Exhibit A (Base Year)
| LINE ITEM # | DESCRIPTION | UNIT | EST. QTY. | UNIT PRICE | TOTAL UNIT PRICE | |
| A | 001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | $0.00 | |
| A | 002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, > 20 BF | BF | 600 | $0.00 | |
| A | 003 | REMOVE AND REPLACE WOOD DECKING | BF | 200 | $0.00 | |
| A | 004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 500 | $0.00 | |
| A | 005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, 0-20 BF | BF | 100 | $0.00 | |
| A | 006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, >20 BF | BF | 100 | $0.00 | |
| A | 007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |
| TEAR-OFFS | ||||||
| A | 008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSUL.) | SQ | 500 | $0.00 | |
| A | 009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" THICK | SQ | 500 | $0.00 | |
| A | 00A | ADD FOR DEMOLITION, HAULING, AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS | SQ | 10 | $0.00 | |
| INSTALL NEW BUILT UP ROOF SYSTEMS (BURS) OVER STEEL DECKS | ||||||
| A | 00B | 4-PLY BURS USING ASPHALT | SQ | 10 | $0.00 | |
| A | 00C | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 10 | $0.00 | |
| A | PARTIAL BURS REPAIRS | |||||
| A | 00D | REPAIR BLISTERS | SF | 200 | $0.00 | |
| A | 00E | REPAIR SPLITS | LF | 50 | $0.00 | |
| A | 00F | REPAIR RIDGES | LF | 50 | $0.00 | |
| FURNISH AND INSTALL NEW ROOF INSULATION POLYISOCY ANURATE BOARD INSULATION | ||||||
| A | 00G | 1" THICK, R7.14 | SQ | 100 | $0.00 | |
| A | 00H | 2" THICK, R14.29 | SQ | 100 | $0.00 | |
| A | 00J | 3" THICK, R21.74 | SQ | 1000 | $0.00 | |
| PERLITE BOARD INSULATION, 3/4" THICK, R2.08 | ||||||
| A | 00K | <= 100 SQ | SQ | 100 | $0.00 | |
| A | 00L | GYPSUM (Dens-Deck 1/2") | SQ | 1200 | $0.00 | |
| A | 00M | BATT ROOF INSULATION, R-19 | SF | 1000 | $0.00 | |
| A | 00N | FIBER CANTS | LF | 200 | $0.00 | |
| A | 00P | WOOD CANTS | LF | 50 | $0.00 | |
| A | 00Q | TAPERED FILL 4" INSULATION BOARD | BF | 1000 | $0.00 | |
| A | 00R | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 1000 | $0.00 | |
| SHINGLE ROOFING SYSTEMS | ||||||
| A | 00S | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHINGS AND DRIP EDGES | SQ | 100 | $0.00 | |
| A | 00T | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 100 | $0.00 | |
| A | 00U | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS,INCLUDEING FELT UNDERLAYMENT. | SQ | 10 | $0.00 | |
| A | 00V | FURNISH AND INSTALL CONTINUOUS RIDGE VENTS ON EXISTING ROOFS | LF | 1000 | $0.00 | |
| STANDING SEAM METAL ROOFING | ||||||
| A | 00W | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | |
| A | 00X | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, <=100 SQ | SQ | 100 | $0.00 | |
| A | 00Y | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 100 | $0.00 | |
| A | 00Z | FASCIA PANEL SYSTEM | SF | 100 | $0.00 | |
| A | 010 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |
| A | 011 | INSTALL NEW Fully ADHERED TPO ROOF SYSTEM (R=30) | SQ | 500 | $0.00 | |
| A | 012 | INSTALL NEW FULL ADHERED TPO ROOF SYSTEM (NO INSULATION) | SQ | 500 | $0.00 | |
| A | 013 | REMOVE EXISTING MECHANICALLY-ATTACHED EPDM ROOF SYSTEM, INCLUDING MEMBRANE, INSULATION, FASTENERS, PROTECTION BOARD, FLASHINGS, AND VAPOR BARRIER --DOWN TO ROOF DECKING | SQ | 500 | $0.00 | |
| A | 014 | REMOVE EXISTING MECHANICALLY ATTACHED EPDM ROOF SYSTEM DOWN TO INSULATION AND INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM | SQ | 150 | $0.00 | |
| A | 015 | FURNISH AND INSTALL TAPERED INSULATION | SQ | 100 | $0.00 | |
| A | 016 | FURNISH AND INSTALL WALKWAYS | SF | 100 | $0.00 | |
| A | 017 | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE, TO INCLUDE WASHING WITH WATER TO REVEAL HOLES AND DAMAGE, AND VISUALLY LOCATING EACH HOLE AND PATCHING | SQ | 75 | $0.00 | |
| A | 018 | CLEANING AND INSPECTION OF EPDM FLASHING AND REPAIR OR REPLACE | LF | 150 | $0.00 | |
| A | 019 | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WITH 12 - IN WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| A | 01A | REMOVE EXISTING DETERIORATED TERMINATION BAR AND INSTALL NEW TERMINATION BAR | LF | 200 | $0.00 | |
| A | 01B | REPAIR OR REPLACE VENT THRU ROOF PENETRATION BOOTS OR FLASHINGS | EA | 25 | $0.00 | |
| MISCELLANEOUS METALS FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIM.) | ||||||
| A | 01C | GALVANIZED METAL, 4" - 5" | LF | 50 | $0.00 | |
| A | 01D | GALVANIZED METAL, 6" - 7" | LF | 50 | $0.00 | |
| A | 01E | ALUMINUM, 4" - 5" | LF | 50 | $0.00 | |
| A | 01F | ALUMINUM, 6" - 7" | LF | 50 | $0.00 | |
| A | 01G | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | |
| A | 01H | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | |
| A | 01J | 2-PIECE ALUMINUM, 7" -10" | LF | 50 | $0.00 | |
| A | 01K | 2-PIECE ALUMINUM, 10" -12" | LF | 50 | $0.00 | |
| FURNISH AND INSTALL | ||||||
| A | 01L | GALVANIZED METAL DRIP EDGE | LF | 200 | $0.00 | |
| A | 01M | GALVANIZED METAL COUNTERFLASHING | SF | 100 | $0.00 | |
| A | 01N | GALVANIZED METAL VALLEY FLASHING | SF | 50 | $0.00 | |
| A | 01P | GALVANIZED METAL STEP FLASHING | SF | 50 | $0.00 | |
| A | 01Q | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | |
| A | 01R | GALVANIZED METAL FLASHING - F LAT SHEET | SF | 50 | $0.00 | |
| A | 01S | GALVANIZED METAL CAP FLASHING | SF | 50 | $0.00 | |
| A | 01T | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |
| A | 01U | ALUMINUM COUNTERFLASHING | SF | 250 | $0.00 | |
| A | 01V | ALUMINUM VALLEY FLASHING | SF | 25 | $0.00 | |
| A | 01W | ALUMINUM STEP FLASHING | SF | 25 | $0.00 | |
| A | 01X | ALUMINUM BASE FLASHING | SF | 25 | $0.00 | |
| A | 01Y | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | |
| A | 01Z | ALUMINUM CAP FLASHING | SF | 50 | $0.00 | |
| A | 020 | FURNISH AND INSTALL CONTINUOUS RIDGE VENT | LF | 200 | $0.00 | |
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | ||||||
| A | 021 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | |
| A | 022 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | |
| A | 023 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | |
| ROOF DRAINS | ||||||
| A | 024 | REFLASHING EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 8 | $0.00 | |
| A | 025 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 10 | $0.00 | |
| MISCELLANEOUS ROOFING ITEMS | ||||||
| A | 026 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | |
| A | 027 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | |
| A | 028 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | |
| A | 029 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 5 | $0.00 | |
| A | 02A | REMOVE AND REPLACE PITCH PAN | EA | 5 | $0.00 | |
| A | 02B | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1000 | $0.00 | |
| A | 02C | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1000 | $0.00 | |
| A | 02D | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |
| A | 02E | REPAIR AND REPLACE SPALLS, HOLESL, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 52 | $0.00 | |
| A | 02F | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE | SQ | 50 | $0.00 | |
| A | 02G | FURNISH AND INSTALL ASPHALT-SATURATED FELT UNDERLAYMENT | SQ | 100 | $0.00 | |
| A | 02H | FLUID APPLIED COATING SYSTEM | SF | 2000 | $0.00 | |
| A | 02J | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 | EA | 1 | $0.00 | |
