Electrical and Ceiling Plan for RLFs 2.pdf

PDF 2 MB Posted

Attached to
492 SOW - Furniture
Solicitation number
FA4877-26-QA144
Issued by

About this file

This document consists of construction drawings for a modular facility project at Davis-Monthan Air Force Base in Phoenix, Arizona. The drawings are electrical plans and reflected ceiling plans prepared by Phoenix Modular, Inc. (PMI), with serial number PMI-6883-216120, at 65% completion status. The project involves 34 modular units arranged in a linear configuration, totaling approximately 19,000 square feet of space including unclassified administrative office space (5,554 SF), controlled secured areas (2,175 SF), storage/office areas (4,414 SF), and various functional spaces such as conference rooms, classrooms, workshop areas, restrooms, and break rooms.

The electrical plans detail multiple distribution panels (Panels A through L), including standard power panels and specialized black/red power panels for critical systems, with connections to automatic transfer switches (ATS) and main distribution panels (MDP) to be provided on-site by others. The facility includes 1,800-ampere and 400-ampere MDP capacity with a 400-ampere emergency branch from the main system. The reflected ceiling plans indicate T-grid suspended ceiling systems installed at the factory with hold-backs at module matelines for on-site completion, along with lighting layouts specifying fixture types, wattages (ranging from 30W to 50W), spacing dimensions, occupancy sensors, and exhaust/supply air provisions. All electrical panel feeders and power filter home runs are noted as requiring on-site installation by others.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

SHIPPED-LOOSE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

7A

7A

7A

13A

9A

7A

7A

13A

9A

9A

9A

13A

9A

9A

13A

3M

3M

3M

3M

7C

7D

7C

7D

9D

5M

3M

5M

5M

7M

7M

7M

7M

7M

9M

9M

11M

9M 11M

11M

9D

9D

9D

5E

3M

5M

3M

5M

9M

7M

9B 5C

9B 5C 7C

13A

9B 5C 7C 9D

3E

13A

7B 7D

7J

7J

7J

7J +64"

7J

3E

L 3 3

1AEX

IT

PC

1A

+64"

PANEL M

9A

7M 9M 11M

T

T T

T

T

11F

DED

9F

DED

7F

DED

5F

DED

13A +64"

+64"

7B +64"

+64"

7B +64"

+64"

7D +64"

+64"

3B 5C

7D

7D

J K

A

1C

2H2H 2H

2H

INT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 2/0.1

WALL HATCHING LEGEND:

EXT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 1/0.1

INT. NON-SECURED STC RATED WALL

SEE WALL ASSEMBLY 3/0.1

INT. NON-SECURED STC RATED WALL

WITH CDX ON ONE SIDE

SEE WALL ASSEMBLY 4/0.1

INT. WALL WITH CDX ON ONE SIDE

FOR FUTURE MONITORS 2.0

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

F A

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

COSTRUCTION1 ELECTRICAL PLAN

1/4"=1'-0"

KEY PLAN

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )

10 11 12 13 14 15 16 17 18

15K

SR

9K

SR

13K

SR

SR

1K

EXIT

11M

11M

11M

11M

13M

13M

13M

13M

11J

11J +64"

11J

9J11J

3E

7J

7J

7J

7J +64"

11J13M

7J

3E

1K

1K1K1K1K1K

SR

Y

SR

9K

SR

9K

SR 15K

SR

9K

SR

15K

SR

15K

SR

17K

SR

17K

SR

19K

SR

15K

SR

15K

SR 15K

SR

17K

SR

17K

SR

19K

SR

19K

SR

19K

SR

15K

SR

17K

SR

19K

SR

19K

SR

9K

SR

9K

SR

9K

SR

3K

SR

11K

SR

11K

SR

11K

SR

11K

SR

11K

SR

11K

SR

7K

SR

7K

SR

13K

SR

13K

SR

+64"

13K

SR

13K

SR

13K

SR

13K

SR

7K

SR

7K

SR

PC1J

PC

1H

SR

+60"

SR

+60"

SR

+ 60"

SR

+60"

SR

+64"

SR

+ 60"

SR

+60"

SR

+ 60"

