NUMBER
CODE SUMMARY
GOVERNING CODES:
2015 INTERNATIONAL BUILDING CODE - IBC
2015 INTERNATIONAL FIRE CODE - IFC
2015 NFPA 101 - LIFE SAFETY CODE
2017 NFPA 70 - NATIONAL ELECTRICAL CODE - NEC
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (CHANGE 1, 28 NOV 2016)
UFC 1-200-01 GENERAL BUILDING REQUIREMENTS (20 JUN 2016)
AUTHORITY HAVING JURISDICTION
EIELSON AFB
LIQUID PENETRATE
ROOM 110:
FLUORESCENT PENETRANTS AND HYDROPHILIC EMULSIFIER ARE CALCULATED AS
COMBUSTIBLE LIQUIDS, CLASS IIIB PER IBC 2015. QUANTITIES IN OPEN USE IN FACILITY
DO NOT EXCEED TABLE 307.1(1). ROOM DOES NOT REQUIRE FIRE SEPARATION.
OCCUPANCY
NO CHANGE IN OCCUPANCY
BUILDING SHALL BE OCCUPIED DURING CONSTRUCTION
PROJECT SITE
FLIG
H
T LIN
E AVE
IN
N
ER
LO
O P
PROJECT
LOCATION
BLDG 1346
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
1/3/2019 5:04:41 PM
GENERAL IN FORMATI ON
G
ARCHITECTURAL
A001 ARCHITECTURAL INFORMATION
A100 OVERALL DEMOLITION PLAN
A200 OVERALL RENOVATION PLAN
A500 EXTERIOR DETAILS
A600 REFLECTED CEILING PLAN
A800 INTERIOR ASSEMBLY TYPES AND DETAILS
A900 ROOM, MATERIAL, AND DOOR SCHEDULES
GENERAL
G001 GENERAL INFORMATION
ELECTRICAL
E001 ELECTRICAL LEGEND AND SCHEDULES
E002 ELECTRICAL DEMOLITION PLANS
E003 ELECTRICAL PLANS
DRAWING INDEX
REF. # SHEET TITLE
ENGINE MAINTENANCE FACILITY BLDG 1346
PROJECT NO. FTQW 18-0203
FIRE PROTECTION
F100 FIRE PROTECTION FIRST FLOOR PLAN
F101 FIRE PROTECTION PLANS AND DETAILS
F102 FIRE SUPPRESSION SCHEMATIC
MECHANICAL
M001 ABBREVIATIONS AND SCHEDULES
M101 DEMOLITION PLANS
M201 MECHANICAL PLANS
M202 MECHANICAL DETAILS
CONTRACTOR LAYDOWN AREA TO BE COORDINATED WITH GOVERNMENT AFTER AWARD.
LAYDOWN AREA
CONCRETE
EARTH
GYPSUM
RIGID INSULATION
MASONRY CONCRETE
PLYWOOD
MATERIAL LEGEND
BATT INSULATION
MASONRY BRICK
EXISTING
CONSTRUCTION
TEMPORARY
CONSTRUCTION
RIGID MINERAL FIBER
BATT/BLOWN INSULATION
ARCHITECTURAL SYMBOL LEGEND
150 SF
Room Name
DETAIL NAME
DETAIL NUMBER
SHEET LOCATION
DETAIL SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
DETAIL NUMBER
SHEET LOCATION
SIMILAR
REVISION
SPOT ELEVATION
SEE OTHER DISCIPLINES FOR ADDITIONAL SYMBOLS
KEYED NOTE
DOOR TAG
A100
A100
EXTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
INTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
DETAIL NUMBER 4
1t
BUILDING SECTION
DETAIL NUMBER
SHEET LOCATION
SIMILAR
WALL SECTION
WINDOW TYPE
ROOM AREA
1/8" = 1'-0"A101 View Name
1/4" / 1'-0"
.SPOT SLOPE
101ROOM NUMBER
A
A101
SIM
A101
SIM
101A
SEE OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS.
SOME ABBREVIATIONS MAY NOT BE USED IN THIS PROJECT.
(E) EXISTING
ACT ACOUSTICAL CEILING TILE
ADA AMERICAN DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
ELEC ELECTRICAL
FRP FIBERGLASS REINFORCED PANEL
GYP GYPSUM BOARD
HM HOLLOW METAL
IBC INTERNATIONAL BUILDING CODE
INHM INSULATED HOLLOW METAL
INSUL INSULATION
ITSP INSULATED TRANSLUCENT SANDWICH PANEL
MAX MAXIMUM
MECH MECHANICAL
MFSD MANUFACTURER'S STANDARD
MIN MINIMUM
NIC NOT IN CONTRACT
OC ON CENTER
OD OVERFLOW DRAIN
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OSB ORIENTED STRAND BOARD
PLAM PLASTIC LAMINATES
PLY PLYWOOD
RD ROOF DRAIN
SIP STRUCTURAL INSULATED PANEL
SPEC SPECIFICATION
STC SOUND TRANSMISSION CLASS
STRUC STRUCTURAL
SV STAIN/VARNISH
TYP TYPICAL
UL UNDERWRITERS LABORATORY
VCT VINYL COMPOSITION TILE
VTR VENT THROUGH ROOF
ARCHITECTURAL STANDARD ABBREVIATIONS
ARCHITECTURAL PROJECT SPECIFIC ABBREVIATIONS
NA NOT APPLICABLE
WX-3A
WALL ASSEMBLY CATEGORY - FUNCTION
WALL FRAMING MEMBER SIZE
WALL ASSEMBLY MODIFIER
WALL ASSEMBLY CATEGORY - FUNCTION
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
WF WALL - FOUNDATION
WR WALL - RETAINING
WX WALL - EXTERIOR
WALL FRAMING MEMBER SIZE
ASSEMBLIES MAY NOT INCLUDE A FRAMING MEMBER SIZE.
FURRING AND METAL STUDS
0 7/8" FURRING CHANNELS
1 1 5/8" METAL STUDS
2 2 1/2" METAL STUDS
3 3 5/8" METAL STUDS
4 4" METAL STUDS
6 6" METAL STUDS
8 8" METAL STUDS
SHAFT WALLS
2 2 1/2" METAL CH STUDS
4 4" METAL CH STUDS
6 4" METAL CH STUDS
WOOD STUDS
4 2x4 WOOD STUDS 6 2x6 WOOD STUDS 8 2x8 WOOD STUDS
CMU
2 1 5/8" CMU
4 3 5/8" CMU
6 5 5/8" CMU
8 7 5/8" CMU
10 9 5/8" CMU
12 11 5/8" CMU
CONCRETE
# CONCRETE THICKNESS
WALL ASSEMBLY MODIFIER
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
A TYPICAL
F FIRE RATED
ASSEMBLY TAG LEGEND - WALL EXTERIOR
C-A1
CEILING ASSEMBLY CATEGORY
CEILING ASSEMBLY MODIFIER
CEILING ASSEMBLY CATEGORY
C CEILING
CEILING MATERIAL DESIGNATION
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED
EXAMPLES.
A ACOUSTIC CEILING TILE
G GYPSUM BOARD
S SPECIALTY MATERIAL
CEILING ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
1 TYPICAL
ASSEMBLY TAG LEGEND - CEILING
CEILING MATERIAL DESIGNATION
F-W1
FLOOR ASSEMBLY CATEGORY - FUNCTION
FLOOR ASSEMBLY MODIFIER
FLOOR ASSEMBLY CATEGORY - FUNCTION
FLOORS ON GRADE OR THOSE COMPRISING THE EXTERIOR
ENVELOPE OF THE BUILDING ARE CONSIDERED EXTERIOR.
F FLOOR - INTERIOR
FX FLOOR - EXTERIOR
FLOOR MATERIAL DESIGNATION
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED
EXAMPLES.
C CONCRETE
W WOOD
FLOOR ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
1 TYPICAL
ASSEMBLY TAG LEGEND - FLOOR
FLOOR MATERIAL DESIGNATION
W01-3A
WALL ASSEMBLY CATEGORY - FUNCTION
WALL SHEATHING DESIGNATION
WALL FRAMING MEMBER SIZE
WALL ASSEMBLY MODIFIER
WALL ASSEMBLY CATEGORY - FUNCTION
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
W WALL - INTERIOR
WALL SHEATHING DESIGNATION
ASSEMBLIES MAY NOT INCLUDE A SHEATHING DESIGNATION.
THE SHEATHING DESIGNATION REFERS TO THE NUMBER OF
SHEATHING LAYERS ON EACH SIDE OF THE FRAMING MEMBER.
00 FIRST SIDE (0 LAYERS) + SECOND SIDE (0 LAYERS)
01 FIRST SIDE (0 LAYERS) + SECOND SIDE (1 LAYERS)
02 FIRST SIDE (0 LAYERS) + SECOND SIDE (2 LAYERS)
03 FIRST SIDE (0 LAYERS) + SECOND SIDE (3 LAYERS)
04 FIRST SIDE (0 LAYERS) + SECOND SIDE (4 LAYERS)
11 FIRST SIDE (1 LAYERS) + SECOND SIDE (1 LAYERS)
12 FIRST SIDE (1 LAYERS) + SECOND SIDE (2 LAYERS)
13 FIRST SIDE (1 LAYERS) + SECOND SIDE (3 LAYERS)
14 FIRST SIDE (1 LAYERS) + SECOND SIDE (4 LAYERS)
22 FIRST SIDE (2 LAYERS) + SECOND SIDE (2 LAYERS)
23 FIRST SIDE (2 LAYERS) + SECOND SIDE (3 LAYERS)
24 FIRST SIDE (2 LAYERS) + SECOND SIDE (4 LAYERS)
33 FIRST SIDE (3 LAYERS) + SECOND SIDE (3 LAYERS)
34 FIRST SIDE (3 LAYERS) + SECOND SIDE (4 LAYERS)
44 FIRST SIDE (4 LAYERS) + SECOND SIDE (4 LAYERS)
WALL FRAMING MEMBER SIZE
FURRING AND METAL STUDS
0 7/8" FURRING CHANNELS
1 1 5/8" METAL STUDS
2 2 1/2" METAL STUDS
3 3 5/8" METAL STUDS
4 4" METAL STUDS
6 6" METAL STUDS
8 8" METAL STUDS
SHAFT WALLS
2 2 1/2" METAL CH STUDS
4 4" METAL CH STUDS
6 4" METAL CH STUDS
WOOD STUDS
4 2x4 WOOD STUDS 6 2x6 WOOD STUDS 8 2x8 WOOD STUDS
CMU
2 1 5/8" CMU
4 3 5/8" CMU
6 5 5/8" CMU
8 7 5/8" CMU
10 9 5/8" CMU
12 11 5/8" CMU
CONCRETE
# CONCRETE THICKNESS
WALL ASSEMBLY MODIFIER
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
A TYPICAL
F FIRE RATED
G FIRE AND SOUND RATED
H FIRE AND SOUND RATED WITH TILE
K TILE
L TILE AND SOUND RATED
P PLYWOOD
S SOUND RATED
W WOOD STUD
X WOOD STUD, FIRE RATED
Y WOOD STUD, FIRE AND SOUND RATED
Z WOOD STUD, SOUND RATED
LETTERS AA THRU ZZ REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES FOR CHASE WALLS. THE BELOW ARE
COMMONLY USED EXAMPLES.