| A | 02K | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 10 | $0.00 | |
| A | 02L | LABOR RATE-MISCELLANEOUS WORK | MH | 3 | $0.00 | |
| GUTTERS AND DOWNSPOUTS | ||||||
| A | 02M | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 200 | $0.00 | |
| A | 02N | FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, GUTTER SCREENS | LF | 1000 | $0.00 | |
| A | 02P | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 500 | $0.00 | |
| A | 02Q | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 500 | $0.00 | |
| A | 02R | ALUMINUM, 4" X 5" | LF | 100 | $0.00 | |
| A | 02S | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | |
| FURNISH AND INSTALL NEW DOWNSPOUTS, INCLUDING BRACKETS, ETC. | ||||||
| A | 02T | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 300 | $0.00 | |
| A | 02U | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | |
| A | 02V | FURNISH AND INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 10 | $0.00 | |
| LIGHTNING PROTECTION / REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM | ||||||
| A | 02W | AIR TERMINALS, INCLUDES COPPER BASE | EA | 20 | $0.00 | |
| A | 02X | CONDUCTORS | LF | 200 | $0.00 | |
| A | 02Y | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 200 | $0.00 | |
| A | 02Z | CONNECTORS | EA | 20 | $0.00 | |
| A | 030 | GROUNDING RODS | EA | 5 | $0.00 | |
| BID ITEMS 0024 THROUGH 0033 ARE FOR WORK IN FAMILY HOUSING (RESIDENTIAL) AREAS ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| A | 031 | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 50 | $0.00 | |
| A | 032 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 100 | $0.00 | |
| A | 033 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 250 | $0.00 | |
| A | 034 | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| A | 035 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 200 | $0.00 | |
| A | 036 | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| A | 037 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| A | 038 | REPAIR EPDM ROOF EDGE TERMINATION CONDITION ACCORDING TO ATTACHED DETAIL | LF | 300 | $0.00 | |
| A | 039 | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| A | 03A | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 50 | $0.00 | |
| BID ITEMS 0034 THROUGH 0064 ARE FOR WORK IN THE CANTONMENT (NON-RESIDENTIAL) AREA ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| A | 03B | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 100 | $0.00 | |
| A | 03C | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| A | 03D | REMOVE FULLY-ADHERED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| A | 03G | REMOVE BALLASTED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| A | 03F | REMOVE MECHANICALLY ATTACHED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| A | 03G | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 50 | $0.00 | |
| A | 03H | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 50 | $0.00 | |
| A | 03J | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| A | 03K | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 100 | $0.00 | |
| A | 03L | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 100 | $0.00 | |
| A | 03M | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| A | 03N | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| A | 03P | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 100 | $0.00 | |
| A | 03Q | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=20) | SQ | 100 | $0.00 | |
| A | 03R | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=30) | SQ | 200 | $0.00 | |
| A | 03S | INSTALL NEW FULLY-ADHERED ROOF SYSTEM (NO INSULATION) | SQ | 200 | $0.00 | |
| A | 03T | INSTALL TAPERED INSULATION | BF | 100 | $0.00 | |
| A | 03U | INSTALL WALKWAYS | SF | 200 | $0.00 | |
| A | 03V | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE | SF | 100 | $0.00 | |
| A | 03W | REMOVE EXISTING BALLAST | SQ | 25 | $0.00 | |
| A | 03X | INSTALL NEW BALLAST | SQ | 25 | $0.00 | |
| A | 03Y | REMOVE DETERIORATED CORRUGATED METAL ROOF DECKING AND INSTALL NEW METAL ROOF DECKING | SQ | 100 | $0.00 | |
| A | 03Z | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WIH 12-INCH WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| A | 040 | REMOVAL OF EXISTING TERMINATION BAR AND INSTALLATION OF NEW TERMINATION BAR | LF | 50 | $0.00 | |
| A | 041 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 75 | $0.00 | |
| A | 042 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 100 | $0.00 | |
| A | 043 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| A | 044 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 10 | $0.00 | |
| A | 045 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 150 | $0.00 | |
| A | 046 | INSTALL NEW RIDGE VENT | LF | 180 | $0.00 | |
| A | 047 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| A | 048 | INSTALL LAMINATED, MULTI LAYERED, ARCHITECTURAL SHINGLES | SQ | 100 | $0.00 | |
| TOTAL ESTIMATED COST: Base Year | $0.00 |
&CFA4625-11-R-0002
Attachment 3 &C1 July 2011 - 30 June 2012
Exhibit B Option Year 1
| LINE ITEM # | DESCRIPTION | UNIT | EST. QTY. | UNIT PRICE | TOTAL UNIT PRICE | |
| B | 001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | $0.00 | |
| B | 002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, > 20 BF | BF | 600 | $0.00 | |
| B | 003 | REMOVE AND REPLACE WOOD DECKING | BF | 200 | $0.00 | |
| B | 004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 500 | $0.00 | |
| B | 005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, 0-20 BF | BF | 100 | $0.00 | |
| B | 006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, >20 BF | BF | 100 | $0.00 | |
| B | 007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |
| TEAR-OFFS | ||||||
| B | 008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSUL.) | SQ | 500 | $0.00 | |
| B | 009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" THICK | SQ | 500 | $0.00 | |
| B | 00A | ADD FOR DEMOLITION, HAULING, AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS | SQ | 10 | $0.00 | |
| INSTALL NEW BUILT UP ROOF SYSTEMS (BURS) OVER STEEL DECKS | ||||||
| B | 00B | 4-PLY BURS USING ASPHALT | SQ | 10 | $0.00 | |
| B | 00C | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 10 | $0.00 | |
| B | PARTIAL BURS REPAIRS | |||||
| B | 00D | REPAIR BLISTERS | SF | 200 | $0.00 | |
| B | 00E | REPAIR SPLITS | LF | 50 | $0.00 | |
| B | 00F | REPAIR RIDGES | LF | 50 | $0.00 | |
| FURNISH AND INSTALL NEW ROOF INSULATION POLYISOCY ANURATE BOARD INSULATION | ||||||
| B | 00G | 1" THICK, R7.14 | SQ | 100 | $0.00 | |
| B | 00H | 2" THICK, R14.29 | SQ | 100 | $0.00 | |
| B | 00J | 3" THICK, R21.74 | SQ | 1000 | $0.00 | |
| PERLITE BOARD INSULATION, 3/4" THICK, R2.08 | ||||||
| B | 00K | <= 100 SQ | SQ | 100 | $0.00 | |
| B | 00L | GYPSUM (Dens-Deck 1/2") | SQ | 1200 | $0.00 | |
| B | 00M | BATT ROOF INSULATION, R-19 | SF | 1000 | $0.00 | |
| B | 00N | FIBER CANTS | LF | 200 | $0.00 | |
| B | 00P | WOOD CANTS | LF | 50 | $0.00 | |
| B | 00Q | TAPERED FILL 4" INSULATION BOARD | BF | 1000 | $0.00 | |
| B | 00R | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 1000 | $0.00 | |
| SHINGLE ROOFING SYSTEMS | ||||||
| B | 00S | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHINGS AND DRIP EDGES | SQ | 100 | $0.00 | |
| B | 00T | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 100 | $0.00 | |
