FA4659-17-R-0007 Grand Forks AFB BTS

QUESTIONS

Section Title RFP Para# and Page # Question Scope of Work 1.1, Pg. 7 The BTS consists of the base voice system switch, the outside plant (OSP) and inside plant (ISP) systems, network, transmission systems, and all associated equipment described in Appendix 2, which may include other systems (e.g., radio, etc.).

Does the current contractor maintain radio equipment?

The current contractor does not maintain radio equipment. However, they are able to install coax cable in support of radio equipment.

Certification Standards for Telephone Switch Operation

7.2.1, Pg. 27 Does the incumbent workforce associated with maintaining the telephone switch currently have IAT Level II clearance?

Does the current Site Manager have IAT Level II clearance?

The current switch tech does maintain an IAT Level II certification.

The site manager does not have a Level II certification

Workload Estimates Appendix 1, Pg. 34 Can the Government provide historical work order and special project values per year to help us determine the level of effort?

These numbers vary widely depending on the level of funding and mission standup providing a sample from one or even two years does not determine future work load amounts.

Workload Estimates Appendix 1, Pg. 34 Can the Government provide historical data PID utilization information to help us determine the level of effort?

These numbers vary widely depending on the level of funding and mission standup providing a sample from one or even two years does not determine future work load amounts.

Solicitation General Question Will the Government be hosting a site visit to allow contractors the ability to determine a level of effort more effectively?

At this time, the Government does not believe that a site visit is needed.

Alarm Notification 2.1.5, Pg. 13 How is the contractor notified of Alarms after hours? Is it just switch alarms or it all alarms?

The contractor does not normally respond to a switch alarm. The contractors work closely with CORs and would be notified via phone call after hours.

Cable Location, Staking, and Marking

2.1.6, Pg. 13 How many locates are performed on average per month?

Section Title RFP Para# and Page # Question During the summer time, locates can be done as often as 3 times a week or as infrequent as of 1 a month. They are done on an as-needed basis. This does not represent an indication of future needs, however, which will vary.

Global Positioning System (GPS) Services

4.2, Pg. 22 Is there any aerial cable?

No. As per DOD mandates no aerial cable should exist at any base across the Air Force.

Pricing ITO 52.212-1.C.1, Pg. 22 Is there construction or digging required for this effort?

Yes there will be some incidental construction as well as digging

Pricing ITO 52.212-1.C.1, Pg. 22 How many FTE’s are currently on the project and what are their labor classifications?

This is a performance based acquisition. The current contract does not determine what future staffing needs will be.

Pricing ITO 52.212-1.C.1, Pg. 22 How many vehicles are currently being utilized by the incumbent contractor?

The current contract does not determine what future equipment needs will be.

Workload Estimates Appendix 1, Pg. 34 What is the average annual dollar value of Work Orders and Special Projects?

These numbers vary widely depending on the level of funding and if there are special projects funded.

Pricing ITO 52.212-1.C.1, Pg. 22 We are seeking Government information to build in the correct costs related to “tenure” in order to comply with FAR 52.222‐17 and Executive Order 13495. Under this guidance, we are required to provide first right of refusal to qualified incumbent workers. This affects personnel “tenure” and as such the PTO that is allocated to such personnel. The prescribing FAR guidance (FAR 22.12) also addresses the Government providing a list of those incumbent employees. In order to comply with this Executive Order 13495, and to permit contractors to apply PTO costs associated with this “tenure” accurately, would you please provide the number of incumbent employees and the following information for all incumbent personnel.

The Government will release this information to the award winning contractor in advance of the start date.

Past Performance Information

ITO Part II, Pg. 22 Usually, there is a total page count limit to the Past Performance section, which can include Table of Contents, Introductions, company information, etc.

Can the Government please provide a total page count for each proposal volume?

IAW 52.212-1 Addendum, past performance is limited to no more than 3 pages per contract listed.

Performance Surveys ITO Part II, Pg. 22 Will contractors with more than one relevant Past

Performance reference be evaluated the same as a contractor with five relevant PP references?

Contractors’ past performance will be evaluated as stated in the solicitation.

Mission Essential Personnel Plan

ITO Part III. Pg. 23 Will only the Past Performance and Price volumes be evaluated?

Contractor’s proposal will be evaluated as stated in the solicitation.

