(APPENDIX 1) Install Razor Wire Perimeter Fence Basewide (ATFP) Project Requirements
− Carefully remove existing top rail (as applicable) and properly store on site to be reused o Contractor shall be responsible for maintaining a 100% secured perimeter at all times during construction that meets requirements outlined in UFC 4-022-03, Security Fences and Gates.
− Remove existing outriggers and 3-strand barbed wire o This material to be removed off site each day
− Provide new 45 degree ”Y”/“V” outriggers permanently affixed to existing fence posts per UFC 4-022-03 o 18 inch in length o Each outrigger having three strands of barbed wire (total of six strands)
− Provide new 6-strand barbed wire per UFC 4-022-o 2-wire strand o 4-point barbs o 12.5 gauge wire o 15-gauge round barbs o 5 inch barb spacing
− Provide new single coil barbed tape concertina to the top of the fence per UFC 4-022-03 o 2 foot in diameter o Single coil extending to 50 feet
(without distortion) o Secured every 18 inches to the top barbed wire strand o Maximum 2 inch gap between the bottom barbed wire and fence fabric
− Reinstall top rail at locations where existing top rails were removed