| B | 00U | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS,INCLUDEING FELT UNDERLAYMENT. | SQ | 10 | $0.00 | |
| B | 00V | FURNISH AND INSTALL CONTINUOUS RIDGE VENTS ON EXISTING ROOFS | LF | 1000 | $0.00 | |
| STANDING SEAM METAL ROOFING | ||||||
| B | 00W | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | |
| B | 00X | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, <=100 SQ | SQ | 100 | $0.00 | |
| B | 00Y | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 100 | $0.00 | |
| B | 00Z | FASCIA PANEL SYSTEM | SF | 100 | $0.00 | |
| B | 010 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |
| B | 011 | INSTALL NEW Fully ADHERED TPO ROOF SYSTEM (R=30) | SQ | 500 | $0.00 | |
| B | 012 | INSTALL NEW FULL ADHERED TPO ROOF SYSTEM (NO INSULATION) | SQ | 500 | $0.00 | |
| B | 013 | REMOVE EXISTING MECHANICALLY-ATTACHED EPDM ROOF SYSTEM, INCLUDING MEMBRANE, INSULATION, FASTENERS, PROTECTION BOARD, FLASHINGS, AND VAPOR BARRIER --DOWN TO ROOF DECKING | SQ | 500 | $0.00 | |
| B | 014 | REMOVE EXISTING MECHANICALLY ATTACHED EPDM ROOF SYSTEM DOWN TO INSULATION AND INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM | SQ | 150 | $0.00 | |
| B | 015 | FURNISH AND INSTALL TAPERED INSULATION | SQ | 100 | $0.00 | |
| B | 016 | FURNISH AND INSTALL WALKWAYS | SF | 100 | $0.00 | |
| B | 017 | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE, TO INCLUDE WASHING WITH WATER TO REVEAL HOLES AND DAMAGE, AND VISUALLY LOCATING EACH HOLE AND PATCHING | SQ | 75 | $0.00 | |
| B | 018 | CLEANING AND INSPECTION OF EPDM FLASHING AND REPAIR OR REPLACE | LF | 150 | $0.00 | |
| B | 019 | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WITH 12 - IN WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| B | 01A | REMOVE EXISTING DETERIORATED TERMINATION BAR AND INSTALL NEW TERMINATION BAR | LF | 200 | $0.00 | |
| B | 01B | REPAIR OR REPLACE VENT THRU ROOF PENETRATION BOOTS OR FLASHINGS | EA | 25 | $0.00 | |
| MISCELLANEOUS METALS FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIM.) | ||||||
| B | 01C | GALVANIZED METAL, 4" - 5" | LF | 50 | $0.00 | |
| B | 01D | GALVANIZED METAL, 6" - 7" | LF | 50 | $0.00 | |
| B | 01E | ALUMINUM, 4" - 5" | LF | 50 | $0.00 | |
| B | 01F | ALUMINUM, 6" - 7" | LF | 50 | $0.00 | |
| B | 01G | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | |
| B | 01H | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | |
| B | 01J | 2-PIECE ALUMINUM, 7" -10" | LF | 50 | $0.00 | |
| B | 01K | 2-PIECE ALUMINUM, 10" -12" | LF | 50 | $0.00 | |
| FURNISH AND INSTALL | ||||||
| B | 01L | GALVANIZED METAL DRIP EDGE | LF | 200 | $0.00 | |
| B | 01M | GALVANIZED METAL COUNTERFLASHING | SF | 100 | $0.00 | |
| B | 01N | GALVANIZED METAL VALLEY FLASHING | SF | 50 | $0.00 | |
| B | 01P | GALVANIZED METAL STEP FLASHING | SF | 50 | $0.00 | |
| B | 01Q | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | |
| B | 01R | GALVANIZED METAL FLASHING - F LAT SHEET | SF | 50 | $0.00 | |
| B | 01S | GALVANIZED METAL CAP FLASHING | SF | 50 | $0.00 | |
| B | 01T | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |
| B | 01U | ALUMINUM COUNTERFLASHING | SF | 250 | $0.00 | |
| B | 01V | ALUMINUM VALLEY FLASHING | SF | 25 | $0.00 | |
| B | 01W | ALUMINUM STEP FLASHING | SF | 25 | $0.00 | |
| B | 01X | ALUMINUM BASE FLASHING | SF | 25 | $0.00 | |
| B | 01Y | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | |
| B | 01Z | ALUMINUM CAP FLASHING | SF | 50 | $0.00 | |
| B | 020 | FURNISH AND INSTALL CONTINUOUS RIDGE VENT | LF | 200 | $0.00 | |
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | ||||||
| B | 021 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | |
| B | 022 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | |
| B | 023 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | |
| ROOF DRAINS | ||||||
| B | 024 | REFLASHING EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 8 | $0.00 | |
| B | 025 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 10 | $0.00 | |
| MISCELLANEOUS ROOFING ITEMS | ||||||
| B | 026 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | |
| B | 027 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | |
| B | 028 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | |
| B | 029 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 5 | $0.00 | |
| B | 02A | REMOVE AND REPLACE PITCH PAN | EA | 5 | $0.00 | |
| B | 02B | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1000 | $0.00 | |
| B | 02C | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1000 | $0.00 | |
| B | 02D | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |
| B | 02E | REPAIR AND REPLACE SPALLS, HOLESL, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 52 | $0.00 | |
| B | 02F | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE | SQ | 50 | $0.00 | |
| B | 02G | FURNISH AND INSTALL ASPHALT-SATURATED FELT UNDERLAYMENT | SQ | 100 | $0.00 | |
| B | 02H | FLUID APPLIED COATING SYSTEM | SF | 2000 | $0.00 | |
| B | 02J | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 | EA | 1 | $0.00 | |
| B | 02K | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 10 | $0.00 | |
| B | 02L | LABOR RATE-MISCELLANEOUS WORK | MH | 3 | $0.00 | |
| GUTTERS AND DOWNSPOUTS | ||||||
| B | 02M | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 200 | $0.00 | |
| B | 02N | FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, GUTTER SCREENS | LF | 1000 | $0.00 | |
| B | 02P | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 500 | $0.00 | |
| B | 02Q | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 500 | $0.00 | |
| B | 02R | ALUMINUM, 4" X 5" | LF | 100 | $0.00 | |
| B | 02S | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | |
| FURNISH AND INSTALL NEW DOWNSPOUTS, INCLUDING BRACKETS, ETC. | ||||||
| B | 02T | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 300 | $0.00 | |
| B | 02U | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | |
| B | 02V | FURNISH AND INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 10 | $0.00 | |
| LIGHTNING PROTECTION / REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM | ||||||
| B | 02W | AIR TERMINALS, INCLUDES COPPER BASE | EA | 20 | $0.00 | |
| B | 02X | CONDUCTORS | LF | 200 | $0.00 | |
| B | 02Y | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 200 | $0.00 | |
| B | 02Z | CONNECTORS | EA | 20 | $0.00 | |
| B | 030 | GROUNDING RODS | EA | 5 | $0.00 | |
| BID ITEMS 0024 THROUGH 0033 ARE FOR WORK IN FAMILY HOUSING (RESIDENTIAL) AREAS ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| B | 031 | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 50 | $0.00 | |
| B | 032 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 100 | $0.00 | |
| B | 033 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 250 | $0.00 | |
| B | 034 | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| B | 035 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 200 | $0.00 | |
| B | 036 | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| B | 037 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| B | 038 | REPAIR EPDM ROOF EDGE TERMINATION CONDITION ACCORDING TO ATTACHED DETAIL | LF | 300 | $0.00 | |
| B | 039 | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| B | 03A | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 50 | $0.00 | |