Mission Essential Personnel Plan

ITO Part III. Pg. 23 Will an offeror that fails to submit a Mission Essential Personnel Plan be eligible for an award?

As stated in the solicitation, mission essential personnel plans will be required to be submitted with the proposal documents. Proposals must conform to the RFP.

Mission Essential Personnel Plan

ITO Part III. Pg. 23 Will an offeror that fails to meet the minimum requirement for DFARS 252.237.7024 Mission Essential Personnel Plan be eligible for an award?

As stated in the solicitation, mission essential personnel plans will be required to be submitted with the proposal documents. Proposals must conform to the RFP.

Mission Essential Personnel Plan

ITO Part III. Pg. 23 If an offerors Mission Essential Personnel Plan fails to meet DFARS 252.237.7024 minimum requirements, will it negatively affect the proposal evaluation?

As stated in the solicitation, mission essential personnel plans will be required to be submitted with the proposal documents. Proposals must conform to the RFP.

Evaluation- Commercial Items

ITO 52.212-2, Pg. 24 What is the Past Performance evaluation guidance when determining the weight of a Subcontract teaming arrangement regarding overall performance confidence assessment rating?

The weight of a teaming arrangement is part of the subjective evaluation of the past performance.

Evaluation- Commercial Items

ITO 52.212-2, Pg. 24 When evaluating subcontractor Past Performance, what is the maximum overall performance confidence assessment rating that can be given?

The performance confidence ratings are located in table one of 25.212-2 addendum

Will subcontractor past performance be given the same weight as a Prime’s Past Performance?

The weight of a subcontractor’s past performance is part of the subjective evaluation of the past performance

Evaluation- Commercial Items

ITO 52.212-2, Pg. 24 If a Prime's Past Performance is given a rating of Neutral Confidence but has a Subcontractor Past Performance of Substantial or Satisfactory confidence, what overall assessment rating will be given to the offeror in comparison to a Prime that has an overall Substantial or Satisfactory Confidence rating?

The Government will not answer questions on theoretical confidence ratings. The offerors will be evaluated IAW the RFP.

Performance Surveys ITO 52.212-1.C.2.(b), Pg.

Provide a list of no more than five (5), of the most relevant contracts performed for Federal agencies and commercial customers within the last three (3) years from the date of the solicitation release date.

Is it the Government intention that a maximum of five Past Performance references can be included in the Past Performance Volume?

IAW 52.212-1 of the solicitation, (Part 2, performance surveys), Provide a list of no more than five (5), of the most relevant contracts performed for Federal agencies and commercial customers within the last three (3) years from the date of the solicitation release date.

Information Regarding Submission of Proposals

ITO, Pg. 23 Hand carried or mailed proposals must be dropped off at 319 CONF, 575 Tuskegee Airmen Blvd., Bldg 418, Grand Forks AFB, ND 58205-6436. The sealed envelope or package used to submit your proposal must show the time and date specified for receipt, the Solicitation Number, and the name and address of the offeror. Offers may also be sent in via email to Mr.

Darrell Haas, darrell.haas.2@us.af.mil or to Ellen Reed, ellen.reed@us.af.mil.

The amendment to the solicitation has changed the address and Points of Contacts.

Is the offeror required to submit a hardcopy of the proposal or is an email only submission acceptable?

An email submission will be accepted, however the Government will not be held liable if the proposal or part of the proposal is not received due to computer issues as stated on page 23. It is the offeror’s responsibility to ensure the proposal has reached the POC’s within 319 CONF before the specified due date and time

Attachment 2 Telephone - Analog to Digital, Line 8

What type of Analog to Digital phone is the Government wanting?

Any digital phone that can also accept an analog connection.

Attachment 2 Coax Cable - PID list, Line

What RG rating does the Government want?

This line is meant for non flexible coax cable at any rating. As this is very rarely used.

mailto:ellen.reed@us.af.mil

Attachment 2 60 Fiber Single Mode Cable – 60 Fiber Multi-Mode Cable, Lines

83, 84

This fiber cable is not a standard size and would have to be special ordered. Could this be deleted from the PID list?

Yes, we have a need to have this specific size.

Attachment 2 Purchase and install units on Fiber cable.

Fiber is Purchased in feet not meters. Could the Government please change the unit for the fiber from meters to feet?

The government does not feel a need to change the pricing list from meters to feet.

Attachment 2 25 Pair, 24 AWG

This item is listed three times. (Rows 37, 44 and 56) could the Government please fix this?

