About this file
This document is a Vendor Confirmation Form for Solicitation FA461325Q0020, specifically for CLIN 0001 involving a Traffic Light Control Panel. The form requires vendors to confirm compliance with a detailed list of technical and operational specifications, including:
Key technical requirements include replacing existing conflict monitors with a Malfunction Management Unit, installing Load Switches, Flashers, Bus Interface Units, Flash Transfer Relays, and Exhaust Fans. The vendor must provide a Uninterrupted Power Supply (UPS) capable of operating an intersection in 4-way flashing mode for at least 12 hours. Additional requirements include replacing mercury contact switches with Solid State Drive (SSD) components, supplying padlocks for cabinets, and updating pedestrian signage to meet the most recent Manual on Uniform Traffic Control Devices (MUTCD) standards. The form also seeks confirmation on warranty (2 years or greater), shipping, installation, on-site training, project coordination, 90-day delivery timeline, and compatibility with the current Yunex System.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - FA461325Q0020.pdf | ||
| Attachment 1 - PWS 10 Sept 2025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INSTRUCTIONS: Please put in the model name and put a check in the "YES" or "NO" box if the model you quoted previously meets the standards below. Provide supporting documents to verify your answers.
Solicitation: FA461325Q0020 Cage Code:
CLIN 0001: Traffic Light Control Panel Must have the following characteristics, but not limited to:
Model Name: Yes No Comments Malfunction Management Unit (to replace existing conflict monitors) Load Switch Flashers Bus Interface Units Flash Transfer Relays Exhaust fans Uninterrupted Power Supply (UPS) - must be capable of operating intersection in 4 way flashing configuration for a minimum of 12 hours Replace mercury contact switches with Solid State Drive (SSD) components Supply padlocks (all keyed alike) for each cabinet Update/replace existing pedestrian signage at each intersection to reflect most recent Manual on Uniform Traffic Control Devices (MUTCD) standards
Yes No Comments 2 year or greater warranty Shipping Install and travel On-site training Project coordination Delivery complete within 90 calendar days All components are compatible with current Yunex System