FA460825QS022 - Q and A CATM Range Mantiance Amendment 2.pdf
PDF 151 KB Posted
- Attached to
- CATM Range Maintenance Barksdale, AFB, LA.
- Solicitation number
- FA460825QS022
About this file
This document is an Amendment (Amendment 02) to a Request for Quote (RFQ) for Combat Arms Training and Maintenance (CATM) Range Maintenance at Barksdale Air Force Base, Louisiana. The amendment provides a detailed Q&A document with 30 specific questions and answers about the range's physical characteristics, including range dimensions (115 feet wide, 134 feet long, approximately 10,810 square feet), range features (one bay, 30 stations, steel trap, outdoor range, natural ventilation), and operational details. The amendment extends the RFQ due date to 12:00 PM CST on 16 June 2025.
The solicitation is a 100% small business set-aside for range maintenance services, with a NAICS code of 562910 and a small business size standard of $20.5M. The contract includes a base year from 21 September 2025 to 20 September 2026, with four potential option years through 20 September 2030. Key services include quarterly preventative maintenance, projectile and lead dust collection, scheduled maintenance, range cleaning, and potential unscheduled maintenance. The procurement will be awarded on a best value basis, with award anticipated based on initial responses, and funds are not currently available for the effort.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
2D CONTRACTING SQUADRON
BARKSDALE AIR FORCE BASE LOUISIANA
4 June 2025
MEMORANDUM FOR CONTRACTORS
FROM: 2CONS/PKA
801 Kenney Ave, Suite 2300 Barksdale AFB, LA 71110
SUBJECT: Amendment 02, FA460825QS022, CATM Range Maintenance.
1. The purpose of this Amendment is to:
a. Provide additional supplemental information in the form of a Question and Answers document.
b. Extend the RFQ due date and time.
2. It is the responsibility of the Offeror to read the entire PWS and all accompanying attachments of the RFQ and RFQ Amendment(s) for FA460825QS022.
1. Physical site address? Please see para 1.2.
2. Billing Address? Billing address will be provided to the winning bid vendor.
3. Job working hours? Please PWS para. 1.7.
4. Do you have a Forklift/Dock? Unable to answer the question without more context.
5. How do we get to your range? Access to the range may be achieved via multiple transportation conveyances. Transportation is the vendor’s choice. However, should a vendor opt to fly to the range, the vendor will need proper prior authorization through Base Operations and FAA. Entering the base via vehicle, the successful vendor may have to use a specific gate for entry.
6. Are there double doors for our equipment? Unable to answer the question without more context.
7. Indoor range or Outdoor Range? Outdoor range.
8. Granulated rubber or steel trap? Steel trap.
9. How many rounds do you shoot a year? The number of rounds fired per year varies by need.
10. Do you have any brass? If so, how much? The amount of brass is not germane to this solicitation.
11. How many bays? There is one bay.
12. How many lanes in each bay? There are 30 stations on the range.
13. What is the measurement of each lane? N/A.
14. What is the width and length of the entire range? 115 feet wide and 134 feet long.
15. What is the size of the range floor? The range floor is approx. 10,810 square feet.
16. Is there a concrete pad for the range floor, if this is an outdoor range? Please see PWS para.
1.4.
17. What is the measurement behind the firing line? Unable to answer the question without more context.
18. What is the measurement behind the trap? Unable to answer the question without more context.
19. Do you have curtains and if so, how many and width of them? There are no curtains.
20. Do you have a viewing window? Unable to answer the question without more context.
21. Do you have a 240v outlet? Single Phase? Single phase.
22. Do you have baffles and if so, how many and how wide are they? No baffles.
23. What is the length of the target rails? Targets are not germane to this solicitation.
24. What type of ventilation system do you have? Natural.
25. How many and what type of filters do you have in the ventilation system? (Pre-Filters, Mid- Filters, HEPA Filters). N/A.
26. What size are your filters? Please see Filter Model #P030904
27. What size are the DCU Filters? Please see Filter Model #P030904
28. Where is the filter box located? Filters are located within the DCU.
29. Are there any rooms connected to the range? If so, what are their dimensions? The Range Master Station measures approx. 7 feet by 16 feet.
30. Do you have fire retardant on the rubber? Unable to answer the question without more context.
3. The RFQ due date and time has been extended to 12:00 PM CST, 16 June 2025, for FA460825QS022.
4. Please direct any questions regarding this amendment to Contracting Specialist, SrA Jonathan Schrank, at jonathan.schrank@us.af.mil or at (318) 456-6840.
THOMAS HUTCHINS
Contracting Officer
REQUEST FOR QUOTE – ACKNOWLEDGEMENT
Amendment 02 - FA460825QS022, CATM Range Maintenance.
I acknowledge and agree to all terms and conditions of this RFQ, Amendment 02.
SIGNATURE COMPANY NAME
PRINTED NAME & TITLE OFFER DATE
All work shall be in strict accordance with the statement of work requirements.
| COMPANY NAME: | |
| PRINTED NAME TITLE: | |
| OFFER DATE: | |
| 2025-06-04T11:28:32-0500 | |
| HUTCHINS.THOMAS.A.1007591957 |
File details come from the government source that posted it. Updated .