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 50 Pair, 24 AWG

This item is listed three times. (Rows 38, 45 and 58)

An error was made where 24 gauge was put twice

Attachment 2 100 Pair, 24 AWG

This item is listed three times. (Rows 39, 46 and 60)

An error was made where 24 gauge was put twice

Attachment 2 200 Pair, 24 AWG

This item is listed three times. (Rows 40, 47 and 62)

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 300 Pair, 24 AWG This item is listed three times. (Rows 41, 48 and 63) could the Government please fix this?

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 6 Pair Cable, 24 Gauge This item is listed two times. (Rows 42 and 54) could the Government please fix this?

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 12 Pair Cable, 24 Gauge This item is listed two times. (Rows 43 and 55) could the Government please fix this?

An error was made where 24 gauge was put twice

Attachment 2 400 Pair Cable, 24 Gauge

This item is listed two times. (Rows 49 and 64) could the Government please fix this?

An error was made where 24 gauge was put twice

Attachment 2 600 Pair Cable, 24 Gauge

This item is listed two times. (Rows 50 and 65) could

An error was made where 24 gauge was put twice

Attachment 2 900 Pair Cable, 24 Gauge

This item is listed two times. (Rows 51 and 66) could

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 1200 Pair Cable, 24 Gauge This item is listed two times. (Rows 52 and 67) could the Government please fix this?

An error was made where 24 gauge was put twice instead of 22 gauge. This has been corrected.

Attachment 2 VOIP Patch Cord White/Black - 7ft, Line 28

Could the Government please clarify if you want black or white patch cords and what Cat. Rating?

As long as it is either black or white the color does not matter. CAT6 is preferred as the minimum standard

Attachment 2 VOIP Patch Cord White/Black - 14ft, Line 29

Could the Government please clarify if you want black or white patch cords and what Cat. Rating?

As long as it is either black or white the color does not matter. CAT6

Attachment 2 Coax Cable Could the Government please tell us what RG value this coax is?

This line is meant for non-flexible coax cable at any rating. As this is very rarely used.

Attachment 2 60 Fiber Single Mode Cable (line 83) 60 Fiber Multi-Mode Cable (line 84)

This fiber count is a special order, does the Government want it?

Yes, we have a need to have this specific size.

Attachment 2 Fiber Optic Connector -

ST, SM

This item is listed two times. (Rows 141 and 180)

Fixed. Oversight on the document deleted one of the doubles.

LC, SM

This item is listed two times. (Rows 142 and 181)

Fixed. Oversight on the document deleted one of the doubles.

SC, MM

This item is listed two times. (Rows 143 and 182)

Fixed. Oversight on the document deleted one of the doubles.

ST, MM

This item is listed two times. (Rows 144 and 183)

Fixed. Oversight on the document deleted one of the doubles.

Attachment 2 Fiber Optic Connector -

LC, MM

This item is listed two times. (Rows 152 and 184)

Fixed. Oversight on the document deleted one of the doubles.

SC, SM

This item is listed two times. (Rows 140 and 179)

Fixed. Oversight on the document deleted one of the doubles.

Attachment 2 Coyote Splice Kit, Line

Could the Government please provide what size of Coyote Splice case you are looking for?

A case able to support as little as 3 pair and large enough to accept 144 pair

Attachment 2 Fiber Optic Jack, Line 138 What type of fiber jack? (LC, ST or SC)

SC will be the standard the government will accept, however, there may be special equipment in the future that requires other

Attachment 2 Raceway - Non-Metallic Raceway, Line 156

Could the Government provide the size of this Non- Metallic Raceway?

No. The government does not feel that providing the size of this is important as it may vary depending on the job.

Attachment 2 2 inch Roll Pipe PVC/ Inner Duct (Line 201) 4 inch Roll Pipe PVC/ Inner Duct (Line 202)

Should this say just Roll Pipe and not Roll Pipe/Inner duct?

No. The military is not requiring this to be roll pipe.

Attachment 2 Fire Stop Tubes, Line 204 Could the Government please provide what size of firestop tubes they are wanting?

4in or 2in

Attachment 2 Manhole - 60" x 8" base + lid (Line 210) Manhole - 84" x 8" base + lid (Line 211)

Could the Government be more precise on the size of Manholes you want? (WxHxD).

No. The Government does not feel this needs to be specified.

