FA4620-18-Q-A036
Amendment 2 Attachment 2
Salient Characteristics for Battery Bank
20 Aug 2018
Battery-
Li-ion NMC or battery with equivalent storage density, safety, and usable lifespan.
Pack Capacity must be 60Ah/ 1500Wh Minimum, and have charging and low battery protection built in.
Supports a minimum of 100 charge/discharge cycles to 80% capacity.
Minimum of 3 month battery shelf life.
Built in Pure Sine Wave inverter.
-The unit must have at a minimum the following ports.
Minimum 1 USB-A port output 5V up to 2.4A.
Minimum 1 USB-C output: 5V up to 3A.
Minimum 2 120V AC outlets powered by on/off switch.
-Onboard Lighting
LED output white or green lights.
-Charging/Usage
Minimum 8 hour usage time at maximum draw.
Maximum 25 hour recharge time when plugged into 115-120 AC Volt wall output.
-Color
High visibility color Markers.
Salient Characteristics for Solar Panels
-Solar Panel
Polycrystalline or Monocrystalline.
100W rating per solar panel.
Open Circuit Voltage: 17.4 – 22V.
1258433315C Highlight
FA4620-18-Q-A036
Amendment 2 Attachment 2
Chainable to other solar panels.
General Requirements
-Maximum 110lbs total weight between battery pack and charging panels.
-Thermal operating range: 32-104 F (0-40 C).
-1 Year manufacturer standard warranty.
1258433315C Highlight