Amendment 0001 - Tower Pictures.docx

DOCX document 6 MB Posted

Attached to
Non-resettable Flow Meter
Solicitation number
FA460026Q0024
Issued by

About this file

This is an amendment document containing technical specifications and architectural drawings for a training tower facility. The file includes dimensional measurements and layout diagrams showing the propane distribution system, including tank placement, pipe routing (115 feet from tank), electrical switch and conduit locations, and pressure range specifications for both aircraft mock-up equipment and building infrastructure. The images reference construction standards and provide visual documentation of the training tower's fuel delivery system and associated electrical components necessary for the fire department aircraft training facility at Offutt Air Force Base, Nebraska.

The amendment supports the solicitation FA460026Q0024 for installation of a non-resettable flow meter on the propane supply line to Unit 3-8. Key solicitation details include: a 100% small business set-aside with a mandatory site visit on April 1, 2026 at 9:00 AM; question deadline of April 3, 2026 at 11:00 AM CST with answers provided by April 6, 2026; quote submission deadline of April 9, 2026 at 11:00 AM CST; and 30-calendar-day delivery requirement following award on a firm fixed-price basis. The flow meter must be compatible with 2" Schedule 40 pipe, rated for liquid propane in hazardous outdoor areas, and calibrated per manufacturer specifications or annually. Contractor responsibilities include complete installation, all electrical hookups, and provision of tools, materials, equipment, and permits. Personnel without base access must submit SFS Form 31 by March 30, 2026 at 11:00 AM to attend the site visit. Award will be based on lowest price with acceptable technical rating, with no specific budget disclosed.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

62 ½” 14”

11’ 70”

6’ 10’

Flow Direction 115’ from tank

Electrical Switch and Conduit

Pictures after this point are from the building specs for the training tower. Should give a general idea of pressure ranges.

** Above picture is for the aircraft mock** image6.jpeg image7.jpeg image8.jpeg image9.jpeg image10.jpeg image11.jpeg image1.jpeg image2.jpeg image3.jpeg image4.jpeg image5.jpeg