FF FIRE RATED
GG FIRE AND SOUND RATED
HH FIRE AND SOUND RATED WITH TILE
LL TILE AND SOUND RATED
SS SOUND RATED
XX WOOD STUD, FIRE RATED
YY WOOD STUD, FIRE AND SOUND RATED
ZZ WOOD STUD, SOUND RATED
ASSEMBLY TAG LEGEND - WALL INTERIOR
A.
B.
C.
D.
E.
F.
G.
H.
I.
SEE G1 SHEETS FOR GENERAL CODE ANALYSIS.
COORDINATE ARCHITECTURAL WORK WITH CIVIL,
STRUCTURAL, MECHANICAL, ELECTRICAL, AND OTHER
DISCIPLINES.
SEE STRUCTURAL FOR SPECIFIC INFORMATION
REGARDING LOAD BEARING MEMBERS, MECHANICAL
FASTENERS, AND MASTIC ADHESION.
FIELD VERIFY DIMENSIONS SHOWN TO EXISTING
CONSTRUCTION. NOTIFY ARCHITECT WHERE
DISCREPANCIES AFFECT DESIGN.
DIMENSIONS AT EXISTING CONSTRUCTION ARE
MEASURED FROM FACE OF EXISTING FINISH UNLESS
NOTED OTHERWISE.
DIMENSIONS AT NEW CONSTRUCTION ARE MEASURED
FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.
DIMENSIONS INDICATED AS 'CLEAR' REQUIRE CLEARANCE
MEASURED TO FINISHED FACES.
FURNITURE IS SHOWN FOR COORDINATION PURPOSES
ONLY. FURNITURE IS OWNER FURNISHED AND OWNER
INSTALLED UNLESS NOTED OTHERWISE.
PATCH, REPAIR, AND REFINISH EXISTING SURFACES TO
REMAIN, AFFECTED BY WORK.
ARCHITECTURAL NOTES
THIS REFERENCE IS INTENDED TO ASSIST WITH THE
LOCATION OF INFORMATION IN A TYPICAL PROJECT. THIS
PROJECT MAY VARY FROM THE REPRESENTATION BELOW.
SEE THE SHEET INDEX FOR SPECIFIC SHEET SEQUENCE.
A0 SHEETS ARCHITECTURAL INFORMATION
A1 SHEETS ARCHITECTURAL DEMOLITION
A2 SHEETS FLOOR AND ROOF PLANS
A3 SHEETS EXTERIOR ELEVATIONS
A4 SHEETS SECTIONS AND VERTICAL CIRCULATION
A5 SHEETS EXTERIOR DETAILS
A6 SHEETS INTERIOR PLANS
A7 SHEETS INTERIOR ELEVATIONS
A8 SHEETS INTERIOR DETAILS
A9 SHEETS SCHEDULES
ARCHITECTURAL SHEET SEQUENCE AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:38 PM
JB
ARCHI TECTURAL I N FORMAT ION
A
J B
CHEMICAL
STORAGE
LIQUID
PENETRANT
BEARING
CLEANING
WASH
RACK
CKT
ROOM
OIL
ANALYSIS
ROOM
XRAY
ROOM
DARKROOM
XRAY
VAULT
TRAINING ROOM
1 2
STORAGE
MECHANICAL
CONTRACTOR WORK AREA
9' -9
11'-9 5/8"
SIM
CONTRACTOR
WORK AREA
'-0
27'-0"
'-5
A.
B.
C.
D.
PROVIDE DEMOLITION REQUIRED TO ACCOMMODATE NEW
WORK.
SEE ELECTRICAL AND MECHANICAL DOCUMENTS FOR
ADDITIONAL DEMOLITION REQUIREMENTS.
EXISTING STRUCTURAL SYSTEMS INCLUDING COLUMNS,
BEAMS, AND STRUCTURAL WALLS TO REMAIN.
GOVERNMENT TO REMOVE EQUIPMENT PRIOR TO START OF
WORK.
DEMOLITION NOTES
DEMOLITION LEGEND
EXISTING CONSTRUCTION
EXISTING WALL TO REMAIN
DEMOLISH DOOR, WALL TO REMAIN
DEMOLISH WALL AND DOOR
COMPUTER
ROOM
SECTION
OFFICE
BREAK
ROOM
EQUIPMENT
PLATFORM
KEYNOTES
REMOVE EXISTING WALL GYPSUM BOARD AT WALLS AS
REQUIRED TO ACCOMMODATE CEILING WORK.
REMOVE GYPSUM BOARD LID.
REMOVE GYPSUM BOARD SUSPENDED CEILING. REMOVE
MECHANICAL AND ELECTRICAL CEILING MOUNTED ITEMS
AND SALVAGE FOR REINSTALLATION. PROVIDE
TEMPORARY SUPPORT FOR ITEMS THAT ARE REQUIRED
TO REMAIN.
REMOVE LEAD LINED SLIDING DOOR, FRAME AND
HARDWARE. SALVAGE DOOR MONITORING SYSTEM FOR
REINSTALLATION.
CONTRACTOR SHALL MAINTAIN ACCESS TO ROOM. ROOM
SHALL BE IN USE FOR DURATION OF CONSTRUCTION.
EXISTING DOOR AND FRAME TO REMAIN. REMOVE FIRE
RATING PLATES FROM DOOR AND FRAME.
MODIFY WALL AS REQUIRED TO ACCOMMODATE WORK.
PREPARE EXISTING GYPSUM CEILING TO RECEIVE NEW
FINISH AS SCHEDULED.
PROVIDE TEMPORARY POLYETHYLENE DUST AND DEBRIS
BARRIER TO 10'-0" AFF. BARRIER CONSTRUCTION TO
ALLOW PASSAGE FOR SIX PASSENGER TRUCK AND
ENGINE ON A TRAILER. REMOVE AT COMPLETION OF
WORK.
REMOVE DOOR AND FRAME (LEAD LINED).
REMOVE EXISTING CONCRETE SLAB. SEE 5/A800 FOR
EXCAVATION AND REPLACEMENT SLAB DETAILS.
MAINTAIN DRIVE LANE TO ALLOW PASSAGE FOR SIX
PASSENGER TRUCK AND ENGINE ON A TRAILER.
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:41 PM
JB
OVERAL L DEMOL IT ION PL AN
A
LSM
1/8" = 1'-0"A100
1 DEMOLITION PLAN - 1ST FLOOR
1/8" = 1'-0"A100
2 DEMOLITION PLAN - 2ND FLOOR
KEYPLAN
XRAY
VAULT
CHEMICAL
STORAGE
LIQUID
PENETRANT
BEARING
CLEANING
CKT
ROOM
21 DARK
ROOM
OIL
ANALYSIS
ROOM
WASH
RACK
MECHANICAL
TRAINING
ROOM
25A
16'-0"
'-4
/8
XRAY
ROOM
STORAGE
FIRE
PUMP
W11-6F
9' -1
1/
4"
12'-4 1/4"
119A
9 23A
A500
8'-0"
5' -0
W11-6F
A800
A800
SIM
CONTRACTOR
WORK AREA
W11-6A
A200
CONTRACTOR WORK AREA
SIMW11-6A
SECTION
CHIEF
OFFICE
BREAK
ROOM
EQUIPMENT
PLATFORM
COMPUTER
ROOM
KEYNOTES
PROVIDE LEAD LINED GYPSUM BOARD AND LEAD LINED
WRAP AT WALL AS REQUIRED TO PROVIDE CONTINUOUS
BARRIER FROM FLOOR TO CEILING. SEE 1/A800 FOR WALL
TO CEILING JOINT DETAIL.
PROVIDE 8 LB, 1/8" LEAD SHIELDING WITH ALL
PENETRATIONS, DOOR JAMBS, AND THRESHOLDS/ SWEEPS
SHIELDED TO THE SAME LEVEL. THE LEAD OVERLAP MUST
BE IN THE SAME PLANE AS THE SHIELDING IN THE DOOR.
SEE A800.
PROVIDE 8 LB, 1/8" LEAD LINED GYPSUM BOARD WITH ALL
PENETRATIONS AND OVERLAP SHIELDED TO THE SAME
LEVEL STARTING AT 4'-0" ABOVE FLOOR LEVEL TO THE
CEILING. SEE 1/A800 FOR WALL TO CEILING JOINT DETAIL.
REINSTALL SALVAGED MECHANICAL AND ELECTRICAL
CEILING MOUNTED ITEMS.
PATCH WALL AT AREA OF DESTRUCTIVE TESTING, ± 9'-0"
AFF.
EXISTING HAND/GUARD RAIL TO REMAIN.
CONCRETE LANDING.
PROVIDE WORDS 'NO STORAGE ABOVE' HELVETICA FONT 4"
HEIGHT MINIMUM AT 10'-0" AFF.
PROVIDE DOOR AND FRAME. THIS DOOR WILL REQUIRE 3
LB, 3/32" LEAD INSIDE OF THE DOOR AND INSIDE OF THE
DOOR JAMB WITH OVERLAP BETWEEN THE DOOR AND THE
JAMB, SEE A800.