| BID ITEMS 0034 THROUGH 0064 ARE FOR WORK IN THE CANTONMENT (NON-RESIDENTIAL) AREA ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| B | 03B | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 100 | $0.00 | |
| B | 03C | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| B | 03D | REMOVE FULLY-ADHERED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| B | 03G | REMOVE BALLASTED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| B | 03F | REMOVE MECHANICALLY ATTACHED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| B | 03G | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 50 | $0.00 | |
| B | 03H | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 50 | $0.00 | |
| B | 03J | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| B | 03K | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 100 | $0.00 | |
| B | 03L | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 100 | $0.00 | |
| B | 03M | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| B | 03N | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| B | 03P | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 100 | $0.00 | |
| B | 03Q | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=20) | SQ | 100 | $0.00 | |
| B | 03R | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=30) | SQ | 200 | $0.00 | |
| B | 03S | INSTALL NEW FULLY-ADHERED ROOF SYSTEM (NO INSULATION) | SQ | 200 | $0.00 | |
| B | 03T | INSTALL TAPERED INSULATION | BF | 100 | $0.00 | |
| B | 03U | INSTALL WALKWAYS | SF | 200 | $0.00 | |
| B | 03V | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE | SF | 100 | $0.00 | |
| B | 03W | REMOVE EXISTING BALLAST | SQ | 25 | $0.00 | |
| B | 03X | INSTALL NEW BALLAST | SQ | 25 | $0.00 | |
| B | 03Y | REMOVE DETERIORATED CORRUGATED METAL ROOF DECKING AND INSTALL NEW METAL ROOF DECKING | SQ | 100 | $0.00 | |
| B | 03Z | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WIH 12-INCH WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| B | 040 | REMOVAL OF EXISTING TERMINATION BAR AND INSTALLATION OF NEW TERMINATION BAR | LF | 50 | $0.00 | |
| B | 041 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 75 | $0.00 | |
| B | 042 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 100 | $0.00 | |
| B | 043 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| B | 044 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 10 | $0.00 | |
| B | 045 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 150 | $0.00 | |
| B | 046 | INSTALL NEW RIDGE VENT | LF | 180 | $0.00 | |
| B | 047 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| B | 048 | INSTALL LAMINATED, MULTI LAYERED, ARCHITECTURAL SHINGLES | SQ | 100 | $0.00 | |
| TOTAL ESTIMATED COST: Option Year 1 | $0.00 |
&CFA4625-11-R-0002
Attachment 3 &C1 July 2012 - 30 June 2013
Exhibit C Option Year 2
| LINE ITEM # | DESCRIPTION | UNIT | EST. QTY. | UNIT PRICE | TOTAL UNIT PRICE | |
| C | 001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | $0.00 | |
| C | 002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, > 20 BF | BF | 600 | $0.00 | |
| C | 003 | REMOVE AND REPLACE WOOD DECKING | BF | 200 | $0.00 | |
| C | 004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 500 | $0.00 | |
| C | 005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, 0-20 BF | BF | 100 | $0.00 | |
| C | 006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, >20 BF | BF | 100 | $0.00 | |
| C | 007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |
| TEAR-OFFS | ||||||
| C | 008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSUL.) | SQ | 500 | $0.00 | |
| C | 009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" THICK | SQ | 500 | $0.00 | |
| C | 00A | ADD FOR DEMOLITION, HAULING, AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS | SQ | 10 | $0.00 | |
| INSTALL NEW BUILT UP ROOF SYSTEMS (BURS) OVER STEEL DECKS | ||||||
| C | 00B | 4-PLY BURS USING ASPHALT | SQ | 10 | $0.00 | |
| C | 00C | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 10 | $0.00 | |
| PARTIAL BURS REPAIRS | ||||||
| C | 00D | REPAIR BLISTERS | SF | 200 | $0.00 | |
| C | 00E | REPAIR SPLITS | LF | 50 | $0.00 | |
| C | 00F | REPAIR RIDGES | LF | 50 | $0.00 | |
| FURNISH AND INSTALL NEW ROOF INSULATION POLYISOCY ANURATE BOARD INSULATION | ||||||
| C | 00G | 1" THICK, R7.14 | SQ | 100 | $0.00 | |
| C | 00H | 2" THICK, R14.29 | SQ | 100 | $0.00 | |
| C | 00J | 3" THICK, R21.74 | SQ | 1000 | $0.00 | |
| PERLITE BOARD INSULATION, 3/4" THICK, R2.08 | ||||||
| C | 00K | <= 100 SQ | SQ | 100 | $0.00 | |
| C | 00L | GYPSUM (Dens-Deck 1/2") | SQ | 1200 | $0.00 | |
| C | 00M | BATT ROOF INSULATION, R-19 | SF | 1000 | $0.00 | |
| C | 00N | FIBER CANTS | LF | 200 | $0.00 | |
| C | 00P | WOOD CANTS | LF | 50 | $0.00 | |
| C | 00Q | TAPERED FILL 4" INSULATION BOARD | BF | 1000 | $0.00 | |
| C | 00R | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 1000 | $0.00 | |
| SHINGLE ROOFING SYSTEMS | ||||||
| C | 00S | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHINGS AND DRIP EDGES | SQ | 100 | $0.00 | |
| C | 00T | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 100 | $0.00 | |
| C | 00U | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS,INCLUDEING FELT UNDERLAYMENT. | SQ | 10 | $0.00 | |
| C | 00V | FURNISH AND INSTALL CONTINUOUS RIDGE VENTS ON EXISTING ROOFS | LF | 1000 | $0.00 | |
| STANDING SEAM METAL ROOFING | ||||||
| C | 00W | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | |
| C | 00X | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, <=100 SQ | SQ | 100 | $0.00 | |
| C | 00Y | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 100 | $0.00 | |
| C | 00Z | FASCIA PANEL SYSTEM | SF | 100 | $0.00 | |
| C | 010 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |
| C | 011 | INSTALL NEW Fully ADHERED TPO ROOF SYSTEM (R=30) | SQ | 500 | $0.00 | |
| C | 012 | INSTALL NEW FULL ADHERED TPO ROOF SYSTEM (NO INSULATION) | SQ | 500 | $0.00 | |
| C | 013 | REMOVE EXISTING MECHANICALLY-ATTACHED EPDM ROOF SYSTEM, INCLUDING MEMBRANE, INSULATION, FASTENERS, PROTECTION BOARD, FLASHINGS, AND VAPOR BARRIER --DOWN TO ROOF DECKING | SQ | 500 | $0.00 | |
| C | 014 | REMOVE EXISTING MECHANICALLY ATTACHED EPDM ROOF SYSTEM DOWN TO INSULATION AND INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM | SQ | 150 | $0.00 | |
| C | 015 | FURNISH AND INSTALL TAPERED INSULATION | SQ | 100 | $0.00 | |
| C | 016 | FURNISH AND INSTALL WALKWAYS | SF | 100 | $0.00 | |
| C | 017 | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE, TO INCLUDE WASHING WITH WATER TO REVEAL HOLES AND DAMAGE, AND VISUALLY LOCATING EACH HOLE AND PATCHING | SQ | 75 | $0.00 | |
| C | 018 | CLEANING AND INSPECTION OF EPDM FLASHING AND REPAIR OR REPLACE | LF | 150 | $0.00 | |
| C | 019 | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WITH 12 - IN WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| C | 01A | REMOVE EXISTING DETERIORATED TERMINATION BAR AND INSTALL NEW TERMINATION BAR | LF | 200 | $0.00 | |
| C | 01B | REPAIR OR REPLACE VENT THRU ROOF PENETRATION BOOTS OR FLASHINGS | EA | 25 | $0.00 | |
| MISCELLANEOUS METALS FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIM.) | ||||||
| C | 01C | GALVANIZED METAL, 4" - 5" | LF | 50 | $0.00 | |
| C | 01D | GALVANIZED METAL, 6" - 7" | LF | 50 | $0.00 | |
| C | 01E | ALUMINUM, 4" - 5" | LF | 50 | $0.00 | |
| C | 01F | ALUMINUM, 6" - 7" | LF | 50 | $0.00 | |
