Question 1) What is the primary use of these units?

Answer 1) These solar power generated banks will support 4 Flights of 25 - 30 Cadre instructing survival and evasion TTP's 60 miles north in the Colville National Forest. They will supply power to charge radio batteries and operate lights/heating during austere conditions.

Question 2) What will the power draw on the units will be?

Answer 2) The government estimates the necessary draw to be 1500W.

Question 3) What weather conditions will the units be used in?

Answer 3) Training happens 48 weeks out of the year and the weather in the winter can dip to -20 degrees Fahrenheit for short periods. The summer weather will also reach into the low 100s Fahrenheit on occasion.

FA4620-18-Q-A036 Amendment 1 Attachment 02