DUST AND DEBRIS BARRIER, SEE A100.
PROVIDE 2 LB, 1/32" LEAD SHIELDING AT ALL
PENETRATIONS AND OVERLAP SHIELDED TO THE SAME
LEVEL. AT THE UPPER PORTION OF THIS WALL, THE 8 LB,
1/8" LEAD MUST INTEGRATE AND OVERLAP WITH THE 1/32"
LEAD DOWN 1'-0" FROM THE CEILING. SEE 1/A800 FOR WALL
TO CEILING JOINT DETAIL.
MAINTAIN DRIVE LANE. SEE A100.
LEGEND
EXISTING CONSTRUCTION
1-HOUR FIRE RATED
RENOVATION NOTES
1. SEE A800 FOR SEALING PENETRATIONS THROUGH LEAD-
LINED GYPSUM BOARD.
KEEP AREA CLEAR
4" 4"
2"
BLACK
CAUTION YELLOW
HELVETICA FONT
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/10/2019 9:06:50 AM
JB
OVERAL L RENOVAT ION P L AN
A
LSM
1/8" = 1'-0"A200
1 OVERALL PLAN - 1ST FLOOR
1/8" = 1'-0"A200
2 OVERALL PLAN - 2ND FLOOR
KEYPLAN
1/2" = 1'-0"A200 REFERENCE: 1/ A200
3 INTERIOR PLAN DETAIL - CLEAR AREA WARNING
A.
B.
C.
D.
E.
F.
G.
1 - TYPICAL
ASSEMBLIES ARE DIAGRAMS ONLY, DO NOT SCALE.
ASSEMBLIES ARE INTENDED TO DESCRIBE MATERIALS AND
THEIR RELATIONSHIP WITHIN A GIVEN CEILING, FLOOR,
ROOF, OR WALL. PENETRATIONS, JOINTS, FINISHES, AND
INTERSECTIONS BETWEEN ASSEMBLIES ARE NOT SHOWN.
SEE A0 SHEETS FOR ARCHITECTURAL NOTES, SHEET
SEQUENCE, AND ASSEMBLY TAG LEGENDS.
SEE A2 SHEETS FOR FLOOR PLAN ASSEMBLY LOCATIONS.
SEE A5 SHEETS FOR EXTERIOR DETAILS.
SEE A8 SHEETS FOR INTERIOR ASSEMBLIES, INTERIOR
ASSEMBLY NOTES, AND INTERIOR DETAILS.
SEE A9 SHEETS FOR ROOM SCHEDULE CEILING ASSEMBLY
LOCATIONS.
EXTERIOR ASSEMBLY NOTES
INTERIOREXTERIOR
CONTINUOUS SEALANT AND BACKER ROD
ENTIRE PERIMETER
DUCT AND HOOD PER MECHANICAL
PRE-FINISHED METAL
FLASHING WITH DRIP EDGE
6" METAL STUD FRAMING SIMILAR TO 2/A500,
BOX HEADERS NOT REQUIRED
FILL SHIM SPACE WITH SPRAY FOAM
(SIMILAR AT JAMBS)
DOOR
ROUGH
OPENING
6" INSULATED BOX HEADER
(E) 8" ZEE GIRT
(E) 8" ZEE GIRT (E) 8" ZEE GIRT
(2) 600S162-54 WELDED KING STUD
FILLED WITH BATT INSULATION SIMPSON SSC4.25 CLIPS,
TYPICAL. CUT EXPOSED
FASTENER ENDS FLUSH
3/8" ⌀ CONCRETE
SCREW, 4" EMBED
~NEW SLAB~
A500
A500
A500
A500
OPP
HAND
EXISTING ASPHALT
TO REMAIN
TOP OF STEM WALL
FI
E
LD
V
E R
IF
Y
/4
FI
E
LD
V
E R
IF
Y
/4
INTERIOREXTERIOR
EXISTING 8" GIRT
6" METAL STUD
BOX HEADER WITH
BATT INSULATION
PRE-FINISHED
METAL FLASHING
WITH DRIP EDGE
CONTINUOUS
SEALANT AND BACKER
ROD EACH SIDE
DOOR AND FRAME PER
DOOR SCHEDULE
FILL SHIM SPACE WITH
SPRAY FOAM
PROVIDE BATT
INSULATION
FILL VOID WITH
BATT INSULATION
FILL DOOR FRAME
WITH SPRAY FOAM
SELF EXTINGUISHING
VAPOR RETARDER
FABRIC LINER AS IT
COMPLIES WITH: ASTM
1136, TYPES I THROUGH
VI; NFPA 701 LARGE
SCALE; FLAME SPREAD
OF 25 OR LESS PER ASTM
E-84 (EQUIVALENT TO
NFPA 255, ANSI 2.5 OR
UL/ULC 723)
TERMINATION
BAR PERIMETER
OF OPENING
SEAL NEW VAPOR
RETARDER ON TO
EXISTING MINIMUM
OVERLAP 4"
INTERIOR
EXTERIOR
EXISTING 8" GIRT
WELDED KING STUD
WITH BATT INSULATION
PRE-FINISHED METAL FLASHING
WITH DRIP EDGE
CONTINUOUS SEALANT AND
BACKER ROD EACH SIDE
DOOR AND FRAME PER DOOR SCHEDULE
CLIP
FILL SHIM SPACE WITH SPRAY FOAM
FILL DOOR FRAME WITH SPRAY FOAM
TERMINATION BAR
PERIMETER OF OPENING
VAPOR RETARDER, SEE DETAIL 3/A500
INTERIOREXTERIOR
DOOR AND FRAME PER
DOOR SCHEDULE
DOOR FRAME BEYOND
EXISTING STRUCTURE BEYOND
THERMALLY BROKEN
THRESHOLD SEALED
MODIFY EXISTING
FLASHING AS REQUIRED
TO INSTALL THRESHOLD
CONCRETE LANDING
PER 5/A800
EXISTING STEM
WALL TO REMAIN
CONCRETE SLAB
PER 5/A800
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:46 PM
JB
EXTER IOR DETA IL S
A
M L M
3" = 1'-0"A500
1 EXTERIOR SECTION DETAIL - MECHANICAL HOOD PENETRATION
1" = 1'-0"A500
2 STRUCTURAL ELEVATION - DOOR OPENING CONSTRUCTION
3" = 1'-0"A500
3 EXTERIOR SECTION DETAIL - DOOR HEAD
3" = 1'-0"A500
4 EXTERIOR SECTION DETAIL - DOOR JAMB
3" = 1'-0"A500
5 EXTERIOR SECTION DETAIL - DOOR SILL
CEILING PLAN NOTES
B.
C.
D.
E.
COORDINATE MECHANICAL ELEMENTS INCLUDING
EXISTING SPRINKLERS, DIFFUSERS, RETURN AIR SLOTS,
ACCESS PANELS, AND EQUIPMENT.
COORDINATE ELECTRICAL ELEMENTS INCLUDING SMOKE
DETECTOR, LIGHTING, SENSORS, SIGNAGE, ACCESS
PANELS, AND EQUIPMENT WITH ELECTRICAL DOCUMENTS.
NOT ALL CEILING MOUNTED ITEMS ARE SHOWN NOR
IDENTIFIED. CONTRACTOR TO FIELD VERIFY.
SEE A800 FOR SEALING PENETRATIONS THROUGH LEAD-
LINED GYPSUM BOARD.
ANY PENETRATIONS THROUGH THE CEILING SHOULD
HAVE TWO BENDS WITH 1.5 TIMES LINE OF SIGHT
OVERLAP. THESE CAN THEN HAVE SHIELDING BOXES
THAT WOULD MATE WITH DIRECT LEAD CONTACT AT THE
CEILING LEVEL FOR EASE OF MAINTENANCE.
CEILING LEGEND
PNT-#
(SEE FINISH SCHEDULE FOR #)
PROVIDE, PATCH, REPAIR, PREPARE AND
PAINT GYPSUM BOARD CEILING
LOCATION OF PREVIOUSLY REMOVED
SPRINKLER HEADS
MECHANICAL EQUIPMENT
XRAY
VAULT
CHEMICAL
STORAGE
LIQUID
PENETRANT
BEARING
CLEANING
CKT
ROOM
DARK
ROOM
OIL
ANALYSIS
ROOM
WASH
RACK
MECHANICAL
TRAINING
ROOM
EXISTING HVAC DIFFUSERS.
REMOVE AND REPLACE IN KIND
AS REQUIRED TO ACCOMMODATE
LEAD LINING INSTALLATION.
WRAP EXISTING DUCT ABOVE
WITH LEAD LINING PER DETAIL:
C-G2
XRAY
ROOM
A800
FIRE
PUMP
C-G1 C-G3
A600
CONTRACTOR TO FIELD
VERIFY EXISTING DUCT
SIZES AND LAYOUT
BREAK
ROOM
EQUIPMENT
PLATFORM
KEYNOTES
PROVIDE 8 LB, 1/8" LEAD LINED GYPSUM BOARD WITH ALL
PENETRATIONS AND OVERLAP SHIELDED TO THE SAME
LEVEL, SEE A800.
PROVIDE GYPSUM BOARD AND SUSPENSION SYSTEM.
REMOVE AND REINSTALL EXISTING MECHANICAL AND
ELECTRICAL CEILING MOUNTED ITEMS AS REQUIRED TO
ACCOMMODATE FIRE SPRINKLER INSTALLATION.
JO
ISTS PER
ASSEMBLY TYPE
(E) ZEE GIRT
A600
INTERIOR EXTERIOR
FIRE SEALANT AT BACK SIDE OF
FLUTED METAL SIDING.
CONTRACTOR TO CUT GYPSUM
BOARD TO FIT FLUTES
FIRE SEALANT
C-G3
6" METAL STUD WALL
WITH 5/8" GYPSUM BOARD
8"
TAPE / SEAL CUT EDGE
OF INSULATION WITH
ALUMINUM TAPE.
FILL CAVITY WITH BATT
INSULATION
TAPE / SEAL CUT EDGE
OF INSULATION WITH
ALUMINUM TAPE.
