JFSD200820 E-001 R1 FA4659-10-R-0019-0004.pdf

PDF 227 KB Posted

Attached to
Replace Interior Lighting Basewide (R/M) Federal contract opportunity
Solicitation number
FA4659-10-R-0019
Issued by
Department of the Air Force Air Mobility Command

About this file

E-001 Revised Drawing Dated 10 August 2010

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LUMINAIRE SCHEDULE

MARK MANUFACTURER CATALOG NO.

LAMPS

FINISH MOUNTING VOLTS REMARKS

ACCEPTABLE

MANUFACTURERS

QTY TYPE

AD LITHONIA

FGB24-4-32-S1-X20-ACLWG-MVO

LT-2/2-LP835-PAF

4 F32/835 T8 WHITE VARIES

2,3

BB LITHONIA

FGB24-6-32-T1-X20-ACLWG-MVO

LT-2/3-LP835-PAF

6 F32/835 T8 WHITE VARIES

2,3

BC LITHONIA

FGB24-6-32-N1-X20-ACLWG-MVO

LT-2/3-LP835-PAF

6 F32/835 T8 WHITE VARIES

2,3

BE

LITHONIA

FGB24-6-32-B1-X20-ACLWG-MVO

LT-2/3-LP835-PAF

6 F32/835 T8 WHITE VARIES

2,3

CC LITHONIA

FGB24-6-54T5HO-N1-X20-ACLWG

-MVOLT-2/3-LP835-PAF

6 F54T5HO WHITE VARIES

2,3

CE LITHONIA

FGB24-6-54T5HO-B1-X20-ACLWG

-MVOLT-2/3-LP835-PAF

6 F54T5HO WHITE VARIES

2,3

DD LITHONIA FHE 654L SD 2/3 6 F54T5HO WHITE VARIES

2,3

LUMINAIRE SCHEDULE REQUIREMENTS

A. ALL FLUORESCENT LUMINAIRES SHALL BE PAINTED AFTER FABRICATION. HOUSINGS FOR RECESSED FLUORESCENT LUMINAIRES SHALL HAVE A MINIMUM DEPTH OF 4".

PROVIDE EXTRUDED ALUMINUM TYPE DOOR FRAMES WHERE LUMINAIRES ARE SPECIFIED WITH ALUMINUM DOOR FRAMES.

B. SUBMIT SHOP DRAWINGS FOR EACH BALLAST AND LAMP TYPE USED ON PROJECT.

C. BALLASTS FOR LINEAR FLUORESCENT T8 LAMPS SHALL BE GE ULTRASTART SERIES (OR EQUAL BY ADVANCE OPTANIUM SERIES). BALLAST CHARACTERISTICS SHALL BE:

PROGRAMMED START, OPERATING VOLTAGE RANGE OF 120-277V Ñ 10%, BALLAST FACTOR GREATER THAN 0.85 (UNLESS OTHERWISE NOTED), T.H.D. OF 10% OR LESS, P.F.

GREATER THAN 0.95, AND A FIVE YEAR WRITTEN REPLACEMENT WARRANTY FROM DATE OF MANUFACTURE.

D. BALLASTS FOR LINEAR FLUORESCENT T5 AND T5H0 LAMPS SHALL BE GE ULTRASTART SERIES (OR EQUAL BY ADVANCE OPTANIUM SERIES). BALLAST CHARACTERISTICS

ARE: PROGRAMMED START, OPERATING VOLTAGE RANGE OF 120-277V Ñ 10%, BALLAST FACTOR GREATER THAN 0.99 (UNLESS OTHERWISE NOTED), T.H.D. OF 10% OR LESS, P.F. GREATER THAN 0.95, AND A FIVE YEAR WRITTEN REPLACEMENT WARRANTY FROM DATE OF MANUFACTURE.

E. ALL COMPACT FLUORESCENT LUMINAIRES SHALL HAVE ELECTRONIC BALLASTS.

F. UNIVERSAL LIGHTING TECHNOLOGIES, OSRAM/SYLVANIA, ADVANCE, G.E., VENTURE, HOLOPHANE, TRIAD AND LUTRON ARE ACCEPTABLE BALLAST MANUFACTURERS FOR

H.I.D. AND COMPACT FLUORESCENT LAMPS.

G. ALL NON-DIMMED FLUORESCENT LAMPS SHALL BE LOW MERCURY TCLP COMPLIANT TYPE.

H. PHILIPS, OSRAM/SYLVANIA, G.E. AND VENTURE ARE ACCEPTABLE LAMP MANUFACTURERS.

I. CONTRACTOR SHALL FIELD VERIFY VOLTAGE OF ALL LUMINAIRES PRIOR TO ORDERING.

J. WHERE LUMINAIRES ARE SHOWN WITH LAMPS SWITCHED SEPARATELY, PROVIDE QUANTITY OF BALLASTS ACCORDINGLY. PROVIDE INSIDE LAMP(S) SWITCHED SEPARATE

FROM OUTSIDE LAMPS UNLESS NOTED OTHERWISE.

