Atch 3 Technical Performance Questionnaire 20240712.docx
DOCX document 42 KB Posted
- Attached to
- Vandenberg SFB DWDM Phase 4 Federal contract opportunity
- Solicitation number
- FA461024Q0018
About this file
This document is a Technical Performance Questionnaire related to a federal contract opportunity for Dense Wavelength Division Multiplexing (DWDM) Installation Services at Vandenberg Space Force Base.
The key details are:
- The contract requires a minimum of 5 years of experience within the last 7 years providing DWDM installation services, including designing, procuring, installing, configuring, testing, and activating DWDM/OTN components.
- Offerors must provide detailed descriptions of specific tasks performed related to DWDM installation, and a minimum of 1 and up to 5 references to support the claimed experience.
- If using a subcontractor, offerors must provide the name, percentage of work, and work description for the subcontractor.
- The contract will be a Firm Fixed Price award under NAICS code 334118 with a size standard of 1,000 employees.
- A pre-proposal conference and site visit will be held on July 23-24, 2024. Questions are due by July 29, 2024 and quotes are due by August 13, 2024.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PHASE 4A QUESTIONS-ANSWERS.xlsx | XLSX spreadsheet | |
| Atch 1 SOW DWDM Phase 4 20240725.pdf | ||
| FA461024Q00180001 DWDM Phase 4 Amend 1 20240726.pdf | ||
| Atch 2 BNJ DWDM Phase 4 Redacted.pdf | ||
| Atch 1 SOW DWDM Phase 4 20240425.pdf | ||
| FA461024Q0018 DWDM Phase 4 20240713.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Instructions: Fill-in offeror name in footer. For each factor below, in the first table provide a detailed description of specific tasks performed for that factor. Use the reference table to provide a minimum of one (1) and up to five (5) references per factor to support the experience claimed in the first table. Limited to a twenty-five (25) page submission.
Technical Experience. Five (5) years of experience within the Seven (7) year period immediately preceding release of this Request for Quote (RFQ), providing Dense Wavelength Division Multiplexing Installation Services. The required experience is for work which is the same or substantially similar to the work activities and tasks described in the Statement of Work. Provide reference and contact information to support the experience claimed by offeror. If offeror intends or proposes to use an entity other than offeror to fulfill a requirement or a portion thereof (e.g. a sub-contractor or other teaming partner), please provide ALL the requested information for that entity as well.
To Be Considered Technically Acceptable: The offeror’s responses evidence the offeror (or the entity other than offeror which offeror intends or proposes to use to fulfill a requirement or portion thereof) has five (5) years of experience within the seven (7) year period immediately preceding the release of this RFQ, performing the same or substantially similar work to the work activities and tasks described in each of the factors and the referenced statement of work (SOW) paragraph(s). References provided must support the experience claimed by offeror.
Factor 1, DWDM Installation. At least five (5) years of experience within the seven (7) year period immediately preceding release of this RFQ. Use the narrative block to provide a detailed description of EACH task performed related to providing DWDM Installation Services identified in the table immediately below (Reference SOW). The table below is not all inclusive and the offeror is encouraged to provide any information that assists the Government in making a technical acceptability and technical experience determination.
| DWDM Installation Services |
| 5 Years of Experience Within the Last 7 Years |
The Contractor shall design, procure, install, configure, test and activate DWDM/OTN components that add a third 100Gb channel in the Core and Second Stage rings as shown in Diagram 2 within the Statement of Work. The installation and activation will meet the requirements outlined in this SOW and Table 1. Contractor shall procure Ciena equipment as identified in columns C1-C4 of Table 1 and as required by the Ciena design. Contractor shall acquire and install power components to adequately support existing loads and new channel components, perform asbestos abatement, install new racks, and install fiber management as appropriate and identified in Table 1, columns A1-A5.
The Contractor shall be Ciena 3926, 5142 and 6500 certified. The contractor shall be factory-certified and or factory authorized installers on Unipower Sageon series power distribution equipment.
|_|Yes |_|No
Narrative (please type in form and use as much detail as necessary to respond):
Past Performance Reference #1, Factor 1 (required)
| Contract # |
| Period of Performance |
| Total Value |
| Contract Type |
(Firm Fixed Price [FFP] or Cost)
| Performed By (provide name of company) |
| Performed as Prime (P) or Sub (S)? |
Check as appropriate
|_| P |_| S
POC Name:
Phone #:
Email:
Past Performance Reference #X, Factor 1 Repeat this block as necessary up to maximum of five (5)
| Contract # |
| Period of Performance |
| Total Value |
| Contract Type |
(Firm Fixed Price [FFP] or Cost)
| Performed By (provide name of company) |
| Performed as Prime (P) or Sub (S)? |
Check as appropriate
|_| P |_| S
POC Name:
Phone #:
Email:
Sub-Contracting Arrangements (e.g. Teaming Arrangements).
If your company is not performing ALL the work, you must fill-in the contemplated sub-contracting arrangement in Table 1 below for percentage of work performed by sub-contractor(s) and then fill in the percentage of work in Table 2 that will be performed by your company as the Prime Contractor. Sub-contractor arrangements include, but are not limited to, the following types of relationships: prime/sub-contractor, mentor/protégé, joint venture, etc. If a sub-contractor arrangement is not applicable and ALL the work will be performed by your company as the Prime Contractor, please indicate 0% in Table 1 and complete all fields in Table 2 accordingly.
Standard Of Acceptability: The offeror’s responses provide sufficient information for the Government to determine whether or not the offeror contemplates a sub-contracting arrangement and, if so, indicates the name of each sub-contractor, identifies the task and the percentage of work to be performed by each party (E.g. prime and subcontractor), and provides sufficient information for the Government to determine that the offeror as a whole (E.g. Prime/sub combined) has the ability to perform the requirements of this solicitation. For example, if the offeror is claiming the experience of another entity to meet factor 1, it would follow that entity would be identified as a teaming partner below.
Table 1
| Name of Sub-Contractor(s): |
| Percentage of Work Performed by Sub-Contractor |
| Work Description Sub-Contractor(s) Would Perform |
Table 2 Prime Contractor (Name Here) Percentage of Work Performed by Prime Contractor Work Description Prime Contractor Would Perform
Offeror:________________________
RFQ FA461024Q0018
Attachment 3