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:48 PM
JB
REFL ECTED CE IL ING PL AN
A
LSM
1/8" = 1'-0"A600
1 INTERIOR PLAN - CEILING - 1ST FLOOR
1/8" = 1'-0"A600
2 INTERIOR PLAN - CEILING - 2ND FLOOR
KEYPLAN
1/4" = 1'-0"A600
3 FRAMING PLAN - CEILING
1 1/2" = 1'-0"A600
4 FRAMING SECTION - CEILING
INTERIOR DETAIL NOTES
B.
C.
D.
E.
F.
G.
SEE A0 SHEETS FOR ASSEMBLY TAG LEGEND.
SEE A5 SHEETS FOR EXTERIOR ASSEMBLIES AND
DETAILS.
PROVIDE FINISHES TO FULL HEIGHT OF WALL UNLESS
NOTED OTHERWISE.
LEAD WRAP TO MATCH THICKNESS OF LEAD LINING IN
LEAD-LINED GYPSUM BOARD.
SEAL PENETRATIONS IN LEAD LINED CONSTRUCTION PER
ANSI 43.3 2008 AND OTHER APPLICABLE CODES AND
STANDARDS.
PROVIDE 20 GAUGE METAL STUDS UNLESS NOTED
OTHERWISE.
PROVIDE ADDITIONAL LEAD WRAP AT PENETRATIONS
THROUGH LEAD LINING TO INCLUDE BUT NOT LIMITED TO;
LIGHTING, CONDUIT, SMOKE DETECTORS, SPRINKLER
HEADS, DUCT, VENTILATION DIFFUSERS, HYDRONIC
PIPING AND ELECTRICAL BOXES SHALL BE LINED WITH
LEAD WRAP. WHERE PENETRATIONS HAVE A BEND
PROVIDE LEAD WITH 1.5 TIMES LINE OF SIGHT OVERLAP.
AT CEILING PROVIDE LEAD LINED SHIELDING BOXES THAT
WOULD OVERLAP WITH LEAD LINED GYPSUM BOARD.
W11-6A
LEAD LINED GYPSUM
AT STUD WALL
GYPSUM BOARD - 1/32" LEAD LINED
NORTH WALL, 1/8" WEST WALL
EXISTING WALL ASSEMBLY
W11-6F
WALL INTERIOR 6" STUD
1 HOUR FIRE RATED
IBC TABLE 721.1(2): 13-1.1
GA FILE NUMBER: WP 1072
UL NUMBER: U465
5/8" GYPSUM BOARD
3 5/8" 16 GAUGE METAL
STUDS AT 16" OC
5/8" GYPSUM BOARDEXISTING 1/16" LEAD LINED
GYPSUM BOARD
PROVIDE METAL FRAME -
1/8" LEAD LINED UNLESS
NOTED OTHERWISE
EXTEND LEAD-LINED
GYPSUM WALL BOARD
INTO FRAME TO ALLOW
FOR OVERLAP
EXTERIOR
X-RAY ROOM
INTERIOR
X-RAY ROOM
PROVIDE GYPSUM BOARD
LEAD LINED
3"
PROVIDE STEEL
ASTRAGAL AT PAIR
DOOR - 1/8" LEAD
LINED UNLESS
NOTED OTHERWISE
EXISTING CMU WALL TO REMAIN
PROVIDE WOOD
DOOR - 1/8" LEAD
LINED UNLESS NOTED
OTHERWISE
1/
2"
(DOOR HEAD SIMILAR)
1/
2"
1/ 2"
GYPSUM BOARD LINED
WITH 1/8" LEAD UNLESS
NOTED OTHERWISE
EXISTING DUCT
5/ 8"
MECHANICAL DUCT
PENETRATION
EXISTING PLYWOOD
SHEATHING ON STRUCTURE
LEAD WRAP ALL
SIDES OF DUCT
1/
4"
3/ 4"
4' -0
12"
1 1/2"
PROVIDE GYPSUM BOARD -
1/8" LEAD LINED UNLESS
NOTED OTHERWISE
EXISTING LEAD-LINED
GYPSUM BOARD TO REMAIN
PROVIDE CONTINUOUS 1/8" LEAD
WRAP FROM CEILING ONTO WALL
PROVIDE GYPSUM BOARD 1/8" LEAD LINED
4"
" A
T N
O R
TH
, E
A S
T A
N D
S O
U
TH
W
AL
L.
S
TA
R T
LE
A
D L
IN
E
D G
Y P
S U
M A
T
" A .F
.F
A N
D E
XT
EN
D T
O U
N D
ER
SI
D E
O F
C E
IL
IN
G
A T
W E
S T
W
AL
L
GYPSUM BEAD
EXTERIOR
X-RAY VAULT
INTERIOR
X-RAY VAULT
PROVIDE DOOR
SWEEP - 1/8" LEAD
LINED UNLESS NOTED
OTHERWISE
PROVIDE ALUMINUM
THRESHOLD - 1/8" LEAD
UNLESS NOTED
OTHERWISE
1/ 2"
PROVIDE WOOD DOOR -
1/8" LEAD LINED UNLESS
NOTED OTHERWISE
*SIM AT DOOR 23A
WITH 3/32" LEAD
LINING.
C-G3
CEILING INTERIOR - SUSPENDED GYPSUM BOARD -
1 HOUR FIRE RATED
5/8" GYPSUM BOARD FINISH
PER ROOM SCHEDULE
6" 18 GAUGE METAL JOISTS AT 16" OC
FINISH PER ROOM SCHEDULE
5/8" GYPSUM BOARD
3 1/2 BATT INSULATION
GA FILE NUMBER: FC 4503
UL NUMBER: P512
SEE ROOM SCHEDULE FOR
ASSEMBLY LOCATION AND FINISH
C-G1 CEILING INTERIOR - GYPSUM BOARD
FINISH PER ROOM SCHEDULE
5/8" GYPSUM BOARD
SEE ROOM SCHEDULE FOR ASSEMBLY LOCATION AND FINISH
SUSPENDED GYPSUM GRID SYSTEM
C-G2 CEILING INTERIOR - GYPSUM BOARD
FINISH PER ROOM SCHEDULE
5/8" GYPSUM BOARD - 1/8" LEAD LINED
SEE ROOM SCHEDULE FOR ASSEMBLY LOCATION AND FINISH
EXISTING STRUCTURE TO REMAIN
6" S
LA
B
#5 AT 12" OCEW, CENTERED IN SLAB
EXISTING ASPHALT TO REMAIN
2'-0" COMPACTED STRUCTURAL FILL
IN-SITU SOILS TO REMAIN
MATCH
TOP OF
STEM WALL
SEE A200 FOR NEW WALL
EXISTING WALL TO REMAIN
EXISTING CONCRETE TO REMAIN
SLOPE EXCAVATION AS
NECESSARY TO PREVENT
UNDERMINING OF EXISTING
ASPHALT
NOTE: SEE 31 00 00 FOR
EARTHMOVING REQUIREMENTS
PROVIDE METAL FRAME -
3/32" LEAD LINED UNLESS
NOTED OTHERWISE
EXTEND LEAD-LINED
GYPSUM WALL BOARD
INTO FRAME TO ALLOW
FOR OVERLAP
EXTERIOR
X-RAY ROOM
INTERIOR
X-RAY ROOM
PROVIDE GYPSUM BOARD
LEAD LINED
EXISTING CMU WALL TO REMAIN
PROVIDE WOOD
DOOR - 3/32" LEAD
LINED UNLESS NOTED
OTHERWISE
1/
2"
(DOOR HEAD SIMILAR)
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:50 PM
JB
IN TER IOR ASSEMBL Y TYPES AND DETA IL S
A
LSM
3" = 1'-0"A800
3 INTERIOR DOOR DETAIL - LEAD-LINED DOOR AND FRAME JAMB
3" = 1'-0"A800
4 INTERIOR PENETRATION DETAIL - THRU DUCT WRAP CEILING
3" = 1'-0"A800
1 WALL TO CEILING JOINT
3" = 1'-0"A800
2 INTERIOR DETAIL - LEAD-LINED DOOR THRESHOLD
1" = 1'-0"A800
5 INTERIOR DETAIL - SLAB REPLACEMENT 3" = 1'-0"A800
6 INTERIOR DOOR DETAIL - LEAD-LINED DOOR AND FRAME JAMB AT ROOM 23 18
ROOM SCHEDULE NOTES
B.
PROVIDE FINISHES TO FULL HEIGHT OF WALL UNLESS
NOTED OTHERWISE.
SEE CEILING PLAN WHERE CEILING FINISH VARIES.
1.
2.
ROOM IS LEAD LINED.
PAINT ENTIRE WALL. EXISTING RUBBER BASE AND FIN
TUBE CABINET TO REMAIN, DO NOT PAINT. PAINT ALL
EXPOSED UNPAINTED AND PREVIOUS PAINTED CONDUIT.
ROOM SCHEDULE REMARKS
SEE A001 FOR STANDARD ARCHITECTURAL ABBREVIATIONS
SEE MATERIAL SCHEDULE FOR MATERIAL TYPES
AFF ABOVE FINISHED FLOOR
MFSD MANUFACTURER'S STANDARD
NIC NOT IN CONTRACT
CONC CONCRETE SEALED
ROOM SCHEDULE ABBREVIATIONS
DOOR SCHEDULE REMARKS
DOOR SCHEDULE AND TYPE NOTES
A.
B.
C.
D.
E.
COORDINATE ROUGH OPENING AND SHIM SPACE WITH
MANUFACTURER.
DOOR AND FRAME TYPES REPRESENTED AS VIEWED
FROM EXTERIOR SIDE UNLESS NOTED OTHERWISE.
COORDINATE POWER AND SECURITY WITH ELECTRICAL.
SEE A5 SHEETS FOR EXTERIOR ASSEMBLIES AND
DETAILS.
SEE A8 SHEETS FOR INTERIOR ASSEMBLIES AND DETAILS.
1.
2.
DOOR AND FRAME ARE LEAD LINED.
CONTRACTOR TO FIELD VERIFY DOOR OPENING.