SR

+60"

SR

+60"

SR

+60"

SR

+60"

SR

+60"

SR

+60"

SR

+60"

SR

+60" SR

+60"

SR

+60"

SR

+60" SR

+60"

SR

+60"

SR

+60"

SR

+60"

+64"

C

B

T

T

SR

SRSRSRSRSR

9J

SR

9J

SR

SR

+60"

5J

SR

SR

+60"

9J

SR

SR

+60"

9J

SR

9J

SR

13M

T T

+64"

SR

+ 60"13K

SR

11K

SR

+64"SR

+64"

O SR SR SR SR SR

R S U

T

SR

X

SR

EXIT

INT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 2/0.1

WALL HATCHING LEGEND:

EXT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 1/0.1

INT. NON-SECURED STC RATED WALL

SEE WALL ASSEMBLY 3/0.1

INT. NON-SECURED STC RATED WALL

WITH CDX ON ONE SIDE

SEE WALL ASSEMBLY 4/0.1

INT. WALL WITH CDX ON ONE SIDE

FOR FUTURE MONITORS 2.1

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

COSTRUCTION1 ELECTRICAL PLAN

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

GFCI

5D GFCI

3E

PC

1A

W

HC

HC

W

H

13E

HC

MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

3"

10C

DED

GFCI

PAN

EL A

PAN

EL B

PAN

EL C

PAN

EL D

PAN

EL E

PAN

EL F

3"

5A

5A

5A

11A

9C

DED

GFCI

IM

7A

7A

7A

13A

3P

3P

3C 3C

3C

5A

5A

5A

11A

7B

11A 7B

GFCI

5E

5B 3C 3D

5B 3C 3C

3P

1A

EX

IT

3D 3C

5B 5D

11A

3E

3E

3E

11A

5E

7B

3J

3J

3J

7J

3J

O

O

3B

SR

3B

SR

5B

SR

3B

SR

3A

SR

3B

SR

3A

SR

3A

SR

3A

SR

3A

SR

3A

SR

3A

SR

7A

7A

5A

11A

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

FD FD

12C

DED

GFCI

SHIPPED-LOOSE

5B

SR

SR

+18"

3B

SR SR

+ 60"

11A

2,4P

T

T

T T

T

W48

11C

DED

4'x4' Mother

Pod

O O

3/4" 4'x8' FIRE TREATED

PLYWOOD (PAINTED WHITE

W/ LABEL EXPOSED)

PANEL P

305,7P

306,8P

309,11P

3010,12P

C D E

F G H I B

Q

GFCI

5E

1H

2H

2H

INT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 2/0.1

WALL HATCHING LEGEND:

EXT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 1/0.1

INT. NON-SECURED STC RATED WALL

SEE WALL ASSEMBLY 3/0.1

INT. NON-SECURED STC RATED WALL

WITH CDX ON ONE SIDE

SEE WALL ASSEMBLY 4/0.1

INT. WALL WITH CDX ON ONE SIDE

FOR FUTURE MONITORS 2.2

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

COSTRUCTION1 ELECTRICAL PLAN

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

GFCI

3F

GFCI

3E

W H

13E

HC

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26

BL

POWER FILTER

(BY OTHERS ON SITE)

SR

+60"

1K

PANEL G

PAN

EL H

7H

9H

5H3H

5H

3H 5H 9H

3H 5H 7H

1H

EXIT

3E

3E

3E

3E

7H

3J

3J

3J

7J

3J 3J3J

1K

SR

SRSR

O

O

SR

SR

9K

SR

3K

SR

3K

SR

3K

SR

7K

SR

7K

SR

5K

SR

3K

SR

5K

SR

3K

SR

5K

SR

5K

SR

7K

SR

7K

SR

5K

SR

5K

SR

3F

SR

3F

SR

3F

SR

3G

SR

3F

SR

3F

SR

3G

SR

3G

SR3G

SR

3G

SR

PC

1H

PANEL J

(BLACK POWER)

SR

+60"

SR

+ 60"

SR

+60"

SR

+ 60"

SR

+60"

SR

+60"

SR

+60"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

SR

+18"