K. PROVIDE FACTORY INSTALLED INTEGRAL DISCONNECTING MEANS FOR FLUORESCENT LIGHT LUMINAIRES PER 2008 NEC ARTICLE 410.73.(G). NOTE THAT EXCEPTION NO. 4

AND EXCEPTION NO. 5 WILL NOT BE ACCEPTED.

LUMINAIRE SCHEDULE REMARKS

1. COLUMBIA, DAY-BRITE, LITHONIA, LIGHTOLIER AND METALUX ARE ACCEPTABLE MANUFACTURERS FOR LUMINAIRE TYPE INDICATED.

2. PROVIDE WITH FACTORY POWER HOOK CORD ASSEMBLY, COMPLETE WITH RECEPTACLE, CORD AND PLUG, SAFETY HOOKS AND REQUIRED ACCESSORIES. COORDINATE

EXACT LOCATION OF LUMINAIRES WITH MECHANICAL DUCTWORK. THE RECEPTACLE SHALL BE LOCATED AT BOTTOM OF PENDANT AT LUMINAIRE. A HEAVY DUTY OUTLET

BOX SWIVEL HANGER SHALL BE PROVIDED AT TOP OF PENDANT.

3. PROVIDE MULTI VOLT BALLAST CAPABLE OF ACCEPTING AN INPUT VOLTAGE RANGE FROM 120-277 VOLTS.

OCCUPANCY SENSOR - WALL MOUNTED

HORSEPOWER RATED SWITCH

TIMER SWITCH

MOMENTARY CONTACT SWITCH

LOW VOLTAGE SWITCH - LETTER INDICATES TYPE

FUSED SWITCH

DIMMER SWITCH

FOUR-WAY SWITCH

THREE-WAY SWITCH

DOUBLE POLE SWITCH

SINGLE POLE SWITCH - LETTER INDICATES SWITCH LEG

OCCUPANCY SENSOR - CEILING MOUNTED

DASHED LINE INDICATES

GROUPS OF LUMINAIRES TO BE

CONTROLLED BY OCCUPANCY

SENSOR(S).

OCCUPANCY SENSOR - WALL SWITCH

S

S

S

S

T

S a

S

OS

S D

S LVa

S F

OS

OS

S K

S

P

KEY OPERATED SWITCH

PILOT LIGHT SWITCH

S H

S M

DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL

SWITCHING

FLOOD LIGHT LUMINAIRE

EXTERIOR LUMINAIRE - POLE MOUNTED

EXTERIOR LUMINAIRE - POLE MOUNTED

EXTERIOR LUMINAIRE - POLE MOUNTED

EXTERIOR LUMINAIRE - POLE MOUNTED

FLUORESCENT LUMINAIRE WITH AUXILIARY LIGHT

EMERGENCY LUMINAIRE REMOTE HEADS

PHOTOCELL, DAYLIGHT SENSOR

EMERGENCY BATTERY PACK

FLUORESCENT LUMINAIRE

FLUORESCENT LUMINAIRE - EMERGENCY

FLUORESCENT LUMINAIRE - NIGHT LIGHT

FLUORESCENT STRIP LUMINAIRE

FLUORESCENT WALL MOUNTED LUMINAIRE

FLUORESCENT STRIP LUMINAIRE - EMERGENCY

FLUORESCENT STRIP LUMINAIRE - NIGHT LIGHT

LUMINAIRE

LUMINAIRE - NIGHT LIGHT

LUMINAIRE - EMERGENCY

WALL MOUNTED LUMINAIRE

WALL MOUNTED LUMINAIRE - NIGHT LIGHT

WALL MOUNTED LUMINAIRE - EMERGENCY

FLUORESCENT WALL MOUNTED LUMINAIRE - EMERGENCY

FLUORESCENT WALL MOUNTED LUMINAIRE - NIGHT LIGHT

EXIT SIGN

FLUORESCENT LUMINAIRE - LAMPS SWITCHED SEPARATE

TRACK LUMINAIRE

LIGHTING

ELECTRICAL SYMBOLS LEGEND

(AS APPLICABLE)

D

EM

O

LI

TI

O

N N

O

TE

S U

PD

A

TE

8/

1/

REVISED 1 AUG 2010

BI

D

A D

D

EN

D U

M 8/

/1

AC

File details come from the government source that posted it. Updated .