JA-2_Statement_of_Work.pdf

PDF 81 KB Posted

Attached to
Arctic Survival Roof Repair Federal contract opportunity
Solicitation number
FA5004-16-B-C004
Issued by
Department of the Air Force Pacific Air Forces

About this file

JA-2 Statement of Work

View the file

Other files for this federal contract opportunity

Other files attached to Arctic Survival Roof Repair, newest first.
File Type Posted
JA-8_UFC_3-530-01.pdf PDF
JA-6_Site_Map_ _As_Built_Drawings.pdf PDF
FA5004-16-B-C004-0001.pdf PDF
Site_Visit_Record.pdf PDF
JA-3_Specifications.pdf PDF
JA-1_Other_Contract_Requirements.pdf PDF
JA-2_Statement_of_Work.pdf PDF
JA-6_Site_Map_ _As_Built_Drawings.pdf PDF
JA-4_Wage_Determination.pdf PDF
FA5004-16-B-C004.pdf PDF
JA-5_AF_Form_66.pdf PDF
JA-7_AF_Forms.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FOR

PROJECT FTQW 16-1023

REPAIR ROOF AT ARCTIC SURVIVAL (B3347)

1.0 SCOPE: Furnish all plant, labor, supplies, parts, transportation, tools, equipment, and facilities necessary to perform work required to complete project FTQW 16-1023 in strict accordance with this Statement of Work, project specifications, and the contract.

2.0 DESCRIPTION OF WORK: Repair the entire roof of Bldg 3347 by replacement. The roof system shall be installed in accordance with manufacturers' specifications, as stated in

Specifications Section 072353, SD-08.

2.1 Remove the existing 20,347 sq. ft. BUR roof system, including insulation. Remove all flashing.

2.2 Remove 20,347 sq. ft. concrete pavers.

2.3 Remove 19 external light fixtures and 1200 LF of electrical wiring.

2.4 Install 19 exterior LED light fixtures w/dusk sensors in accordance with UFC 3-530-

01.

2.5 Install 20,347 90-mil EPDM system insulated to R38 and tapered, where necessary, in accordance with manufacturer's specifications and in the specifications, section 07530.

2.6 Install 20,347 5/8” gypsheeting thermal barrier in accordance with manufacturer’s specifications

2.7 Install new 12,000 SF flashing, expansion joints, and scuppers. Flashings shall be chosen and installed to withstand wind gusts at speeds of up to 24 knots and in accordance to Specifications, Section 07650 and manufacturing specifications. Roof flashing color must match roof material.

2.8 Install manufactured flashing for 43 vents though roof (VTRs) in accordance to

Specifications, Section 07720.

2.9 Install 20,347 SF FFP 8mil polyethylene vapor barrier in accordance to manufacturer’s specifications and to Specifications, Section 07650 8.8.

3.0 Install 10 new roof drains with 2-4” drain extensions and install flashing for drains in accordance to manufacturer’s specifications and Specifications, Section 07650 14.14.

3.1 Install roof warranty signs on exterior of building near roof access points.

3.1.1 Post a 12" x 12" x 1/8" brown sign with white lettering at any and all access points to the roof. These signs will be posted at or near eye level on the nearest vertical surfaces to the access points to the roof and will read as follows:

a. THIS ROOF IS UNDER WARRANTY UNTIL EXPIRATION DATE:

[expiration date of warranty] DO NOT PENETRATE THIS ROOF

WITHOUT NOTIFYING 354 CES Roofing Engineer, 377-3157

3.0 SUBMITTALS: Documents shall be submitted according to the attached AF Form 66.

4.0 GOVERNMENT FURNISHED MATERIALS: None.

5.0 ATTACHMENTS: None.

1 June 2016

END OF STATMENT

File details come from the government source that posted it. Updated .