Q and A.pdf

PDF 78 KB Posted

Attached to
Industrial Hydraulic Shear with Removal/Installation Service Federal contract opportunity
Solicitation number
FA487723QA267
Issued by
Department of the Air Force Air Combat Command

View the file

Other files for this federal contract opportunity

Other files attached to Industrial Hydraulic Shear with Removal/Installation Service, newest first.
File Type Posted
Attach 3 - SOW - Removal and Installation of Industrial Shear_updated.pdf PDF
Attach 4 - Existing Shear_Site Location Photos.pdf PDF
Attach 3 - SOW - Removal and Installation of Industrial Shear.pdf PDF
COMBO_Solicitation - Industrial Hydraulic Shear.pdf PDF
Attach 1-CLIN_Pricing_Schedule.docx DOCX document
Attach 2 - SALIENT CHARACTERISTICS Industrial Shear.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation FA487723QA267 Industrial Hydraulic Shear

Vendor Questions & Answers

Q1. To confirm, we are only breaking down old shear and reinstalling the new one, no purchase of the new shear required?

A1. The requirement is for both supply of the product and services for removal of old existing unit/installation of new.

Q2. If the industrial shear is already purchased and waiting outside the building, is it in one solid manufacturing piece or is it disassembled completely into different pieces, and if so how many?

A2. The shear shall be provided for as part of this solicitation.

Q3. Will they accept a better quality European Shear?

A3. The solicitation does not have a brand name requirement. Please submit your best offer/product that meets or exceeds the requirements under Salient Characteristics document as well as Statement of Work.

Q4. Width is stated at NTE 80" - ours is 107.25", is this acceptable?

A4. 80" is the maximum width approved for concrete drilling and anchors - *107.25" is NOT acceptable.

Q5. Height is stated at NTE 97" - ours is 104.75" , is this acceptable A5. *104.75" height IS acceptable as it will not interfere with the above bridge hoist

Q6. Length is stated at NTE 173" - ours is 197" , is this acceptable?

A6. * 173" is the maximum width approved for concrete drilling and anchors. *197" is NOT acceptable.

Q7. Table Height is stated NTE 32" - ours is 38", is this acceptable?

A7. *32" is the maximum table height that will accommodate our current in-house equipment that aid our end users with material lifting and movement.* 38" is NOT acceptable.

Q8. We only offer a 6' squaring arm and your spec asks for a 4' arm - is this acceptable?

A8. *6' squaring arm IS acceptable.

File details come from the government source that posted it. Updated .