.3

S

Q F

T

GENERATOR

(BY OTHERS ON SITE)

10 11 12 13 14 15 16 17 18

B

A

FD

T

SR

SR

0A

M D

P

400A EM1800A MDP

5J

SR

SR

+60"

5J

SR

SR

+60"

9J

SR

5J

SR

PANEL I

(RED POWER)

PANEL K

(BLACK POWER)

11K

SR

SR

+60"

PANEL L

(RED POWER)

10,12G

14,16G

T T

T

ALL HOME RUN AND

PENETRATIONS FOR POWER

FILTER PROVIDED AND

INSTALLED BY DEALER ON

SITE

GROUND

BAR

+24

GROUND

BAR

+24

GROUND

BAR

+24

(2) FOIL WRAPPED

1/2" PVC STUBBED

THRU-WALL FOR

MINISPLIT LINESET

(SEE DETAIL 5/3.5)

+115

3039,41J

3040,42J

3034,36K

3035,37K

3K

SR

M

NOPQ

SR W

SR V

J45J

J46J

J39K

J41K

GFCI

5E

POWER

FILTER

1H

EXIT

2H

2H

1H 1H

INT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 2/0.1

WALL HATCHING LEGEND:

EXT. SECURED STC RATED WALL

SEE WALL ASSEMBLY 1/0.1

INT. NON-SECURED STC RATED WALL

SEE WALL ASSEMBLY 3/0.1

INT. NON-SECURED STC RATED WALL

WITH CDX ON ONE SIDE

SEE WALL ASSEMBLY 4/0.1

INT. WALL WITH CDX ON ONE SIDE

FOR FUTURE MONITORS

2.3

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

COSTRUCTION

1 ELECTRICAL PLAN

1/4"=1'-0"

KEY PLAN

ELECTRICAL NOTE:

ALL PANEL FEEDERS FROM AUTOMATIC

TRANSFER SWITCH (ATS) AND MDP'S TO BE

PROVIDED AND INSTALLED ON SITE BY

OTHERS

INDICATES T-GRID

SUSPENDED CEILING

INSTALLED @ FACTORY

INDICATES SUSPENDED

CEILING HOLD-BACK @

MATELINES, TO BE

COMPLETED ON-SITE

BY OTHERS

CEILING LEGEND

W

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

1 2 3 4 5 6 7 8 9 10

C

B

L 3 3

1AEX

IT

PC

1A

50W

1A

50W

1A

50W

1A

50W

1M

50W

1H

C 50W

1H

E 50W

2H

G 50W

2H

I

50W

2H

J 50W

2H

J 50W

2H

K

50W

2H

L50W

2H

A

50W 2H

A

50W 1C 50W 1C 50W 1C

50W

1M

50W

1M

50W

1M

50W

1M

50W

1M

50W

1M

50W

1M

50W

1M

50W

1M

50W

1B

50W

1B

50W

1B

50W

1C

50W

1C

50W

1C

50W

1C

50W

1D

50W

1D

1H

50W D

1H

50W F

1H

50W H

2H

50W

A

2H

50W J

2H

50W K

2H

50W K

2H

50W L

2H

50W

A

2H

50W L

2H

50W

1B

50W

1B

50W

1B

50W

1M 30W

1D 30W

50W

1A

6" 10" 10" 10"

18"

8"

8"

8"

10"

10"

10"

10"10"

14"

10"

12"

10"

12"

14"

12"

10"

12"

10"

10"

12"

12"

8"

8"

8"

12"

6"

10"

10"

10"

10"

10"8" 8"

8"

10"

8"

10"

8" 8"6"

SHIPPED-LOOSE

1C50W

OCC OCC OCC

PANEL M

T

T T

T

T

B 14B

B 15B

B12B B13B

B 17C

B15C

B 18C

B16C

B 15D

B13D

B 19E

B17E

6"

8" 8"

8" 8"

8" 8"

6"

6"

10"

10"

10"

