SALIENT CHARACTERISTICS

For

INDUSTRIAL SHEAR

1.0. SCOPE OF EQUIPMENT:

All proposed products shall meet or exceed the following specifications outlined in this Salient Characterizes. All items shall be delivered to the 309th Aerospace Maintenance and Regeneration Group (AMARG) – FOB DESTINATION

1.1. PRODUCT PERFORMANCE SPECIFICATION:

Industrial Shear must meet the minimum specifications below:

SPECIFICATIONS

Industrial Shear Dimensions Not to Exceed (NTE):

• Machine Width with Back Gauge: 80" (NTE)

• Height: 97" (NTE)

• Length: 173" (NTE)

• Table Height: 32" (NTE)

Shearing Capacity: • 36-Mild Steel: 3/4" x 144"

• 304-Stainless Steel: 1/2" x 144"

Back-Gauge specs: • Manual Back-Gauge

• 36" Powered Back-Gauge with Multi-Job Programming LED Touch

Screen/Display:

o Manual and Programmable Functions o Inch/Metric conversion and Stroke Counter o Programmable X (backstop) o +/-0.005" Backstop Repeatability

Standard Options: • 48" Squaring Arm with Inlaid Scale (0-48"):

o Flip Up Stops

• Solid Tabletop with :

o Heavy Duty Ball Transfer in Table

• Automatic Lubricant Assembly or One Shot

• Oil Cooler for Hydraulic System

• Power Adjustable Rake

• Powered Blade Gap Adjustment

• Hydraulic Self-Compensating Hold Downs with Anti-Marking Caps

• Knives with Four Cutting Edges

• Must Be Steel Construction

• Hour Meter

• All Hydraulic Oil Supplied for Machine Start-Up

• Work Light

• Bolt/Shim Kit for Leveling

Manufacture/Power Specs:

• Country Of Manufacture must be United States

• Available Power: 460v 3 Phase

• Electrical Standard Compliant NFPA 79

• Safety Interlock for Foot Guard Operation with 120v

• Power Disconnect Switch

Safety/Warranty/ Training:

• All Safeguarding Features Must Be OSHA/ANSI compliant but not limited to:

o 1910.212(a)(1); 1910.212(a)(3)-(iii) o ANSI B 11.4-2003

• Master Keylock Switch

• 5-Year Parts AND 5-Year On-Site Labor

• Must Have On-Site Machine Start-Up and Training of Operators up to

(3) Personal And (2) Maintenance Personal