Attch 3 - Questions and Answers_Solicitation FA469020Q0059_2Sep20.pdf
PDF 308 KB Posted
- Attached to
- Ellsworth AFB Radiant Heat Services
- Solicitation number
- FA469020Q0059
About this file
This document contains a solicitation notice and questions and answers related to a federal contract opportunity. The 28th Contracting Squadron at Ellsworth Air Force Base, South Dakota is soliciting quotes under solicitation number FA469020Q0059 for infrared radiant heat services at Ellsworth AFB. The requirement includes maintenance and repair of infrared tubing systems in several hangars and facilities, with system lengths ranging from 1,050 to 5,600 feet and lift heights up to 85 feet. The contract will have a one year base period and four option years, with a potential six-month extension. Quotes are due by September 16, 2020 and the award will be a 100% small business set-aside under NAICS code 238220. The solicitation and additional attachments provide details on certification requirements, wage determinations, and points of contact for questions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA469020Q00590001 SF 30.pdf | ||
| Attch 2 - WD15-5367 Rev13(30Jun20).txt | TXT text file | |
| Solicitation_Radiant Heat_FA469020Q0059.pdf | ||
| Attch 1 - PWS_Radiant Heat Mx Service_13Aug20.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers
Solicitation FA469020Q0059_Infrared Radiant Heat Services
1. What is the NATE certification you deem the most important? There is around 12 NATE tests
ANSWER to #1: NATE Certification in Gas Heating (GS)
2. What is the tallest height of lift a person would need?
3. What is average length of Radiant tube systems?
ANSWER to #2 and #3:
• Pride Hanger 7540 is the highest IR on Ellsworth, it has 54 Burners with approximately 5,600 feet of IR tubing. It requires an 85 Ft lift at the center of the facility. There is also a soccer field and running track in this facility, so ¾” plywood is required to drive lifts onto the track and field.
• The other Hangars/Facilities are similar in lengths with between 1,050 – 1,400 feet of IR tubing with 20 burners in each facility. These facilities require a 45 Ft lift at their highest points. There could be obstructions at some point in the facilities so an Articulating man-lift is recommended.