| C | 01G | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | |
| C | 01H | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | |
| C | 01J | 2-PIECE ALUMINUM, 7" -10" | LF | 50 | $0.00 | |
| C | 01K | 2-PIECE ALUMINUM, 10" -12" | LF | 50 | $0.00 | |
| FURNISH AND INSTALL | ||||||
| C | 01L | GALVANIZED METAL DRIP EDGE | LF | 200 | $0.00 | |
| C | 01M | GALVANIZED METAL COUNTERFLASHING | SF | 100 | $0.00 | |
| C | 01N | GALVANIZED METAL VALLEY FLASHING | SF | 50 | $0.00 | |
| C | 01P | GALVANIZED METAL STEP FLASHING | SF | 50 | $0.00 | |
| C | 01Q | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | |
| C | 01R | GALVANIZED METAL FLASHING - F LAT SHEET | SF | 50 | $0.00 | |
| C | 01S | GALVANIZED METAL CAP FLASHING | SF | 50 | $0.00 | |
| C | 01T | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |
| C | 01U | ALUMINUM COUNTERFLASHING | SF | 250 | $0.00 | |
| C | 01V | ALUMINUM VALLEY FLASHING | SF | 25 | $0.00 | |
| C | 01W | ALUMINUM STEP FLASHING | SF | 25 | $0.00 | |
| C | 01X | ALUMINUM BASE FLASHING | SF | 25 | $0.00 | |
| C | 01Y | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | |
| C | 01Z | ALUMINUM CAP FLASHING | SF | 50 | $0.00 | |
| C | 020 | FURNISH AND INSTALL CONTINUOUS RIDGE VENT | LF | 200 | $0.00 | |
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | ||||||
| C | 021 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | |
| C | 022 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | |
| C | 023 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | |
| ROOF DRAINS | ||||||
| C | 024 | REFLASHING EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 8 | $0.00 | |
| C | 025 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 10 | $0.00 | |
| MISCELLANEOUS ROOFING ITEMS | ||||||
| C | 026 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | |
| C | 027 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | |
| C | 028 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | |
| C | 029 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 5 | $0.00 | |
| C | 02A | REMOVE AND REPLACE PITCH PAN | EA | 5 | $0.00 | |
| C | 02B | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1000 | $0.00 | |
| C | 02C | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1000 | $0.00 | |
| C | 02D | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |
| C | 02E | REPAIR AND REPLACE SPALLS, HOLESL, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 52 | $0.00 | |
| C | 02F | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE | SQ | 50 | $0.00 | |
| C | 02G | FURNISH AND INSTALL ASPHALT-SATURATED FELT UNDERLAYMENT | SQ | 100 | $0.00 | |
| C | 02H | FLUID APPLIED COATING SYSTEM | SF | 2000 | $0.00 | |
| C | 02J | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 | EA | 1 | $0.00 | |
| C | 02K | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 10 | $0.00 | |
| C | 02L | LABOR RATE-MISCELLANEOUS WORK | MH | 3 | $0.00 | |
| GUTTERS AND DOWNSPOUTS | ||||||
| C | 02M | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 200 | $0.00 | |
| C | 02N | FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, GUTTER SCREENS | LF | 1000 | $0.00 | |
| C | 02P | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 500 | $0.00 | |
| C | 02Q | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 500 | $0.00 | |
| C | 02R | ALUMINUM, 4" X 5" | LF | 100 | $0.00 | |
| C | 02S | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | |
| FURNISH AND INSTALL NEW DOWNSPOUTS, INCLUDING BRACKETS, ETC. | ||||||
| C | 02T | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 300 | $0.00 | |
| C | 02U | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | |
| C | 02V | FURNISH AND INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 10 | $0.00 | |
| LIGHTNING PROTECTION / REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM | ||||||
| C | 02W | AIR TERMINALS, INCLUDES COPPER BASE | EA | 20 | $0.00 | |
| C | 02X | CONDUCTORS | LF | 200 | $0.00 | |
| C | 02Y | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 200 | $0.00 | |
| C | 02Z | CONNECTORS | EA | 20 | $0.00 | |
| C | 030 | GROUNDING RODS | EA | 5 | $0.00 | |
| BID ITEMS 0024 THROUGH 0033 ARE FOR WORK IN FAMILY HOUSING (RESIDENTIAL) AREAS ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| C | 031 | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 50 | $0.00 | |
| C | 032 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 100 | $0.00 | |
| C | 033 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 250 | $0.00 | |
| C | 034 | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| C | 035 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 200 | $0.00 | |
| C | 036 | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| C | 037 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| C | 038 | REPAIR EPDM ROOF EDGE TERMINATION CONDITION ACCORDING TO ATTACHED DETAIL | LF | 300 | $0.00 | |
| C | 039 | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| C | 03A | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 50 | $0.00 | |
| BID ITEMS 0034 THROUGH 0064 ARE FOR WORK IN THE CANTONMENT (NON-RESIDENTIAL) AREA ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| C | 03B | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 100 | $0.00 | |
| C | 03C | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| C | 03D | REMOVE FULLY-ADHERED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| C | 03G | REMOVE BALLASTED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| C | 03F | REMOVE MECHANICALLY ATTACHED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| C | 03G | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 50 | $0.00 | |
| C | 03H | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 50 | $0.00 | |
| C | 03J | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| C | 03K | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 100 | $0.00 | |
| C | 03L | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 100 | $0.00 | |
| C | 03M | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| C | 03N | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| C | 03P | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 100 | $0.00 | |
| C | 03Q | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=20) | SQ | 100 | $0.00 | |
| C | 03R | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=30) | SQ | 200 | $0.00 | |
| C | 03S | INSTALL NEW FULLY-ADHERED ROOF SYSTEM (NO INSULATION) | SQ | 200 | $0.00 | |
| C | 03T | INSTALL TAPERED INSULATION | BF | 100 | $0.00 | |
| C | 03U | INSTALL WALKWAYS | SF | 200 | $0.00 | |
| C | 03V | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE | SF | 100 | $0.00 | |
| C | 03W | REMOVE EXISTING BALLAST | SQ | 25 | $0.00 | |
| C | 03X | INSTALL NEW BALLAST | SQ | 25 | $0.00 | |
| C | 03Y | REMOVE DETERIORATED CORRUGATED METAL ROOF DECKING AND INSTALL NEW METAL ROOF DECKING | SQ | 100 | $0.00 | |
| C | 03Z | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WIH 12-INCH WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| C | 040 | REMOVAL OF EXISTING TERMINATION BAR AND INSTALLATION OF NEW TERMINATION BAR | LF | 50 | $0.00 | |
| C | 041 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 75 | $0.00 | |
| C | 042 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 100 | $0.00 | |
| C | 043 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| C | 044 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 10 | $0.00 | |
