Updated Drawings.pdf

PDF 2 MB Posted

Attached to
Relocation of Airfield Fence
Solicitation number
FA500022Q0063
Issued by

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A B C D E F G H I

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

PLOT SCALE:

SYMBOL DATE DESCRIPTION

REVISIONS

JOINT BASE ELMENDORF-RICHARDSON, AK

DESIGNED BY:

DRAWN BY:

CHECKED BY:

PROJ. ENG.

DESIGN

CONCEPTUAL

DRAWINGS

1:1

AF CONTRACT NUMBER:

INV. NUMBER:

DATE APPR

DATE:

DATE:

DATE:

DATE:

DRAWING NO:

U.S. AIR FORCE

RELOCATE AIRFIELD FENCE

BLDGS 11535 & 11525

SITE DRAWINGS - AMENDMENT 1

LEGEND

REMOVE EXISTING FENCE

INSTALL NEW FENCE

RECONFIGURE EXISTING VEHICLE GATE

INSTALL NEW PEDESTRIAN GATE

INSTALL NEW MANUAL SWING GATE

INSTALL NEW CIPHER LOCK ON EXTERIOR DOOR

AIRFIELD FENCE RELOCATION

SCALE: 1" = 30'

B11551

NOTES

1. EXISTING FENCE SHALL NOT BE REMOVED UNTIL NEW FENCE IS

FULLY CONSTRUCTED AND SECURED.

2. EXISTING FENCE POSTS SHALL BE CUT OFF TO GROUND LEVEL

AND SEALED. IF EXISTING POST FOUNDATIONS HAVE HEAVED,

FULLY REMOVE, BACKFILL, AND PATCH ASPHALT AS DIRECTED BY

POC.

3. CONTRACTOR MAY EITHER DRIVE NEW FENCE POSTS OR INSTALL

IN CONCRETE. INDICATE WHICH METHOD TO BE USED AT TIME

OF BIDDING.

4. MAJORITY OF FENCE SHALL BE INSTALLED ON THE TOP OF A

SHORT CONCRETE WALL. SECURE THE FENCE POSTS USING

INDUSTRY STANDARD CONCRETE ANCHOR BOLTS AS REQUIRED.

HEIGHT OF COMBINED WALL/FENCE SHALL BE 8' OR HIGHER

FROM ALL ACCESSIBLE SURFACES.

5. ELECTRONIC VEHICLE GATE SHOWN SHALL BE RECONFIGURED TO

OPEN IN THE OPPOSITE DIRECTION SO IT DOES NOT INTERFERE

WITH THE NEW FENCELINE. CUT OFF OR REMOVE EXISTING

BOLLARDS SO THEY DO NOT IMPEDE TRAFFIC OR SNOW

REMOVAL.

6. TWO NEW MANUAL VEHICLE SWING GATES SHALL BE INSTALLED

WHERE SHOWN. ONE NEW PEDESTRIAN SWING GATE WITH

MECHANICAL CIPHER LOCK SHALL BE INSTALLED WHERE SHOWN.

7. INSTALL 3 ELECTRONIC CIPHER LOCKS ON THE EXTERIOR HANGAR

DOORS WHERE SHOWN. THE GOVERNMENT WILL SUPPLY THE

NEW LOCKS.

N

REMOVE EXISTING FENCE

CUT POSTS TO GRADE

RECONFIGURE EXISTING

VEHICLE GATE TO OPEN IN

OPPOSITE DIRECTION

C

INSTALL FENCE ON TOP OF

CONCRETE WALL

NEW PEDESTRIAN GATE W/

MECHANICAL CIPHER LOCK

NEW 20' WIDE

MANUAL SWING GATE

NEW 28' WIDE

MANUAL SWING GATE

C

45 LF±

322 LF±

56 LF±

B11535

B11525

CONNECT TO EXISTING

AIRFIELD FENCE

C

C

CONNECT TO EXISTING

AIRFIELD FENCE

NEW PEDESTRIAN GATE W/

MECHANICAL CIPHER LOCK

Sheets and Views
SITE

File details come from the government source that posted it. Updated .