OCC

A

OCC

A

J K

A

RT

13A

6,8A

2,4A

6,8B

2,4B

RT

9B

6,8C

2,4C

6,8M

2,4M

6,8E

2,4E

RT

11M

RT

9D

SS

SS

SS

SS

SSSS SPSS SP

SS

SS SP SS SS

SS

SS

SS

SSSPSSSS SP

SS SS SS SS SS SS SS

SC

1AEXIT

1C

EX

IT

1A

EX

IT

1C

2H2H 2H

2H

1 REFLECTED CEILING PLAN

1/4"=1'-0"

2.4

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

COSTRUCTION

INSTALLED @ FACTORY

INDICATES SUSPENDED

CEILING HOLD-BACK @

MATELINES, TO BE

COMPLETED ON-SITE

BY OTHERS

CEILING LEGEND

W

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )

10 11 12 13 14 15 16 17 18

SR

1K

EXIT

1K

1K1K1K1K1K

SR

Y

SR

PC1J

PC

1H

C

B

1C

T

T

SR

SRSRSRSRSR

T T

50W

1K

Y

Y

1K

50W

50W

1K

X

X

1K

50W 50W

1K

X

50W 1K

Y

50W

1K

50W

1K

50W

1K

50W

1K

50W

1K

50W

1K

Y

50W

1K

X X

1K

50W

1K

50W

1K

50W

1K

50W

Y

1K

50W

X

1K

50W

50W

1K

50W

1K

50W

1K

U

1J

50W

T

1J

50W

S

1J

50W

R

1J

50W

U

1J

50W

T

1J

50W

S

1J

50W

R

1J

50W

R

1J

50W

R

1J

50W

T

1J

50W

50W

1J

U

50W

1J

U

50W

1J

T

50W

1J

T

50W

1J

S

50W

1J

S

50W

1J

R

50W

1J

R

50W

1I

50W

1I

50W

1I

50W

1I

R 19I

B36J B35J B34J B33J B31J B29J

R 18I

R 17I

R 16I

R 15I

R 14I

R13I R12I R10I R8I R6I R4I

B31K R10L

B30K R9L

B29K R8L

B28K R 7L

B27J

B25J

R 11L

B37J

B38JO SR SR SR SR SR

10"

OCC

SR

Y

OCC

SR

Y

OCC

SR

OCC

SR

X

OCC

SR

T

OCC

SR

R

OCC

SR

OCC

SR

OCC

SR

S OCC

SR

U

R S U

T

OCC

SR

T

SR

X

14,16K

10,12K

RT

11K

22,24K

18,20K 6022,24J

18,20J

RT

3J

30,32J

26,28J

SP

SS SS

SS

SS

SSSS

SSSS

SS

SS

SS

SS SS SS

SSSSSSSS

SS

SS

SS

SS SS

SR

EXIT

1 REFLECTED CEILING PLAN

1/4"=1'-0"

2.5

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

INSTALLED @ FACTORY

INDICATES SUSPENDED

CEILING HOLD-BACK @

MATELINES, TO BE

COMPLETED ON-SITE

BY OTHERS

CEILING LEGEND

W

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

PC

1A

W

MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

B

A PAN

EL A

PAN

EL B

PAN

EL C

PAN

EL D

PAN

EL E

PAN

EL F

1A

EX

IT

OCC OCC

O

O

1 2 3 4 5 6 7 8 9 10

1D 1D

50W

1H

B

50W

1H

D 50W

1H

F 50W

2H

H

50W

1B

50W

1B

50W

1B

50W

1A

50W

1H

C 50W

1H

E 50W

2H

G 50W

2H

I

50W

1H

B 50W

1H

D 50W

1H

F 50W

2H

H

50W

1H

C 50W

1H

E 50W

2H

G 50W

2H

I

50W

1B

50W

1B

50W

1B

50W

1B

50W

1C

50W

1C

50W

1P

50W

1D

50W

1B

B

1H

50W

E

1H

50W G

2H

50W I

2H

50W

B

1H

50W

D

1H

50W F

1H

50W H

2H

50W

C

1H

50W

1H

50W D

1H

50W

E

1H

50W

F

1H

50W

G

2H

50W

H

2H

50W

I

2H

50W

50W

1A

6" 6"

8"

8"

18"

6"

6"

8"

8"

8"

8"

10"

10"