| C | 045 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 150 | $0.00 | |
| C | 046 | INSTALL NEW RIDGE VENT | LF | 180 | $0.00 | |
| C | 047 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| C | 048 | INSTALL LAMINATED, MULTI LAYERED, ARCHITECTURAL SHINGLES | SQ | 100 | $0.00 | |
| TOTAL ESTIMATED COST: Option Year 2 | $0.00 |
&CFA4625-11-R-0002
Attachment 3 &C1 July 2013 - 30 June 2014
Exhibit D Option Year 3
| LINE ITEM # | DESCRIPTION | UNIT | EST. QTY. | UNIT PRICE | TOTAL UNIT PRICE | |
| D | 001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | $0.00 | |
| D | 002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, > 20 BF | BF | 600 | $0.00 | |
| D | 003 | REMOVE AND REPLACE WOOD DECKING | BF | 200 | $0.00 | |
| D | 004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 500 | $0.00 | |
| D | 005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, 0-20 BF | BF | 100 | $0.00 | |
| D | 006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, >20 BF | BF | 100 | $0.00 | |
| D | 007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |
| TEAR-OFFS | ||||||
| D | 008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSUL.) | SQ | 500 | $0.00 | |
| D | 009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" THICK | SQ | 500 | $0.00 | |
| D | 00A | ADD FOR DEMOLITION, HAULING, AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS | SQ | 10 | $0.00 | |
| INSTALL NEW BUILT UP ROOF SYSTEMS (BURS) OVER STEEL DECKS | ||||||
| D | 00B | 4-PLY BURS USING ASPHALT | SQ | 10 | $0.00 | |
| D | 00C | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 10 | $0.00 | |
| PARTIAL BURS REPAIRS | ||||||
| D | 00D | REPAIR BLISTERS | SF | 200 | $0.00 | |
| D | 00E | REPAIR SPLITS | LF | 50 | $0.00 | |
| D | 00F | REPAIR RIDGES | LF | 50 | $0.00 | |
| FURNISH AND INSTALL NEW ROOF INSULATION POLYISOCY ANURATE BOARD INSULATION | ||||||
| D | 00G | 1" THICK, R7.14 | SQ | 100 | $0.00 | |
| D | 00H | 2" THICK, R14.29 | SQ | 100 | $0.00 | |
| D | 00J | 3" THICK, R21.74 | SQ | 1000 | $0.00 | |
| PERLITE BOARD INSULATION, 3/4" THICK, R2.08 | ||||||
| D | 00K | <= 100 SQ | SQ | 100 | $0.00 | |
| D | 00L | GYPSUM (Dens-Deck 1/2") | SQ | 1200 | $0.00 | |
| D | 00M | BATT ROOF INSULATION, R-19 | SF | 1000 | $0.00 | |
| D | 00N | FIBER CANTS | LF | 200 | $0.00 | |
| D | 00P | WOOD CANTS | LF | 50 | $0.00 | |
| D | 00Q | TAPERED FILL 4" INSULATION BOARD | BF | 1000 | $0.00 | |
| D | 00R | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 1000 | $0.00 | |
| SHINGLE ROOFING SYSTEMS | ||||||
| D | 00S | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHINGS AND DRIP EDGES | SQ | 100 | $0.00 | |
| D | 00T | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 100 | $0.00 | |
| D | 00U | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS,INCLUDEING FELT UNDERLAYMENT. | SQ | 10 | $0.00 | |
| D | 00V | FURNISH AND INSTALL CONTINUOUS RIDGE VENTS ON EXISTING ROOFS | LF | 1000 | $0.00 | |
| STANDING SEAM METAL ROOFING | ||||||
| D | 00W | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | |
| D | 00X | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, <=100 SQ | SQ | 100 | $0.00 | |
| D | 00Y | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 100 | $0.00 | |
| D | 00Z | FASCIA PANEL SYSTEM | SF | 100 | $0.00 | |
| D | 010 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |
| D | 011 | INSTALL NEW Fully ADHERED TPO ROOF SYSTEM (R=30) | SQ | 500 | $0.00 | |
| D | 012 | INSTALL NEW FULL ADHERED TPO ROOF SYSTEM (NO INSULATION) | SQ | 500 | $0.00 | |
| D | 013 | REMOVE EXISTING MECHANICALLY-ATTACHED EPDM ROOF SYSTEM, INCLUDING MEMBRANE, INSULATION, FASTENERS, PROTECTION BOARD, FLASHINGS, AND VAPOR BARRIER --DOWN TO ROOF DECKING | SQ | 500 | $0.00 | |
| D | 014 | REMOVE EXISTING MECHANICALLY ATTACHED EPDM ROOF SYSTEM DOWN TO INSULATION AND INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM | SQ | 150 | $0.00 | |
| D | 015 | FURNISH AND INSTALL TAPERED INSULATION | SQ | 100 | $0.00 | |
| D | 016 | FURNISH AND INSTALL WALKWAYS | SF | 100 | $0.00 | |
| D | 017 | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE, TO INCLUDE WASHING WITH WATER TO REVEAL HOLES AND DAMAGE, AND VISUALLY LOCATING EACH HOLE AND PATCHING | SQ | 75 | $0.00 | |
| D | 018 | CLEANING AND INSPECTION OF EPDM FLASHING AND REPAIR OR REPLACE | LF | 150 | $0.00 | |
| D | 019 | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WITH 12 - IN WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| D | 01A | REMOVE EXISTING DETERIORATED TERMINATION BAR AND INSTALL NEW TERMINATION BAR | LF | 200 | $0.00 | |
| D | 01B | REPAIR OR REPLACE VENT THRU ROOF PENETRATION BOOTS OR FLASHINGS | EA | 25 | $0.00 | |
| MISCELLANEOUS METALS FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIM.) | ||||||
| D | 01C | GALVANIZED METAL, 4" - 5" | LF | 50 | $0.00 | |
| D | 01D | GALVANIZED METAL, 6" - 7" | LF | 50 | $0.00 | |
| D | 01E | ALUMINUM, 4" - 5" | LF | 50 | $0.00 | |
| D | 01F | ALUMINUM, 6" - 7" | LF | 50 | $0.00 | |
| D | 01G | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | |
| D | 01H | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | |
| D | 01J | 2-PIECE ALUMINUM, 7" -10" | LF | 50 | $0.00 | |
| D | 01K | 2-PIECE ALUMINUM, 10" -12" | LF | 50 | $0.00 | |
| FURNISH AND INSTALL | ||||||
| D | 01L | GALVANIZED METAL DRIP EDGE | LF | 200 | $0.00 | |
| D | 01M | GALVANIZED METAL COUNTERFLASHING | SF | 100 | $0.00 | |
| D | 01N | GALVANIZED METAL VALLEY FLASHING | SF | 50 | $0.00 | |
| D | 01P | GALVANIZED METAL STEP FLASHING | SF | 50 | $0.00 | |
| D | 01Q | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | |
| D | 01R | GALVANIZED METAL FLASHING - F LAT SHEET | SF | 50 | $0.00 | |
| D | 01S | GALVANIZED METAL CAP FLASHING | SF | 50 | $0.00 | |
| D | 01T | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |
| D | 01U | ALUMINUM COUNTERFLASHING | SF | 250 | $0.00 | |
| D | 01V | ALUMINUM VALLEY FLASHING | SF | 25 | $0.00 | |
| D | 01W | ALUMINUM STEP FLASHING | SF | 25 | $0.00 | |
| D | 01X | ALUMINUM BASE FLASHING | SF | 25 | $0.00 | |
| D | 01Y | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | |
| D | 01Z | ALUMINUM CAP FLASHING | SF | 50 | $0.00 | |
| D | 020 | FURNISH AND INSTALL CONTINUOUS RIDGE VENT | LF | 200 | $0.00 | |
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | ||||||
| D | 021 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | |
| D | 022 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | |
| D | 023 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | |
| ROOF DRAINS | ||||||
| D | 024 | REFLASHING EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 8 | $0.00 | |
| D | 025 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 10 | $0.00 | |
| MISCELLANEOUS ROOFING ITEMS | ||||||
| D | 026 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | |
| D | 027 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | |
| D | 028 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | |
| D | 029 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 5 | $0.00 | |
| D | 02A | REMOVE AND REPLACE PITCH PAN | EA | 5 | $0.00 | |
| D | 02B | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1000 | $0.00 | |
| D | 02C | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1000 | $0.00 | |
| D | 02D | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |
| D | 02E | REPAIR AND REPLACE SPALLS, HOLESL, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 52 | $0.00 | |
| D | 02F | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE | SQ | 50 | $0.00 | |
| D | 02G | FURNISH AND INSTALL ASPHALT-SATURATED FELT UNDERLAYMENT | SQ | 100 | $0.00 | |
| D | 02H | FLUID APPLIED COATING SYSTEM | SF | 2000 | $0.00 | |
| D | 02J | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 | EA | 1 | $0.00 | |
| D | 02K | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 10 | $0.00 | |
| D | 02L | LABOR RATE-MISCELLANEOUS WORK | MH | 3 | $0.00 | |
| GUTTERS AND DOWNSPOUTS | ||||||
| D | 02M | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 200 | $0.00 | |
| D | 02N | FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, GUTTER SCREENS | LF | 1000 | $0.00 | |
| D | 02P | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 500 | $0.00 | |
| D | 02Q | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 500 | $0.00 | |
| D | 02R | ALUMINUM, 4" X 5" | LF | 100 | $0.00 | |
| D | 02S | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | |
| FURNISH AND INSTALL NEW DOWNSPOUTS, INCLUDING BRACKETS, ETC. | ||||||
| D | 02T | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 300 | $0.00 | |
| D | 02U | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | |
| D | 02V | FURNISH AND INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 10 | $0.00 | |
| LIGHTNING PROTECTION / REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM | ||||||
| D | 02W | AIR TERMINALS, INCLUDES COPPER BASE | EA | 20 | $0.00 | |
| D | 02X | CONDUCTORS | LF | 200 | $0.00 | |
| D | 02Y | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 200 | $0.00 | |
| D | 02Z | CONNECTORS | EA | 20 | $0.00 | |
| D | 030 | GROUNDING RODS | EA | 5 | $0.00 | |
| BID ITEMS 0024 THROUGH 0033 ARE FOR WORK IN FAMILY HOUSING (RESIDENTIAL) AREAS ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| D | 031 | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 50 | $0.00 | |
| D | 032 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 100 | $0.00 | |
| D | 033 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 250 | $0.00 | |
| D | 034 | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| D | 035 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 200 | $0.00 | |
| D | 036 | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| D | 037 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| D | 038 | REPAIR EPDM ROOF EDGE TERMINATION CONDITION ACCORDING TO ATTACHED DETAIL | LF | 300 | $0.00 | |
| D | 039 | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| D | 03A | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 50 | $0.00 | |
| BID ITEMS 0034 THROUGH 0064 ARE FOR WORK IN THE CANTONMENT (NON-RESIDENTIAL) AREA ONLY, AND DO NOT INVOLVE ASBESTOS | ||||||
| D | 03B | REMOVE SHINGLE ROOFING (UPTO 2 LAYERS) | SQ | 100 | $0.00 | |
| D | 03C | REMOVE BUILT-UP ROOF SYSTEM | SQ | 100 | $0.00 | |
| D | 03D | REMOVE FULLY-ADHERED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| D | 03G | REMOVE BALLASTED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| D | 03F | REMOVE MECHANICALLY ATTACHED EPDM ROOF SYSTEM | SQ | 100 | $0.00 | |
| D | 03G | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 50 | $0.00 | |
| D | 03H | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 50 | $0.00 | |
| D | 03J | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| D | 03K | INSTALL NEW SHINGLE, ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 100 | $0.00 | |
| D | 03L | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 100 | $0.00 | |
| D | 03M | INSTALL NEW RIDGE VENT | LF | 500 | $0.00 | |
| D | 03N | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| D | 03P | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=10) | SQ | 100 | $0.00 | |
| D | 03Q | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=20) | SQ | 100 | $0.00 | |
| D | 03R | INSTALL NEW FULLY-ADHERED EPDM ROOF SYSTEM (R=30) | SQ | 200 | $0.00 | |
| D | 03S | INSTALL NEW FULLY-ADHERED ROOF SYSTEM (NO INSULATION) | SQ | 200 | $0.00 | |
| D | 03T | INSTALL TAPERED INSULATION | BF | 100 | $0.00 | |
| D | 03U | INSTALL WALKWAYS | SF | 200 | $0.00 | |
| D | 03V | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE | SF | 100 | $0.00 | |
| D | 03W | REMOVE EXISTING BALLAST | SQ | 25 | $0.00 | |
| D | 03X | INSTALL NEW BALLAST | SQ | 25 | $0.00 | |
| D | 03Y | REMOVE DETERIORATED CORRUGATED METAL ROOF DECKING AND INSTALL NEW METAL ROOF DECKING | SQ | 100 | $0.00 | |
| D | 03Z | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WIH 12-INCH WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| D | 040 | REMOVAL OF EXISTING TERMINATION BAR AND INSTALLATION OF NEW TERMINATION BAR | LF | 50 | $0.00 | |
| D | 041 | ROOF SHEATHING REMOVAL AND REPLACEMENT | SF | 75 | $0.00 | |
| D | 042 | STRUCTURAL LUMBER REMOVAL AND REPLACEMENT | BF | 100 | $0.00 | |
| D | 043 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED FIBERGLASS) | SQ | 100 | $0.00 | |
| D | 044 | INSTALL NEW SHINGLE ROOFING (ASPHALT-SATURATED ORGANIC FELT) | SQ | 10 | $0.00 | |
| D | 045 | REMOVE EXISTING SOFFIT AND FASCIA AND INSTALL NEW SOFFIT AND FASCIA | LF | 150 | $0.00 | |
| D | 046 | INSTALL NEW RIDGE VENT | LF | 180 | $0.00 | |
| D | 047 | REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND INSTALL NEW GUTTER, GUTTER SCREENS, AND DOWNSPOUTS | LF | 200 | $0.00 | |
| D | 048 | INSTALL LAMINATED, MULTI LAYERED, ARCHITECTURAL SHINGLES | SQ | 100 | $0.00 | |
| TOTAL ESTIMATED COST: Option Year 3 | $0.00 |
&CFA4625-11-R-0002
Attachment 3 &C1 July 2014 - 30 June 2015
Exhibit E Option Year 4
| LINE ITEM # | DESCRIPTION | UNIT | EST. QTY. | UNIT PRICE | TOTAL UNIT PRICE | |
| E | 001 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, 0-20 BF | BF | 100 | $0.00 | |
| E | 002 | REMOVE AND REPLACE EXISTING WOOD BLOCKING, NAILER, OR FRAMING, NOMINAL 2" THICK, > 20 BF | BF | 600 | $0.00 | |
| E | 003 | REMOVE AND REPLACE WOOD DECKING | BF | 200 | $0.00 | |
| E | 004 | REMOVE AND REPLACE PLYWOOD ROOF SHEATHING | SF | 500 | $0.00 | |
| E | 005 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, 0-20 BF | BF | 100 | $0.00 | |
| E | 006 | REMOVE AND REPLACE EXISTING WOOD FASCIA BOARDS, NOMINAL 1" THINK, >20 BF | BF | 100 | $0.00 | |
| E | 007 | REMOVE AND REPLACE EXISTING HARDBOARD SOFFIT (3/8") | SF | 100 | $0.00 | |
| TEAR-OFFS | ||||||
| E | 008 | DEMOLITION, HAULING, AND DISPOSAL OF UP TO 5-PLY BURS WITH FLASHINGS, GRAVEL, ETC. (DOES NOT INCLUDE INSUL.) | SQ | 500 | $0.00 | |
| E | 009 | DEMOLITION, HAULING, AND DISPOSAL OF INSULATION UP TO 3" THICK | SQ | 500 | $0.00 | |
| E | 00A | ADD FOR DEMOLITION, HAULING, AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS | SQ | 10 | $0.00 | |
| INSTALL NEW BUILT UP ROOF SYSTEMS (BURS) OVER STEEL DECKS | ||||||
| E | 00B | 4-PLY BURS USING ASPHALT | SQ | 10 | $0.00 | |
| E | 00C | 4-PLY BURS WITH SBS MODIFIED CAP SHEET | SQ | 10 | $0.00 | |
| PARTIAL BURS REPAIRS | ||||||
| E | 00D | REPAIR BLISTERS | SF | 200 | $0.00 | |
| E | 00E | REPAIR SPLITS | LF | 50 | $0.00 | |
| E | 00F | REPAIR RIDGES | LF | 50 | $0.00 | |
| FURNISH AND INSTALL NEW ROOF INSULATION POLYISOCY ANURATE BOARD INSULATION | ||||||
| E | 00G | 1" THICK, R7.14 | SQ | 100 | $0.00 | |
| E | 00H | 2" THICK, R14.29 | SQ | 100 | $0.00 | |