Attachment 2 Generic Conduit, Line 226 Could the Government please provide the size for this generic conduit?

No. The Government does not feel this needs to be specified.

Attachment 2 Snow Marker Pole, Line

Could the Government be more precise on this item?

A pole used to identify comm items that need to be spotted with snow on the ground

Attachment 2 Snow Fencing, Line 232 Could the Government be more precise on this item?

A wooden or plastic fence used to control snow drifts.

Attachment 2 Fiber Roll 12", Line 232 Could the Government be more precise on this item?

No. The government does not feel this needs to be specified.

Attachment 2 Communication and Server

Cabinet, Line 241 Could the Government specify the size of these Communication and Server Cabinet or a part number the Government is looking for?

No. The government does not feel this needs to be specified..

Attachment 2 Communication and Server Cabinet dual wide, Line

Could the Government specify the size of these Communication and Server Cabinet dual wide or a part number the Government is looking for?

No. The government does not feel this needs to be specified.

Attachment 2 Grounding wires, Line 243 Please provide the gauge of this grounding wire?

# 6 AWG the document has been updated.

Attachment 2 Grounding bar, Line 253 Please provide the size for this grounding bar?

No. The government does not feel this needs to be specified.

Attachment 2 Clamp, Metal conduit 1", Line 256

Please provide what type of clamp the Government is looking for?

A metal clamp that could be used to attach 1” conduit

Attachment 2 Clamp, Metal conduit 1/2", Line 257

Please provide what type of clamp the Government is looking for?

A metal clamp that could be used to attach 1/2” conduit

Attachment 2 "J" Hook, Line 259 Please provide the size of J hook the Government is asking for?

No. The military does not feel this needs to be specified.

Attachment 2 1 Gauge, Line 264 Is the Government asking for one gauge copper wire, if so does the Government want it bare or coated?

The item is for a gang outlet box. The document has been updated.

Attachment 2 2 Gauge, Line 265 Is the Government asking for one gauge copper wire, if so does the Government want it bare or coated?

The item is for a gang outlet box. The document has been updated.

Attachment 2 Clean of mud, water, and any other debris, Line 286

Please describe what the Government would like to have cleaned? (Manhole, Handhole or ?)

We would like the manholes drained from water and ensure that all cables/equipment are not covered with mud or other debris.

Attachment 2 Beam Clamp, Line 289 Could the Government be more precise on the size of this item? (size)

No. The military does not feel this needs to be specified.

Attachment 2 Bridal Rings, Line 290 Could the Government be more precise on the size of this item? (size)

No. The military does not feel this needs to be specified.

PWS 2.1.3.6.1, Pg. 11 What is the average length of a cable path?

5,000 feet

PWS 9.1, Pg. 30 Could the Government check this, we believe that is contract has changed.

Attachment 2 Copper Cable, Lines 37 thru 67

Please identify these copper cables as Inside cable, Buried or in a duct system.

Attachment 2 Copper Patch panels The Government calls out for Cat 7 jacks and cable but on cat 7 patch panels, is there a reason for this?

The Government “Control-F” searched the entire PWS and found no reference to CAT7

Attachment 2 Patch panel to Patch panel, Lines 167 thru 176

We are assuming that these are patch cords. Please specify the length that the Government wants.

Attachment 2 GPS, Line 291 The Government is asking to price GPS locations of MH, HH, Pedestal, and Splices. Cost for each element may vary. Can the Government make a separate PID for each?

No. The military does not feel this needs to be separated.

Attachment 2 Cross-connect connection, Line 284

Will the Government please state if these are 2 wire or 4 wire cross connects?

Both

Attachment 2 SC bulkheads, Line 285 Will the Government clarify if these are MM or SM?

Both

Attachment 2 Fiber cable, Lines 71 thru

Please identify if this is indoor fiber, buried fiber or fiber in the duct system.

Lines 71 through 88 include all three of the mentioned fiber.

Would you please provide an updated EIPS document that matches the descriptions in the pricing file?

The Government does not feel that an EIPS is needed.

After reviewing the EIPS document, the IGE provided, and the request, we have decided that an EIPS is not necessary. The example provided defined that a basic telephone was unidentified and needed to be further refined. However, the new IGE/Pricing clearly defines Telephone-Analog and individual model numbers for other phones. In review of the PWS we clearly state that the contractor must comply with all applicable federal documents such as OSHA.