DOOR SCHEDULE ABBREVIATIONS
SEE A001 FOR STANDARD ARCHITECTURAL ABBREVIATIONS
SEE MATERIAL SCHEDULE FOR MATERIAL TYPES
INHM INSULATED HOLLOW METAL
LLWD LEAD LINED WOOD DOOR
LLHM LEAD LINED HOLLOW METAL
MFSD MANUFACTURER STANDARD FINISH
WD WOOD DOOR
DOOR TYPES
F2
FLUSH PAIR
PER SCHEDULE
P E
R S
C H
E D
U
LE
EQ EQ
F1
FLUSH SINGLE
SCHEDULE
PER
P E
R S
C H
E D
U
LE
FRAME TYPES
2" PER SCHEDULE 2"
P E
R S
C H
E D
U
LE
2"
HARDWARE GROUP
HDW-1
DOOR 25A
6 HINGE BB5006 4-1/2 x 4-1/2 N 630 BOOMER INDUSTRIES
1 STOREROOM LOCKSET 45H-7D15H PATD 630 BEST ACCESS SYSTEMS
MANUAL FLUSH BOLT INACTIVE
LEAF TOP & BOTTOM
1 DOOR CLOSER QDC115P 689 STANLEY COMMERCIAL
2 OVERHEAD STOP 1020 A SERIES US32D ABH MANUFACTURING
2 GASKETING 127 SA HEAD & JAMBS NA
2 DOOR SWEEP 200 NA NA
1 THRESHOLD 8426 x 1/4-20 MS/EA AL NA
2 ASTRAGAL - LEAD LINED
*HARDWARE LISTED IS BASIS OF DESIGN. CONTRACTOR TO PROVIDE CYLINDERS, REMOVABLE AND INTERCHANGEABLE CORE SYSTEM: BEST COREMAX PATENTED 7-PIN. ALL OTHER HARDWARE IS "OR
EQUAL".
DOOR HARDWARE SHALL NOT COMPROMISE LEAD SHIELDING.
PROVIDE LEAD FLASHING AS REQUIRED BY MANUFACTURER TO MAINTAIN CONTINUOUS SHIELDING OF
DOOR ASSEMBLY.
HDW-2
DOOR 119A
6 HINGE BB5006 4-1/2 x 4-1/2 N 630 BOOMER INDUSTRIES
1 STOREROOM LOCKSET 45H-7D15H PATD 630 BEST ACCESS SYSTEMS
MANUAL FLUSH BOLT INACTIVE
LEAF TOP & BOTTOM
1 DOOR CLOSER QDC115P 689 STANLEY COMMERCIAL
2 OVERHEAD STOP 1020 A SERIES US32D ABH MANUFACTURING
2 GASKETING 127 SA HEAD & JAMBS NA
2 DRIP CAP 16 A - 4" ODW NA
2 DOOR SWEEP 200 NA NA
1 THRESHOLD 8426 x 1/4-20 MS/EA AL NA
2 ASTRAGAL
HDW-3
DOOR 23A
3 HINGE BB5006 4-1/2 x 4-1/2 N 630 BOOMER INDUSTRIES
1 STOREROOM LOCKSET 45H-7D15H PATD 630 BEST ACCESS SYSTEMS
1 DOOR CLOSER QDC115P 689 STANLEY COMMERCIAL
1 GASKETING 127 SA HEAD & JAMBS NA
1 DOOR SWEEP 200 NA NA
1 THRESHOLD 8426 x 1/4-20 MS/EA AL NA
MATERIAL SCHEDULE NOTES
A.
B.
SEE CEILING PLANS AND ROOM SCHEDULE FOR
LOCATION OF FINISHES.
THE MATERIAL SCHEDULE IS ORGANIZED BY SPEC
NUMBER. MATERIALS WITH SPEC NUMBERS INCLUDING
'NA' ARE INTENDED AS A BASIS OF DESIGN WITH NO
CORRELATING SPEC SECTION.
1.
MISCELLANEOUS
NOT USED
MATERIAL SCHEDULE REMARKS
SEE A001 FOR STANDARD ARCHITECTURAL ABBREVIATIONS
MATERIAL TYPES DEFINED IN MATERIAL SCHEDULE
MFSD MANUFACTURER'S STANDARD
SPEC SPECIFICATION
TYP TYPICAL
MATERIAL SCHEDULE ABBREVIATIONS
A.
B.
C.
D.
E.
F.
COMPOSITE WOOD AND AGRIFIBER PRODUCTS
(INCLUDING ASSOCIATED SUBSTRATE) MUST CONTAIN
NO ADDED UREA-FORMALDEHYDE.
CLEAR WOOD FINISHES, FLOOR COATINGS, STAINS,
PRIMERS, SEALERS, AND SHELLACS (INCLUDING TILE
SETTING ADHESIVE, AND GROUT) APPLIED TO INTERIOR
ELEMENTS MUST NOT EXCEED THE VOC CONTENT LIMITS
ESTABLISHED IN SCAQMD RULE 1113 AS OF 01 JAN 2004.
ADHESIVES, SEALANTS, AND SEALANT PRIMERS APPLIED
TO INTERIOR ELEMENTS MUST COMPLY WITH SCAQMD
RULE 1168 AS OF 01 JULY 2005. AEROSOL ADHESIVES
APPLIED TO INTERIOR ELEMENTS MUST COMPLY WITH
GREEN SEAL GS-36 AS OF 19 OCTOBER 2000.
HARD SURFACE FLOORING AND WALL BASE MUST BE
FLOORSCORE CERTIFIED.
CARPET MUST MEET GREEN LABEL PLUS
REQUIREMENTS. CARPET CUSHION MUST MEET GREEN
LABEL REQUIREMENTS.
ARCHITECTURAL PAINTS AND COATINGS APPLIED TO
INTERIOR ELEMENTS MUST NOT EXCEED THE VOC
CONTENT LIMITS ESTABLISHED IN GREEN SEAL
STANDARD GS-11 AS OF 20 MAY 1993.
LOW EMITTING
LE-
LE-
LE-
LE-
LE-
LE-
AKAF AL
TS
TA
E O
49 TH
S
JAMES D. BARTLETT
No. A10413
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ARCHITE
CT
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
04-JAN-2019
1/2/2019 2:43:52 PM
JB
ROOM, MATER IA L, AND DOOR SCHEDULES
A
M L M
ROOM SCHEDULE
ROOM FLOOR WALL CEILING ROOM
NUMBER NAME FINISH BASE FINISH
ASSEMBLY
TYPE FINISH HEIGHT REMARKS NUMBER
25 XRAY VAULT EXIST EXIST PNT-50 C-G2 PNT-80 12' - 0" 1, 2 25
109 CHEMICAL STORAGE EXIST EXIST EXIST (E) C-G1 PNT-80 9' - 0" 109
110 LIQUID PENETRANT EXIST EXIST EXIST C-G1 PNT-80 9' - 0" 110
111 BEARING CLEANING EXIST EXIST EXIST (E) C-G1 PNT-80 9' - 0" 111
118 STORAGE EXIST EXIST EXIST -- EXIST OTS 118
119 FIRE PUMP CONC -- PNT-50 C-G3 PNT-80 14' 6" 119
MATERIAL SCHEDULE
SPEC TYPE DESCRIPTION LOCATION
BASIS OF DESIGN REMARKS
TYPEMANUFACTURER MODEL COLOR
LOW
EMITTING MISCELLANEOUS
08 10 00 - OPENINGS - DOORS AND FRAMES
08 14 16 WD-1 FLUSH WOOD DOOR PER DOOR SCHEDULE CECO DOORS LEAD LINED DOOR MATCH EXISTING WD-1
09 90 00 - FINISHES - PAINTING AND COATING
09 91 13 PNT-20 EXTERIOR PAINT - DOOR PER DOOR SCHEDULE SHERWIN WILLIAMS EXTERIOR ACRYLIC LATEX TO BE DETERMINED PNT-20 09 91 13 PNT-30 EXTERIOR PAINT - DOOR FRAME PER DOOR SCHEDULE SHERWIN WILLIAMS EXTERIOR ACRYLIC LATEX MATCH MTF-1 PNT-30 09 91 23 PNT-50 INTERIOR PAINT - WALL PER ROOM SCHEDULE SHERWIN WILLIAMS PROMAR 200 INTERIOR LATEX MATCH EXISTING LE-F PNT-50 09 91 23 PNT-70 INTERIOR PAINT - DOOR FRAME PER DOOR SCHEDULE SHERWIN WILLIAMS PROMAR 200 INTERIOR LATEX MATCH EXISTING LE-F PNT-70 09 91 23 PNT-80 INTERIOR PAINT - CEILING PER ROOM SCHEDULE SHERWIN WILLIAMS PROMAR 200 INTERIOR LATEX MATCH EXISTING LE-F PNT-80 09 91 23 SEAL-1 INTERIOR WOOD SEALER EXPOSED INTERIOR WOOD SHERWIN WILLIAMS STAIN / VARNISH MATCH EXISTING LE-B SEAL-1
DOOR SCHEDULE
DOOR
NUMBER
DIMENSIONS DOOR FRAME DETAIL FIRE RATING
(MINUTES)
HARDWARE
GROUP
POWER /
SECURITY REMARKS
DOOR
NUMBERWIDTH HEIGHT MATERIAL TYPE FINISH MATERIAL TYPE FINISH HEAD JAMB SILL
23A 3'-0" 7'-0" LLWD F1 SEAL-1 LLHM 2 PNT-70 6/A800 SIMILAR 6/A800 2/A800 -- HDW-3 -- 1, 2 23A 25A 6'-0" 7'-0" LLWD F2 SEAL-1 LLHM 2 PNT-70 3/ A800 SIMILAR 3/ A800 2/A800 -- HDW-1 -- 1, 2 25A 119A 6'-0" 6'-8" INHM F2 PNT-20 INHM 2 PNT-30 3/A500 4/A500 5/A500 -- HDW-2 -- 119A
ABBREVIATIONS AND SCHEDULES
Marcus P. Curley
No. ME14660
REGISTERED PROFESSIONAL ENGIN
EE
R
02-JAN-2019
DEMOLITION PLANS
No. ME14660
REGISTERED PROFESSIONAL ENGIN
EE
R
02-JAN-2019
MECHANICAL PLANS
No. ME14660
REGISTERED PROFESSIONAL ENGIN
EE
R
02-JAN-2019
MECHANICAL DETAILS
No. ME14660
REGISTERED PROFESSIONAL ENGIN
EE
R
02-JAN-2019
XRAY VAULT
CHEMICAL
STORAGE
LIQUID
PENETRANT
BEARING
CLEANING
CKT ROOM
DARK ROOM
OIL ANALYSIS
ROOM
WASH RACK
MECHANICAL
DEMOLISH EXISTING HALON PIPING ABOVE
HARD LID CEILING AS REQUIRED TO INSTALL
SPRINKLER PIPING. PROVIDE BRANCH
PIPING OR ARMOVERS TO SERVE NEWLY
INSTALLED SPRINKLER HEADS SERVING
SPACES SHOWN. PROVIDE CHROME
PLATED ESCUTCHEONS SERVING ALL
SPRINKLER HEADS.