6"

18"

8"

8" 8"

10"

10"

10" 10"

8" 8"

10"

10"

10"

18"

10"

10"

8"

18"

8"

8"

8"

8"

8"8"

10"

180 CFM

1D

80 CFM

1E

SHIPPED-LOOSE

1D

50W

1E

50W

T

T

T T

T

Q

1J

50W

Q

1J

50W

W48

B 14B

B 15B

B 10B

B12B B13B

B 17C

B15C

B 18C

B16C

B 15D

B13D

B 19E

B17E

B 11B

B 13C

B 14C

B 11D

B 15E

4'x4' Mother

Pod

8"

8"

8"

8"

6"

6"

6" 6"

8" 8"

8" 8"

8"

8"

O O

10" 10"

1C 30W

PANEL P

OCC

SR

Q

OCC

B

OCC

B

C D E

F G H I B

Q

RT

9B

14,16A

10,12A 60 6,8D

2,4D

RT

3D

14,16D

10,12D

14,16E

10,12E

SSSS

SS SS

SS

SS

SSSSSSSSSSSSSS

SS

SS

SS

SS SPSP

SS

SS

SS

SS

SSSS SPSS SP

SC

1H

EXIT

1A

EX

IT

1H 1H

EXIT

2H

2H

1 REFLECTED CEILING PLAN

1/4"=1'-0"

2.6

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

INSTALLED @ FACTORY

INDICATES SUSPENDED

CEILING HOLD-BACK @

MATELINES, TO BE

COMPLETED ON-SITE

BY OTHERS

CEILING LEGEND

W

141 SF

HC

102 142 SF

JA

142 SF

JA

197 SF

SG

124 SF

IR

144 SF

BREAK ROOM

V.C.T.

225 SF

MENS

RESTROOM

V.C.T.

159 SF

WOMENS

RESTROOM

V.C.T.

142 SF

SE

125 SF

IG

158 SF

IG

115 126 SF

IG

119 SF

A4 DIR

119 SF

A1 DIR

119 SF

DS

119 SF

SEL

119 SF

COS

155 SF

OFFICE

182 SF

OFFICE

106 SF

OFFICE

103 SF

OFFICE

105 SF

OFFICE

105 SF

OFFICE

5554 SF

UNCLASSIFIED

ADMINISTRATIVE

OFFICE SPACE

108 SF

COMM

MODULE ( )1MODULE ( )2MODULE ( )3MODULE ( )4MODULE ( )5MODULE ( )6MODULE ( )7MODULE ( )8MODULE ( )9MODULE ( )10MODULE ( )11MODULE ( )12MODULE ( )13MODULE ( )14MODULE ( )15MODULE ( )16MODULE ( )17

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25MODULE ( )26MODULE ( )27MODULE ( )28MODULE ( )29MODULE ( )30MODULE ( )31MODULE ( )32MODULE ( )33MODULE ( )34

278 SF

CSS/CCE

282 SF

CSS/CCE

153 SF

WG/CCC

245 SF

WG/CC

192 SF

WG/CD

199 SF

WG/CD

173 SF

WORKSHOP

63 SF

STORAGE

V.C.T.

358 SF

SM CR

969 SF

WG/CC CR

200 SF

CORRIDOR

433 SF

CORRIDOR

125 SF

A5 DIR

119 SF

FM DIR

114 SF

COMM

TILE

234 SF

CONFERENCE

ROOM

54 SF

CLOSET

V.C.T.

70 SF

CLOSET

V.C.T.

108 SF

COMM

103 SF

OFFICE

115 SF

A6 DIR

87 SF

FIRE RISER

ROOM

V.C.T.

370 SF

STC 50.

CONFERENCE

ROOM

690 SF

CLASSROOM

2175 SF

CONTROLLED

SECURED AREA

292 SF

SE

35 SF

MAN TRAP

1237 SF

CORRIDOR

21 SF

JANITOR'S

CLOSET

174 18 SF

CLOSET

4414 SF

STORAGE/OFFICE

AREA

CONTROLLED SECURED AREAOPEN STORAGE/OFFICE

UNCLASSIFIED OFFICE SPACE

79 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

78 SF

ENTRY

V.C.T.