On the excel file Copy of attach_2_Pre-Priced_listing, can you please add a category description and if possible, the existing PID # for the Product.

A description category further defining the individual items would require an extensive amount of alterations and not provide much information. It is in our opinion that the title of the CLIN line is acceptable description.

What do you mean by splice, non-buried?

Splicing non-buried cable refers to inside plant cable or cable that does not have an extensive weather seal.

When will be the last date for questions to be accepted?

The Government will accept questions up to 8 Nov 2017, 4:00 PM CST. This should give enough time to get the answers from the subject matter experts as well as published onto FBO.gov.

CLIN Question Answers

Telephone - Analog to Digital Need more information Answered, see above questions

Generic/Outdated Telephone/Accessories Need more information

This is labor for abating any equipment that is too old to have its own CLIN for abatement. Please note there is only labor associated with this

6 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

12 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

25 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

50 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

100 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

200 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

300 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

400 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

600 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

900 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

1200 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

1500 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

6 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

12 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

25 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

50 Pair Cable, 22 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

50 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

100 Pair Cable, 22 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

100 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

200 Pair Cable, 22 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

200 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

300 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

400 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

600 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

900 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

1200 Pair Cable, 24 Gauge Is this ISP or OSP cable? This includes both inside and outside plant cable.

Coax Cable

What type of coax cable is this? (RG-6, RG-59, RG-11…Plenum, Non- Plenum…ISP/OSP?)

Answered, see above questions

6 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

6 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

12 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

12 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

12 Fiber Composite (6 SM/6 MM) Is this ISP or OSP cable? This includes both inside and outside plant cable.

24 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

24 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

24 Fiber Composite (12 SM/12 MM) Is this ISP or OSP cable? This includes both inside and outside plant cable.

36 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

36 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

48 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

48 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

60 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

60 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

72 Fiber Single Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

72 Fiber Multi-mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

144 Fiber Multi-Mode Cable

Is this ISP or OSP cable?

What core size (50 or 62.5 micron)?

This includes both inside and outside plant cable. The base uses a standard of 62.5 micron fiber.

144 Fiber Single- Mode Cable Is this ISP or OSP cable? This includes both inside and outside plant cable.

Fiber Optic Jack Need more information

(LC/SC/ST?...MM/SM?)

Updated IGE to reflect individual connectors and type of cable.

Fiber Optic Box Need more information (Wall-Mount/Rack- Mount? Capacity)

This is specifically wall mounted. Updated IGE to be more specific.

Coyote Splice Kit Need more information (Size?) Answered, see above questions

FO Patch Panel to Patch Panel SC-SC

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel SC-ST

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel SC-LC

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel SC-MTRJ

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel ST-ST

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel ST-LC

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel ST-MTRJ

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel LC-LC

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel LC-MTRJ

MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

FO Patch Panel to Patch Panel MTRJ-

MTRJ MM/SM

Are these patch cords? If so what length? SM OR MM? If MM, what Core Size?

The size is in meters as described under the unit type.

The core size for all fiber is 62.5 micron.

Generic/Outdated Connector/Jack/Patch Need more information

This is labor for abating any equipment that is too old to have its own CLIN for abatement. Please note there is only labor associated with this

Asphalt Should the install price include materials?

Updated to reflect purchase cost of materials and updated concrete to show cubic yard instead of cubic foot.

Concrete Should the install price include materials?

Updated to reflect purchase cost of materials and updated concrete to show cubic yard instead of cubic foot.

Resodding Should the install price include materials?

Updated to reflect purchase cost of materials and updated concrete to show cubic yard instead of cubic foot.

Communication and Server Cabinet

Need more information, dimensions, Part Number.

Brand is nonspecific as long as it meets TIA standards and DISA STIG standards

Communication and Server Cabinet dual wide

Need more information, dimensions, Part Number.

Brand is nonspecific as long as it meets TIA standards and DISA STIG standards

Clamp, Metal conduit 1" Need more information Answered, see above questions

Clamp, Metal conduit 1/2" Need more information Answered, see above questions

1 Gauge Need more information - Too vague, what is this? Answered, see above questions

2 Gauge Need more information - Too vague, what is this? Answered, see above questions

Bridal Rings Where are these to be used? Answered, see above questions

Fiber Ring, 12" Need more information - Too vague, what is this? Answered, see above questions