REMOVE ALL SPRINKLER HEAD
ESCUTCHEONS IN THIS AREA
AND PROVIDE NEW CHROME
PLATED ESCUTCHEONS ON ALL
SPRINKLER HEADS.
EXISTING CROSS MAIN PIPING
SERVING ROOMS TO WEST,
SEE PFOS/PFOA SHEET NOTES.
APPROXIMATE
LOCATION OF
REMOVED HALON
HEAD, 5 TYP.
TRAINING ROOM
XRAY ROOM
FIRE PUMP
F101
EXISTING 3" SPRINKLER PIPING
ABOVE HARD LID CEILING
FACP LOCATED IN ROOM 106
MECHANICAL
EXISTING FDC
TO REMAIN
EXISTING CROSS MAIN UP TO 2ND FLOOR
EXISTING BFP
DEMOLISH EXISTING 6" ELBOW, 2 TYP.
REMOVE
EXISTING DPV
EXISTING 3"
BRANCH
PIPING TO
REMAIN
EXISTING 4"
BRANCH
PIPING TO
REMAIN
FIRE PROTECTION SYMBOLS
CONNECTION TO EXISTING
MANUAL PULL STATIONP
SPEAKER/STROBE
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
1/9/2019 5:07:54 PM
M
SO
F IRE PROTECT ION F IRST F LOOR PL AN
F1 00
M
SO
FIRE PROTECTION NOTES
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
8.
9.
APPLICABLE CODES:
UFC 3-600-01 (CHANGE 1, 28 NOVEMBER 2016)
EIELSON AFB FIRE PROTECTION DESIGN GUIDE - (16 AUGUST 2017)
NFPA 11 (2016)
NFPA 13 (2016)
NFPA 20 (2016)
NFPA 72 (2016)
SCOPE OF WORK:
BUILDING IS PROTECTED WITH EXISTING DRY PIPE SYSTEM.
EXISTING HALON PROTECTION HAS BEEN PREVIOUSLY REMOVED FROM ROOMS 109, 110, 111.
EXISTING FIRE WATER SUPPLY IS NOT ADEQUATE TO SERVE EXISTING DRY PIPE SYSTEM. PROVIDE A SINGLE FIRE PUMP TO PROVIDE ADEQUATE PRESSURE FOR THE EXISTING SUPPRESSION SYSTEM.
PROVIDE SPRINKLER PROTECTION TO ROOMS 109, 110, 111 IN ACCORDANCE WITH UFC 3-600-01 FOR
AN ORDINARY HAZARD SPACE.
EXTEND EXISTING SPRINKLER SYSTEM TO PROVIDE PROTECTION IN NEWLY CREATED FIRE PUMP 119.
PROTECT IN ACCORDANCE WITH UFC 3-600-01 FOR ORDINARY HAZARD.
REPLACE EXISTING DRY PIPE VALVE.
PROVIDE FIRE WATCH IN ACCORDANCE WITH NFPA 25 IF SPRINKLER SYSTEM IS OFFLINE FOR MORE
THAN FOUR HOURS.
TEST ALL NEW AND MODIFIED COMPONENTS IN ACCORDANCE WITH NFPA 25 TABLE 5.5.1.
MODIFY EXISTING MONACO FIRE ALARM SYSTEM TO PROVIDE INPUT MODULES FOR MONITORING NEW FIRE PUMP INSTALLATION, INPUTS TO INCLUDE: RUNNING, LOSS OF PHASE, PHASE REVERSAL).
CONNECT INITIATING DEVICES SHOWN ON PLANS TO EXISTING SYSTEM. TEST MODIFIED FIRE ALARM
SYSTEM IN ACCORDANCE WITH NFPA 72 14.4.2.
EXISTING MANACO FACP IS LOCATED IN ROOM 106 (CEMS OFFICE)
EIE406 SCOPE OF WORK (FOR REFERENCE ONLY):
THIS PROJECT RECENTLY MODIFIED THE WATER SUPPLY FROM B1310(FIRE PUMP BUILDING) TO BE
FROM THE 12-INCH DOMESTIC BASE-WIDE WATER SUPPLY.
REPLACED 6-INCH WATER SUPPLY, DEMOLISH AND REPLACE 6-INCH PIPING FROM WATER SUPPLY TO
POINT OF CONNECTION AT EXISTING DRY PIPE VALVE.
INSTALL DOUBLE CHECK BACKFLOW PREVENTER.
REPLACE FIRE DEPARTMENT CONNECTION PIPING.
FIRE PUMP REQUIREMENTS:
PROVIDE MAINTENANCE ACCESS TO THE FIRE PUMP AND DRIVER SO THEY MAY BE REMOVED FROM
THE ROOM.
PROVIDE A MINIMUM OF 3FT OF CLEARANCE ON THE FRONT SIDE OF THE FIRE PUMP ASSEMBLY FOR MAINTENANCE AND IN FRONT OF THE PUMP CONTROLLER. PROVIDE MINIMUM 3FT FROM THE ROOM
ENTRY TO THE FIRE PUMP AND CONTROLLER.
PROVIDE A MINIMUM 3FT ACCESS TO AND IN FRONT OF ALL EQUIPMENT AND 6IN BEHIND.
PROVIDE LABELING ON THE SURFACES OF THE PIPING IN THE PUMP ROOM TO SHOW THE WATER FLOW DIRECTION AND PIPE FUNCTION (SUCTION, DISCHARGE, TO FDC, TO BYPASS, TO TEST HEADER, TO SPRINKLER SYSTEM). PROVIDE WHITE PAINTED STENCILED LETTERS AND ARROWS, A MINIMUM OF
2IN IN HEIGHT AND VISIBLE FROM AT LEAST THREE SIDES WHEN VIEWED FROM THE FLOOR.
ARRANGE FIRE PUMP TO AUTOMATICALLY SHUT DOWN AFTER REACHING THE STOP PRESSURE AND THE EXPIRATION OF A MINIMUM OF 10-MINUTE RUN TIMER. STOP PRESURE MUST BE AT LEAST 5PSI
BELOW MAX CHURN PRESSURE AT THE LOWEST AVAILABLE STATIC PRESSURE.
FIRE PUMP ACTIVATION MUST TRANSMIT AN ALARM CONDITION TO THE INSTALLATION RECEIVING
STATION BUT NOT ACTIVATE THE FACILITY NOTIFICATION APPLIANCE CIRCUITS.
PROVIDE A TEST HEADER MANIFOLD ON THE FACILITY EXTERIOR THAT PERMITS FLOW TESTING
DIRECTLY FROM THE HEADER.
PROVIDE A FLOW METER INSTALLED IN ACCORDANCE WITH NFPA 20.
PROVIDE A BYPASS IN ACCORDANCE WITH NFPA 20 AROUND THE FIRE PUMP.
PFOS/PFOA SHEET NOTES
1.
2.
THE BUILDING FIRE SUPPRESSION SYSTEM IS KNOWN TO BE CONTAMINATED WITH PFOS/PFOA FROM PUMP STATION 1310. ALL SUPPRESSION PIPING AND EQUIPMENT REMOVED IS REQUIRED TO BE TREATED
AS CONTAMINTED AND DISPOSED OF IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND
INSTALLATION REGULATIONS.
ACCEPTANCE TESTING OF THE MODIFIED SPRINKLER HEADS SYSTEM SHALL INCLUDE REQUIRED
TESTING AT WORKING PRESSURE.
3/16" = 1'-0"F100
1 FIRE SUPPRESSION PLAN
1/4" = 1'-0"F100
2 FIRE PROTECTION DEMOLITION PLAN
FIRE PROTECTION ABBREVIATIONS
KEY NAME
FIRE PROTECTION
ABBREVIATIONS
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPSH NET PUMP SUCTION HEAD
NTS NOT TO SCALE
OS&Y OUTSIDE SCREW & YOKE
PH PHASE
PRDV PRESSURE REDUCING VALVE
PRV PRESSURE RELIEF VALVE
RPM REVOLUTIONS PER MINUTE
S/M SHEET METAL
S/S START/STOP
SH SHOWER
SIM SIMILAR
TYP TYPICAL
VFD VARIABLE FREQUENCY DRIVE
W/ WITH
W/O WITHOUT
FIRE PROTECTION ABBREVIATIONS
KEY NAME
FIRE PROTECTION
ABBREVIATIONS
# NUMBER
& AND
@ AT
APPROX APPROXIMATE
BFP BACKFLOW PREVENTOR
CW COLD WATER
DIA DIAMETER
DPV DRY PIPE VALVE
ELEC ELECTRICAL
EXIST EXISTING
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FP FIRE PROTECTION
MAX MAXIMUM
MECH MECHANICAL
MIN MINIMUM
LINETYPE LEGEND
DEMOLISHED
EXISTING
NEW
AKAF AL
TS
TA
E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
R
03-JAN-2019
Mitchell S. O'Bryant
No. FP14690
P
F101
F101
FIRE PUMP
MECHANICAL
3 5
6 14
EXISTING BRANCH PIPE
ROUTED THROUGH FIRE
PUMP 119, NOT SHOWN
FOR CLARITY. MODIFY
BRANCH PIPING TO
PROVIDE SPRINKLER
PROTECTION WITHIN
FIRE PUMP 119. MODIFY
PIPING ABOVE ROOM TO
PROVIDE PROTECTION
TO LARGER SPACE AT
ROOF LEVEL AS
REQUIRED.