W48

4'x4' Mother

Pod

MODULE ( )18MODULE ( )19MODULE ( )20MODULE ( )21MODULE ( )22MODULE ( )23MODULE ( )24MODULE ( )25

BL

1K

PANEL G

PAN

EL H

1H

EXIT

1K

SR

SRSR

OCC

O

SR

SR

PC

1H

PANEL J

(BLACK POWER)

.3

S

Q F

T

GENERATOR

(BY OTHERS ON SITE)

10 11 12 13 14 15 16 17 18

B

A

1D

50W

1F

50W

1F

50W

1F

50W

1G

50W

1G

50W

1G

M

1H

50W M

1H

50W M

1H

50W M

1H

50W

1G 30W

1H 30W

1G 30W

8"

8"

8"

8" 8"

8"

8"

8"

8"

8"

8"

8"8"

10"

10" 8"8" 8"

10"

10"

8"

8"

10"

8"

180 CFM

1E

80 CFM

1E

T

SR

SR

0A

M D

P

400A EM1800A MDP

PANEL I

(RED POWER)

PANEL K

(BLACK POWER)

1E

50W

PANEL L

(RED POWER)

6"

T T

T

X

1K

50W

50W

1K

W

W

1K

50W

50W

1K

V

50W

1K

V

50W

1K

X50W

1K

X

50W

1K

W

W

1K

50W V

1K

50W

X

1K

50W

1K

50W

1K

50W

50W

1K

50W

1K

50W

1K

T

1J

50WR

1J

50W

N

1J

50W

O

1J

50W

P

1J

50W

Q

1J

50W

P

1J

50W

Q

1J

50W

Q

1J

50W

50W

1J

U

50W

1J

N

50W

1J

O

50W

1J

O

50W

1J

S

50W

1J

P

50W

1J

Q

50W

1J

Q

R 19I

B13J B15J B17J B19J B21J

R 18I

R 17I

R 16I

R 15I

R 14I

R13I R12I R10I R8I R6I R4I

B28K R 7L

B27K R 6L

B23J

R21I

R20I

R 11L

50W

1J

R5L B26K

B25K

B23K

B21K

ALL HOME RUN AND

PENETRATIONS FOR POWER

FILTER PROVIDED AND

INSTALLED BY DEALER ON

SITE

8"

OCC

SR

V

OCC

SR

OCC

SR

V

OCC

SR

X

OCC

SR

OOCC

SR

Q

M

NOPQ

OCC

SR

P OCC

SR

N

OCC

SR

W

SR W

SR V

SCSP

SS

SS

SSSSSSSSSS

SS

SS

SS

SPSP

SS

SS SS

SS

SS

SS SS

SSSS

SSSS

SD

POWER

FILTER

1H

EXIT

1H

EXIT

2H

2H

1H 1H

1 REFLECTED CEILING PLAN

1/4"=1'-0"

2.7

OF

W . M

A D

IS

O

N S

T.

PH

O

EN

IX

, A Z

PH

-4

-6

X

-4

-6

SU

N

B

EL

T M

O D

U

LA

R

IN

C

SHEET:

THESE DRAWINGS

REMAIN THE PROPERTY

OF PHOENIX MODULAR

AND ARE NOT TO BE

USED IN ANYWAY

WITHOUT WRITTEN

PERMISSION.

DEALER:

INTEGRATED

MODULAR SOLUTION

PROJECT:

DAVIS-MONTHAN AIR

FORCE BASE

STATES:

AZ

SERIAL NUMBERS:

PMI-6883-216120

DRAWN BY:

CL/JK

PLOT DATE:

5/14/2026

REV # / DATE / PR #:

#1 PR1-7 4/14/26

#2 PR8-9 5/12/26

MODEL NUMBER:

PH

O

EN

IX M

OD

UL

AR

© 2025

SHAYLON VAUGHN, P.E.

CORPORATE ENGINEER

5301 W. MADISON ST.

PHOENIX, AZ 85043

(602) 447-6460

65%

COMPLETION

NOT

FOR

File details come from the government source that posted it. Updated .