| E | 00J | 3" THICK, R21.74 | SQ | 1000 | $0.00 | |
| PERLITE BOARD INSULATION, 3/4" THICK, R2.08 | ||||||
| E | 00K | <= 100 SQ | SQ | 100 | $0.00 | |
| E | 00L | GYPSUM (Dens-Deck 1/2") | SQ | 1200 | $0.00 | |
| E | 00M | BATT ROOF INSULATION, R-19 | SF | 1000 | $0.00 | |
| E | 00N | FIBER CANTS | LF | 200 | $0.00 | |
| E | 00P | WOOD CANTS | LF | 50 | $0.00 | |
| E | 00Q | TAPERED FILL 4" INSULATION BOARD | BF | 1000 | $0.00 | |
| E | 00R | TAPERED 1/4" PER FOOT FOR DRAINAGE | BF | 1000 | $0.00 | |
| SHINGLE ROOFING SYSTEMS | ||||||
| E | 00S | REMOVE AND DISPOSE OF EXISTING ROOF SHINGLE SYSTEM AND UNDERLAYMENT, INCLUDING FLASHINGS AND DRIP EDGES | SQ | 100 | $0.00 | |
| E | 00T | FURNISH AND INSTALL NEW MINERAL SURFACED FIBERGLASS STRIP SHINGLE SYSTEM INCLUDING UNDERLAYMENT | SQ | 100 | $0.00 | |
| E | 00U | REMOVE AND REPLACE EXISTING SHINGLES WITH NEW FIBERGLASS STRIP SHINGLES TO MATCH ADJACENT AREAS, PARTIAL REPAIRS,INCLUDEING FELT UNDERLAYMENT. | SQ | 10 | $0.00 | |
| E | 00V | FURNISH AND INSTALL CONTINUOUS RIDGE VENTS ON EXISTING ROOFS | LF | 1000 | $0.00 | |
| STANDING SEAM METAL ROOFING | ||||||
| E | 00W | DEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING METAL ROOFING SYSTEM | SQ | 100 | $0.00 | |
| E | 00X | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, <=100 SQ | SQ | 100 | $0.00 | |
| E | 00Y | NEW STANDING SEAM METAL ROOF SYSTEM, STRUCTURAL, >100 SQ | SQ | 100 | $0.00 | |
| E | 00Z | FASCIA PANEL SYSTEM | SF | 100 | $0.00 | |
| E | 010 | PERFORATED SOFFIT PANEL | SF | 100 | $0.00 | |
| E | 011 | INSTALL NEW Fully ADHERED TPO ROOF SYSTEM (R=30) | SQ | 500 | $0.00 | |
| E | 012 | INSTALL NEW FULL ADHERED TPO ROOF SYSTEM (NO INSULATION) | SQ | 500 | $0.00 | |
| E | 013 | REMOVE EXISTING MECHANICALLY-ATTACHED EPDM ROOF SYSTEM, INCLUDING MEMBRANE, INSULATION, FASTENERS, PROTECTION BOARD, FLASHINGS, AND VAPOR BARRIER --DOWN TO ROOF DECKING | SQ | 500 | $0.00 | |
| E | 014 | REMOVE EXISTING MECHANICALLY ATTACHED EPDM ROOF SYSTEM DOWN TO INSULATION AND INSTALL NEW FULLY ADHERED TPO ROOF SYSTEM | SQ | 150 | $0.00 | |
| E | 015 | FURNISH AND INSTALL TAPERED INSULATION | SQ | 100 | $0.00 | |
| E | 016 | FURNISH AND INSTALL WALKWAYS | SF | 100 | $0.00 | |
| E | 017 | PATCHING OF HOLES IN EXISTING EPDM MEMBRANE, TO INCLUDE WASHING WITH WATER TO REVEAL HOLES AND DAMAGE, AND VISUALLY LOCATING EACH HOLE AND PATCHING | SQ | 75 | $0.00 | |
| E | 018 | CLEANING AND INSPECTION OF EPDM FLASHING AND REPAIR OR REPLACE | LF | 150 | $0.00 | |
| E | 019 | REPAIR SEAMS IN EXISTING EPDM MEMBRANE BY COVERING SEAM WITH 12 - IN WIDE CURED SELF-ADHESIVE EPDM TAPE | LF | 200 | $0.00 | |
| E | 01A | REMOVE EXISTING DETERIORATED TERMINATION BAR AND INSTALL NEW TERMINATION BAR | LF | 200 | $0.00 | |
| E | 01B | REPAIR OR REPLACE VENT THRU ROOF PENETRATION BOOTS OR FLASHINGS | EA | 25 | $0.00 | |
| MISCELLANEOUS METALS FURNISH AND INSTALL NEW GRAVEL GUARD/FASCIA (FACE DIM.) | ||||||
| E | 01C | GALVANIZED METAL, 4" - 5" | LF | 50 | $0.00 | |
| E | 01D | GALVANIZED METAL, 6" - 7" | LF | 50 | $0.00 | |
| E | 01E | ALUMINUM, 4" - 5" | LF | 50 | $0.00 | |
| E | 01F | ALUMINUM, 6" - 7" | LF | 50 | $0.00 | |
| E | 01G | 2-PIECE GALVANIZED METAL, 7" - 10" | LF | 50 | $0.00 | |
| E | 01H | 2-PIECE GALVANIZED METAL, 10" - 12" | LF | 50 | $0.00 | |
| E | 01J | 2-PIECE ALUMINUM, 7" -10" | LF | 50 | $0.00 | |
| E | 01K | 2-PIECE ALUMINUM, 10" -12" | LF | 50 | $0.00 | |
| FURNISH AND INSTALL | ||||||
| E | 01L | GALVANIZED METAL DRIP EDGE | LF | 200 | $0.00 | |
| E | 01M | GALVANIZED METAL COUNTERFLASHING | SF | 100 | $0.00 | |
| E | 01N | GALVANIZED METAL VALLEY FLASHING | SF | 50 | $0.00 | |
| E | 01P | GALVANIZED METAL STEP FLASHING | SF | 50 | $0.00 | |
| E | 01Q | GALVANIZED METAL BASE FLASHING | SF | 100 | $0.00 | |
| E | 01R | GALVANIZED METAL FLASHING - F LAT SHEET | SF | 50 | $0.00 | |
| E | 01S | GALVANIZED METAL CAP FLASHING | SF | 50 | $0.00 | |
| E | 01T | ALUMINUM DRIP EDGE | LF | 250 | $0.00 | |
| E | 01U | ALUMINUM COUNTERFLASHING | SF | 250 | $0.00 | |
| E | 01V | ALUMINUM VALLEY FLASHING | SF | 25 | $0.00 | |
| E | 01W | ALUMINUM STEP FLASHING | SF | 25 | $0.00 | |
| E | 01X | ALUMINUM BASE FLASHING | SF | 25 | $0.00 | |
| E | 01Y | ALUMINUM FLASHING - FLAT SHEET | SF | 100 | $0.00 | |
| E | 01Z | ALUMINUM CAP FLASHING | SF | 50 | $0.00 | |
| E | 020 | FURNISH AND INSTALL CONTINUOUS RIDGE VENT | LF | 200 | $0.00 | |
| REMOVE EXISTING EXPANSION JOINT AND INSTALL NEW EXPANSION JOINT | ||||||
| E | 021 | ELASTOMERIC TYPE (NEOPRENE BELLOWS) | LF | 100 | $0.00 | |
| E | 022 | ALUMINUM CAPPED CURB | LF | 100 | $0.00 | |
| E | 023 | GALVANIZED CAPPED CURB | LF | 50 | $0.00 | |
| ROOF DRAINS | ||||||
| E | 024 | REFLASHING EXISTING ROOF DRAIN, INCLUDES NEW LEAD FLASHING, CLAMPING RING, AND CAST IRON DOME STRAINER | EA | 8 | $0.00 | |
| E | 025 | REMOVE AND REPLACE EXISTING ROOF DRAIN, INCLUDES NEW CAST IRON DOME STRAINER | EA | 10 | $0.00 | |
| MISCELLANEOUS ROOFING ITEMS | ||||||
| E | 026 | EXTEND PLUMBING VENTS | LF | 10 | $0.00 | |
| E | 027 | FLEXIBLE VENT PIPE FLASHING (METAL ROOFS) | EA | 10 | $0.00 | |
| E | 028 | REMOVE AND REPLACE LEAD FLASHING AT VENT THRU ROOF (VTR) | EA | 10 | $0.00 | |
| E | 029 | REMOVE EXISTING VTR PENETRATION FLASHING AND REPLACE WITH COLLAR TYPE FLASHING | EA | 5 | $0.00 | |
| E | 02A | REMOVE AND REPLACE PITCH PAN | EA | 5 | $0.00 | |
| E | 02B | PAINT, BASE SCHEME, EXT. LATEX, 1 COAT | SF | 1000 | $0.00 | |
| E | 02C | PAINT, BASE SCHEME, EXT. LATEX, PRIMER AND 2 COATS | SF | 1000 | $0.00 | |
| E | 02D | REMOVE EXISTING STEEL ROOF DECK AND REPLACE WITH NEW STEEL ROOF DECK | SQ | 25 | $0.00 | |
| E | 02E | REPAIR AND REPLACE SPALLS, HOLESL, AND CRACKS IN EXISTING CONCRETE ROOF DECK | SF | 52 | $0.00 | |
| E | 02F | FURNISH AND INSTALL VAPOR BARRIER OVER CONCRETE | SQ | 50 | $0.00 | |
| E | 02G | FURNISH AND INSTALL ASPHALT-SATURATED FELT UNDERLAYMENT | SQ | 100 | $0.00 | |
| E | 02H | FLUID APPLIED COATING SYSTEM | SF | 2000 | $0.00 | |
| E | 02J | DISCONNECT AND RECONNECT ELECTRICAL SERVICE (<200 | EA | 1 | $0.00 | |
| E | 02K | REMOVE EXISTING CONDUIT, ETC. AND REPLACE WITH NEW 3/4" RIGID CONDUIT, INCLUDING WIRE, BOXES, FITTINGS, ETC. | LF | 10 | $0.00 | |
| E | 02L | LABOR RATE-MISCELLANEOUS WORK | MH | 3 | $0.00 | |
| GUTTERS AND DOWNSPOUTS | ||||||
| E | 02M | REMOVE EXISTING GUTTER AND DOWNSPOUTS | LF | 200 | $0.00 | |
| E | 02N | FURNISH AND INSTALL NEW GUTTER, BOX, INCLUDING HANGARS, BRACKETS, SEALANTS, GUTTER SCREENS | LF | 1000 | $0.00 | |
| E | 02P | 24 GA. GALVANIZED/PRIMED, 4" X 5" | LF | 500 | $0.00 | |
| E | 02Q | 24 GA. GALVANIZED/PRIMED, 5" X 7" | LF | 500 | $0.00 | |
| E | 02R | ALUMINUM, 4" X 5" | LF | 100 | $0.00 | |
| E | 02S | ALUMINUM, 5" X 7" | LF | 100 | $0.00 | |
| FURNISH AND INSTALL NEW DOWNSPOUTS, INCLUDING BRACKETS, ETC. | ||||||
| E | 02T | 24 GA. GALVANIZED/PRIMED, 3" X 4" | LF | 300 | $0.00 | |
| E | 02U | ALUMINUM, 3" X 4" | LF | 100 | $0.00 | |
| E | 02V | FURNISH AND INSTALL NEW PRE-FORMED CONCRETE SPLASHBLOCKS | EA | 10 | $0.00 | |
| LIGHTNING PROTECTION / REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM | ||||||
| E | 02W | AIR TERMINALS, INCLUDES COPPER BASE | EA | 20 | $0.00 | |
| E | 02X | CONDUCTORS | LF | 200 | $0.00 | |
| E | 02Y | FASTENERS, INCLUDES LOOPS AND CLIPS | EA | 200 | $0.00 | |
| E | 02Z | CONNECTORS | EA | 20 | $0.00 |