EXISTING ELECTRICAL GEAR
1ST FLOOR
0"
F101
1ST FLOOR
0' - 0"
FIRE PUMP
TO DRY
PIPE
RISER
F101
6 4
TO DRY PIPE RISER
TO FIRE PUMP
TEST HEADER
13 13
2 PIPE DIAM. MIN.
F102
FIRE PUMP
MECHANICAL
MAXIMIZE STRAIGHT
SUCTION PIPING
LENGTH
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
1/9/2019 5:07:59 PM
M
SO
F IRE PROTECT ION P L ANS AND DETAI LS
F1 01
M
SO
1/2" = 1'-0"F101
1 FIRE PROTECTION ENLARGED PLAN
FIRE PROTECTION KEYNOTES
1 VERTICAL IN-LINE ELECTRIC FIRE PUMP
2 ELECTRIC IN-LINE JOCKEY PUMP
1/2" = 1'-0"F101
3 FIRE PUMP TEST HEADER ELEVATION
1/2" = 1'-0"F101
2 FIRE PUMP ELEVATION
3 CHECK VALVE
4 OS&Y GATE VALVE WITH TAMPER SWITCH, NORMALLY OPEN
5 INDICATING BUTTERFLY VALVE, NORMALLY OPEN
6 INDICATING BUTTERFLY VALVE, NORMALLY CLOSED
7 FIRE PUMP TEST METER
8 FIRE PUMP TEST HEADER (4) 2-1/2" HOSE VALVES WITH CAPS,
COORDINATE INSTALL WITH DUCTWORK, DO NOT INSTALL UNDER
INTAKE HOOD.
10 EXISTING BFP
11 6-INCH DRY PIPE VALVE, CONNECT TO EXISTING AIR
COMPRESSOR AND DRAIN PIPING.
9 FIRE PUMP TEST LOOP TO PUMP SUCTION
12 EXISTING FDC
13 PRESSURE GAUGE
14 4" CONCRETE HOUSEKEEPING PAD, 3/F102
15 8" PIPE REQUIRED FOR 10 PIPE DIAMETERS UPSTREAM OF PUMP
SUCTION FLANGE
AKAF AL
TS
TA
E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
R
03-JAN-2019
Mitchell S. O'Bryant
No. FP14690
16 MECHANICAL EQUIPMENT, FOR REFERENCE
17 FIRE PUMP CONTROLLERS
FIRE PUMP
PRESSURE
MAINTENANCE
PUMP
FLOW METER
EXTERIOR FIRE
PUMP TEST
HEADER . (4) 2-1/2"
HOSE VALVES.
NO NO
NO
NC
EXISTING
FDC
NC
6"
6"
6"
6"
6"
8"
NEW 6-INCH DRY
PIPE VALVE
EXISTING DRY PIPE
TO BUILDING
NC
NO
FIRE PUMP 119 MECHANICAL 117
8"
8" 6"
EXISTING 8" FROM UTILIDUCT
BFP
NO NO
EXISTING BACKFLOW PREVENTER
6"
NO EXISTING
DOMESTIC
WATER PIPING
DRAIN VALVE
ISOLATION VALVE WITH INTEGRAL TAMPER SWITCH
OS&Y ISOLATION VALVE WITH TAMPER SWITCH
CHECK VALVE
FIRE DEPARTMENT CONNECTION
HOSE VALVE WITH CAP AND CHAIN
PRESSURE GAUAGE
SECTION A-APLAN
1.
2.
3.
4.
5.
6.
7.
8.
HOUSEKEEPING PAD PLAN DIMENSIONS ARE DEPENDANT ON
EQUIPMENT. SEE FIRE SUPPRESSION EQUPMENT.
6X6-W1.4XW1.4 WELDED WIRE REINFORCEMENT, CENTERED IN
PAD
#3 DOWELS WITH 4 1/2'' LEGS. DRILL AND EPOXY WITH HILTI-HY
200 EPOXY OR APPROVED EQUAL WITH 2 1/2'' EMBED
DOWELS AT 24'' ON CENTER EACH WAY
CHAMFER EXPOSED EDGES 3/4''
BASE SLAB
3'' EDGE DISTANCE FOR DOWELS
4'' PAD THICKNESS UNLESS NOTED OTHERWISE
NOTES
2' - 0"
(3) (2)
(1)
(5) (5)
(6)
(2) (1)
(3)
(8
A A
D ate
P roj ec t N o.
A r chit ect s
E n gin eer s
S u rve yor s
60 1 C olle ge R oa d F airb ank s A K 9 970 1 90 7.45 2.12 41 de sign alas ka.c om
0 4 J A N
2 01 9
F TQ
W
18 -0 20 3
A E
C C
S ht.
O f
3 54 th C iv il E n gi ne e r S q ua dr on
E ie lson A
FB, Alaska
P roj ec t E ng ine er
C hie f E ng in ee r D raw n By
D es ign ed B y
R efe re nc e
N o.
R ev
D es cri ptio n
B y D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
IL IT Y
B
LD
G
1 3 46
1/9/2019 5:08:13 PM
M
SO
F IRE SUPPRESS ION SCHEMAT IC
F1 02
M
SO
F102
1 FIRE PUMP ROOM ISOMETRIC
NO SCALEF102
2 FIRE SUPPRESSION SCHEMATIC
SHEET NOTES:
1.
2.
THE SCHEMATIC DRAWING IS REPRESENTATIVE / CONCEPTUAL IN NATURE. SEE OTHER FIRE
SUPPRESSION SHEETS FOR ADDITIONAL DETAIL, LOCATIONS, CLEARANCES, ETC.
PROVIDE PUMP CONTROLLER PRESSURE SENSING LINES IN ACCORDANCE WITH UFC 3-600-01.
SCHEMATIC SYMBOL LEGEND:
1/2" = 1'-0"F102
3 HOUSEKEEPING PAD
AKAF AL
TS
TA
E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
R
03-JAN-2019
Mitchell S. O'Bryant
No. FP14690
CMU DOOR HEADER
JUNCTION BOX
X-RAY DUAL
INTERLOCK
SWITCH
DOOR
SURFACE MOUNT LIGHTING FIXTURE
J JUNCTION BOX
ELECTRICAL LEGEND
EMERGENCY LIGHTING UNIT
IS DOOR ACCESS HARDWARE - DUAL INTERLOCK SWITCH
WALL MOUNT EMERGENCY EXIT LIGHTING FIXTURE
SPST MANUAL LIGHTING CONTROL DEVICE
M
T
GFCI DUPLEX RECEPTACLE
+4'-0" A.F.F. U.O.N.
MOTOR (HP, VOLTAGE & PHASE NOTED ON DRAWING)
MANUAL MOTOR SWITCH W/ THERMAL OVERLOADS
(PROVIDE WITH MANUFACTURER'S ENCLOSURE FOR A
U.L. LISTED DEVICE)
EQUIPMENT CONNECTION
EXISTING CT
CABINET
EXISTING 480V
DISCONNECT
EXISTING METER
TO EXISTING 480V MAIN
DISTRIBUTION PANEL
(MDP-2)
TO EXISTING 225 KVA
PAD MOUNT SERVICE
TRANSFORMER
SERVICE ENTRANCE RATED
FIRE PUMP CONTROLLER
WITH DISCONNECT AND SOFT
STARTER (NOT TO EXCEED 400%
INRUSH CURRENT).
M
PROVIDE JUNCTION BOX
TO TAP SECONDARY
CONDUCTORS FOR FIRE
PUMP SERVICE
EQUIPMENT
PROVIDE NEW
METER BASE WITH
NEW SMART
METER PER EAFB
METERING
STANDARDS
PROVIDE
JUNCTION BOX
(CT CABINET)
WITH LOOP OR
SPLIT CORE CT'S
200:5
(4) # 4/0 AWG,
#2 AWG SUPPLY SIDE
BONDING
MIN. 2" RMC
ROUTED ALONG
EXTERIOR OF
FACILITY
7,040
X,XXX = AVAILABLE SYMMETRICAL THREE PHASE FAULT CURRENT
INTERIOREXTERIOR
GROUNDING
BUSBAR
FIRE PUMP
125 HP
480V, 3 PH
(3) # 4/0 AWG,
#1/0 GND,
2" C.
#2 AWG GROUNDING ELECTRODE CONDUCTOR
TYP. #2 AWG GROUNDING
ELECTRODE CONDUCTOR TO
OTHER GROUNDING ELECTRODES
LOCATED WITHIN ROOM
#2 AWG GROUNDING
ELECTRODE
CONDUCTOR TO 3/4" X
10' CU. GROUNDING
ELECTRODE.
PROVIDE #2 AWG
BONDING JUMPER TO
ADJACENT GROUNDING
ELECTRODE SYSTEM
AT THE EXISTING 480V
ELECTRICAL SERVICE.
EXISTING TRANSFORMER
RATING
%Z
X/R
V (PRI)
V (SEC)
225 KVA
3.9
3.4 (TYP.)
7200 V
480Y/277 V
FLA (PRI)
FLA (SEC)
MOCP (PRI-FUSE)
18.04 A
270.63 A
65 A NEC 450.3(A), NOTE 1(b)
FIRE PUMP SERVICE CALCULATIONS
FIRE PUMP SIZE
VOLTAGE
FLA
LRC
JOCKEY PUMP SIZE
125 HP
480 V
156 A
908 A
1/2 HP
VOLTAGE
FLA
LRC
480 V
1.1 A
10 A
EXISTING 480V MAIN DISTRIBUTION PANEL (MDP-2)
PARTS CAGE
AHU-2 (3 HP)
MP-1
20 A
4.8 A
100 A
DEMAND LOAD 126 A
TRANSFORMER CALCULATION
125% FIRE PUMP LOADS
SUBTOTAL
100% BUILDING LOADS
156 + 1.1
196.4 A
26 A
26 A WITHOUT MP-1
MIN. SIZE PER LOADS 222.4 A
MIN. SIZE (480V) 185 KVA 225 NEXT STANDARD SIZE
PRIMARY OVERCURRENT CALCULATION
TOTAL LRC
SUBTOTAL
BUILDING LOADS
908 + 10
918 A
26 A
MIN. SIZE PER LOAD (SEC) 944 A
62.93 A 480V TO 7200V
CONDUCTOR AMPACITY
125% FIRE PUMP LOADS
SUBTOTAL
125% BUILDING LOADS
1.25(156 + 1.1)
196.4 A
1.25(26)
SUBTOTAL 32.5 A
MIN. SINGLE FEEDER 228.9 A EXISTING 4/0 RATED 230A
LESS MP-1
LESS MP-1
MIN. SIZE PER LOAD (PRI)
EXISTING LOADS
MCB RATING 300 A
TYPE GE SPECTRA SERIES APNB
NEC TABLE 430.251(B)
NEC TABLE 430.251(B)
ANNOTATION SYMBOLS
L1-12
L1-12
AHU-1
PANEL & CIRCUIT IDENTIFICATION
PANEL & CIRCUIT IDENTIFICATION
B LIGHTING FIXTURE TAG
'L1' DENOTES PANEL NAME, '24' DENOTES CIRCUIT NUMBER.L1-24
LIGHTING FIXTURE TAG (SEE LIGHTING FIXTURE SCHEDULE)B2
SPECIFIC NOTE KEY
(REFERENCE # UNDER 'SPECIFC NOTES' ON EACH SHEET)
a
SWITCH IDENTIFICATION TAG
a SWITCH IDENTIFIER
EQUIPMENT IDENTIFIER, SEE ELECTRIC MOTOR
SCHEDULE
ABBREVIATIONS
AVAILABLE INTERRUPTING CAPACITYAIC
AMERICAN WIRE GAUGEAWG
CURRENT TRANSFORMERCT
COPPERCU
EXISTING TO REMAIN(E)
GROUNDGND
MAIN CIRCUIT BREAKERMCB
RIGID METAL CONDUITRMC
GROUND FAULT CIRCUIT INTERRUPTERGFCI
ABOVE FIXED FLOORAFF
AKAF AL
TS
TA
E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
R
D ate
P roject N o.
A rchitects
E ngineers
S urveyors
601 C ollege R oad Fairbanks AK 99701 907.452.1241 designalaska.com
04 JA
N
FTQ
W
18-0203
A E
C C
S ht.
O f
354th C ivil E ngineer Squadron
E ielson A
FB
, A laska
P roject E ngineer
C hief E ngineer D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
ILITY
B
LD
G
03-Jan-2019
Jeffrey M. Leonelli
EE 107788
1/3/2019 2:53:04 PM
JM
L
ELECTRICAL LEGEND AND SCHEDULES
E
JM
L
NOT TO SCALEE001
2 X-RAY INTERLOCK SWITCH DETAIL
ELECTRIC MOTOR SCHEDULE
TAG DESCRIPTION HP VOLTAGE PH FLA DISC. TYPE MOCP CONDUCTOR AND RACEWAY PANEL
CIRCUIT
NUMBER
JOCKEY PUMP JOCKEY PUMP 1/2 480 V 3 1.1 A JOCKEY PUMP CONTROLLER 20 A (3) #12 AWG, #12 GND., 3/4" C. MDP-2 14,16,18 UH-2 UNIT HEATER 1/20 120 V 1 4.4 A RATED SWITCH 20 A (2) #12 AWG, #12 GND., 1/2" C. M 21 VF-1 VENT FAN 1/2 120 V 1 9.8 A SWITCH W/ THERMAL OVERLOADS 20 A (2) #12 AWG, #12 GND., 1/2" C. M 30
LIGHTING FIXTURE SCHEDULE
FIXTURE
TAG
LAMP BASIS OF DESIGN LIGHTING FIXTURE BASIS OF DESIGN
LAMP
TYPE
LAMP QTY
/ FIXTURE
NOMINAL
LUMENS
PER LAMP
CCT (K) DESCRIPTION MOUNTING MANUFACTURER MODEL
INPUT
LOAD
(W) A2 LED 1 3,200 4,000 1' x 2' CHAIN HUNG LINEAR LED FIXTURE
WITH CLEAR POLYCARBONATE LENS.
+10'-0" AFF DIALIGHT LPM3N4D2P 33
EM LED EMERGENCY LIGHTING UNIT. +7'-6" AFF LITHONIA ELM2-LED-SD 2
SHEET SPECIFIC NOTES
1 COORDINATE WITH EAFB ELECTRICAL SHOP AND UTILITIES TO PROVIDE PRIMARY
FUSE PROTECTION AT FUSE CUTOUTS TO HOLD IN 65A AT 7200V INDEFINITELY UNDER
FIRE PUMP LOCKED ROTOR CONDITION.
2 PROVIDE CONNECTION FROM FIRE PUMP CONTROLLER TO SHUNT TRIP MP-1 CIRCUIT
BREAKER IN MDP-2. CONTROLLER SHALL SHUNT TRIP ON LOW PRESSURE (AUTOMATIC
START CONDITIONS). SHUNT TRIP OPERATION SHALL NOT OCCUR ON PUMP START TO
AVOID CIRCUIT BREAKER RESET AFTER EVERY REQUIRED MAINTENANCE TEST.
NOT TO SCALEE001
1 ONE-LINE RISER DIAGRAM
*** DENOTES CIRCUIT BREAKER WITH SHUNT TRIP OPERATION.
Notes:
Total Est. Demand Current: 127 A Total Conn. Current: 126 A
Total Est. Demand: 105669 VA Equipment 99766 VA 100.00% 99766 VA Total Conn. Load: 104671 VA Motor 4905 VA 120.34% 5903 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 126 A 126 A 126 A Total Load: 34890 VA 34890 VA 34890 VA
17 -- -- -- 27713 305 -- -- -- 18 15 -- -- -- 27713 305 -- -- -- 16
13 ***MP-1 (100A) 200 A 3 27713 305 3 20 A JOCKEY PUMP 14
11 -- -- -- 5543 1330 -- -- -- 12 9 -- -- -- 5543 1330 -- -- -- 10
7 (E) PARTS CAGE 20 A 3 5543 1330 3 20 A (E) AHU-2 (3 HP) 8
5 -- -- -- 0 0 -- -- -- 6 3 -- -- -- 0 0 -- -- -- 4
1 (E) SPARE 60 A 3 0 0 3 60 A (E) SPARE 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Enclosure: TYPE 1 MCB Rating: 300 A Mounting: SURFACE Wires: 4 Mains Rating: 400 A
Supply From: 225 KVA SERVICE TRANSFORMER Phases: 3 Mains Type: MCB Location: STORAGE 118 Volts: 480Y/277V A.I.C. Rating: 25,000
Panel: MDP-2
GENERAL ELECTRICAL NOTES
1.
A.
B.
C.
D.
E.
2.
3.
PROVIDE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND GENERALLY
NOTED BELOW. ALL ELECTRICAL WORK AND MATERIAL IS NEW, AND PROVIDED BY
THE CONTRACTOR UNLESS OTHERWISE INDICATED.
REMOVE AND REINSTALL ELECTRICAL FIXTURES IN ROOM 25 XRAY VAULT
TO FACILITATE ADDITIONAL LEAD SHEILDING.
PROVIDE ADDITIONAL INTERLOCK SWITCH FOR DOUBLE DOOR TO ROOM
25 XRAY VAULT.
REMOVE AND REINSTALL ELECTRICAL FIXTURES IN ROOMS 109-111 TO
FACILITATE WORK ASSOCIATED FOR NEW FIRE SUPPRESSION SYSTEM.
PROVIDE SERVICE TO FIRE PUMP CONTROLLER AND ASSOCIATED
EQUIPMENT.
PROVIDE BRANCH CIRCUITS TO ELECTRICAL FIXTURES IN NEW FIRE PUMP
ROOM.
ALL SUPPORT PENETRATIONS INTO THE WALL AND CEILING SHALL USE
ASSOCIATED FASTENERS OF THE LEAD-LINED WALL ASSEMBLY AND INSTALLED
PER MANUFACTURER'S INSTRUCTION TO MAINTAIN PROPER PROTECTION OF THE
AREA.
FIXTURES DAMAGED DURING THE SALVAGE AND REINSTALLATION SHALL BE
PROVIDED NEW WITH SIMILIAR TYPE AND STYLE FIXTURE.
IS
M
XRAY VAULT
EXISTING XRAY INTERLOCK
SYSTEM CONTROL PANEL
EXISTING INTERLOCK
TERMINAL BOX
TYP. SALVAGED
LIGHT FIXTURE
XRAY ROOM
DARK ROOM
EXISTING MP-1
EXISTING
MP-1
DISCONNECT
TYP. SALVAGED LIGHT FIXTURE
LIQUID
PENETRANT
CHEMICAL
STORAGE
BEARING
CLEANING
(E)
(E)
WASH RACK
MECHANICAL
EXISTING
480V MAIN
DISTRIBUTION
PANEL
(MDP-2)
EXISITING 480V ELECTRICAL SERVICE EQUIPMENT
STORAGE
EXISTING 1200A,
208V SWITCHGEAR
EXISTING
PANEL M
TELEPHONE
AKAF AL
TS
TA
E O
49 TH
S
D E S I G N
A L
A S
K A
REGISTERED PROFESSIONAL ENGIN
EE
R
D ate
P roject N o.
A rchitects
E ngineers
S urveyors
601 C ollege R oad Fairbanks AK 99701 907.452.1241 designalaska.com
04 JA
N
FTQ
W
18-0203
A E
C C
S ht.
O f
354th C ivil E ngineer Squadron
E ielson A
FB
, A laska
P roject E ngineer
C hief E ngineer D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
E N
G
IN
E M A
IN
TE
N A
N C
E FA
C
ILITY
B
LD
G
03-Jan-2019
Jeffrey M. Leonelli
EE 107788
1/3/2019 2:53:07 PM
JM
L
ELECTRICAL DEMOLITION PLANS
E
JM
L
1/4" = 1'-0"E002
1 1ST FLOOR PLAN - ROOM 25 - DEMO
1/4" = 1'-0"E002
2 1ST FLOOR PLAN - ROOMS 109, 110, 111 - DEMO
SHEET SPECIFIC NOTES
1 REMOVE AND REINSTALL ALL ELECTRICAL CONDUIT,
JUNCTION BOXES, DEVICES AND FIXTURES AFFECTED BY
THE ARCHITECTURAL…